• Title/Summary/Keyword: 압력식

Search Result 1,502, Processing Time 0.031 seconds

Development of $O_2$ Purifier by Pressure Swing Adsorption Process (고순도 산소 생산을 위한 산소 정제 PSA 공정 개발)

  • Lee Chang-Ha;Jee Jeong-Geun;Lee Sang-Jin;Moon Heung-Man;Lee Sang-Hoon
    • Journal of the Korean Institute of Gas
    • /
    • v.8 no.1 s.22
    • /
    • pp.37-47
    • /
    • 2004
  • Pressure swing adsorption (PSA) process using CMS as an oxygen purifier was developed to produce high purity oxygen over $99\%$ with high productivity. The cyclic performances such as purity, recovery, and productivity of PSA process were compared experimentally and theoretically under the non-isothermal condition. A binary ($O_2$/Ar 95:5 vol.$\%$) and two kinds of ternary ($O_2/Ar/N_2$ 95:4:1 and 90:4:6 vol.$\%$) mixtures were used as feed gases. The developed process with the consecutive two blowdown steps produced the oxygen with $99.8\%$ purity and $56\%$ recovery from $95\%$ oxygen containing feed. However, in the feed with $90\%$ oxygen, the $O_2$ Purity was decreased up to $97.3\%$. In addition, because the cyclic performances of the suggested process was significantly affected by the diffusion rate, the non-isothermal model with the the modified LDF model was applied for the process simulation. The concentration-dependent rate parameter of the applied rate model was incorporated with the Langmuir isotherm.

  • PDF

A Study on Estimation of Initial Gas in Place for Coalbed Methane Field Using Production Data at Canada (생산자료를 이용한 캐나다 CBM 원시부존량 평가 연구)

  • Seo, Hyeongjun;Moon, Bryan;Kim, Kihong;Han, Jungmin;Kwon, Sunil
    • Journal of the Korean Institute of Gas
    • /
    • v.22 no.1
    • /
    • pp.64-77
    • /
    • 2018
  • This paper presents the prediction of the original gas in place(OGIP) by using the material balance method and decline curve analysis method with production history and pressure transient test data for four coalbed methane wells in the Horseshoe Canyon field. In this study, the conventional gas equation and the Jensen and Smith(J&S) equation were used to material balance analysis, and the Arps' empirical correlation and Khaled method were applied to decline curve analysis. From the results, the OGIP estimated from the conventional gas and the J&S method was small in difference as under 12%. Also, in case of decline curve analysis, it was found that the Khaled method has appropriated to calculate the OGIP, because the OGIP was estimated as unlimited value by the Arps' equation from the decline exponent of 1 - 3.5. The OGIP difference between conventional gas method and Khaled method was calculated as 8.67% ~ 31.04%, and those between J&S method and Khaled method was 13.67% ~ 26.49%.

A Three-Dimensional Galerkin-FEM Model with Density Variation (밀도 변화를 포함하는 3차원 연직함수 전개모형)

  • 이호진;정경태;소재귀;강관수;정종율
    • Journal of Korean Society of Coastal and Ocean Engineers
    • /
    • v.8 no.2
    • /
    • pp.123-136
    • /
    • 1996
  • A three-dimensional Galerkin-FEM model which can handle the temporal and spatial variation of density is presented. The hydrostatic approximation is used and density effects are included by means of conservation equation of heat and the equation of state. The finite difference grids are used in the horizontal plane and a set of linear-shape functions is used for the vertical expansion. The similarity transform is introduced to solve resultant matrix equations. The proposed model was first applied to the density-driven circulation in an idealized basin in the presence of the heat exchange between the air and the sea. The advection terms in the momentum equation were ignored, while the convection terms were retained in the heat equation. Coefficients of the vertical eddy viscosity and diffusivity were fixed to be constant. Calculation in a non-rotating idealized basin shows that the difference in heat capacity with depth gives rise to the horizontal gradient of temperature. Consequently, there is a steady new in the upper layer in the direction of increasing depth with compensatory counter flow .in the lower layer. With Coriolis force, geostrophic flow was predominant due to the balance between the pressure gradient and the Coriolis force. As a test in region of irregular topography, the model is applied to the Yellow Sea. Although the resultant flow was very complex, the character of the flow Showed to be geostrophic on the whole.

