• Title/Summary/Keyword: 압하

Search Result 7,242, Processing Time 0.034 seconds

The Study of Affecting Image Quality according to forward Scattering Dose used Additional Filter in Diagnostic Imaging System (부가필터 사용 시 전방 산란선량에 따른 화질 영향에 대한 연구)

  • Choi, Il-Hong;Kim, Kyo-Tae;Heo, Ye-Ji;Park, Hyong-Hu;Kang, Sang-Sik;Noh, Si-Cheol;Park, Ji-Koon
    • Journal of the Korean Society of Radiology
    • /
    • v.10 no.8
    • /
    • pp.597-602
    • /
    • 2016
  • Recent clinical field utilizes the aluminium filter in order to reduce the low-energy photons. However, the usage of the filter can cause adverse effect on the image quality because of the scattered dose that is generated by X-ray hardening phenomenon. Further, usage of filter with improper thickness can be a reason of dose creep phenomenon where unnecessary exposure is generated towards the patient. In this study, the author evaluated the RMS and the RSD analysis in order to have a quantitative evaluation for the effect of forward scattering dose by the filter on the image. as a result of the study, the FSR and the RSD was increased together with the increasing of thickness of the filter. In this study the RSD means the standard deviation of the mean value is relatively size. It can be understood that the signal-to-noise ratio decreases when the average value is taken as a signal and the standard deviation is judged as a noise. The signal-to-noise ratio can understanding as index of resolution at image. Based on these findings, it was quantitatively verified that there is a correlation of the image quality with the FSR by using an additional filter. The results, a 2.5 mmAl which is as recommended by NCRP in the tube voltage of 70 kVp or more showed the 14.6% on the RSD when the filter was not in used. these results are considered able to be utilized as basic data for the study about the filter to improve the quality of the image.

Doses of Coronary Study in 64 Channel Multi-Detector Computed Tomography : Reduced Radiation Dose According to Varity of Examnination Protocols (64 채널 Multi-Detector Computed Tomography를 이용한 관상동맥검사의 선량 : 검사 프로토콜 다변화에 따른 환자선량 감소)

  • Kim, Moon-Chan
    • Journal of radiological science and technology
    • /
    • v.32 no.3
    • /
    • pp.299-306
    • /
    • 2009
  • Purpose : To compare radiation dose for coronary CT angiography (CTA) obtained with 6 examination protocols such as a retrospectively ECG gated helical scan, a prospectively ECG gated sequential scan, low kVp technique, and cardiac dose modulation technique. Materials and Methods : Coronary CTA was performed by using 6 current clinical protocols to evaluate effective dose and organ dose in primary beam area with anthropomorphic female phantom and glass dosimetric system in 64 channel multi-detector CT. After acquiring topograms of frontal and lateral projection with 80 kVp and 10 mA, main coronary scan was done with 0.35 sec tube rotation time, 40 mm collimation ($0.625\;mm{\times}64\;ea$), small scan field of view (32 cm diameter), 105 mm scan length. Heart beat rate of phantom was maintained 60 bpm in ECG gating. In constant mAs technique 120 kVp, 600 mA was used, and 100 kVp for low kVp technique. In a retrospectively ECG gated helical CT technique 0.22 pitch was used, peak mA (600 mA) was adopted in range of $40{\sim}80%$ of R-R interval and 120mA(80% reduction) in others with cardiac dose modulation. And 210 mAs was used without cardiac dose modulation. In a prospectively ECG gated sequential CT technique data were acquired at 75% R-R interval (middle diastolic phase in cardiac cycle), and 120 msec additional padding of the tube-on time was used. For effective dose calculation region specific conversion factor of dose length product in thorax was used, which was recommended by EUR 16262. Results : The mean effective dose for conventional coronary CTA without cardiac dose modulation in a retrospectively ECG gated helical scan was 17.8 mSv, and mean organ dose of heart was 103.8 mGy. With low kVp and cardiac dose modulation the mean effective dose showed 54.5% reduction, and heart dose showed 52.3% reduction, compared with that of conventional coronary CTA. And at the sequential scan(SnapShot pulse mode) under prospective ECG gating the mean effective dose was 4.9 mSv, this represents an 72.5% reduction compared with that of conventional coronary CTA. And heart dose was 33.8 mGy, this represents 67.4% reduction. In the sequential scan technique under prospective ECG gating with low kVp the mean effective dose was 3.0 mSv, this represents an 83.2% reduction compared with that of conventional coronary CTA. And heart dose was 17.7 mGy, this represents an 82.9% reduction. Conclusion : In coronary CTA at retrospectively ECG gated helical scan, cardiac dose modulation technique using low kVp reduced dose to 50% above compared with the conventional helical scan. And the prospectively ECG gated sequential scan offers substantially reduced dose compared with the traditional retrospectively ECG gated helical scan.

