A Study on the Standard for the Safety Zone in the Domestic LNG TTS Bunkering (국내 LNG TTS 벙커링 시 안전구역 기준에 관한 연구)

  • Park, Sung-In;Roh, Jae Seung;Park, Jaehee;Park, Kyoungmin;Shin, Dongkyu
    • Journal of the Society of Naval Architects of Korea
    • /
    • v.59 no.5
    • /
    • pp.323-329
    • /
    • 2022
  • This paper suggests an example guideline of a safety zone layout for the domestic LNG Truck-To-Ship (TTS) bunkering. The safety zone is one of the controlled area in LNG bunkering and its layout is required as a fundamental safety barrier. While the international standard provides a layout methodology of the safety zone, its detail application is not user-friendly and only possible with a level of the process engineering. In the domestic case, the enforcement regulations are applied for LNG bunkering but the safety zone is not properly defined for TTS operation. Considerations are made for the intuitive approach of the safety zone layout and an example guideline is suggested for application in the domestic TTS bunkering. A technical background of the guideline is described and its applicability is demonstrated with regard to the characteristics of TTS bunkering. The findings of the study are summarized in association with a practical layout of the safety zone, contributing to the safety culture in the domestic LNG bunkering.

Experimental examination for effect of voids on bonding performance in cryogenic temperature condition (내부 기공이 극저온에서 접착강도에 미치는 영향에 대한 실험적 고찰)

  • Shon, Min-Young;Kim, Jong-Ho;Kim, Jong-Hak
    • Composites Research
    • /
    • v.22 no.2
    • /
    • pp.14-17
    • /
    • 2009
  • Adhesive joints are widely used for structural joining applications in various fields and environmental conditions. Polyurethane adhesive is using for LNG carrier with cryogenic temperature condition. In industrial application of polyurethane adhesive, void of adhesive layer is often discussed regarding its effects on bonding properties. In present study, artificial void were prepared on Polyurethane adhesive layer with various size and location. The single lap shear test was carried out by using prepared specimens under $-170^{\circ}C$. As a result, it was confirm that the void of adhesive layer didn't affect the adhesion properties independent of their size and location.

Separation of Electronic Grade Highly Pure Carbon Dioxide Using Combined Process of Membrane, LNG Cold Heat Assisted Cryogenic Distillation (분리막 공정과 LNG 냉열 및 심냉 증류를 이용한 전자급 고순도 이산화탄소의 분리)

  • YOUNGSOO KO;KYUNGRYONG JANG;JUNGHOON KIM;YOUNGJOO JO;JUNGHO CHO
    • Transactions of the Korean hydrogen and new energy society
    • /
    • v.35 no.1
    • /
    • pp.90-96
    • /
    • 2024
  • In this paper, a new technology to obtain electronic grade, highly pure carbon dioxide by using membrane and liquefied natural gas (LNG) cold heat assisted cryogenic distillation has been proposed. PRO/II with PROVISION release 2023.1 from AVEVA company was used, and Peng-Robinson equation of the state model with Twu's alpha function to predict pure component vapor pressure versus temperature more accurately was selected for the modeling of the membrane and cryogenic distillation process. Advantage of using membrane separation instead of selecting absorber-stripper configuration for the concentration of carbon dioxide was the reduction of carbon dioxide capture cost.

Performance Analysis of a Combined Power Cycle Utilizing Low-Temperature Heat Source and LNG Cold Energy (저온 열원 및 LNG 냉열을 이용하는 복합 발전 사이클의 성능 해석)

