• Title/Summary/Keyword: 액체-구조물 연계

Search Result 10, Processing Time 0.022 seconds

Dynamic Suppression Effects of Liquid Container to the Baffle Number and Hole Diameter (배플개수 및 내경변화에 따른 액체 저장탱크의 동억제 효과)

  • 조진래;김민정;이상영;허진욱
    • Journal of the Computational Structural Engineering Institute of Korea
    • /
    • v.15 no.1
    • /
    • pp.147-154
    • /
    • 2002
  • The dynamic load caused by sloshing of internal fluid severely affects the structural and control stabilities of cylindrical liquid containers accelerating vertically. If the sloshing frequency of fluid is near the frequency of control system or the tank structure, large dynamic force and moment act on launching vehicles. For the suppression of such dynamic effects, generally flexible ring-type baffles are employed. In this paper, we perform the numerical analysis to evaluate the dynamic suppression effects of baffle. The parametric analysis is performed with respect to the baffle inner-hole diameter and two different baffle spacing types : equal spacing with respect to the tank and one with respect to the fluid height. The ALE (arbitrary Lagrangin-Eulerian) numerical method is adopted for the accurate and effective simulation of the hydrodynamic interaction between fluid and elastic structure.

Analytical Study on Free Vibration of Cylindrical Liquid-Storage Tanks (원통형 액체저장탱크의 고유진동에 대한 이론적 연구)

  • Lee, Jin-Kyu;Lee, Sang-Young;Kim, Ki-Whan;Cho, Jin-Rae;Park, Tae-Hak;Lee, Woo-Yong
    • Proceedings of the KSME Conference
    • /
    • 2000.04a
    • /
    • pp.602-607
    • /
    • 2000
  • Fuel-storage tank is a representative example of liquid-structure interaction systems. In order to prevent the undesired structural failure by a variety of external loads, the reliable analysis of the dynamic response of such structural system is of a great importance. In this paper, we address the analytical study on free vibration of axisymmetric cylindrical fuel-storage tanks together with the parametric investigation of eigen-characteristics with respect to the relative fuel fill-height and the relative tank height. Numerical results illustrating theoretical results are also included.

  • PDF

Effect of Fluid Added Mass on Vibration Characteristics and Seismic Responses of Immersed Concentric Cylinders (유체속에 잠긴 동축원통 구조물의 진동특성 및 지진응답에 대한 유체부가질량 영향)

  • 구경회;이재한
    • Journal of the Earthquake Engineering Society of Korea
    • /
    • v.5 no.5
    • /
    • pp.25-33
    • /
    • 2001
  • For the seismic design and analysis of LMR(liquid metal reactor) being developed in Korea, it is necessary to develop the simple seismic analysis model including the fluid-structure interaction effects. In this paper, the theoretical backgrounds for the fluid added mass of the immersed concentric cylinders are investigated and the seismic analysis code using the Runge-Kutta algorithm, which can consider the fluid added mass matrix in system matrix, are developed to perform the time history seismic analysis. Form the coupled modal analysis and the seismic analysis for the simple immersed concentric cylinders, it is verified that the fluid added mass significantly affect the vibration characteristics and the seismic responses. Therefore the fluid coupled effects should be carefully considered in seismic response analysis of the immersed concentric cylinders.

  • PDF

Transient Response Analysis of Cylindrical Liquid Fuel-Storage Tank subject to Initial Acceleration (원통형 액체 연료탱크의 초기 가속에 따른 과도응답 해석)

  • Lee, S.Y.;Joo, Y.S.;Kim, K.W.;Cho, J.R.
    • Proceedings of the KSME Conference
    • /
    • 2000.11a
    • /
    • pp.475-480
    • /
    • 2000
  • The transient dynamic-response analysis of fuel-storage tanks of flying vehicles accelerating in the vertical direction is achieved with finite element method. A fuel-storage tank is a representative example of the fluid-structure interaction problem, in which structure and fluid media interact strongly. For the accurate analysis of this complicated fluid-structure system, we employed ALE(arbitrary Lagrangian-Eulerian) coupling method. Two types of fuel-storage tanks, one with two baffles and the other without baffle, are considered to examine the effect of baffles. The fuel-storage tank with baffles shows more uniform hydrodynamic pressure distribution, resulting effective stress in structural region and faster convergence from transient to steady states. MSC/Dytran, a commercial FEM software for the 3D coupled dynamic analysis, is used for this analysis.

  • PDF

Dynamic Characteristic of A Bi-dirctional Damper Using A Tuned Mass Damper and A Tuned Liquid Column Damper (TMD와 TLCD를 이용한 2방향 감쇠기의 동적특성)

  • Lee, Sung-Kyung;Min, Kyung-Won;Park, Eun-Churn
    • Journal of the Computational Structural Engineering Institute of Korea
    • /
    • v.21 no.6
    • /
    • pp.589-596
    • /
    • 2008
  • This study introduces the design of a bi-directional damper using a tuned mass damper(TMD) and a tuned liquid column damper(TLCD) and presents experimental verifications to confirm its control performance. The damper used in this study behaves as a TMD in a specific translational direction and acts as a TLCD in the other orthogonal direction. First, shaking table test is performed to investigate the coupled effect of control forces produced by TMD and TLCD. Then, the parameters that affect to dynamic characteristics of the proposed damper are quantitatively evaluated based on the experimental results. Testing results shows that the damper used in this study produces control forces coupled by TLCD and TMD, as it is excited by waves with an incident angle. Also, it is observed that the damper can be used to reduce bi-directional responses of building structures.