  • PDF

Repair of Acute Aortic Arch Dissection with Hypothermic Circulatory Arrest and Retrograde Cerebral Perfusion (저체온순환정지와 역행성 뇌관류에 의한 대동맥궁을 침범한 급성 대동맥 박리증의 수술결과)

  • 이삼윤
    • Journal of Chest Surgery
    • /
    • v.37 no.1
    • /
    • pp.43-49
    • /
    • 2004
  • Background: Acute thoracic aortic dissections involving the aortic arch differ in diagnosis, surgical procedures, and operative results compared to those that do not involve the aortic arch. In general cerebral perfusion under deep hypothermic circulatory arrest (HCA) is performed during the repair of the aortic arch dissection. Here, we report our surgical results of the aortic arch dissection repair using retrograde cerebral perfusion (RCP) and its safety. Material and Method: Between January 1996 and June 2002, 22 consecutive patients with aortic arch dissection underwent aortic arch repair. In 20 of them RCP was performed under HCA. RCP was done through superior vena cava in 19 patients and by systemic retrograde venous perfusion in 1, in whom it was difficult to reach the SVC. When the patient's rectal temperature reached 16 to 18$^{\circ}C$, systemic circulation was arrested, and the amount of RCP amount was 481.1 $\pm$292.9 $m\ell$/min with perfusion pressure of 20∼30 mmHg. Result: There were two in-hospital deaths (4.5%) and one late death (9.1%). Mean circulatory arrest time (RCP time) was 54.0$\pm$ 13.4 minutes (range, 7 to 145 minutes). RCP time has no correlation with the appearance of consciousness, recovery of orientation, or ventilator weaning time (p=0.35, 0.86, and 0.92, respectively). Ventilator weaning was faster in patients with earlier recovery of consciousness and orientation (r=0.850, r=926; p=0.000, respectively). RCP of more than 70 minutes did not affect the appearance of consciousness, recovery of orientation, ventilator weaning time, exercise time, or hospital stay (p=0.42, 0.57, 0.60, 0.83, and 0.51, respectively). Conclusion: Retrograde cerebral perfusion time under hypothermic circulatory arrest during repair of aortic arch dissection may not affect recovery of orientation, ventilator weaning time, neurologic complications, and postoperative recovery.

Comparison of the Low Potassium Dextran Solution and ET-Kyoto Solution in Rabbit Lung (토끼 폐장 분리관류 모형을 이용한 LPD 폐보존액과 ET-Kyoto 폐보존액의 비교)

  • Lim, Cheong;Kim, Kyung-Hwan;Kim, Young-Tae;Sung, Sook-Whan;Kim, Joo-Hyun
    • Journal of Chest Surgery
    • /
    • v.30 no.12
    • /
    • pp.1159-1166
    • /
    • 1997
  • For Improvement of lung preservation, many tripes of preservation solution were developed and tested. The aim of this study was to compare the effect of the most frequently used extracellular type pieservation solution (Low Potassium Dextran, LPD) with a newly developed trehalose containing extracellular type preservation solution(ET-Kyoto, ETK) on postischemic lung function. Twelve New-Zealand white rabbit lungs were harvested and studied on an isolated, blood-perfused model of lung function after 4 hours of cold ischemia at $10^{\circ}C$ In group I (n=6), lungs were preserved with 100 mL/kg of LPD solution; in group II(n=6), lungs were preserved with 100 mL/kg of ETK solution. A few minutes before flushing with preservation solutions, 20$\mu\textrm{g}$ of PGEI were injected into main pulmonary artery. Functions of the preserved lung were compared with PO2, PA pressure, t acheal air pressure, and drylwet ratio. The pulmonary efferent blood oxygen tension at the end of the 60-minute reperfusion period was higher in group II compacted with group I(486.5 $\pm$ 80.3 mmHg versus $432.5\pm82.9$ mmHg at FiO2 1.0, p-value = NS). The mean pulmonary arterial pressure was similar in both $groups.(33.7\pm2.2$ mmHg versus $35.5\pm2.0$ mmHg, p-value : NS). The peak inspiratory airway pressure was significantly lower in group 11(8.010.6 mmHg versus 11.8 $\pm$ 1.4 mmHg, p-value=0.02) The water content of the lung was lower in group II $(70.2\pm6.9%$ versus 78.5 $\pm6.1%),$ but not significant. These data demonstrate that a newly-developed trehalose-containing ET-Kyoto solution yield equal or slightly superior lung function after reperfusion compared with LPD solution.

