• Title/Summary/Keyword: 압력제어 솔레노이드 밸브

Search Result 37, Processing Time 0.03 seconds

Pressure Control of Brake Circuit with Piezoelectric-hydraulic Pump Using Pressurization/Depressurization Characteristics (압전유압펌프가 적용된 브레이크 회로의 가감압 특성을 이용한 압력 제어)

  • Hwang, Yong-Ha;Hwang, Jai-Hyuk;Bae, Jae-Sung;Kwon, Jun-Yong
    • Journal of Aerospace System Engineering
    • /
    • v.11 no.3
    • /
    • pp.8-15
    • /
    • 2017
  • In this paper, an equivalent brake hydraulic circuit with a piezoelectric hydraulic pump was constructed, and load pressure control for better pressurization/depressurization characteristics was conducted. To understand pressurization/depressurization characteristics of the equivalent hydraulic circuit, the relation between the load pressure and the input voltage was revealed experimentally. Experiments were also conducted to observe effect of the solenoid valve on depressurization characteristics. In the pressurization experiment, it was validated that transient response time required to achieve desired load pressure may be reduced through voltage control to change pressurization gradient. By applying the valve on/off time control and voltage control, it was also possible to reduce response time in the depressurization process. Therefore, transient response time may be improved within 10ms for pressurization and within 30 ms for depressurization using the control technique suggested in this study. The load pressure control method proposed in this study is useful for controlling load pressure of a hydraulic brake system with the piezoelectric hydraulic pump.

Development of a Walking-type Solar Panel Cleaning Robot Capable of Driving on Inclined Solar Panel (경사진 패널 위에서 주행이 가능한 보행형 태양광 패널 청소로봇 시스템 개발)

  • Park, Sunggwan;Jang, Woojin;Kim, Dong-Hwan
    • The Journal of the Institute of Internet, Broadcasting and Communication
    • /
    • v.20 no.5
    • /
    • pp.79-88
    • /
    • 2020
  • This paper propose the method to drive a solar panel cleaning robot efficiently on an inclined panel using vacuum pad pressure. In this method, the rubber pads using the vacuum pressure are used to attach robot body to the panel surface. By applying the linkage mechanism to the vacuum pads, it was possible to reduce robot weight and power consumption and to prevent slipping of the robot. In addition, the use of solenoid valves, proximity sensors, and encoders to detect movement of the robot body and the control of the pad pressure dedicate to the driving of the robot on an inclined panel. In order to move the robot forward, the operation sequence of multiple solenoid valves was completed, and the six vacuum pads mounted to both legs were accurately controlled to form vacuum and atmospheric pressure in right order so that the robot could move forward without slipping. At last, it was confirmed through experiments that straight-forward moving and rotational movement could be performed up to 36 degrees of inclination angle of solar panel.

Implemetation of Waterpipe Clean Control System for Dental Clinic Unit-chair (치과용 유니트체어에 적용 가능한 수관 세척 제어시스템 구현)

  • Yun, Hyun-Su;Park, Ji-Hyun;Jeong, Do-Un
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2011.05a
    • /
    • pp.760-761
    • /
    • 2011
  • 본 연구에서는 치과용 유니트체어의 용수공급 시스템 중 수관 내부에 생성되는 바이오필름을 보다 효율적으로 제거하기위하여 공기와 물을 혼합한 버블을 생성하고 가변적인 압력을 인가하여 살균과 세척을 동시에 수행할 수 있는 시스템을 개발하고자 하였다. 이를 위하여 공기와 물의 혼합 세척을 통한 바이오필터 세척 및 전기분해를 이용한 용수 살균 시스템을 구현하였으며, 물과 공기의 흐름제어 및 가변적인 압력 조절 제어시스템을 구현하였다. 그리고 무선으로 제어가 가능한 솔레노이드밸브로 구성된 벨브조립체를 구성하여 세척모드 및 용수공급모드의 선택적 운용이 가능한 시스템을 구현하였다.

  • PDF

Tank Pressure Control of PWM Sol V/V for Thrust Control of Launch Vehicle (발사체 추력제어 안정성을 위한 PWM 솔밸브의 탱크압력제어)

  • Lee, Joong-Youp;Hong, Moon-Geun;Han, Sang-Yeop;Kim, Young-Mog
    • 유체기계공업학회:학술대회논문집
    • /
    • 2006.08a
    • /
    • pp.565-568
    • /
    • 2006
  • This paper achieved dynamic characteristics with test to use solenoid valve for flight model that have present. Designed pressure control virtual system which PWM solenoid valve to use test result. Examination compared solenoid valve dynamic characteristics in atmosphere and cryogenic fluid and presented technique and valuation method that measured upstream and down stream pressure of solenoid valve, as well as, temperature, excitation voltage etc. These test results could confirm solenoid valve response time and maximum using frequency characteristic at use in atmosphere and cryogenic temperature and this derived design variables pressure control system from those bases.

