• Title/Summary/Keyword: 앙와위

Search Result 32, Processing Time 0.034 seconds

A Survey of Nursing Practice Guidelines for Prevention of Pressure Injury in the Operating Room ([수술실] 욕창예방 간호 실무지침 현황 및 적용실태 조사)

  • Kim, Seung Ok;Shin, Yong Soon
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.19 no.11
    • /
    • pp.635-644
    • /
    • 2018
  • This descriptive study examined the practical nursing guidelines for the prevention of pressure injuries (PI) in operating rooms and their application. Method: Four general hospitals and three specialized hospitals located in Seoul, Incheon, and Gyeonggido province were selected through an online randomization program and nurses at these hospitals who participated in operations and had at least six months work experience were surveyed. Data were collected from January to April 2018 through a survey distributed to 150 nurses, 129 of whom returned the survey (86% recovery rate). The results showed that 43 nurses provided PI prevention care for patients in a lateral position (33.3%), 37 for patients in a supine position (28.7%), and 36 for patients in a prone position (27.9%). Gel was most widely used as the supporting surface material (102 nurses; 79.1%), followed by sponge (62 nurses; 48.1%), and cotton (47 nurses; 36.4%). Skin was often inspected twice, before and after the use of a supporting surface (90nurses; 69.8%), but no designated tool was used to determine the risk of PI developing (76 nurses; 58.9%). Additionally, the patient's position during surgery (83 nurses; 64.3%) and the length of the operation (i.e., more than two hours, in this case) (49 nurses; 38.0%) were determining factors for whether to use a supporting surface. The operating room nurses used the gel, sponge, and cotton as the supporting surfaces for the prevention of PI and confirmed that the cutoff operation time for the use of a supporting surface was more than 2 hours.

Gastro-esophageal Reflux in Asthmatic Patients (기관지 천식환자에서 위식도 역류에 관한 연구)

  • Suh, Jung-Kyung;In, Kwang-Ho;Lee, So-Ra;Lee, Sang-Yeub;Cho, Jae-Youn;Shim, Jae-Jeong;Kang, Kyung-Ho;Yoo, Se-Hwa
    • Tuberculosis and Respiratory Diseases
    • /
    • v.44 no.4
    • /
    • pp.836-843
    • /
    • 1997
  • Background : The prevalence of Gastro-esophageal reflux(GER) in patients with asthma is estimated to be 50~60% and treatment of GER has been shown to improve asthma symptoms in Western. But GER has been known to be less common in Eastern and GER prevalence rates in asthmatics are not available in Korea. Method : We compared the prevalence rate of GER in 42 patients with asthma to that in 20 healthy normal controls and examed the efficacy of new prokinetic drug, cisapride(40mg/day, 8weeks) in patients with GER and asthma. For acid GER to be considered pathological, 24 hour esophageal pH monitoring should reveal values exceeding upper limit of 95 percentile for at least one of 6 parameter of DeMesseter's table. Result : The results showed GER was more common in patients with asthma(11/42, 26.2%) than normal controls(3/20, 15%) and asthmatics group showed a significant longer supine time pH<4(%) and total time pH<4(%), and more reflux episodes as compared with normal control group. After 4 asthmatics with GER were treated with cisapride, their asthma symtom scores, FEV1 and composite scores of pH monitoring were improved. Conclusion : GER is more common in asthmatics than in normal controls in Korea and prepulsid reduces asthma symptoms in patients with GER and asthma.

