• 제목/요약/키워드: 애자일

검색결과 553건 처리시간 0.039초

슬러리의 안정화가 애자의 물리적 특성에 미치는 영향 (Effect of the Physical Property of Insulator on the Slurry Stability)

  • 안용호;최연규;송병기;한병성
    • 한국전기전자재료학회논문지
    • /
    • 제14권12호
    • /
    • pp.979-986
    • /
    • 2001
  • This paper was researched the effect of slurry stability on the mechanical and electrical property of the porcelain insulator with various raw materials such as feldspar, quartz, clay and l7wt% alumina. The slurry was fabricated after ball milling the mixed raw materials. Green compacts were made by the extrusion and were sintered at 1300$\^{C}$ for 60min in the tunnel kiln. All of the specimens were densified 96% of the theoretical density. The 3-point flexural strength($\sigma$$\_$B/) of the specimen stabilized slurry pH 7.8 was 1650 k9/㎠ and the vickers hardness(Hv) and the fracture toughness(K$\_$IC/) were 27.5 GPa and 2.2 MPa$.$m$\^$$\sfrac{1}{2}$/, respectively. The mechanical properties of the specimen stabilized slurry PH 9.3 were 1716 kg/㎠($\sigma$$\_$B/), 27.6 GPa(Hv) and 3.0 MPa$.$m$\^$$\sfrac{1}{2}$/(K$\_$IC/), respectively. The dielectric strength was increased from 8.3kV/mm to 13.2kV/mm as the increase of the slurry pH from 7.8 to 9.3. Therefore the physical properties of the specimen stabilized slurry pH 9.3 were improved.

  • PDF

코로나 방전에 노출된 고분자 애자용 실리콘 고무의 표면열화 (Investigation of Surface Degradation in Silicone Rubber Due to Corona Exposure)

  • 홍주일;허창수;이기택;황선묵;연복희
    • 한국전기전자재료학회논문지
    • /
    • 제17권10호
    • /
    • pp.1068-1078
    • /
    • 2004
  • In this paper we investigated the characteristics of surface degradation in silicone rubber due to corona exposure and recovery mechanism. It was shown that surface free energy was 22.42 mJ/$m^2$ on initial sample but surface free energy was approximately increased to 71.14 mJ/$m^2$ after 45 minutes. However, surface free energy on silicone rubber after corona discharge treatment was completely recovered within a short time due to diffusion of low molecular weight(LMW) silicone fluid. It was shown that corona discharge insured the increase of diffusible LMW chains, which could lead to recover the surface hydrophobicity. 200~370 g/mol distribution of LMW silicone fluid which was extracted by solvent-extraction with gel permeation chromatography (GPC) was contributed to recovery. The surface degradation characteristics on silicone rubbers and the recovery mechanism based on our results were discussed.

환경조건의 변화에 따른 EPDM 애자의 표면 오손정도의 진단기술 (Diagnosis Technique of Surface Contamination Degree for EPDM Insulator according to Variation of Environment Condition)

  • 박재준;최인혁;김정부
    • 한국전기전자재료학회논문지
    • /
    • 제17권10호
    • /
    • pp.1132-1141
    • /
    • 2004
  • The waveforms of the leakage currents for the surface discharge according to the degree of salt contamination and the variation of environmental condition on the EPDM polymer insulators, were shown in this paper. The variation phenomena of fundamental wave, 3rd and 5th harmonic waveforms were also shown from the beginning of the applied voltage and to the flashover voltage. To develop the technique of percentage contamination degree of EPDM polymer insulator according to the variation of environmental condition, the distortion degree of 3rd and 5th harmonic wave to the fundamental wave was utilized through the spectrum analysis for the waveforms of leakage current in the simulation of salt and fog test. The fact that distortion degree % of 3rd and 5th harmonics for fundamental wave is a necessary indicator for the assessment of contamination degree for the polymer insulators, was known.