  • PDF

Development and Validation of an Analytical Method for Ametoctradin Residue Determination in Domestic Agricultural Commodities by HPLC-PDA (HPLC-PDA를 이용한 국내 유통 농산물 중 ametoctradin 잔류량 분석법 개발 및 검증)

  • Do, Jung-Ah;Kwon, Ji-Eun;Lee, Eun-Mi;Kim, Mi-Ra;Kuk, Ju-Hee;Cho, Yoon-Jae;Kang, Il-Hyun;Kim, Hyung-Su;Kwon, Kisung;Oh, Jae-Ho
    • Korean Journal of Food Science and Technology
    • /
    • v.45 no.3
    • /
    • pp.285-292
    • /
    • 2013
  • This study was carried out to validate the safety of ametoctradin residues in agricultural commodities by developing an official analysis method. An analytical method was developed and validated using HPLC-PDA detectors. The samples were extracted with methanol, subsequently partitioned with dichloromethane and purified with florisil column chromatograph using acetone/hexane (30/70, v/v) as solvent. The method was validated by using grape, hulled rice, mandarin, and potato spiked with ametoctradin at 0.05 and 5.0 mg/kg, and pepper at 0.05 and 2.0 mg/kg. Average recoveries were 76-114.8% with relative standard deviation less than 10%, and the limit of detection and limit of quantification were 0.0125 and 0.05 mg/kg, respectively. The result of recoveries and overall coefficient of variation of the laboratory results from Gwangju regional Food and Drug Administration (FDA) and Daejeon regional FDA was accorded with Codex Alimentarius Commission Guideline (CAC/GL 40). Based on these results, this method was found to be appropriate for ametoctradin residue determination and can be used as the official method of analysis.

The Distribution and Diversity of Freshwater Fishes in Korean Peninsula (한반도 담수어류의 분포와 다양성)

  • Yoon, Ju-Duk;Kim, Jeong-Hui;Park, Sang-Hyeon;Jang, Min-Ho
    • Korean Journal of Ecology and Environment
    • /
    • v.51 no.1
    • /
    • pp.71-85
    • /
    • 2018
  • A recent topic of interest within ecology is ecosystem services that are importantly connected with biodiversity. Biodiversity is a fundamental component of ecological studies and has been the subject of many studies worldwide. However, studies on the diversity and distribution of freshwater fish were not undertaken in earnest until 2000, and the number of internationally available studies is therefore still limited. In this study, we used data from "The Survey and Evaluation of Aquatic Ecosystem Health (hereafter SEAEH)" within the framework of which whole water systems on the Korean peninsula are annually monitored to investigate and determine the current status of the diversity and distribution of freshwater fish, as well as to elucidate major factors impacting freshwater fish. A total of 130 species from 28 families were identified at around 953 sites in the SEAEH investigation of 2014. The species Zacco platypus (relative abundance: 28.2%) and Z. koreanus (19.3%) were identified as the most abundant species on the Korean peninsula, and besides these 20 endangered species, 51 endemic species and 4 exotic species were also collected. Highest (96 species) and lowest (72 species) diversity were identified in the Han River Watershed and the Yeongsan/Seomjin River Watershed, respectively. The mean endemic rate was 32.7%, which is higher than the previous rate determined in 1995. The exotic species Micropterus salmoides, Lepomis macrochirus and Carassius cuvieri were found in the whole river system except north Yeongdong, whereas Oreochromis niloticus occurred only at three sites due to the cold water temperatures in winter. Totally, 28 species were found to be translocated to different water systems not connected with known original habitats, most translocations occurring in the Nakdong River and the Yeongdong region. Among the translocated species, Opsariichthys uncirostris amurensis, and Erythroculter erythropterus were dominantly distributed in the mid- to lower reaches of Nakdong River where they may be harmful to the native fish assemblages due to their strong predation. The construction of weirs in connection with the "4 River Project" generated changes in fish assemblages before, during and after the project, resulting in altered habitat condition. Especially, a decrease in the number of endemic species and an increase in the abundance of lentic species were seen. Human-induced global warming will allow exotic species requiring high water temperatures to adapt to the environmental conditions of the Korean peninsula, which may enhance the diversity of native fishes and create changes in distribution. For the establishment of realistic and efficient management and protection strategies for Korean freshwater fish, SEAEH, which produces fundamental and quantitative data for Korean streams, is an important and necessary tool.