  • PDF

Evaluation of a Water-based Bolus Device for Radiotherapy to the Extremities in Kaposi's Sarcoma Patients (사지에 발병한 카포시육종의 방사선치료를 위한 물볼루스 기구의 유용성 고찰)

  • Ahn, Seung-Kwon;Kim, Yong-Bae;Lee, Ik-Jae;Song, Tae-Soo;Son, Dong-Min;Jang, Yung-Jae;Cho, Jung-Hee;Kim, Joo-Ho;Kim, Dong-Wook;Cho, Jae-Ho;Suh, Chang-Ok
    • Radiation Oncology Journal
    • /
    • v.26 no.3
    • /
    • pp.189-194
    • /
    • 2008
  • Purpose: We designed a water-based bolus device for radiation therapy in Kaposi's sarcoma. This study evaluated the usefulness of this new device and compared it with the currently used rice-based bolus. Materials and Methods: We fashioned a polystyrene box and cut a hole in order to insert patient's extremities while the patient was in the supine position. We used a vacuum-vinyl based polymer to reduce water leakage. Next, we eliminated air using a vacuum pump and a vacuum valve to reduce the air gap between the water and extremities in the vacuum-vinyl box. We performed CT scans to evaluate the density difference of the fabricated water-based bolus device when the device in which the rice-based bolus was placed directly, the rice-based bolus with polymer-vinyl packed rice, and the water were all put in. We analyzed the density change with the air gap volume using a planning system. In addition, we measured the homogeneity and dose in the low-extremities phantom, attached to six TLD, and wrapped film exposed in parallel-opposite fields with the LINAC under the same conditions as the set-up of the CT-simulator. Results: The density value of the rice-based bolus with the rice put in directly was 14% lower than that of the water-based bolus. Moreover, the value of the other experiments in the rice-based bolus with the polymer-vinyl packed rice showed an 18% reduction in density. The analysis of the EDR2 film revealed that the water-based bolus shows a more homogeneous dose plan, which was superior by $4{\sim}4.4%$ to the rice-base bolus. The mean TLD readings of the rice-based bolus, with the rice put directly into the polystyrene box had a 3.4% higher density value. Moreover, the density value in the case of the rice-based bolus with polymer-vinyl packed rice had a 4.3% higher reading compared to the water-based bolus. Conclusion: Our custom-made water-based bolus device increases the accuracy of the set-up by confirming the treatment field. It also improves the accuracy of the therapy owing to the reduction of the air gap using a vacuum pump and a vacuum valve. This set-up represents a promising alternative device for delivering a homogenous dose to the target volume.

EMG AND CEPHALOMETRIC STUDY ON CHANCES IN UPPER AIRWAY STRUCTURES AND MUSCLE ACTIVITIES ACCORDING TO THE USE OF MANDIBULAR REPOSITIONING APPLIANCE AND BODY POSTURE IN OSA PATIENTS (폐쇄성 수면 무호흡증 환자에 있어서 하악 재위치 장치 장착과 체위에 따른 상기도 구조와 근활성도의 변화에 관한 EMG 및 두부방사선학적 연구)

  • Park, Young-Chel;Pae, Eung-Kwon;Lee, Jeung-Gweon;Lee, Jong-Suk;Kim, Tae-Kwan
    • The korean journal of orthodontics
    • /
    • v.28 no.4 s.69
    • /
    • pp.547-561
    • /
    • 1998
  • Obstructive sleep apnea (OSA) is a disorder characterized by repetitive episode of upper airway collapse during sleep. Recent studies showed that not only the anatomic factors but the physiologic factors of the upper airway also have effcts on the occurrence of apnea and that the genioglossus muscle also plays an important role in the maintenance of the upper airway. A variety of therapies were performed to treat OSA, and among them the use of mandibular repositioning appliances showed reasonable results. But there is still a lack of research on the structural and physiological mechanism upon the use of mandibular repositioning appliances. The author selected 26(male 17, female 9) OSA patients that came to the Yonsei University Dental Hospital, Department of Orthodontics, and 20 normal adults (male 10, female 10) and took cephalometric radiographs of them in a supine position before and after the placement of the mandibular repositioning appliance to see the structural changes of the upper airway and compare the therapeutic effects between the two groups. We also studied the waking genioglossus muscle activity in OSA patients and investigated the difference in the electromyogram of the genioglosssus muscle upon the change in body posture and the use of mandibular repositioning appliance. Following results were obtained. 1. Among the cephalometric measurements of the upper airway structure, the length of the soft palate, maximum thickness of the soft Palate and SPAS, MAS, VAL, H-H1, MP-H showed statistically significant differences between the normal and OSA groups, but the IAS and EAS showed no statistically significant differences between the two groups. 2. In both the normal and OSA groups, as the epiglottis moved forward on wearing the mandibular repositioning appliance, the epiglottis level of the upper airway increased and the maximum thickness of the soft palate changed and the hyoid bone also moved forward, but the IAS in both groups showed various results and the effect of the mandibular repositioning appliance on the structure of the upper airway was different in the two groups. 3. Upon changing the position, the electromyogram of the genioglossus muscle showed a increasing tendency but there was no statistically significant differences, and when the mandibular repositioning appliance were worn there was a statistically significant increase in the electromyogram of the genioglossus muscle in both the upright and supine positions. The mandibular repositioning appliances not only have an effect on the anatomical structure of the upper airway but also on the physiology of the upper airway. There are different responses to the use of mandibular repositioning appliance between the normal and OSA groups therefore it could be considered to have the different physiology of the upper airway between the two groups.

