• Title/Summary/Keyword: 앙와위

Search Result 32, Processing Time 0.018 seconds

THE SIZE OF UPPER AIRWAY OF THE SNORER IN UPRIGHT AND SUPINE POSITION (Snorer의 앙와위와 직립위에서의 상기도 크기)

  • Kim, Jong-Chul;Cho, Hong-Kyu;Lee, Gye-Hyeong
    • The korean journal of orthodontics
    • /
    • v.26 no.1 s.54
    • /
    • pp.43-52
    • /
    • 1996
  • The purpose of this study was to compare and evaluate the upper airway structure between the snorers and asymptomatic control subjects depending on the positional change. Lateral cephalograms in the upright and supine position were taken in 25 female snorers and 20 female asymptomatic control subjects. The length and the area of the soft palate, tongue and airway were measured and evaluated statistically. The results obtained were as follows : 1. The snorers showed longer and higher tongue, narrower and longer airway, inferiorly positioned hyoid bone, longer and broader soft palate and narrower hypopharynx than the control subjects both in the upright and supine position. In addition, the snorers showed broader tongue area and narrower oropharynx area than the control subjects in supine position. 2. Depending on the positional change from upright to supine position, the controls and the snorers showed decreased airway length and superior positioned the hyoid bone. In addition, the snorers showed decreased tongue length and height, airway length and thickness and oropharynx area, but increased tongue area and soft palate area.

  • PDF

Retrospective Study on Effect of Chuna Therapy, Also Known as Supine JS Cervical Therapy, Combined with Korean Medicine Treatment on Neck Pain and Headache Caused by Whiplash Injury (편타성 손상에 의한 경항통 및 두통 환자의 추나요법 병행 한방복합치료의 효과: 후향적 관찰연구 - 앙와위 경추 JS 신연 교정기법을 중심으로)

  • Kim, NamHoon;Jeon, Dong-Hwi;Lee, Jung Min;Oh, MinSeok
    • Journal of Korean Medicine Rehabilitation
    • /
    • v.31 no.2
    • /
    • pp.57-67
    • /
    • 2021
  • Objectives To observe the pain reduction effect of Korean medical treatment combined with supine JS cervical therapy on neck pain and headache caused by whiplash injury. Methods The medical records of 30 patients suffering from neck pain and headache caused by traffic accidents from August 1, 2020 to October 30, 2020 were studied. 15 patients receiving supine JS cervical therapy combined with Korean medical treatment were assigned to group A and another 15 patients receiving Korean medical treatment but without Chuna therapy were assigned to group B. The following patient data were analyzed retrospectively - age, sex, and number of admission days, neck pain and headache visual analogue scale (VAS), and neck disability index (NDI). Statistical analysis was conducted using IBM SPSS 25.0. for Windows. A p-value≤0.05 was considered to be statistically significant. Results Both neck pain and headache VAS score in group A and B showed a statistically significant decrease. The changes in neck pain and headache VAS score in group A was statistically significant higher compared to those of group B. NDI in group A showed a statistically significant decrease, but NDI in group B did not decreased statistically significant. Conclusions Korean medicine treatment effectively reduces neck pain and headache. Especially, the pain reduction effect is better in patients receiving Korean medicine treatment combined with supine JS cervical therapy than in those receiving Korean medicine treatment without supine JS cervical therapy.

Use of Respiratory Motion Reduction Device (RRD) in Treatment of Hepatoma (간암의 방사선치료 시 호흡운동 감소장치(respiratory motion reduction device, RRD)의 유용성에 관한 연구)

  • Lee Suk;Seong Jinsil;Kim Yong Bae;Cho Kwang Hwan;Kim Joo Ho;Jang Sae Kyung;Kwon Soo Il;Chu Sung Sil;Suh Chang Ok
    • Radiation Oncology Journal
    • /
    • v.19 no.4
    • /
    • pp.319-326
    • /
    • 2001
  • Purpose : Planning target volume (PTV) for tumors in abdomen or thorax includes enough margin for breathing-related movement of tumor volumes during treatment. Depending on the location of the tumor, the magnitude of PTV margin extends from 10 mm to 30 mm, which increases substantial volume of the irradiated normal tissue hence, resulting in increase of normal tissue complication probability (NTCP). We developed a simple and handy method which can reduce PTV margins in patients with liver tumors, respiratory motion reduction device (RRD). Materials and methods : For 10 liver cancer patients, the data of internal organ motion were obtained by examining the diaphragm motion under fluoroscope. It was tested for both supine and prone position. A RRD was made using MeV-Green and Styrofoam panels and then applied to the patients. By analyzing the diaphragm movement from patients with RRD, the magnitude of PTV margin was determined and dose volume histogram (DVH) was computed using AcQ-Plan, a treatment planning software. Dose to normal tissue between patients with RRD and without RRD was analyzed by comparing the fraction of the normal liver receiving to $50\%$ of the isocenter dose. DVH and NTCP for normal liver and adjacent organs were also evaluated. Results : When patients breathed freely, average movement of diaphragm was $12{\pm}1.9\;mm$ in prone position in contrast to $16{\pm}1.9\;mm$ in supine position. In prone position, difference in diaphragm movement with and without RRD was $3{\pm}0.9\;mm$ and 12 mm, respectively, showing that PTV margins could be reduced to as much as 9 mm. With RRD, volume of the irradiated normal liver reduced up to $22.7\%$ in DVH analysis. Conclusion : Internal organ motion due to breathing can be reduced using RRD, which is simple and easy to use in clinical setting. It can reduce the organ motion-related PTV margin, thereby decrease volume of the irradiated normal tissue.

