Operation of Night Vision Goggle for Aircraft (항공기 야간투시경 운용)

  • Kwon, Jong-Kwang;Kim, Whan-Woo
    • Journal of the Korea Institute of Military Science and Technology
    • /
    • v.9 no.2 s.25
    • /
    • pp.34-41
    • /
    • 2006
  • This paper describes the general considerations and operational applications of aircraft night vision goggle(NVG). The operators should recognize the NVG characteristics, natural night light sources and interoperability between them. And they have to keep attention to the method to take steps to avoid misperceptions, illusions during flight, and the negative impact on the effectiveness and safety of the mission. The considerations based on the interoperability between NVG and night operation suggest the evaluation items of NVG field test and flight test.

Development of Night Vision Imaging System for the KO-1 Aircraft (저속통제기 야시조명계통 개발)

  • Gwon, Jong-Gwang
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.34 no.5
    • /
    • pp.107-116
    • /
    • 2006
  • This paper deals with a development of night vision imaging system(NVIS) for the KO-1 aircraft. In the modern combat, NVIS has a tendency to be applied for night peculiar mission and pilot mission maximization. KO-1 aircraft, which was the first domestic applied NVIS, is forward air control acquired information of day/night enemy(foe) site and moving of enemy for low altitude flight. We have successfully finished a developmental requirement/criterion, development of system, and construction of test and evaluation through development of NVIS for the KO-1 aircraft. KO-1 aircraft is acquired timely initial operational capability.

Polychromatic OTF measurement of an optical system using a white light source (백색광원을 이용한 광학계의 polychromatic OTF 측정)

  • Song, Jong-Sub;Lee, Yoon-Woo;Cho, Hyun-Mo;Lee, In-Won;Cho, Jae-Heung;Jang, Soo;Im, Chun-Seok
    • Proceedings of the Optical Society of Korea Conference
    • /
    • 2001.02a
    • /
    • pp.82-83
    • /
    • 2001
  • 카메라, 망원경 등의 일반 광학제품 뿐만 아니라 야시경, 열상장비 등의 적외선 결상장치, 수중이나 항공기에서 사용되는 첨단 광학기기들은 종류나 용도가 아주 다양하여 사용목적에 적합한 광학계를 설계하거나 새로운 광학계를 개발하기 위해서는 그 성능을 정확하게 평가하는 것이 매우 중요하다. 현재까지 많은 경우에 있어서 렌즈나 광학계는 다색광원(polychromatic illuminant)에서 사용되도록 설계되어 지고 있고 또한 광학계를 통해 맺혀지는 상도 색감각을 갖는 반응체(사람의 눈, 필름 등)에 의해 평가되어 진다. (중략)

  • PDF

부산항 항로표지 영상감시시스템 구축 사례

  • An, Hyeon-Gyu;Lee, Tae-Gyeong
    • Proceedings of the Korean Institute of Navigation and Port Research Conference
    • /
    • 2017.11a
    • /
    • pp.151-153
    • /
    • 2017
  • 해상 특성으로 야간에 항로표지 충돌사고가 빈번하게 발생함에 따라 야간에도 주간처럼 사물 식별이 가능한 영상정보를 확인할 수 있는 고성능 촬영장비 도입하고 부산항 주요항로에 운영되고 있는 항로표지시설의 주 야간 상태 정보를 감시하여 항로표지 고시기능 유지 여부를 확인하고 선박 충돌에 의한 등부표 사고 발생시 가해선박을 색출하여 원인자에게 피해시설을 복구토록 함.