  • PDF

The Sympathetic Skin Responses after Thoracic Sympathicotomy for Patients with Palmar Hyperhidrosis (수장부 다한증환자의 흉부 교감신경절단술후 교감신경 피부반응)

  • 김오곤;홍종면;이석재;홍장수;이광래;김상규
    • Journal of Chest Surgery
    • /
    • v.32 no.6
    • /
    • pp.579-583
    • /
    • 1999
  • Background: Thoracic sympathicotomy has been used safely and successfully to manage palmar hyperhidrosis. The preoperative and postoperative recording of Sympathetic Skin Responses(SSR) was performed for objective evaluation and follow-up of thoracic sympathicotomy in hyperhidrosis patients, and also for ascertaining the clinical usefullness of SSR. Material and Method: The recording of SSR was performed on 15 patients suffering from palmar hyperhidrosis with Medelec Sapphire Plus electromyogragh before and after thoracic sympathicotomy. Eletrical stimuli on the right median nerve was made in patients in supine position and results were recorded on right and left palms with soles at the same time by 4 channels. Skin temperatures were also monitored simultaneously. T2,3 sympathicotomy was performed with VATS in every patients. SSR was done in 2 patients one month later. Result: Clinically, all patients had symptomatic improvement with satisfaction. Postoperative complication was small amount of residual pneumothorax in 5 patients but it was absorbed sponteneously. There was no recurrence during follow-up period and ten patients(66%) complained compensatory hyperhidrosis. After operation, SSR change was shown in every 15 patients. Abolition of SSR on both palms was achieved in 12 patients(80%) and on both soles in 6 patients. In the other 3 patients, the latencies were significantly delayed and the amplitudes were significantly reduced at both palms and soles. In two patients who were examined at one month later after operation, similar results with postoperative SSRs were shown. The skin temperature on preoperative both palm and sole were lower than normal temperature, and those on postoperative both palm and sole were increased. Those had statistical significance(p<0.05), and the temperature on the palm was increased higher that than on the sole. Conclusion: After thoracic sympathicotomy was performed on palmar hyperhidrosis patients, an increment of skin temperatures and SSR changes were achieved at both palms and soles of all patients. Palmar SSRs were completely abolished in 12 patients(80%), and similar results of postoperative SSRs were achieved. The recording of SSR may be useful to easily and objectively assess the completeness of sympathicotomy and the follow-up of recurrence in hyperhidrosis patients.

