• Title/Summary/Keyword: 양압

Search Result 97, Processing Time 0.023 seconds

Effect of Optimal Humidification for Extremely Low Birth Weight Infants During Nasal Continuous Positive Airway Pressure (인공호흡기 가습기 적용방법이 초극소 저출생 체중아의 경비지속 기도 양압 환기법 유지기간에 미치는 영향)

  • Kim, Jung-Sook;Lee, Eun-Jung
    • Child Health Nursing Research
    • /
    • v.17 no.2
    • /
    • pp.145-152
    • /
    • 2011
  • Purpose: To evaluate the efficacy of Optimal humidification during Nasal Continuous Positive Airway Pressure (nCPAP) for Extremely Low Birth Weight Infant (ELBWI). Methods: The study design was a pre-test-post-test nonequivalent nonsynchronized quasi-experimental design. The participants were 218 ELBWI on nCPAP (experimental group: 102 and control group: 116). Data collection was conducted from January 2005 to April 2010. In order to measure and analyze the nCPAP duration, reintubation and nasal condition, Chi-square test and t-test were used. Results: Hypothesis 1, that the duration with nCPAP in the experimental group is longer than that of the control group and hypothesis 2-3, that the rate of reintubation and nasal problems in the experimental group are lower than the control group, were all supported as there were statistically significant differences between two groups. Conclusion: The findings suggest that the Optimal humidification in this study is an efficient intervention because it helps increase the last time of nCPAP with ELBWI and minimize complications. It is expected that Optimal humidification is beneficial and helpful in preventing and caring for respiratory problems in these infants.

Automation System of Explosion-Proof Panel Condition (방폭 패널 컨디션 자동화 시스템(1))

  • Hwang, Dae-Hyeon;Choi, Kwang-Il;Bae, Young-Chul
    • The Journal of the Korea institute of electronic communication sciences
    • /
    • v.15 no.2
    • /
    • pp.253-258
    • /
    • 2020
  • Petrochemical industry complex in Korea always has high riskiness due to explosive and inflammable gases. To prevent these explosion, most facility of petrochemical industry complex requires the performance of explosive proof. The control panel, which is used as explosive proof, has been used the air injection method by manually from outside to constantly keep the temperature and pressure between inside and outside of the panel. In this paper, we propose the automatic temperature controller, which performs automatic heating and cooling according to temperature inside the panel in order to control temperature automatically.

Design of Integration Controller of Explosive Proof Panel (방폭 패널 통합 제어기 설계)

  • Bak, Gwi-Man;Bae, Young-Chul
    • The Journal of the Korea institute of electronic communication sciences
    • /
    • v.15 no.2
    • /
    • pp.267-272
    • /
    • 2020
  • Currently, the petrochemical industry complex always has remained with the explosive riskiness due to explosive and inflammable gases. In order to prevent explosion, all kind of equipment or facility including controller and its panel requires explosive proof. The control panel, which is currently used as explosive proof, has been used as the air injection method by manually from outside to constantly keep the temperature and pressure between inside and outside of the panel. In this paper, we propose the design of integrated controller of explosive proof panel which can control pressure and temperature automatically.

A Case of Rapidly Developed Obesity Hypoventilation Syndrome in a Patient with Kyphoscoliosis (척추후측만증 환자에서 급속히 진행된 비만성 저환기 증후군 1례)

  • Kim, Min Young;Jeong, Jee Sun;Jang, Yu Na;Go, Se-eun;Lee, Sang Haak;Moon, Hwa Sik;Kang, Hyeon Hui
    • Sleep Medicine and Psychophysiology
    • /
    • v.22 no.1
    • /
    • pp.30-34
    • /
    • 2015
  • Obesity hypoventilation syndrome (OHS) is characterized by severe obesity, excessive daytime sleepiness, hypoxemia and hypercapnea. Because OHS mimics pulmonary hypertension or cor pulmonale, clinicians should recognize and treat this syndrome appropriately. A 58-year-old female visited the emergency room because of dyspnea. She was obese and had kyphoscoliosis. The patient also experienced snoring, recurrent choking during sleep and daytime hypersomnolence which worsened after gaining weight in the recent year. The arterial blood gas analysis showed she experienced hypoxemia and hypercapnea not only during nighttime but also daytime. We suspected OHS and the patient underwent polysomnography to confirm whether obstructive sleep apnea was present. During the polysomnography test, sleep obstructive apnea was observed and apnea-hypopnea index was 9.2/hr. The patient was treated with bilevel positive airway pressure therapy (BiPAP). After BiPAP for 4 days, hypoxemia and hypercapnia were resolved and she is currently well without BiPAP. We report a case successfully treated with clinical improvement by presuming OHS early in a patient who had typical OHS symptoms, even while having other conditions which could cause hypoventilation.