  • PDF

지질시대 및 지구조별 국내대리석 석재자원의 분류와 물성

  • 윤현수;홍세선;박덕원;이병대;김주용
    • Proceedings of the KSEEG Conference
    • /
    • 2002.10a
    • /
    • pp.153-169
    • /
    • 2002
  • 국내 대리석류 석재자원은 지질시대 및 지구조별로 선캠브리아기의 경기육괴와 영남육괴, 시대미상의 옥천대 남서부, 캠브리아-오오도비스기의 옥천대 북동부, 그리고 일부 기타시대의 옥천대 북동부 등으로 분류될 수 있다. 전자는 변성퇴적암류내에 협재된 결정질 석회암, 화강암질 편마암내 포획된 결정질 석회암 등s으로 경기육괴의 포천, 김포, 온수리, 목계와 신림도폭 그리고 영남육괴의 춘양, 현동, 울진, 중평동, 장기리와 장계도폭 등이 해당된다. 시대미상암류는 옥천대 남서부로서 목계, 충주, 괴산, 강경, 남원과 송정도폭, 그리고 캠브리아기는 풍촌석회암으로 임계, 호명, 서벽리도폭 등기 해당된다. 오오도비스기는 정선석회암이 분포하는 석병산, 평창, 정선과 임계도폭, 화천리층이 분포하는 문경도폭, 그리고 황강리도폭 등디 해당한다 기타시대는 시대미상의 각력질 석회암과 상부석탄기의 홍점층군내 협재하는 결정질 석회암으로, 이들은 각각 정선도폭과 석병산도폭에 위치한다. 선캠브리아기, 시대미상, 캠브리아기 및 오오도비스기 대리석류의 물성 중에서 흡수율과 공극율은 선캠브리아기, 오오도비스기, 시대미상과 캠브리아기의 순으로 점차 감소한다. 이들의 공극율은 비중에 대하여 대체로 불규칙하며, 흡수율은 공극율에 대하여 거의가 뚜렷한 정의 상관관계를 이룬다. 압축강도는 공극율에 대하여 다소 불규칙한, 그리고 인장강도에 대하여 정의 상관관계를 이룬다. 그리고 마모경도는 압축강도와 인장강도에 대하여 대체로 뚜렷한 정의 경향을 각각 보인다. 이들 대리석류는 선캠브리아기 중경암-경암, 시대미상 중경암-경암, 캠브리아기 거의가 중경암-경암, 그리고 오오도비스기는 경암에 각각 해당한다.하고 구현 단계의 문제점들과 해결책을 기술한다. 다 솔레노이드방식 감압건조장치로 건조한 표고버섯으로 품위에 대한 유의성 검증결과, 표고버섯의 경우 온도별로는 색택과 복원률, 건조실 내부 압력별로는 수축률, 복원률에서 유의차가 있는 것으로 나타났다. 라. 본 연구에서 구명된 감압건조특성을 기초로 하여 배치식 감압건조기를 설계 제작에 활용하고자 한다.ational banks. Several financial interchange standards which are involved in B2B business of e-procurement, e-placement, e-payment are also investigated.. monocytogenes, E. coli 및 S. enteritidis에 대한 키토산의 최소저해농도는 각각 0.1461 mg/mL, 0.2419 mg/mL, 0.0980 mg/mL 및 0.0490 mg/mL로 측정되었다. 또한 2%(v/v) 초산 자체의 최소저해농도를 측정한 결과, B. cereus, L. mosocytogenes, E. eoli에 대해서는 control과 비교시 유의적인 항균효과는 나타나지 않았다. 반면에 S. enteritidis의 경우는 배양시간 4시간까지는 항균활성을 나타내었지만, 8시간 이후부터는 S. enteritidis의 성장이 control 보다 높아져 배양시간 20시간에서는 control 보다 약 2배 이상 균주의 성장을 촉진시켰다.차에 따른 개별화 학습을 가능하게 할 뿐만 아니라 능동적인 참여를 유도하여 학습효율을 높일 수 있을 것으로 기대된다.향은 패션마케팅의 정의와 적용범위를 축소시킬 수 있는 위험을 내재한

  • PDF

Development and Application of Siphon Breaker Simulation Program (사이펀 차단기 시뮬레이션 프로그램의 개발 및 활용)

  • Lee, Kwon-Yeong;Kim, Wan-Soo
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.17 no.5
    • /
    • pp.346-353
    • /
    • 2016
  • In the design conditions of some research reactors, the siphon phenomenon can cause continuous efflux of water during pipe rupture. A siphon breaker is a safety device that can prevent water efflux effectively. However, the analysis of the siphon breaking is complicated because many variables must be included in the calculation process. For this reason, a simulation program was developed with a user-friendly GUI to analyze the siphon breaking easily. The program was developed by MFC programming using Visual Studio 2012 in Windows 8. After saving the input parameters from a user, the program proceeds with three steps of calculation using fluid mechanics formulas. Bernoulli's equation is used to calculate the velocity, quantity, water level, undershooting, pressure, loss coefficient, and factors related to the two-phase flow. The Chisholm model is used to predict the results from a real-scale experiment. The simulation results are shown in a graph, through which a user can examine the total breaking situation. It is also possible to save all of the resulting data. The program allows a user to easily confirm the status of the siphon breaking and would be helpful in the design of siphon breakers.