  • PDF

The Combined Therapy of Inhaled Nitric Oxide and Prone Positioning Has an Additive Effect on Gas Exchange and Oxygen Transport in Patients with Acute Respiratory Distress Syndrome (급성호흡곤란증후군 환자에서 복와위(prone position)와 산화질소흡입(nitric oxide inhalation) 병용 치료의 효과)

  • Koh, Youn-Suck;Lim, Chae-Man;Lee, Ki-Man;Chin, Jae-Yong;Shim, Tae-Sun;Lee, Sang-Do;Kim, Woo-Sung;Kim, Dong-Soon;Kim, Won-Dong
    • Tuberculosis and Respiratory Diseases
    • /
    • v.45 no.6
    • /
    • pp.1223-1235
    • /
    • 1998
  • Background and Objective : Although prone positioning has been reported to improve gas exchange, prone positioning alone does not seem to be sufficient to increase systemic oxygen transport in an acute lung injury. The objective of this study was to investigate whether the combined therapy of low dose nitric oxide (NO) inhalation and prone positioning has an additive effect on the oxygenation and hemodynamics in patients with severe ARDS. Patients and Methods : Twelve patients with ARDS were included. Prone positioning alone, later combined with nitric oxide inhalation (5~10 ppm) from the supine position (baseline) were performed with serial measurement of gas exchange, respiratory mechanics and hemodynamic at sequential time points. The patient was regarded as a responder to prone positioning if an increase in $PaO_2/FiO_2$ of more than 20 mm Hg at 30 min or 120 min intervals after prone positioning was observed compared to that of the baseline. The same criterion was applied during nitric oxide inhalation. Results : Eight patients (66.5%) responded to prone positioning and ten patients (83.3%) including the eight just mentioned responded to the addition of NO inhalation. The $AaDO_2$ level also decreased promptly with the combination of prone positioning and NO inhalation compared to that of prone positioning alone ($191{\pm}109$ mm Hg vs. $256{\pm}137$ mm Hg, P<0.05). Hemodynamic parameters and lung compliance did not change significantly during prone positioning only. Following the addition of NO inhalation to prone positioning, the mean pulmonary artery pressure and pulmonary artery occlusion pressure decreased and cardiac output, stroke volume and oxygen delivery increased (P < 0.05) compared to those of prone 120 min. Conclusion : These findings indicate that NO inhalation would provide additional improvement in oxygenation and oxygen transport to mechanically ventilated patients with ARDS who are in a prone position.

  • PDF

A study for the standardization of dental hygiene terms (치위생 용어 표준화를 위한 방안 연구)

  • Hwang, Ji-Young;Cho, Min-Jeong;Park, Young-Nam;Lim, Soon-Ryun;Hwang, Soo-Jeong;Oh, Sang-Hwan
    • Journal of Korean society of Dental Hygiene
    • /
    • v.10 no.4
    • /
    • pp.627-633
    • /
    • 2010
  • Objectives : The purpose of this study was to compare and analyse periodontal terminology of 16 dental hygiene textbooks including periodontology, dental prophylaxis for the standardization. Methods : 16 kinds of major publications were classified into the following criteria. - the standardization of translation, orthography, classification Results : 1. There are twelve cases, all told, of words with same origin used as different explanation and interpretation. Mucogingival Junction is most translated as '치은점막 경계' with high percentage of 53.8%, while Probe is translated as '치주낭 측정기' with 41.7% and Acquired Pellicle is translated as '획득피막' with 57.1%. In addition, Stippling is interpreted as '점몰' with high percentage of 70%, and Supine Position is interpreted as '수평자세' or '앙와위' with 33.3%. Yet, Pen Grasp is explained differently in all five books, whereas Modified Pen Grasp is explained as '변형 연필 잡기법' with 57.1%. The rest, Palm Thumb Grasp and Adaptation, have different interpretation in books, requiring unified interpretation of terms. 2. There are two cases of loanwords expressed according to orthography. Implant is expressed as '임플란트'(87.5%) and '임프란트'(12.5%). Scaling is expressed as '스켈링'(40.0%) and '스케일링'(60.0%). 3. There are four cases of same terms classified in a different way. Classification of 'Probing시 압력' and '치주인대섬유군' concurs only 50.0% in six books. '치석제거 시술자의 위치' is classified differently in all six books, while '정상치은 열구 깊이' concurred 45.5% in books. Conclusions : In conclusion, related academic majors and writers should provide cohesive explanation and interpretation of terms for unification of terminology in the field of periodontics as well as higher level of understanding and learning opportunities for students. Furthermore, description of all terms should be reviewed and analyzed comprehensively based on existing classification criteria in order to provide best standard explanation.

