• Title/Summary/Keyword: 액적크기 분포

Search Result 73, Processing Time 0.022 seconds

Group Ignition of Liquid Fuel Droplets Cloud (액체연료 액적군의 집단 점화)

  • 박용열;김호영
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.16 no.12
    • /
    • pp.2376-2384
    • /
    • 1992
  • A theoretical analysis is carried out to predict the characteristics of transient ignition phenomena for the spherical fuel droplets cloud with non-uniform droplet size and number density distribution. Numerical calculations are performed for various cases depending on the combinations of the major parameters such as ambient temperature and initial distributions of droplet size and number density. The results of present study show that the ignition delay decreases for higher ambient temperature and smaller droplet size. Droplets cloud of hollow type with outer concentrated distribution ignites most rapidly.

액체 로켓용 2중 충돌(F-O-O-F)형 분사기의 미립화 특성에 관한 연구

  • 권기철;조기순;오제하;강신재
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 1999.10a
    • /
    • pp.2-2
    • /
    • 1999
  • 본 연구에서는 액체 로켓용 추진제 분사기로 많이 활용되는 충돌형 분사기중에서 2중 충돌(F-O-O-F)형 분사기에 대한 미립화 특성을 파악하였다. 액적의 크기를 측정하기 위하여 위상/도플러 입자분석기를 사용하였으며, 모의 추진제로 물을 사용하였다. 모의 추진제의 운동량비와 압력 강하량 변화에 따른 2중 충돌(F-O-O-F)형 분사기의 미립화 특성과 크기분포에 대하여 고찰하였다. 분사기 면으로부터 100mm 떨어진 단면에서 산화제/연료의 운동량비가 MR=1.19에서 MR=6.48까지 증가함에 따라 액적크기(SMD)는 감소하였으며, 액적크기(SMD)가 운동량비(MR)에 대하여 SMD= 193.480+15.687MR-5.036M$R^2$+0.415MR$^3$와 같은 관계식에 근사되었다 또한, 연료와 산화제의 압력강하량이 증가할수록 액적크기(SMD)가 감소하였다. 충돌 분무유동장의 액적크기 분포는 Rosin-Rammler 분포함수와 Upper-limit분포함수 모두에 대하여 잘 일치하고 있다. 본 연구의 결과는 액체 로켓용 충돌형 분사기의 초기 설계단계에서 유용하게 사용될 수 있을 것이다.

  • PDF

분사액체와 운용조건이 공기충돌형 인젝터에 의해 형성되는 액적의 분무특성에 미치는 영향

  • Park, Seung-Gyu;Han, Jae-Seob;Kim, Yoo;Kim, Sun-Jin;Park, Jung-Bae
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 1999.04a
    • /
    • pp.8-8
    • /
    • 1999
  • 2-유체 인젝터의 분무연소에 대한 통찰 및 구조에 대한 이해와 연료-공기 혼합과 연소반응의 물리적 이해에 필요한 수치적 모델의 개발 및 검증을 위해서는 2유체 시스템에서 액체 및 기체 각각의 기본적 특성인 액적크기, 액적속도, 액적의 질량플럭스(flux), 가스상의 속도측정 등이 필요하다. 특히, 액체분무에서는 액적의 크기를 예측하는 것이 매우 중요한 과제이며, 액적의 크기에 영향을 주는 인자들로는 노즐의 형태, 분사액체의 물성치(점도, 표면장력, 밀도), 주위기체의 조건(온도, 압력, 응축과 증발현상), 분사압력 등이 있다. 그러나, 실제 분무액적의 크기는 분포를 가지므로 같은 SMD를 가지더라도 그 분포의 정도는 크게 다를 수 있어 결과적으로 분무액적의 크기를 평균값만으로 표현하는 것은 불충분할 뿐만 아니라 그 적용에도 한계를 가지게 된다. 따라서 분무액적의 평균크기와 함께 그 분포의 정도 등을 함께 나타내려는 시도가 많은 과학자들에 의하여 연구되었다.