가열산화중인 콩기름에서의 하이드로퍼로키사이드(hydroperoxide)의 분해기구 (A Mechanism for the Hydroperoxide Decomposition in a Soybean oil during Thermal Oxidation)

  • 신애자;김동훈
    • 한국식품과학회지
    • /
    • 제17권2호
    • /
    • pp.71-74
    • /
    • 1985
  • 식용 콩기름의 가열산화과정 초기에 형성되는 가장 중요한 중간생성체인 하이드로퍼로키사이드(hydroperoxide)의 생성기구대신 분해기구의 한 모델을 설정하였다. $100^{\circ}C,\;120^{\circ}C,\;150^{\circ}C$$180^{\circ}C$에서 120 ml/min의 공기주입하에 가열산화된 콩기름시료의 하이드로퍼로키사이드외 분해속도를 실험을 통하여 측정하고 위의 분해기구에 적용하여 분석, 검토하였다. 이상의 분석결과 하이드로퍼로키사이드 분해반응의 반응속도차수는 1차적이었음을 알 수 있었다. 또한 이상의 분해속도 측청치에서 산출한 하이드로퍼로키사이드의 해리에너지는 15.876 Kcal/g mol이었다.

  • PDF

소아과에 단기 입원한 환아 부모의 간호 요구도 조사 (A Study on the Nursing Needs of Parents with Hospitalized Child)

  • 유경희;김애자
    • 한국간호교육학회지
    • /
    • 제7권2호
    • /
    • pp.323-332
    • /
    • 2001
  • This study was to investigate the level of nursing needs of parents who have hospitalized child. The subjects for this study were 70 parents who have hospitalized child at pediatric ward in S University Hospital, and the period of data collection was from June 5, 2000 to July 15, 2000. The research instruments used in this study was the Nursing Needs Scale and the cronbach's $\alpha$ of this scale was .92. This instrument had four dimensions : physical nursing needs, therapeutic nursing needs, emotional nursing needs and educational nursing needs. In data analysis, SPSSWIN 10.0 program was used for descriptive statistics. The results were as follows. 1) The range of nursing needs scores was from 104 to 156 and the mean score of the nursing needs was 132.64. 2) The mean score of the therapeutic nursing needs dimension was the most with 3.56 compared to emotional nursing needs(3.25), educational nursing needs(3.25), physical nursing needs(3.14). 3) There was a significant difference in nursing needs of parents according to the level of child's physical function(F=3.39, p<.05). 4) There was a significant correlation between nursing needs and child's physical function(r=-.262, p<.05).

  • PDF

자기제 현수애자의 미세구조분석과 유전특성에 관한 연구 (A Study on the Microstructure Analysis and Dielectric Properties of Porcelain Suspension Insulators)

  • 김찬영;김주용;송일근;이병성
    • 대한전기학회논문지:전기물성ㆍ응용부문C
    • /
    • 제48권9호
    • /
    • pp.641-647
    • /
    • 1999
  • The paper provides the results of microstructure analysis and dielectricproperties of porcelain suspension insulators. The evaluation of characteristics was also made as a function of the manufacturers and fabricated years for the experimental specimens which had been used in real distribution lines. Even though the series A contained higher alumina contents than the series B, the densification of series A was lower than that of series B, resulting from much porosity. The microstructure investigation confirmed that series A had much porosity than series B. The series A contained quartz $(SiO_2),\; mullite\; (Al_6Si_2O_{13}),\; corundum(Al_2O_3),\; and cristobalite\; (SiO_2)$ phases. However, the series B had no cristobalite phase which had very high thermal expansion coefficient. Also, the tan$\delta$of series A was more abruptly increased than that of series B as increasing temperature. The elevated temperature may make much expansion of cristobalite crystal than other crystals, resulting in crack and puncture inside cap during the summer days.

  • PDF

고속전차선로 유리애자 현장 적합성 기초연구 (Basic analysis of suitability for Toughened Glass Stem Insulator applied in the high speed catenary system)

  • 전용주;류영태;이기천;이유경
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 2008년도 춘계학술대회 논문집
    • /
    • pp.423-427
    • /
    • 2008
  • The Operation of high speed train in year 2004 bring about a great change in railroad industry. Especially in railroad construction field we have acquired great Know-how. And up to now we are building up operation skills. But the high speed train system are totally imported, so it is necessary to investigate some of the equipment based on our own environment. In case of Toughened Glass Stem Insulator, we don't have any application case in domestic and limited in abroad. So there must be some characteristic estimation. The estimation was made in three different ways. First electrical field cause, Second physical field cause and finally in circumstance cause. In Electrical field cause, amplitude and number of time for abnormal peak voltage data are collected. And in physical field cause, amplitude and trend of vibration in to the insulator are examined. And I circumstance cause, possibility of flying gravel and ice clod are investigated. Through this basic data suitability for Toughened Glass Stem Insulator using in domestic will be accumulated.