  • PDF

Development of Wide-Range Brightness Controller of LED Backlight for Avionic Displays (항공기 디스플레이용 LED 백라이트의 광대역 휘도 제어기 개발)

  • Lim, Soo-Hyun;Lim, Jeong-Gyu;Chung, Se-Kyo;Shin, Hwi-Beom;Shin, Min-Jae;Sohn, Seung-Gul
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.13 no.4
    • /
    • pp.287-294
    • /
    • 2008
  • This paper describes an implementation of a wide-range dimming controller of a LED backlight for Avionics applications such as a control display unit(CDU) and multi-function display(MFD). The digital dimming controller employing a current controlled buck converter and light sensor feedback is proposed. The proposed system provides a wide dimming control range of from 150fL to 0.05fL(3000:1) required for avionic displays. The experimental results are provided to show the control performance.

Development and Design of the Optical System of a Night Scope (Night Scope 광학계의 설계 및 개발)

  • Lee, Dong-Hee;Lim, Yang-Moo
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.9 no.1
    • /
    • pp.11-17
    • /
    • 2004
  • We tried to design and manufacture a night scope which is used in the leisure sports field. The whole system consists of an IR light source part, an objective lens part, an intensifier tube part and an eye_piece lens part. We designed an objective lens part to the infinite object imaging optical-system with 80mm focal-length, 40mm effective-aperture and 14mm image-field-size of which the chromatic aberration is reduced by using materials of BK7 and FD4. The resolution of this system is about 25lines/mm at the 40% MTF value criterion. The eye_piece lens is adopted goods to be used commercially to save cost of production. The design technique which gets in this development will be utilized greatly in good developments of the dot, the sight and the day/night riflescope system at the hereafter.

  • PDF

Electronic Circuit Design for Portable Infrared Night Vision Scope (휴대용 적외선 야시경을 위한 전자회로설계)

  • Eom Ki-Hwan;Kim Doo-Hwan
    • Journal of the Institute of Electronics Engineers of Korea SC
    • /
    • v.43 no.2 s.308
    • /
    • pp.33-39
    • /
    • 2006
  • This paper designed the electronic circuit part of Potable Infrared Night Vision Scope for a small size, light weight, and low power. Designed electronic circuit part is composed of an Auto Voltage Selecting Module, and a Power Supply Module. An Auto Voltage Selecting Modulo is composed of a switch, a battery, a step up voltage part, and a selecting voltage part. A Power Supply Module is composed of a high luminous sensing part, a battery voltage sensing part, a infrared illumination part, a connection sensing part, and a power control part. And this module controls the power of Image Intensifier Tube. To verify the performance of the designed electronic circuit part, we experimented the consumption power and continuous using time. Experimental results show that the designed electronic circuit part improves considerably on the performance of the AN/PVS-14. performance.

The Diagnosis of Pneumoniae Following Bone Marrow Transplantation by Bronchoscopy (골수이식후 기관지내시경을 이용한 폐렴의 진단)

  • Kim, Tae-Yon;Yoon, Hyeong-Kyu;Moon, Hwa-Sik;Park, Sung-Hak;Min, Chang-Ki;Kim, Chun-Choo;Jung, Jung-Im;Song, Jeong-Sup
    • Tuberculosis and Respiratory Diseases
    • /
    • v.49 no.2
    • /
    • pp.198-206
    • /
    • 2000
  • Background : Pulmonary complications following bonemarrow transplantation (BMT) are common and associated with a high mortality rate. We investigated the yield, safety, and impact of fiberoptic bronchoscopy (FOB) for diagnosis of postBMT pneumoniae. Methods : From May 1997 to April 2000, 56 FOBs were performed in 52 post BMT patients for clinical pneumoniae. BMT patients with respiratory symptoms and/or pulmonary infiltrates had a thoracic HRCT(high resolution computed tomography) and bronchoscopic examination including BAL (bronchoalveolar lavage), TBLB (transbronchial lung biopsy), PSB (protected specimen brush). Results : The characteristics of the subjects were as follows : 37 males, 15 females, mean age of 31.3 years(l7-45), 35 sibling donor allogenic BMTs, 15 nonrelated donor allogenic BMTs, and 2 autologous BMTs. Fiftynine percent of FOBs (33 FOBs, 31 patients) were diagnostic. Isolated pathogens included the following : 12 cytomegalovirus (CMV) (21.4 %), 7 pneumocystis carinii (PC) (12.5 %), 11 CMV with PC (19.6 %), 2 Mycobacaterium tuberculosis (3.6%), and 1 streptococcus (1.8%). Most of the radiographic findings were diffuse interstitial lesions. CMV pneumoniae had mainly diffuse interstitial nodular lesion, and PC pneumoniae had diffuse, interstitial ground glass opacity(GGO). When CMV was accompanied by PC, a combined pattern of nodular and GGO was present. Of the 56 cases (23.2%), 13 died of CMV pneumoniae (n=2), PCP (n=2),mixed infection with CMV and PC (n=3), underlying GVHD (n=1), underlying leukemia progression (n=1), or respiratory failure of unknown origin (n=4). There was no major complication by bronchoscopy. Only 3 cases developed minor bleeding and 1 episode temporary hypoxemia. Conclusion : Based on our findings, CMV and PC are the major causes of postBMT pneumoniae. In addition, BAL can be considered a safe and accurate procedure for the evaluation of pulmonary complications after BMT.

