• Title/Summary/Keyword: 양성 및 음성 융합버전스

Search Result 3, Processing Time 0.015 seconds

Relationship Between Vergence Facility and Fusional Vergence (버전스용이와 융합버전스의 관계)

  • Shin, Hoy-Sun
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.14 no.3
    • /
    • pp.37-42
    • /
    • 2009
  • Purpose: There is uncertainty if the vergence facility would provide clinically significant supplementary information to the fusional vergence measurements. The purpose of this study was to determine the relationship between vergence facility and fusional vergence in a group of symptomatic subjects. Methods: A total of 114 symptomatic subjects aged 9 to 13 years, who passed the vision screening test, participated in this study. Vergence facility was measured with 8$\Delta$ BI/8$\Delta$ BO flipper lenses and a suppression control target, the 20/30 letter line on Vectogram 9 (Bernell, USA). Near fusional vergence was measured with a single 20/30 vertical line target by Von Graefe technique. In order to avoid excessive convergence stimulation, negative fusional vergence (NFV) range (blur, break and recovery) was measured followed by positive fusional vergence (PFV) ranges (blur, break and recovery). Results: Pearson correlations were calculated and showed no correlations between vergence facility and any of fusional vergence measurements (p>0.05). Also, there were no significant differences of vergence facility measurements on the compensating vergence that passed or failed Sheard and Morgan's criterion for comfortable vision (p>0.05). Conclusions: There was no correlation between vergence facility and fusional vergence among symptomatic subjects. Hence, both vergence facility and fusional vergence should be assessed for those with binocular dysfunction in order to make an accurate diagnosis and management plan.

  • PDF

Effects of Variation of Illumination on Visual Function Factors (조도변화가 시기능 성분에 미치는 영향)

  • Kim, Da-Young;Kim, Sang-Yeob;Cho, Hyun Gug;Moon, Byeong-Yeon
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.20 no.2
    • /
    • pp.195-200
    • /
    • 2015
  • Purpose: This study was performed in order to figure out the influence of illumination on visual function. Methods: 40 adults (male 21, female 19) of average age $23.93{\pm}1.59$ years were participated in this study. The test chart surface illumination was adjusted to 5, 50, 200, 500 and 800 lx, and then amplitude of accommodation, near point of convergence, far and near distance phoria, far and near distance fusional vergence, relative accommodation, and accommodation lag were measured at each illumination condition. Results: As illumination intensity of test chart was reduced, amplitude of accommodation was significantly decreased (p<0.05), accommodation lag was also decreased, near point of convergence was receded, and horizontal phoria showed a tendency of esodeviation. In the case of negative fusional vergence, with reduction of illumination intensity, the break point and the recovery point were decreased but in the case of positive fusional vergence, the break point was increased. The negative and positive relative accommodation were significantly decreased (p<0.05) with reduction of illumination intensity. Conclusions: In clinical practice, visual functional test should be performed under condition of adequate illumination level through patient's living environment and job.

Effect of Vision Training using Fresnel Prism Lens on Fusional Vergence and Accommodation (프레넬 프리즘렌즈를 이용한 시기능 훈련이 조절과 융합버전스에 미치는 영향)

  • Kim, Yong-Gil;Kim, Min-Kyung;Jeong, Ju-Hyun
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.17 no.2
    • /
    • pp.159-164
    • /
    • 2012
  • Purpose: Of the various methods of vision training, the essay aims to explore the effective ways of using the Fresnel prism lens in order to expand the positive fusional vergence for the patient having specific condition of convergence insufficiency or basic exophoria. Methods: 15 students of city of Daejeon university without an eye disease (average age $22.73{\pm}1.68$) were selected and underwent the subjective refraction test and binocular vision test, and recording their test results before vision training and replacing an identical frame with a lens of same quality after the full calibration, the lens was then adhered with the Fresnel prism lens and continued to train for thirty minutes daily during two weeks. Afterwards, the binocular vision test was reattempted. The observation of the change in the results of the binocular vision test in use of the fresnel prism lens in the vision training test was researched. Results: After training, the positive fusional vergence had increased to a number of $22.27{\pm}2.26$ $\Delta$, to 7.80 $\Delta$, at near, the fused cross cylinder test increased to an average of $0.55{\pm}0.09$ D, 0.40 D after training, showing a normal result. The value of negative relative accommodation after training had an average of $2.22{\pm}0.08$D, showing that 0.42 D had increased. The value of near point of convergence after training had an average of $6.13{\pm}0.53$ cm, showing that 2.80 cm had decreased. To patients who had convergence insufficiency or basic exophoria, the value of the near vision test that used the Fresnel prism lens which was able to expand BO positive fusional vergence had increased without phoria. Conclusions: The changes were tested and the effectiveness of the Fresnel prism lens, due to the nature of the lens itself, helped with both cosmetic effects and cost. It also allows good optical correction effects, in addition to these clinical effects indicated before. Therefore, it may be determined that the Fresnel prism lens binocular vision therapy for patients is more popular and highly recommended.