  • Kim, Kyoung-Hoon;Oh, Jae-Hyeong;Ko, Hyung-Jong
    • Transactions of the Korean hydrogen and new energy society
    • /
    • v.23 no.4
    • /
    • pp.382-389
    • /
    • 2012
  • Power generation cycle using ammonia-water mixture as working fluid has attracted much attention because of its ability to efficiently convert low-temperature heat source into useful work. If an ammonia-water power cycle is combined with a power cycle using liquefied natural gas (LNG), the conversion efficiency could be further improved owing to the cold energy of LNG at $-162^{\circ}C$. In this work parametric study is carried out on the thermodynamic performance of a power cycle consisted of an ammonia-water Rankine cycle as an upper cycle and a LNG cycle as a bottom cycle. As a driving energy the combined cycle utilizes a low-temperature heat source in the form of sensible heat. The effects on the system performance of the system parameters such as ammonia concentration ($x_b$), turbine 1 inlet pressure ($P_{H_1}$) and temperature ($T_{H_1}$), and condenser outlet temperature ($T_{L_1}$) are extensively investigated. Calculation results show that thermal efficiency increases with the increase of $P_{H_1}$, $T_{H_1}$ and the decrease of $T_{L_1}$, while its dependence on $x_b$ has a downward convex shape. The changes of net work generation with respect to $P_{H_1}$, $T_{H_1}$, $T_{L_1}$, and $x_b$ are roughly linear.

On-Road Investigation of PM Emissions of a City-Buses Fuelled by Diesel, CNG, and LPG Using a Mobile Emission Laboratory (이동형 배출가스 측정시스템(MEL)을 이용하여 디젤, CNG, LPG 시내버스에서 배출되는 입자상 물질 평가)

  • Lee, Seok-Hwan;Kim, Hong-Suk;Park, Jun-Hyuk;Yoon, Jun-Kyu
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.35 no.4
    • /
    • pp.409-416
    • /
    • 2011
  • A mobile emission laboratory (MEL) was designed to measure the amount of traffic pollutants with high temporal and spatial resolution under real conditions. Equipment for gas-phase measurements of quantity of CO, NOx, $CO_2$, and THC and for the measurement of the number density and size distribution of fine and ultra-fine particles by a FMPS and a CPC were placed in a mini-van. The exhaust of different type of vehicles can be sampled by MEL. This paper describes the construction and technical details of the MEL and presents data from the experiment in which a car chases city buses fuelled by diesel, CNG, and LPG. The diameters of most particles in the exhaust of the diesel city bus were less than 300 nm and most of the particles had a diameter of 30-60 nm. However, most particles in the exhaust of the CNG and LPG city buses were nanoparticles (diameter: less than 50 nm).

A Development of Representative Condition Evaluation Standard for LNG Storage Tank Structures (LNG 저장탱크 구조물의 종합적 상태평가기준 개발)

  • Kim, Jung-Hoon;Jo, Young-Do
    • Journal of the Korean Institute of Gas
    • /
    • v.22 no.6
    • /
    • pp.44-51
    • /
    • 2018
  • As the LNG storage tank is aged, if there is a crack in the outer wall concrete or corrosion of the reinforcing steel, there is a risk of a major accident such as collapse of the structure depending on the type and degree of damage. Since 2014, LNG storage tanks have undergone precise safety diagnosis and safety inspection has been carried out. The condition evaluation criteria for each component have been revised and applied in January 2016. The condition evaluation standard is to evaluate the status of storage tanks based on the appearance survey and material test results of LNG storage tanks and it is important for maintenance. In addition, the representative condition evaluation standard that shows the comprehensive state of each LNG storage tank is important in maintenance, but the related standard for LNG storage tank outer concrete is not available in Korea and abroad, and development of the condition evaluation standard is necessary. In this paper, we examined the structural characteristics of LNG storage tanks, analyzed the status of the condition evaluation criteria for each member, and developed a comprehensive status rating system by weighting the members. We used the AHP(Analytic Hierarchy Process) technique and developed a representative conditon evaluation criteria through surveys of professional organizations.