The Latest Trend of Dynamic MR Defecography for the Chronic Constipation Patient (만성 기능성 변비 환자에서 동적 MR Defecography의 최신동향)

  • Yoon, Seok-Hwan
    • Journal of radiological science and technology
    • /
    • v.27 no.4
    • /
    • pp.17-21
    • /
    • 2004
  • With advancement of the medical imaging technology, the dynamic pelvic MRI (magnetic resonance imaging) has been introduced and used for dynamic MR defecography to improved diagnosis of the patients. At the early stage of its use, it was mostly used to diagnose enterocele or cystocele, then its use was extended to diagnose the organ prolapse and other dysfunctional pelvis organs. There now have been many reports of other diseases such as the functional constipation and others. This paper introduces the pelvis MRI and the dynamic MR defecography and reports the future trend in their clinical applications. Until recently, the studies with pelvic MRI were mostly focused on observing the movement of the pelvis in the supine position. Yang and 26 others reported good result in observing the patients with the pelvic organ prolapse by using the pubococcygeal line as the anatomical index. Using the fast gradient recalled acquisition (fast GRASS), they compared cystocoele, genitourinary prolapse, enterocoele and rectocoele with the control group. Kruyt et al. observed the posterior compartment and reported that MRI was more helpful than the fluoroscopy. Healy et al. applied the dynamic MRI test on the patients with constipation or incontinence as well as the control group without those symptoms. Since then, MRI technology has further advance by Lienemann, who was able to attain the more detailed images using the fast T2 weighted turbo spin echo technology, and others. If its limitation in diagnosing intussusception and the like, since the observation can be made only from the supine position, can be overcome with open MR or others, it is envisages that the method can eventually replace the radiological defecography.

  • PDF

Verification of Target Position in Stereotactic Radiosurgery Based on Photon Knife System (Photon Knife 시스템에 근거한 뇌정위 방사선수술에서 표적위치 확인)

  • 최태진;김진희;김옥배
    • Progress in Medical Physics
    • /
    • v.14 no.2
    • /
    • pp.99-107
    • /
    • 2003
  • This study was performed to prepare the verification film for localizing beam-target position with the Photon Knife radiosurgery system (PKRS) using linear accelerator(Mitsubishi, Model ML-15MDX). We developed a laser calibration system using a reticle of transparent lucite to detect Inlet and outlet beams. We verified fixation of the second collimator with film mounted on a holder in the shape of an octagon block 5cm apart from the isocenter. The film was exposed to photon beams of linear accelerator at an interval of 45 degrees during the gantry movement. There were no shifts in the beam of the second collimator during gantry movement. We used a position marker which is designed a head-shaped small lead block and a 10 mm in diameter of steel bead in the plastic tube. The position marker helped to verify the beam directions with patient position in multi-arc and trans-multi-arc of PKRS The verification of beam alignments showed an average 0.8$\pm$0.26 mm discrepancy in LINAC-gram images of PKRS. In our study, the couch movement was $\pm$5 mm laterally, while it shook $\pm$ 2 mm toward the couch axis. The couch, however, was immediately returned to the initial site after shaking. Thus, we postulate that the beam-target position(s) should be verified with LINAC-gram in a stereotactic radiosurgery system to achieve the accuracy of beam-target alignment.