Prediction of Intubation after Bronchoscopy with Non-invasive Positive Pressure Ventilation Support in Patients with Acute Hypoxemic Respiratory Failure (급성 저산소혈증 환자에서 비침습적 양압환기 적용 하 기관지경 검사 후 기관 삽관의 예측 인자)

  • Song, Jae-Uk;Kim, Su-A;Choi, E Ryoung;Kim, Soo Min;Choi, Hee Jung;Lim, So Yeon;Park, So Young;Suh, Gee Young;Jeon, Kyeongman
    • Tuberculosis and Respiratory Diseases
    • /
    • v.67 no.1
    • /
    • pp.21-26
    • /
    • 2009
  • Background: Non-invasive positive pressure ventilation (NPPV) ensures adequate gas exchange during bronchoscopy in spontaneously breathing, hypoxemic patients, thus avoiding endotracheal intubation. However, in some patients, endotracheal intubation is eventually required after bronchoscopy. This study investigated the incidence of intubation and predictors of a need for emergency intubation prior to NPPV bronchoscopy initiation. Methods: On a retrospective basis, we reviewed the medical records of 36 patients (median age, 55 years; interquartile range [IQR], 43~65 years) with acute hypoxemic respiratory failure who required NPPV during bronchoscopy between January 2005 and October 2007. Results: All patients were hypoxemic (median $PaO_2/FiO_2$ ratio 155; IQR 90~190), but tolerated bronchoscopy with NPPV support. SOFA score and SAPS II score immediately before NPPV initiation were 4 (3~7) and 36 (30~42), respectively. Seventeen (47%) patients needed endotracheal intubation at a median time of 22 (2~50) hours after bronchoscopy. Patients who needed intubation after bronchoscopy had a higher in-hospital mortality (11 [65%] vs. 4 [21%], p=0.017). Upon multiple logistic regression analysis, the need for intubation after bronchoscopy was independently associated with a $P_aO_2/FiO_2$ ratio (OR, 0.961; 95% CI, 0.924~0.999; p=0.047) immediately before NPPV initiation for bronchoscopy. Conclusion: The severity of the hypoxemia immediately prior to NPPV initiation for bronchoscopy was associated with the need for intubation after bronchoscopy in patients with hypoxemic respiratory failure.

Blood Pressure Reactivity during Nasal Continuous Positive Airway Pressure in Obstructive Sleep Apnea Syndrome (폐쇄성(閉鎖性) 수면무호흡증(睡眠無呼吸症)에서 지속적(持續的) 상기도(上氣道) 양압술(陽壓術)이 혈력학적(血力學的) 변화(變化)에 끼치는 영향(影響))

  • Park, Doo-Heum;Jeong, Do-Un
    • Sleep Medicine and Psychophysiology
    • /
    • v.9 no.1
    • /
    • pp.24-33
    • /
    • 2002
  • Objectives: Nasal continuous positive airway pressure (CPAP) corrected elevated blood pressure (BP) in some studies of obstructive sleep apnea syndrome (OSAS) but not in others. Such inconsistent results in previous studies might be due to differences in factors influencing the effects of CPAP on BP. The factors referred to include BP monitoring techniques, the characteristics of subjects, and method of CPAP application. Therefore, we evaluated the effects of one night CPAP application on BP and heart rate (HR) reactivity using non-invasive beat-to-beat BP measurement in normotensive and hypertensive subjects with OSAS. Methods: Finger arterial BP and oxygen saturation monitoring with nocturnal polysomnography were performed on 10 OSAS patients (mean age $52.2{\pm}12.4\;years$; 9 males, 1 female; respiratory disturbance index (RDI)>5) for one baseline night and another CPAP night. Beat-to-beat measurement of BP and HR was done with finger arterial BP monitor ($Finapres^{(R)}$) and mean arterial oxygen saturation ($SaO_2$) was also measured at 2-second intervals for both nights. We compared the mean values of cardiovascular and respiratory variables between baseline and CPAP nights using Wilcoxon signed ranks test. Delta ($\Delta$) BP, defined as the subtracted value of CPAP night BP from baseline night BP, was correlated with age, body mass index (BMI), baseline night values of BP, BP variability, HR, HR variability, mean $SaO_2$ and respiratory disturbance index (RDI), and CPAP night values of TWT% (total wake time%) and CPAP pressure, using Spearman's correlation. Results: 1) Although increase of mean $SaO_2$ (p<.01) and decrease of RDI (p<.01) were observed on the CPAP night, there were no significant differences in other variables between two nights. 2) However, delta BP tended to increase or decease depending on BP values of the baseline night and age. Delta systolic BP and baseline systolic BP showed a significant positive correlation (p<.01), but delta diastolic BP and baseline diastolic BP did not show a significant correlation except for a positive correlation in wake stage (p<.01). Delta diastolic BP and age showed a significant negative correlation (p<.05) during all stages except for REM stage, but delta systolic BP and age did not. 3) Delta systolic and diastolic BPs did not significantly correlate with other factors, such as BMI, baseline night values of BP variability, HR, HR variability, mean SaO2 and RDI, and CPAP night values of TWT% and CPAP pressure, except for a positive correlation of delta diastolic pressure and TWT% of CPAP night (p<.01). Conclusions: We observed that systolic BP and diastolic BP tended to decrease, increase or remain still in accordance with the systolic BP level of baseline night and aging. We suggest that BP reactivity by CPAP be dealt with as a complex phenomenon rather than a simple undifferentiated BP decrease.