Comparative Study on the Thermal Insulation of Membrane LNG CCS by Heat Transfer Analysis (열전달 해석을 이용한 멤브레인형 LNG 화물창의 단열구조 성능비교)

  • Hwang, Se-Yun;Lee, Jang-Hyun
    • Journal of the Computational Structural Engineering Institute of Korea
    • /
    • v.29 no.1
    • /
    • pp.53-60
    • /
    • 2016
  • This study discusses the thermal insulation capacity of variant of NO96 LNG (liquefied natural gas) cargo containment insulation system. Changing the insulation materials and the insulation layers of conventional GTT NO96 containment system, The thermal resistance and BOR(boil off rate) caused by the heat transfer between cryogenic and environmental temperature is discussed. Therefore, thermal analysis of LNG CCS(cargo containment system) is carried out to determine the insulation capabilities. Also, BOR is evaluated in terms of the total amount of heat invaded into CCS(cargo containment system). Variant of NO96 CCS such as NO96, NO96GW and NO96L3 membrane type during laden voyage is selected for the comparative study. Finite element model for heat transfer analysis is conducted by employing the equivalent thermal resistance model to simplify the complex insulation layers. Finally the results for each variant model are relatively compared and discussed to minimize the BOR.

Investigation of ground condition charges due to cryogenic conditions in an underground LNG storage plant (지하 LNG 저장 시험장에서 극저온 환경에 의한 지반상태 변화의 규명)

  • Yi Myeong-Jong;Kim Jung-Ho;Park Sam-Gyu;Son Jeong-Sul
    • Geophysics and Geophysical Exploration
    • /
    • v.8 no.1
    • /
    • pp.67-72
    • /
    • 2005
  • To investigate the feasibility of a new concept of storing Liquefied Natural Gas (LNG) in a lined hard rock cavern, and to develop essential technologies for constructing underground LNG storage facilities, a small pilot plant storing liquid nitrogen (LN2) has been constructed at the Korea Institute of Geoscience and Mineral Resources (KIGAM). The LN2 stored in the cavern will subject the host rock around the cavern to very low temperatures, which is expected to cause the development of an ice ring and the change of ground condition around the storage cavern. To investigate and monitor changes in ground conditions at this pilot plant site, geophysical, hydrogeological, and rock mechanical investigations were carried out. In particular, geophysical methods including borehole radar and three-dimensional (3D) resistivity surveys were used to identify and monitor the development of an ice ring, and other possible changes in ground conditions resulting from the very low temperature of LN2 in the storage tank. We acquired 3D resistivity data before and after storing the LN2, and the results were compared. From the 3D images obtained during the three phases of the resistivity monitoring survey, we delineated zones of distinct resistivity changes that are closely related to the storage of LN2. In these results, we observed a decrease in resistivity at the eastern part of the storage cavern. Comparing the hydrogeological data and Joint patterns around the storage cavern, we interpret this change in resistivity to result from changes in the groundwater flow pattern. Freezing of the host rock by the very low temperature of LN2 causes a drastic change in the hydrogeological conditions and groundwater flow patterns in this pilot plant.

Efficient Spent Sulfidic Caustic wastewater treatment using Adsorption Photocatalysis System (흡착광산화 시스템을 이용한 효과적인 SSC 페수처리)