  • PDF

The Comparison of Sleep Characteristics According to the Sleep Positions in Healthy Newborns (정상 신생아의 체위에 따른 수면양상 및 행동변화 비교)

  • Lee Ae Ran;Ahn Hae Young;Lee Jong Soon
    • Child Health Nursing Research
    • /
    • v.5 no.3
    • /
    • pp.281-291
    • /
    • 1999
  • The purpose of this study was to compare the sleep characteristics between the prone and the supine position in healthy newborns. The 48 newborns were observed in the prone position and the supine position respectively on the 2nd day after birth. The data were collected from January to May, 1999. The state of a newborn was classified and categorized to 6 states (deep sleep. light sleep, drowsy, quiet alert, active alert, crying) by Barnard. The movements of eyes, face and extremities, pulse and arterial oxygen were observed and recorded continuously from the start of sleep after feeding until the time of being woken for the next feeding by a trained nurse The data was analyzed by using paired t-test. The results of this study were as follows; 1. There was no significant difference in the length of sleeping time between the prone and the supine position. 2. There was no significant difference in the length and frequencies of each states(deep sleep, light sleep, drowsy, quiet alert, active alert, crying) between the prone and the supine position But the frequency of light sleep in the supine position was significantly higher than that of the prone position. 3 There was no significant difference In the numbers or eyes movements between the prone and the supine sleep position. But the amount of facial and extremity movement in the supine position was significantly higher than those in the prone position 4. There was no significant difference in the arterial oxygen content between the prone and the supine sleep position. 5. There was no significant difference in the heart rates between the prone and the supine sleep position. The above results indicated that the newborns in the prone Position moved less and slept deeper than those in the supine position. though there was no difference in the length of sleep or arterial oxygen content between the prone and the supine sleep Position. But. Nurses and mothers should consider the relationship between the sleep Position and SIDS suggested by previous researches. The infant's 'awakening' during sleep is a normal process and rather valuable because it can provide an opportunity to promote a stronger relationship between mother and baby. So, It is suggested that the supine sleep position is better than the prone sleep position for infants.

  • PDF

Evaluation of Total Lung Volume and Density using Multi-Detector Computed Tomography in Normal Dogs (정상견에서 다중채널 컴퓨터단층촬영술을 통한 폐용적과 밀도의 평가)

  • Choi, Ho-Jung;Lee, Ki-Ja;Choi, Soo-Young;Lee, Jung-Woo;Han, Woo-Sok;Lee, In;Kwon, Young-Hang;Lee, Young-Won
    • Journal of Veterinary Clinics
    • /
    • v.28 no.5
    • /
    • pp.510-515
    • /
    • 2011
  • This study was performed to quantitatively assess the normal lung volume and density according to the position by multi-detector computed tomography (MDCT) in dogs. Helical CT of the thorax was performed on 4 different positions with dorsal, left lateral, right lateral and ventral recumbency in 6 Pekingese and 6 Maltese dogs. During CT scanning, dogs were kept hyperventilated. Through the 3-dimensional reconstruction of CT images, the lung parameters were measured as the volume and density of the left, right including accessory lobe, and total lung. 3D images represented the different lung shape between Pekingese and Maltese dogs. Their difference of total lung volume and total lung density was not significant on the each position in both breeds. Right lung volume was significantly higher than left. The difference of left and right volume was $66.91{\pm}25.1$ ml. Linear relationship was shown between body weight and lung volume of ventral recumbency position. The dependent lung had higher density and lower volume than nondependent lung in both breed dogs. The volume of nondependent lung was not changed compared with the volume on ventral or dorsal recumbency. The total lung volume measured with MDCT is correlated with the lung density, and the lung density is useful to predict the normal total lung volume.

Rotational Motion of Shoulder in Normal Volunteer and SLAP Lesions (정상 성인과 SLAP 병변이 있는 환자의 견관절 회전운동)

  • Shin, Dong-Eun;Song, Sang-Jun;Park, Hyung-Kun;Kim, Jae-Hyung;Nam, Ki-Shik;Kim, Jae-Hwa
    • Journal of the Korean Arthroscopy Society
    • /
    • v.8 no.2
    • /
    • pp.115-118
    • /
    • 2004
  • Purpose: The purpose of this study is to measure the internal and external rotation of shoulder and compare with normal volunteer and patients diagnosed as SLAP lesion. Materials and Methods: Thirty-eight cases (group 1) who had SLAP lesions at shoulder arthroscopy and fourty young volunteers(group 2) were analyzed retrogradely with medical record, intra-operative arthroscopic photo & video for SLAP lesions and the ROM of shoulder Under the interscalene anesthesia, the range of motion of internal rotation and external rotation were measured on flxed scapula and 90 degree abduction of shoulder, and the same method for group 2. We analyzed the results with two sample T-test and Wisconsin signed ranks test. Results: There was a significant difference between group 1 and group 2 for the ROM of shoulder. (IR; p<0.001,ER; p<0.001).For the group 1, internal and external rotation with the arm abducted 90 averaged 50 and 64 degrees and for the group 2, internal and external rotation averaged 77 and 90 degrees with significant difference(IR; p<0.001,ER; p<0.001).Conclusion: The range of motion of shoulder, especially internal and external rotation significantly decreased in SLAP lesions. Our results suggest that a limited rotational motion of shoulder closely related with SLAP lesion.

  • PDF