  • PDF

Analysis on the Relations of Droplet Size Distribution and Optical Depth in Water Curtain (워터커튼에서 액적의 크기 분포와 광학 두께의 상관관계 분석)

  • You, Woo Jun;Ryou, Hong-Sun
    • Fire Science and Engineering
    • /
    • v.30 no.2
    • /
    • pp.62-67
    • /
    • 2016
  • In this study, the optical depth is analyzed with the effects of droplet size distribution of the water curtain nozzle to attenuate the radiative heat transfer. The HELOS/VARIO equipment is used for the measurement of the droplet size distributions. The spray characteristics are quantified by the investigation of Deirmenjian's modified gamma distribution function. The distribution constant of the nozzle can be obtained as ${\alpha}=1$ and ${\gamma}=5.2$. The generalized equation of the optical depth related with the droplet size distribution is introduced. These results will be applicable to the analysis of the design condition of the water curtain nozzle.

An Experimental Study on the Droplet Size Distribution of Sprinkler Spray for Residential Building (주거용 스프링클러 분무의 액적크기 분포에 관한 실험적 연구)

  • Kim, Sung Chan;Kim, Jung Yong
    • Journal of ILASS-Korea
    • /
    • v.20 no.3
    • /
    • pp.175-180
    • /
    • 2015
  • A series of sprinkler discharging tests was conducted to measure the droplet size and its distribution of residential fire sprinkler heads. Droplet sizes in sprinkler spray were measured using a laser diffraction method for the flush, circular and pendent type sprinkler head. In this study, the $D_{v,50}$ of the flush type sprinkler heads were ranged between $530{\sim}1040{\mu}m$ and those of circular and pendent type were $988{\mu}m$ and $916{\mu}m$, respectively. The measured cumulative volume distributions were followed by a combination of the log-normal and Rosin-Rammler distribution which is widely used in the computational fire analysis and the parameters of distribution function were obtained from the best fit line through the measured data.

An Experimental Study on Droplet Size Characteristics of Liquid Jets in Subsonic Crossflow (수직분사제트에서 액적크기특성에 대한 실험적 연구)

  • Kim, Min-Ki;Song, Jin-Kwan;Kim, Jin-Ki;Yoon, Young-Bin
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 2006.11a
    • /
    • pp.59-63
    • /
    • 2006
  • A direct photograph measurement technique was used to determine the spatial distribution of the spray droplet diameter in subsonic crossflow and it also obtain that SMD distribution by using PLLIF technique. The injector internal flow was classified as three modes such as a normal, cavitation, and hydraulic flip. The objectives of this research are getting a droplet distribution and drop size measurement of normal flow and compare with the other flow effects. Although the study showed visually that drop size were spatially dependent of Air-stream velocity, fuel injection velocity, and normalized distance from the injector exit length.(x/d, y/d) There are also difference characteristics between cavitation, hydraulic flip and the normal flow.

  • PDF

Papers : A Study of Numerical Impinging Jet Models for a Like - doublet Injector of Liquid Rockets (논문 : 액체 로켓의 Like - doublet 인젝터의 충돌 제트 수치 모델에 대한 연구)

  • Park,Jong-Hun;Jeong,Gi-Hun;Yun,Yeong-Bin;Kim,Yeong-Han;Lee,Su-Yong
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.30 no.3
    • /
    • pp.64-76
    • /
    • 2002
  • 기존의 이론적 연구와 실험적 연구를 바탕으로 충돌 제트의 수치 모델을 개발하였다. 본 모델은 like-doublet 충돌제트로부터 생성되는 액적의 모든 특성을 액막이 분열되는 시점에서 결정한다. 액적 특성을 결정하기 위해 이론적 연구로부터 얻어진 액막 두께, 액주의 직경, 액적 크기와 실험적 연구로부터 얻어진 액막/액적 속도, 액막 분열 거리, 분열 주파수, 액적 질량 유량 분포를 이용하였다. 액적의 질량 유량 분포는 Laplace 분포로부터 표준 편차를 이용하여 모사하였다. 또한 실험 결과를 이용하여 액막 분열 거리, 분열 주기, 표준 편차에 대한 경험식을 유도하였다. 개발된 모델은 정성적인 분무 패턴뿐만 아니라 정량적인 SMD 및 질량 유량 분포에서 실험 결과와 잘 일치한다.