  • PDF

Design and Control of Solenoid for Pressure Valve for Electric Pressure Cooker (전기압력밥솥을 위한 압력밸브용 솔레노이드 설계 및 제어)

  • Kim, Dae-Kyong;Woo, Kyung-Il
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.26 no.7
    • /
    • pp.84-91
    • /
    • 2012
  • In this paper, design by magnetic analysis software and proportional control of solenoid for pressure valve for electric pressure cooker is described. The validation of design was proved by 3D finite element analysis results. Also the efficiency of an air ventilation mechanism was considered when pressure was happened by fluid analysis results. The linear proportional control system by AVR was manufactured and its validation was proved by pressure control of solenoid.

Dynamic Characteristics of Clutch System for an Automatic Transmission (자동변속기 클러치 시스템의 동특성 해석)

  • Kim, Ju Hwan;Kim, Hyun-Soo
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.20 no.1
    • /
    • pp.284-294
    • /
    • 1996
  • In this paper, dynamic characteristics of an AT clutch system were investigated considering the dynamics of check ball and hydraulic control valves. Dynamic model of a pressure control solenoid valve (PCSV) was obtained by Bondgraph and permeance method. Also, the clutch piston and check ball dynamics were modeled by considering the effect of centrifugal force of the oil entrapped in the clutch chamber. In order to validate the dynamic models obtained, plunger displacement of PCSV and pressure response of the clutch supply lines were compared with the available experimental data, which were in good accordance with the numerical results. Using the dynamic model of the clutch system, simulations were performed to investigate the effect of the rotational speed on the response of clutch cylinder pressure, clutch piston and check ball displacement, and oil flow rate into the cylinder and flow rate out of the check valve.

Experimental Characteristics of the Electro-Pneumatic Proportional Modulator (비례 모듈레이터 특성)

  • Yun S.;Choi B.O.;Kim C.Y.;Park P.W.;Lee G.W.
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2005.06a
    • /
    • pp.1784-1787
    • /
    • 2005
  • In this paper, proportional modulator which controls the second pressure of the pneumatic system was studied and proportional operating of modulator was gotten by two digital valves that have a fast dynamic characteristics and were controlled by PWM operating method. In order to more precision pressure control, this modulator consist of not only high speed two digital valves but also pressure sensor, measurement equipment and controller having a microprocessing function. In this study, for the development of the new proportional modulator, various research such as PWM control method, test equipment manufacturing, testing and evaluation were accomplished.

  • PDF

A study on the PWM type High Speed Electromagnet (PWM 방식 고속 전자석에 관한 연구)

  • Song, Chang-Seop;Yang, Hae-Jeong;Song, Sung-Bae
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.11 no.6
    • /
    • pp.127-135
    • /
    • 1994
  • This paper is concerned about a high speed electromagnet of Pressure control solenoid valve. Solenoid valve is controlled by means of Pulse width modulation. The magnetostatic field problem on a solenoid is numerically solved by the 2-D axisymmetric finite element method. And permeance method is adopted for analysing the static and dynamic property of solenoid part theoretically. In addition, in this study, experiments on solenoid part were performed in order to measure the magnetic force and plunger displacement. The numerical results coincided with the experimental results. As a result, the magnetic force has the linear relation with displacement of plunger and the primary factors on the performance of PWM type high speed electromagnet are coil resistance, plunger mass, and the length of air gap between plunger and core.

  • PDF

Study on the Characteristics of Surge Pressure by High Frequency PWM Control in Braking System (제동장치에서 고주파수 PWM 제어에 의한 맥동특성 연구)

  • Kim, Byeong-Woo
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.25 no.3
    • /
    • pp.109-114
    • /
    • 2008
  • The solenoid valve of ABS hydraulic modulator is a two directional on-off valve and is controlled by around 100Hz on-off control. When the on-off valve is switched from open state to closed state, there are braking force deterioration, noise and vibration due to surge pressure in the wheel cylinder. In this study, identifies surge pressure in the braking process of ABS, and investigates the way to reduce the phenomenon. To reduce the surge pressure, PWM(Pulse Width Modulation) control with high frequency of 20kHz was attempted. In conclusion, by using the results of this study for the pressure surge prediction, we could expect enhancement of braking performance in ABS.

A Study on Estimating Characteristics of ABS Using High Frequency PWM Control (고주파수 PWM 제어를 이용한 ABS의 특성 평가에 관한 연구)

  • Kim, Byeong-Woo;Lee, Yong-Joo;Park, Ho
    • Transactions of the Korean Society of Machine Tool Engineers
    • /
    • v.13 no.2
    • /
    • pp.69-74
    • /
    • 2004
  • In general the surge pressure generated in hydraulic systems causes noise, vibration and odd effect to the system. To reduce the surge pressure, high frequency PWM control of 20KHz was attempted. To estimate the braking noise caused by surge, a vehicle equipped with on-board ABS hydraulic modulator has been experimented with respect to the various breaking condition. Thorough this experiments, it was found that breaking noise has been reduced using high frequency PWM control method compare with low frequency method. To evaluate high frequency control m practice, including verification of general functionality, EMI tests was experimented. Its was found that it is necessary to have the solution to electromagnetic interference(EMI) generated by switching elements.