Dynamic Response Analysis of Baffled Fuel-Storage Tank in Turnaround Motion (선회운동에 따른 배플형 연료탱크의 동응답 해석)

  • 조진래;홍상일;김민정
    • Journal of the Computational Structural Engineering Institute of Korea
    • /
    • v.16 no.1
    • /
    • pp.77-86
    • /
    • 2003
  • Dynamic response of baffled fuel-storage tank in turnaround motion is simulated using the ALE finite element method. Fuel-storage tank undergoes abrupt impact load caused by inertia force of internal fuel in turnaround motion. Also, large dynamic force and moment caused by this load influence structural stability and control system. In this paper, ring-type baffles are adopted to suppress the dynamic influence. Through the parametric analysis with respect to the baffle number and location, the effects of baffle on the dynamic response of baffled fuel-storage tank is analyzed. The ALE finite element method is adopted for the accurate and effective simulation of the hydrodynamic interaction between fluid and structure.

Numerical Formulation of Axisymmetric Shell Element and Its Application to Geotechnical Problems (축대칭 쉘 요소의 유한요소 수식화와 지반공학적 활용)

  • Shin, Hosung;Kim, Jin-Wook
    • Journal of the Korean Geotechnical Society
    • /
    • v.36 no.12
    • /
    • pp.27-34
    • /
    • 2020
  • Use of axisymmetric shell element for the structure increases the efficiency and accuracy in finite element analysis of the interaction between the ground and the structure. This paper derived the force balance equation and the moment balance equation for an axisymmetric shell element based on Kirchhoff's theory. The governing equation for the axial deformation used the isoparametric shape function in the Galerkin formulation, and the governing equation for the shell bending used the higher-order shape function. The developed axisymmetric shell element was combined with Geo-COUS, a geotechnical finite element program for the coupled analysis with the ground. The accuracy of the developed element was confirmed through the example analyses of the circular plate and the liquid storage tank. And the energy balance equation for the axisymmetric shell element is presented.

Finite Element Analysis for Evaluation of Viscous and Eccentricity Effects on Fluid Added Mass and Damping (유체 부가질량 및 감쇠 결정시 점성 및 편심 영향에 대한 유한요소해석)

  • 구경회;이재한
    • Journal of the Earthquake Engineering Society of Korea
    • /
    • v.7 no.2
    • /
    • pp.21-27
    • /
    • 2003
  • In general, simple fluid added mass method is used for the seismic and vibration analysis of the immersed structure to consider the fluid-structure interaction effect. Actually, the structural response of the immersed structure can be affected by both the fluid added mass and damping caused by the fluid viscosity. These variables appeared as a consistent matrix form with the coupling terms. In this paper, finite element formula for the inviscid fluid case and viscous fluid case are derived from the linearized Navier Stoke's equations. Using the finite element program developed in this paper, the analyses of fluid added mass and damping for the hexagon core structure of the liquid metal reactor are carried out to investigate the effect of fluid viscosity with variation of the fluid gap and Reynolds number. From the analysis results, it is verified that the viscosity significantly affects the fluid added mass and damping as the fluid gap size decrease. From the analysis results of eccentricity effect on the fluid added mass and damping of the concentric cylinders, the fluid added mass increase as the eccentricity increases, however the fluid damping increases only when the eccentricity is very severe.

A Study on the Integrated Control and Safety Management System for a LNG Storage Tank (LNG 저장탱크의 통합제어 안전관리 시스템에 관한 연구)

  • Kim Chung Kyun
    • Journal of the Korean Institute of Gas
    • /
    • v.9 no.1 s.26
    • /
    • pp.44-50
    • /
    • 2005
  • This paper presents integrated control and safety management system for a LNG storage tank. This system is for collecting and analyzing the temperature, pressure, and vibration signals in which are used to control and guarantee the system safety and leakage control from the inner gas tank. Based on the investigations of LNG tank related failures and accidents, we strongly recommend the modification and new development of current safety related measuring and control systems because the LNG tank is constructed bigger and bigger in recent years for the efficiency and safety increments. Thus, this paper presents newly developed integrated control and safety management system for a large LNG storage tank. This system provides the enhanced measuring and control systems, and new displacement based safety system, which may detect and control the deformation properties of tank structures. In addition, we recommend that the new integrated control and safety management system should be coupled by process integrated innovation system (PIIS) for an increased safety, efficiency, and productivity of LNG tanks.

  • PDF

Approximate Model of Viscous and Squeeze-film Damping Ratios of Heat Exchanger Tubes Subjected to Two-Phase Cross-Flow (2 상 유동장에 놓인 열 교환기 튜브에 작용하는 점성과 압착막 감쇠비의 어림적 해석 모델)

  • Sim, Woo Gun
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.39 no.1
    • /
    • pp.97-107
    • /
    • 2015
  • An analytical model was developed to estimate the viscous and squeeze-film damping ratios of heat exchanger tubes subjected to a two-phase cross-flow. Damping information is required to analyze the flow-induced vibration problem for heat exchange tubes. In heat exchange tubes, the most important energy dissipation mechanisms are related to the dynamic interaction between structures such as the tube and support and the liquid. The present model was formulated considering the added mass coefficient, based on an approximate model by Sim (1997). An approximate analytical method was developed to estimate the hydrodynamic forces acting on an oscillating inner cylinder with a concentric annulus. The forces, including the damping force, were calculated using two models developed for relatively high and low oscillatory Reynolds numbers, respectively. The equivalent diameters for the tube bundles and tube support, and the penetration depth, are important parameters to calculate the viscous damping force acting on tube bundles and the squeeze-film damping forces on the tube support, respectively. To calculate the void fraction of a two-phase flow, a homogeneous model was used. To verify the present model, the analytical results were compared to the results given by existing theories. It was found that the present model was applicable to estimate the viscous damping ratio and squeeze-film damping ratio.