  • PDF

직류전기철도에서의 고분자 지지애자 적용에 관한 연구 (The research for the application of polymer support insulator used in DC railway system)

  • 이기승;김윤식;심재석;정호성;이기원;조호령
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 2009년도 춘계학술대회 논문집
    • /
    • pp.371-377
    • /
    • 2009
  • The use of polymer insulator has increased all over the world. As of 2000's KEPCO has used it fully since they introduced it in early 1990's. In Korea it is very widely used by KORAIL which uses AC 25 kV system in the ground electric car line. And It is also used in tunnel electric car line to support AT feeder line. But it has not been used in the section of DC 1500 V. In case of DC 1500 V electric railway system It is has been developed by research institutes by means of R&D projects since 2008. The user cleans porcelain insulators regularly by water because of dusts and pollution. In case of polymer insulators It is very easy to be made dirty by pollution because of the material properties and hard to be cleaned by cleansing. In accordance with these reasons It is worried about deterioration. This paper deals with anticipating problems when we apply it to DC electric railway system and the procedure for testing polymer support insulator.

  • PDF

고전압 애자용 반도성 유약프리트에서의 Magnetite 결정화 (Magnetite Crystallization in Semiconducting Glaze Frit for High Tension Electric Insulators)

  • 이희수;이동인;전병세
    • 한국세라믹학회지
    • /
    • 제20권4호
    • /
    • pp.333-339
    • /
    • 1983
  • Semiconducting glaxe of iron system for the recent use as high Voltage porcelain insulators often showed the tendancy of unstable thermal properties. Thus the development of frit including magnetite was studied to cover the defect. In the experimental process melted and quenched frits were ground pelletized and heat-treated at various temperatures in the range of 800-1 $300^{\circ}C$ for various soaking time within 4 hours and then crystallized specimens were obtained. The speciment were studied with optical and electron microscope DTA x-ray diffractometer and electrometer The results obtained were as follows : 1) The optimum condition for the crystal growth of magnetite in the frite was the heat-treatment of $1300^{\circ}C$ for 3hrs and in this case the range of crystal size was $10-11\mu\textrm{m}$ 2) The activation energy for the crystal growth of magnetite was 21.1 kcal/mole. 3) The heat-treament at $1, 250^{\circ}C$ and $1, 300^{\circ}C$ resulted in the good thermal stability and the range of surface resistivity was $3.5{\times}10^4-4.0{\times}10^7$, /TEX> $\Omega$/$cm^2$ which was adguate to semiconducting frit. 4) The conduction mechanism seems to be due to the electron mobility rather than ion mobility and the activa-tion energy for the conduction was 0.07-0.15eV/mole for the heat-treated specimes in the range of 1, 250-1, 300C

  • PDF

광학렌즈 AR 코팅에 따른 폴리머애자에서의 방전 자외선 강도 비교 (Comparison of Discharge UV Intensity Due to AR Coating of Optic Lens on Polymer Insulator)

  • 김영석;송길목;방선배;김종민;최명일
    • 조명전기설비학회논문지
    • /
    • 제26권4호
    • /
    • pp.35-40
    • /
    • 2012
  • In this study, the ultraviolet (UV) intensity of polymer insulator was measured using the Anti-Reflective (AR) coating lens on the occurrence of corona discharge. The UV intensity was compared before and after the AR coating. Under the 200-260[nm] of UV lens, the reflection rate before AR coating was 7.5~5.5[%] with 85-89[%] of transmission rate. After AR coating, however, the reflection rate decreased to 1.3~1.22[%] with improved transmission (97.4~97.6[%]). Then, the UV intensity by distance was measured in the polymer insulator. According to the measurement, the UV intensity increased 6.5 times at 37.5[%] of Vm/Vbd with 5[m] of distance. As distance increased, the growth rate declined. As high voltage increased, in addition, AR coating was less effective due to the count error caused by the UV sensor pulse signal overlap. Therefore, it appears that it would be more effective to detect corona discharge with 5[m] or less of distance at diagnosis of power facilities by AR coating and UV sensor sensitivity.