  • PDF

Usefulness of Prone Position on PET-CT in Breast Cancer (유방암 PET-CT 검사에서 Prone(복와위)자세의 유용성 평가)

  • Park, Hoon-Hee;Kim, Sei-Yung;Kim, Jung-Yul;Park, Min-Soo;Lim, Han-Snag;Jung, Suk;Kang, Chun-Goo;Kim, Jae-Sam;Lee, Chang-Ho;Lee, Yung-Joo
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.12 no.1
    • /
    • pp.44-48
    • /
    • 2008
  • Purpose: In FDG-PET/CT of breast cancer, a sensitivity was 80~96% and a specificity was 75~95% commonly. It was valuable to identify a cancer in early stage been difficult in Mammography. Most of the PET/CT scans have been examined on supine position, so, the image of breast has been acquired by reconstructed whole body scan image. However, using prone position with a compensator, a shape of breast was reassembly shown to be real by gravity. Therefore, the purpose of this study was to evaluate diagnostic value of prone position in FDG PET-CT of breast cancer. Materials and Methods: 30 female patients with doubtful or positive breast cancer were examined. The PET-CT whole body scan was acquired at 60 minutes after $^{18}F$-FDG injection on Supine position. Then, regional breast spot scan was progressed on prone position using a compensator. Each image was evaluated by physicians blinded to patient's data, and statistical analysis did through SUVs measured in PET-CT images. Results: In 27 of 30 patients, prone position was shown accurate discrimination and diagnostic value, but in another 3 patients had a lesion 1cm below, PET-CT couldn't detect it, unlike MRI. Consequently, prone position distinguished a lesion better than Supine position, because of low degree of metamorphosis by gravity. The SUVs analysis of each position was significant (p value=0.004). Conclusion: In PET-CT of breast cancer, prone position could detect micrometastasis as well as primary lesion, better than supine position. Therefore, this study proposes that any technical change considered morphological feature like prone position can offer adequate and useful diagnostic information, together with complementary quantitative analysis.

  • PDF

Treatment Outcome of Mandibular Advancement Device in Obstructive Sleep Apnea Patients- Polysomnographic and Cephalometric analyses (수면무호흡증 환자에서 수면다원검사와 두부규격방사선사진을 이용한 하악전방이동장치의 치료효과에 관한 연구)

  • Chung, Jin-Woo;Kim, Ebee;Kim, Sung-Hun
    • Journal of Oral Medicine and Pain
    • /
    • v.38 no.2
    • /
    • pp.203-213
    • /
    • 2013
  • Objecives : The purpose of the study was to evaluate treatment outcome of mandibular advancement device(MAD) in obstructive sleep apnea (OSA) patients using full night polysomnography and cephalometry. Methods : Twenty-seven OSA patients were confirmed by full night, lab-attended polysomnography. Cephalometric examinations were conducted to obtain SNA, ANB, $AH{\bot}MP$, AH-C3, SPT, PNS-U, NAS, SOAS, MOAS, and HAS. Mandibular advancement devices (MADs) were fabricated and delivered for all subjects. After acclimation period of MAD, the second polysomnographic examinations were conducted in the same manner. Polysomnographic variables were compared between before and after MAD placement. Also, correlation coefficients were calculated between apnea-hypopnea index (AHI) and each item of cephalometric parameters. Results : There were significant improvements in total AHI, lowest $SpO_2$, and total arousal index after MAD therapy. Also, there were significant improvements in NREM $SpO_2$ and NREM AHI, but not in REM $SpO_2$ and REM AHI with MAD. Stratifying the sleep stage, there were significant decrease in stage I and significant increases in stage II and REM, but change in stage III was not significant. SNA and SOAS were significantly correlated with total AHI and NAS was significantly correlated with supine AHI. ANB was significantly associate with the effect of MAD. Conclusions : MAD is an effective treatment in OSA patients comparing polysomnographic variables before and after treatment. Cephalometric examination can be useful to evaluate OSA patients and predict treatment outcome of MAD.