  • PDF

A Case of Bronchial Foreign Body Misdiagnosed as Bronchial Asthma (기관지천식으로 오인된 기관지내 이물 1예)

  • Lee, Byoung Jun;Lee, Young Woo;Jung, Jae Woo;Shin, Jong Wook;Kim, Jae Yeol;Park, In Won;Choi, Byoung Whui
    • Tuberculosis and Respiratory Diseases
    • /
    • v.57 no.5
    • /
    • pp.484-488
    • /
    • 2004
  • In adults, aspiration of foreign bodies into tracheobronchus is sometimes presented atypically, mimicking chronic pulmonary diseases such as bronchial asthma, pneumonia, or empyema, especially without notice of aspiration or choking. In such cases, diagnosis and adequate treatments are often delayed. Suspicion of foreign body aspiration and computed tomography and bronchoscopic examination make correct diagnosis more early. We report a case of bronchial foreign body, which had been misdiagnosed as bronchial asthma with wheezing in the whole lung filed, and reversible airway obstruction in the spirometry.

Development of Prism Dot-sight Combined with Thermal Imaging Camera (열영상 카메라가 결합된 프리즘 도트사이트 개발)

  • Park, Seung-Hwan;Jung, Bo-Seon;Lee, Dong-Hee
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.19 no.4
    • /
    • pp.479-485
    • /
    • 2014
  • Purpose: This study relates to the development of the prism dot-sight combined with the thermal imaging camera. Methods: We have placed a reflector designed to the doublet type in the front of a BS (beam splitting) prism, have placed an OLED panel and a dot reticle generator to the top and bottom of the reflecting surface of the BS prism, and have placed a detachable magnifier between the BS prism and the observer by which the observer can see the magnified image of the OLED panel. By doing this, we were able to configure the new type prism dot-sight combined with the thermal imaging camera. Results: By placing the removable magnifier designed with a new type between the BS prism and the observer, we could design the new type prism dot-sight which performs the role of the dot sight by removing the magnifier during the day-time, and performs the role of the night scope during the night-time by which we can observe the enlarged image of the thermal imaging camera through the BS prism by attaching the removable magnifier. Conclusions: In this study, we have developed the prism dot-sight combined with the thermal imaging camera which is able to play the role of the day or night scope selectively, by disposing the designed magnifier characterized by the focal length of 44 mm, the viewing angle of ${\pm}7.0^{\circ}$, and the MTF value of 0.5 or more at the criterion of 50 lp/mm and the 0.7 field between the BS prism and the observer. By doing so, we could design and fabricate the new type prism dot-sight combined with the thermal imaging camera which can further increase the rapidity of firing and provide more convenience in the mounting of a firearm than the detachable combination of an existing dot sight and an existing night scope.