  • Kim, Jong Kyu;Lee, Min Hee;Jung, Yong Wook;Joo, Jin Chul
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2016.05a
    • /
    • pp.520-520
    • /
    • 2016
  • 석유 화학공장에서 발생하는 spent sulfidic caustic (SSC) 폐수는 액화석유가스(LPG)나 천연가스(NG)의 정제과정에서 발생되는 것으로 고농도의 sulfide와 cresylic, phenolic 그리고 mercaptan 등이 포함된 독성과 냄새를 유발하는 물질이다. 이러한 물질들은 LPG나 NG의 정제과정에서 높은 산도를 가진 휘발성 황화합 물질들을 제거하기 위해 사용된 NaOH가 $H_2S$와 반응하여 발생하는 것이다. 진한 갈색 또는 검은색을 띄는 SSC 폐수는 12 이상의 높은 pH를 가지고 있으며 5~12 wt%의 높은 염분도를 가지고 있다. 또한 강한 부식성과 독성을 가진 황화합물의 농도가 1~4 wt%이며, 방향족 탄화수소 물질 (i.e. methanethiol, benzene, tolune and phenol)들도 다량 함유되어 있다. 따라서 이러한 유해 물질들은 기존의 하수처리 공정으로 방류하기 전에 완벽하게 처리해야만 하수처리 공정의 오염 부하량을 줄일 수 있다. 습식산화공정은 SSC 폐수를 처리하기 위해 흔히 사용되고 있는 물리-화학적 처리 공정이지만 고비용, 고에너지가 필요하며, 고온 및 고압에서만 작동되어 안전상의 문제점을 갖고 있다. 또한 습식산화공정을 거친 폐수는 배출허용기준을 만족하기 위해 생물학적 2차 처리가 반드시 필요하다. 철-과산화수소를 이용하는 펜톤산화 공정, 그리고 sulfide를 sulfate로 전환시키는 생물학적 처리 공정은 황화합물의 완전한 무기물화가 힘들며, 현장 적용 시 기술적 경제적 부담이 크다. 이러한 단점을 극복하고, SSC 폐수를 효과적으로 처리하기 위해 본 연구는, 높은 흡착력과 광산화력을 가진 흡착광산화 반응 시스템(Adsorption Photocatalysis System, APS)을 개발하였다. APS는 SSC 폐수를 시스템 내부로 유입하여 수중의 오염물질을 흡착광산화제로 구성된 반응구조체가 흡착하고, 흡착된 오염물질을 UV에너지와 이산화티타늄 광촉매의 광화학반응에 의해 최종적으로 무해한 물질로 환원시키는 폐수처리시스템이다. APS의 반응구조체는 태양에너지 및 인공에너지원에 의해 활용 가능하며, 난분해성 유기화합물질을 물과 이산화탄소로 분해할 수 있는 친환경적이고 경제적인 소재로서 널리 쓰이고 있는 이산화티타늄 광촉매와 화력발전소의 높은 소성온도에 의해 연소된 후 발생되는 bottom ash를 이산화티타늄의 지지체로 사용하여 높은 흡착력과 광촉매 산화력을 가진 복합물이다. 개발된 APS에 의해 SSC 폐수를 처리한 결과, COD 86.1%, 탁도 98.4%, sulfide 99.9%의 높은 처리효율을 보여주고 있다. 따라서 본 연구를 통해 개발된 APS는 강한 부식성과 독성 그리고 높은 농도를 가지고 있는 SSC 폐수를 효과적으로 처리할 수 있다.

  • PDF

Application of Seismic Isolation and Vibration Control in Korea (우리나라의 면진 및 진동제어)

  • Lee, Dong-Guen;Kim, Tae-Ho
    • Journal of the Earthquake Engineering Society of Korea
    • /
    • v.10 no.6 s.52
    • /
    • pp.67-77
    • /
    • 2006
  • Seismic activity of Korea is not so high as that of Japan or California and most of the structures were designed without considering the influence of earthquakes until the first seismic design code was enforced in 1988. Therefore, it was very hard to find seismically isolated structures in Korea until 1980's. Korean engineers assumed that the seismic isolation or vibration control would be useful only in a high seismicity region while such technologies can be quite useful in a low seismicity region for the efficient reduction of earthquake damages. Recently, Korean engineers began to have interest in the seismic isolation or vibration control and applied it to some important structures such as LNG storage tanks, many bridges and several buildings. However, design codes are not defining such useful advanced technologies for the design of building structures and several projects employing seismic isolation or vibration control in the design of structures had difficulties in obtaining construction permit from the local government. Therefore, it is an urgent requirement to introduce these advanced technologies in the seismic design code.