Quality Characteristics of Sweet-pumpkin Paste with Different Thermal Condition and Sweet-Pumpkin Latte with Various Gums (가열 조건을 달리한 단호박 페이스트와 검 종류별 단호박 라떼의 품질특성)

  • Park, Bo-ram;Kim, Na-Jung;Yoo, Seon-Mi;Han, Gwi Jung;Kim, Ha Yoon;Han, Hye-min;Shin, Dong-Sun;Shin, Malshick
    • Korean journal of food and cookery science
    • /
    • v.31 no.3
    • /
    • pp.304-317
    • /
    • 2015
  • For the production of pumpkin paste with respect to heating conditions, we steamed the pumpkin for roughly 15 min, heated it with high pressure treatment for 0 min (A), 10 min (B), 20 min (C), 40 min (D), and subsequently investigated the quality characteristics. Generally a significant difference was observed between the pumpkin paste treated with and without high-pressure heat. The values of water content, crude protein and crude fiber of the high-pressure heat-treated groups B, C, D were decreased compared with untreated group A. The soluble fiber in experimental group B sweet-pumpkin paste treated with high-pressure heat for 20 min was higher than the control, and the highest value at 2.02. Experimental group D sweet-pumpkin paste treated with high-pressure heat for 40 min was found to have a decreased soluble fiber content relative to the control. The L value for the color of the group A untreated control sweet-pumpkin paste (no high-pressure heating) decreased as the time increased from 10 min to 40 min, with L values of 50.33, 49.46, and 48.06, respectively. The b value for the color of the sweet-pumpkin paste also decreased, showing a significant difference. Taking into account all the results, we chose experimental group B in order to prepare sweet-pumpkin latte. We used 0.2% gum (xanthan gum, locust bean gum, guar gum) as a stabilizer. Sweet-pumpkin latte with xanthan and locust bean gum has a suspension stability effect that lasts 90 min. The L and b values of sweet-pumpkin latte with gums increase and a value decrease compared with the control. In terms of the overall acceptance of the sweet-pumpkin latte, the experimental group with xanthan gum scored the best.

Evaluation of the Temperature Drop Effect and the Rutting Resistance of Moisture Retaining-Porous Asphalt Pavement Using Accelerated Pavement Testing (포장가속시험을 이용한 보수형 배수성 포장의 온도저감 효과 및 소성변형 저항특성 연구)

  • Kwak, Byoung-Seok;Suh, Young-Chan;Song, Chul-Young;Kim, Ju-Won
    • International Journal of Highway Engineering
    • /
    • v.11 no.3
    • /
    • pp.97-109
    • /
    • 2009
  • One of the main causes of asphalt rutting is high temperature of the pavement. Nevertheless, there has been few research on lowering the pavement temperature for reducing rutting. This study investigated the performance characteristics of moisture-retaining porous asphalt pavement, which is known to have a temperature reducing effect. The purpose of this study is to quantify the temperature reducing effect of moisture-retaining porous asphalt pavement and its effect of reducing rutting through Accelerated Pavement Testing(APT). Additionally, the possibility of reducing the thickness of the pavement in comparison to general dense grade pavement by analyzing structural layer coefficient of moisture retaining pavement. A total of three test sections consisting of two moisture-retaining porous asphalt pavement sections and one general dense-grade porous asphalt pavement section were constructed for this study. Heating and spraying of water were carried out in a regular cycle. The loading condition was 8.2 ton of wheel load, the tire pressure of $7.03kgf/cm^2$, and the contact area of $610cm^2$. The result of this experiment revealed that the temperature reducing effect of the pavement was about $6.6{\sim}7.9^{\circ}C$(average of $7.4^{\circ}C$) for the middle layer and $7.9{\sim}9.8^{\circ}C$(average of $8.8^{\circ}C$) for surface course, resulting in a rutting reduction of 26% at the pavement surface. Additionally, the structural layer coefficient of moisture retaining pavement measured from a laboratory test was 0.173, about 1.2 times that of general dense grade pavement. The general dense-grade porous asphalt pavement test section exhibited rutting at all layers of surface course, middle layer, and base layer, while the test sections of moisture-retaining porous asphalt pavement manifested rutting mostly at surface course only.