The error analysis of field size variation in pelvis region by using immobilization device (고정기구의 사용이 골반부위 방사선조사영역의 변화에 미치는 오차분석)

  • Kim, Ki-Hwan;Kang, No-Hyun;Bim, Dong-Wuk;Kim, Jun-Sang;Jang, Ji-Young;Kim, Yong-Eun;Kim, Jae-Sung;Cho, Moon-June
    • Journal of Radiation Protection and Research
    • /
    • v.25 no.1
    • /
    • pp.31-36
    • /
    • 2000
  • In radiotherapy, it may happen to radiate surrounding normal tissue because of inconsistent field size by changing patient position during treatment. We are going to analyze errors reduced by using immobilization device with Electonic portal imaging device(EPID) in this study. We had treated the twenty-one patients in pelvic region with 10 MV X-ray from Aug. 1998 to Aug. 1999 at Chungnam National University Hospital. All patients were treated at supine position during treatment. They were separated to two groups, 11 patients without device and 10 patients with immobilization device. We used styrofoam for immobilization device and measured the errors of anterior direction for x, y axis and lateral direction for z, y axis from simulation film to EPID image using matching technique. For no immobilization device group, the mean deviation values of x axis and y axis are 0.19 mm. 0.48 mm, respectively and the standard deviations of systematic deviation are 2.38 mm, 2.19 mm, respectively and of random deviation for x axis and y axis are 1.92 mm. 1.29 mm, respectively. The mean deviation values of z axis and y axis are -3.61 mm. 2.07 mm, respectively and the standard deviations of systematic deviation are 3.20 mm, 2.29 mm, respectively and of random deviation for z axis and y axis are 2.73 mm. 1.62 mm, respectively. For immobilization device group, the mean deviation values of x axis and y axis are 0.71 mm. -1.07 mm, respectively and the standard deviations of systematic deviation are 1.80 mm, 2.26 mm, respectively and of random deviation for x axis and y axis are 1.56 mm. 1.27 mm, respectively. The mean deviation values of z axis and y axis are -1.76 mm. 1.08 mm, respectively and the standard deviations of systematic deviation are 1.87 mm, 2.83 mm, respectively and of random deviation for x axis and y axis are 1.68 mm, 1.65 mm, respectively. Because of reducing random and systematic error using immobilization device, we had obtained good reproducibility of patient setup during treatment so that we recommend the use of immobilization device in pelvic region of radiation treatment.

  • PDF

Usefulness of Non-coplanar Helical Tomotherapy Using Variable Axis Baseplate (Variable Axis Baseplate를 이용한 Non-coplanar 토모테라피의 유용성)

  • Ha, Jin-Sook;Chung, Yoon-Sun;Lee, Ik-Jae;Shin, Dong-Bong;Kim, Jong-Dae;Kim, Sei-Joon;Jeon, Mi-Jin;Cho, Yoon-Jin;Kim, Ki-Kwang;Lee, Seul-Bee
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.23 no.1
    • /
    • pp.31-39
    • /
    • 2011
  • Purpose: Helical Tomotherapy allows only coplanar beam delivery because it does not allow couch rotation. We investigated a method to introduce non-coplanar beam by tilting a patient's head for Tomotherapy. The aim of this study was to compare intrafractional movement during Tomotherapy between coplanar and non-coplanar patient's setup. Materials and Methods: Helical Tomotherapy was used for treating eight patients with intracranial tumor. The subjects were divided into three groups: one group (coplanar) of 2 patients who lay on S-plate with supine position and wore thermoplastic mask for immobilizing the head, second group (non-coplanar) of 3 patients who lay on S-plate with supine position and whose head was tilted with Variable Axis Baseplate and wore thermoplastic mask, and third group (non-coplanar plus mouthpiece) of 3 patients whose head was tilted and wore a mouthpiece immobilization device and thermoplastic mask. The patients were treated with Tomotherapy after treatment planning with Tomotherapy Planning System. Megavoltage computed tomography (MVCT) was performed before and after treatment, and the intrafractional error was measured with lateral(X), longitudinal(Y), vertical(Z) direction movements and vector ($\sqrt{x^2+y^2+z^2}$) value for assessing overall movement. Results: Intrafractional error was compared among three groups by taking the error of MVCT taken after the treatment. As the correction values (X, Y, Z) between MVCT image taken after treatment and CT-simulation image are close to zero, the patient movement is small. When the mean values of movement of each direction for non-coplanar setup were compared with coplanar setup group, X-axis movement was decreased by 13%, but Y-axis and Z-axis movement were increased by 109% and 88%, respectively. Movements of Y-axis and Z-axis with non-coplanar setup were relatively greater than that of X-axis since a tilted head tended to slip down. The mean of X-axis movement of the group who used a mouthpiece was greater by 9.4% than the group who did not use, but the mean of Y-axis movement was lower by at least 64%, and the mean of Z-axis was lower by at least 67%, and the mean of Z-axis was lower by at least 67%, and the vector was lower by at least 59% with the use of a mouthpiece. Among these 8 patients, one patient whose tumor was located on left frontal lobe and left basal ganglia received reduced radiation dose of 38% in right eye, 23% in left eye, 30% in optic chiasm, 27% in brain stem, and 8% in normal brain with non-coplanar method. Conclusion: Tomotherapy only allows coplanar delivery of IMRT treatment. To complement this shortcoming, Tomotherapy can be used with non-coplanar method by artificially tilting the patient's head and using an oral immobilization instrument to minimize the movement of patient, when intracranial tumor locates near critical organs or has to be treated with high dose radiation.