Droplet size measurement using image processing method (이미지프로세싱 기법을 이용한 액적크기 측정)

  • Lim Byoungjik;Jung Kihoon;Khil Taeock;Yoon Youngbin
    • Journal of the Korean Society of Visualization
    • /
    • v.2 no.1
    • /
    • pp.25-31
    • /
    • 2004
  • Droplet size is one of the most important parameter which controls the performance of the combustion system using liquid fuel or oxidizer. Droplet formation and its size are mainly affected by the injection velocity and ambient gas density. Recently, droplet size measurement was conducted by PDPA or Malvern particle analyzer using laser light. But at this paper image processing method was developed to measure droplet size. And its validation was investigated with reticle.

  • PDF

액체로켓용 충돌형 인젝터의 질량분포 측정을 위한 PLLIF 기법에 대한 연구

  • 정기훈;고현석;이인수;윤영빈
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 2002.04a
    • /
    • pp.1-1
    • /
    • 2002
  • PLLIF(Planar Laser Liquid Induced Fluorescence) 기법은 분무장을 교란시키지 않고 고해상도의 2차원 질량분포를 빠르게 측정할 수 있기 때문에 기존의 기계적인 분무 분포 측정방법의 한계를 극복하였을 뿐만 아니라 접근이 불가능하였던 인젝터 근방의 분무에 대한 중요한 정보를 제공하고 있다. 그러나 레이저 광을 받은 액적에 의한 산란광의 강도가 클 경우에는 인접한 액적들을 형광시킬 수 있고 액적의 형광신호가 액적들을 통과하면서 감쇠되는 이차산란에 의한 오차는 PLLIF 기법의 정량화에 가장 큰 난점으로 인식되고 있다. 특히 이러한 현상은 분무 분포의 밀도가 높고 액적의 크기가 클수록 강하게 나타나는데, 액체로켓에서 일반적으로 사용되고 있는 like-doublet 인젝터는 이러한 분무 특성을 갖는다. 따라서 Mechanical Patternator 및 PDPA(Phase Doppler Particle Analyzer)로부터 측정한 like-doublet 인젝터의 분무 질량 분포 결과와 비교하여 이차산란에 의한 오차를 파악하여 PLLIF 기법의 적용 가능성을 진단하였다.

  • PDF

Size and Rising Velocity of Liquid Drops in Liquid-Liquid Fluidized-Bed Extractors (유동층 액-액 추출기에서 액적의 크기 및 상승속도)

  • Jung, Sung-Hyun;Kim, Jae-Han;Kang, Tae-Gyu;Kang, Yong;Kim, Sang Done
    • Applied Chemistry for Engineering
    • /
    • v.16 no.1
    • /
    • pp.34-38
    • /
    • 2005
  • Characteristics of size, rising velocity and distribution of liquid drops have been investigated in a immiscible liquid-liquid fluidized-bed whose diameter was 0.102 m and 2.5 m in height. Effects of velocities of dispersed (0~0.04 m/s) and continuous (0.02~0.14 m/s) liquid phases and fluidized particle size (1, 2.1, 3 or 6 mm) on the liquid drop properties in the extractor have been determined. The resultant flow behavior of liquid drops became more complicated with increasing the velocity of dispersed or continuous liquid phase. The resultant flow behavior of liquid complicated with increasing the velocity of dispersed or continuous liquid phase. The resultant flow behavior of liquid drops depended strongly upon the drop size and its distribution. The drop size increased with increasing dispersed phase velocity, but decreased with increasing particle size. However, the size of liquid drop exhibited a local maximum with increasing continuous liquid velocity. The size and rising velocity of liquid drops have been well correlated in terms of operating parameters.