  • PDF

Enhanced Bioslurping System for Remediation of Petroleum Contaminated Soils (Enhanced Bioslurping system을 이용한 유류오염 토양의 복원)

  • Kim Dae-Eun;Seo Seung-Won;Kim Min-Kyoung;Kong Sung-Ho
    • Journal of Soil and Groundwater Environment
    • /
    • v.10 no.2
    • /
    • pp.35-43
    • /
    • 2005
  • Bioslurping combines the three remedial approaches of bioventing, vacuum-enhanced free-product recovery, and soil vapor extraction. Bioslurping is less effective in tight (low-permeability) soils. The greatest limitation to air permeability is excessive soil moisture. Optimum soil moisture is very soil-specific. Too much moisture can reduce air permeability of the soil and decrease its oxygen transfer capability. Too little moisture will inhibit microbial activity. So Modified Fenton reaction as chemical treatment which can overcome the weakness of Bioslurping was experimented for simultaneous treatment. Although the diesel removal efficiency of SVE process increased in proportion to applied vacuum pressure, SVE process was difficulty to remediation quickly semi- or non-volatile compounds absorbed soil strongly. And SVE process had variation of efficiency with distance from the extraction well and depth a air flow form of hemisphere centering around the well. Below 0.1 % hydrogen peroxide shows the potential of using hydrogen peroxide as oxygen source but the co-oxidation of chemical and biological treatment was impossible because of the low efficiency of Modified Fenton reaction at 0.1 % (wt) hydrogen peroxide. NTA was more efficiency than EDTA as chelating agent and diesel removal efficiency of Modified Fenton reaction increased in proportion to hydrogen peroxide concentration. Hexadecane as typical aliphatic compound was removed less than Toluene as aromatic compound because of its structural stability in Modified Fenton reaction. What minimum 10% hydrogen peroxide concentration has good remediation efficiency of diesel contaminated groundwater may show the potential use of Modified Fenton reaction after bioslurping treatment.

The Effectiveness of CT and MRI Contrast Agent for SUV in 18F-FDG PET/CT Scanning (18F-FDG PET/CT 검사에서 정량분석에 관한 CT와 MRI 조영제의 효과)

  • Cha, Sangyoung;Cho, Yonggwi;Lee, Yongki;Song, Jongnam;Choi, Namgil
    • Journal of the Korean Society of Radiology
    • /
    • v.10 no.4
    • /
    • pp.255-261
    • /
    • 2016
  • In this study, among various factors having influence on SUV, we intended to compare and analyze the change of SUV using CT(4 type) and MRI(3 type) contrast agents which are commercialized now. We used Discovery 690 PET/CT(GE) and NEMA NU2 - 1994 PET phantom as experimental equipment. We have conducted a study as follows; first, we filled distilled water to phantom about two-thirds and injected radioisotope(18F-FDG 37 MBq), contrast agent. Second, we mixed CT contrast agent with distilled water and MRI contrast agent with that water separately. And then, we stirred the fluid and filled distilled water fully not to make air bubble. In emission scan, we had 15minutes scanning time after 40 minutes mixing contrast agent with distilled water. In transmission scan, we used CT scanning and its measurement conditions were tube voltage 120 kVp, tube current 40 mA, rotation time 0.5 sec, slice thickness 3.27 mm, DFOV 30 cm. Analyzing results, we set up some ROIs in 10th, 15th, 20th, 25th, 30th slice and measured SUVmean, SUVmax. Consequently, all images mixed 3 types of MRI contrast agent with distilled water have high SUVmean as compared with pure FDG image but there was no statistical significance. In SUVmax, they have high score and there was statistical significance. And other 4 images mixed 4 types of CT contrast agent with distilled water have significance in both SUVmean and SUVmax. Attenuation correction in PET/CT has been executed through various methods to make high quality image. But we figured out that using CT and MRI contrast agents before PET/CT scanning could make distortion of image and decrease diagnostic value. In that reason, we have to sort out the priority of examination in hospital not to disturb other examination's results. Through this process, we will be able to give superior medical service to our customers.