  • PDF

Study the Analysis of Comparison with AROI and MROI Mode in Gated Cardiac Blood Pool Scan (게이트심장혈액풀 스캔에서 자동 관심영역 설정과 수동 관심영역 설정 모드의 비교 분석에 관한 고찰)

  • Kim, Jung-Yul;Kang, Chun-Koo;Kim, Yung-Jae;Park, Hoon-Hee;Kim, Jae-Sam;Lee, Chang-Ho
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.12 no.3
    • /
    • pp.222-228
    • /
    • 2008
  • Purpose: The objectives of this study were to compare the left ventricle ejection fraction (LVEF) from gated cardiac blood pool scan (GCBP) for analysis auto-drawing region of interest mode (AROI) and manual-drawing region of interest mode (MROI), respectively. To evaluation the relationships between values produced by both ROI modes. Materials and Methods: Gated cardiac blood pool scan using in vivo method Tc-99m Red Blood Cell were performed for 33 patients (mean age: $53.2{\pm}13.2\;y$) with objective of chemotherapy using single head gamma camera (ADAC Laboratories, Milpitas, CA). Left ventricular ejection fraction was automatically and manually measured, respectively. Results: There was significant difference statistically between AROI and MROI ($LVEF^{AROI}$: $71.4{\pm}12.4%$ vs. $LVEF^{MROI}$: $65.8{\pm}5.9%$, p=0.003). Intra-observer agreements in AROI was higher than MROI ($\gamma^{AROI}=0.964$, Cronbach's $\alpha^{AROI}=0.986$ vs. $\gamma^{MROI}=0.793$, Cronbach's $\alpha^{MROI}=0.911$), either. Additionally, there was no significant difference statistically at best septal view (${\Delta}LVEF^{BSV}=0.7{\pm}2.3%$, p=0.233), however statistically significant difference was found at badly separated septal view (${\Delta}LVEF=10.9{\pm}11.4%$, p=0.001). Moreover, Intra-observer agreements in best septal view was higher than badly separated septal view ($\gamma^{BSV}=0.939$, Cronbach's $\alpha^{BSV}=0.978$; $\gamma=0.948$, Cronbach's $\alpha=0.981$ at AROI, $\gamma^{BSV}=0.836$, Cronbach's $\alpha^{BSV}=0.936$; $\gamma=0.748$, Cronbach's $\alpha=0.888$ at MROI). Conclusion: When best septal view was acquired, LVEF by AROI and MROI indicated not different. Comparing Intra-observer agreements with AROI and MROI, the AROI tended to show higher. Therefore, it is considered that the AROI than MROI is valuable in reproducibility and objective when ROI analysis by acquire left ventricular of best septal view.

  • PDF