  • PDF

A Case of Obstructive Sleep Apnea Syndrome in Childhood (소아 폐쇄성 수면무호흡증후군 1례)

  • Lee, Seung-Hoon;Kwon, Soon-Young;Lee, Sang-Hag;Chang, Ji-Won;Kim, Jin-Kwan;Shin, Chol
    • Sleep Medicine and Psychophysiology
    • /
    • v.11 no.1
    • /
    • pp.50-54
    • /
    • 2004
  • The obstructive sleep apnea syndrome can occur due to various etiologies in children. In otherwise healthy children, adenotonsillar hypertrophy is the leading cause of childhood obstuctive sleep apnea. Obstructive sleep apnea caused by adenotonsillar hypertrophy can lead to a variety of symptoms and sequelae such as behavioral disturbance, enuresis, failure to thrive, developmental delay, cor pulmonale, and hypertension. So if obstructive sleep apnea is clinically suspected, proper treatment should be administered to the patient after diagnostic examinations. More than 80% improvement is seen in symptoms of obstructive sleep apnea caused by adenotonsillar hypertrophy in children after tonsillectomy and adenoidectomy. However, when it is impossible to treat the patient using surgical methods or residual symptoms remained after tonsillectomy and adenoidectomy, additional treatments such as weight control, sleep position change, and continuous positive airway pressure (CPAP), should be considered. This paper reports a case using weight control and Auto-PAP to control mild sleep apnea and snoring, which in long-term follow-up were not resolved after tonsillectomy and adenoidectomy for severe obstructive sleep apnea.

  • PDF

Herbst Oral Appliance for Obstructive Sleep Apnea When Uvulopalatopharyngoplasty and Nasal CPAP Failed (구개수구개인두성형술 및 지속적 기도 양압 공급치료에 실패하였으나 Herbst 구강내 장치로 효과를 보인 폐쇄성 수면 무호흡 증후군 1예)

  • Moon, Hwa-Sik;Choi, Young-Mee;Kim, Myung-Lip;Park, Young-Hak;Kim, Young-Kyoon;Kim, Kwan-Hyoung;Song, Jeong-Sup;Park, Sung-Hak
    • Tuberculosis and Respiratory Diseases
    • /
    • v.45 no.2
    • /
    • pp.457-464
    • /
    • 1998
  • This report describes a 5-month follow-up of the efficacy of Herbst oral appliance(OA) in a obstructive sleep apnea syndrome patient who has failed with uvulopalatopharyngoplasty(UPPP) and was unable to tolerate to subsequent nasal continuous positive airway pressure(CPAP) because of mouth air leak. The obstructive sleep apnea and daytime performance were markedly improved by regular home use of OA, and the patient still continues to use OA without complications. It is suggested that OA can be a successful alternative therapeutic modality in patients who are unable to tolerate to nasal CP AP, especially after UPPP.

  • PDF

Study of the standardization of mobile laboratories by comparative analysis (이동식 측정분석차량 비교분석을 통한 표준화 방안 연구)

  • Ahn, Sung-Ryoung;Kim, Sungbum;Cho, Munsik;Chun, Kwangsoo;Kwon, Yongho;Seok, Gwangseol
    • Journal of the Society of Disaster Information
    • /
    • v.9 no.3
    • /
    • pp.282-289
    • /
    • 2013
  • Mobile laboratory in the country (BL3 class) for research and technological development there has been continuous attempts . However, primarily as a feasibility problem and apply production techniques to move outside the laboratory by introducing the entire vehicle or domestic supply parts manufactured outside the shelter to the body in a way that introduces two special vehicles have been produced . Shelter in car parts production technology of positive pressure and negative pressure to secure perspective, and specific features of each facility through the analysis to find out the localization and standardization strategy direction and enhancements Check the current issue of the existing equipment was introduced and the internal structure of special vehicles the comparison function production technology at home and abroad through the analysis confirm and secure by applying advanced technology equipment and positive pressure inside the shelter facility that can be applied to the localization of the structure plan seeks to move existing analytical laboratory, equipped with the specifications of equipment Also introduced in the present state of the domestic vehicle production as portable measurement and analysis is to look for.