The Physical Properties of Port Type Crack Injection Method Using Latex Elastic Storage Tube (라텍스 탄성 저장관을 활용한 포트식 균열주입 공법의 물리적 특성에 관한 연구)

  • Kim, Eun-Young;Sho, Kwang-Ho
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.22 no.2
    • /
    • pp.68-75
    • /
    • 2018
  • In this study, to solve the problems of the conventional crack repair and injection method, high elasticity latex was used as the material of the storage tube to withstand the high pressure in the center part differently from the general port. When the repair solution was injected into the crack part, The TPS method was developed so that the air existing in the TPS can be discharged. In addition, a new infusion port in which a valve blocking the backflow of the remediation solution was installed at the injection port was developed and the physical characteristics of the port were analyzed. As a result of the evaluation, it was found that the filling rate of the remedial solution was improved compared to the existing ordinary injector method, and the cracks were completely filled in the test conditions. Compressive strength and tensile strength after repair showed about 20% decrease after repair in case of using ordinary injector method, while TPS method showed about 2~7% increase after repair. The results of this study showed that the injection port method using the elastic storage tube increased the injection performance and the quality after repair compared to the conventional injector method. The result of this study is expected to be utilized as the basic data for application and commercialization of the result to the practical structure.

Comparative analysis of caisson sections of composite breakwaters evaluated by Level I reliability-based design method (Level I 신뢰성 기반 설계법에 의해 산정된 혼성제 케이슨 단면의 비교 분석)

  • Lee, Cheol-Eung;Park, Dong Heon;Kim, Sang Ug
    • Journal of Korea Water Resources Association
    • /
    • v.51 no.7
    • /
    • pp.543-554
    • /
    • 2018
  • A methodology has been presented for evaluating the partial safety factors on the sliding failure mode of vertical caissons of composite breakwaters and for determining the cross sections of those by Level I reliability-based design method. Especially, a mathematical model has been suggested for the sake of a consistency of code format as well as convenience of application in practical design, for which the uncertainties associated with buoyancy and its own weight can be taken into account straightforwardly. Furthermore, design criteria equation has been derived by considering accurately the effect of uplift pressure, so that the cross sections of caissons can be assessed which must be safe against the sliding failure. It has been found that cross sections estimated from partial safety factors proposed in this paper are in very good agreement with the results of Level II AFDA and Level III MCS under the same target probability of failure. However, partial safety factors of the Technical Standards and Commentaries for Port and Harbour Facilities in Japan and Coastal Engineering Manual in USA tend to estimate much bigger or smaller cross sections in comparison to the present results. Finally, many reliability re-analyses have been performed in order to conform whether the stability level of cross section estimated by Level I reliability-based design method is satisfied with the target probability of failure of partial safety factors or not.

A Study on the Treatment of Wastewater from Ion Removal Process for Purifying Electrocoat Paint in the Bath by Use of Reverse Osmosis (역삼투압을 이용한 전착도료 정제공정폐수처리에 관한 연구)

  • 김진성
    • Membrane Journal
    • /
    • v.8 no.2
    • /
    • pp.77-85
    • /
    • 1998
  • To treat effectively EDIR (electrodeposition ion removal) wastewater in terms of CO$_{Mn}$ 1,500~2,000 ppm generated from aluminum painting process, a RO (reverse osmosis) process was designed and installed to recover and reuse the concentrated solvent sent back to the electrocodeposition tank while the permeate reused as rinse water. A RO system in which three polyamide-spiral wound modules ($102\Phi \times 1,016L$ mm) connnected in series had been running to treat 20 m$^3$ in waste volume in 3 days batch operation at the condition of system recovery of 30 %, applied pressure 11.5 $kg_f/cm^2$ and room temperature. During 42 hours continuous operation leading to 5-fold decrease in waste volume, nearly constant permeation flux of 390 l/m$^2$-hr was maintained and the permeate with average CO$_{Mn}$, 300 ppm was obtained which could be used for washing the remaining paint solution in ion-exchange tower instead of demineralized water. Also COD$_{Mn}$ rejection as a function of running time was observed to be in the range of 78~87 % and the observed solvent rejections for ethyl cellusolve, buthyl cellusolve and n-butanol were 79 %, 87 % and 70 %, respectively.

  • PDF

Air-side Heat Transfer and Pressure Drop of a Fin-and-Tube Heat Exchanger Under Low Temperature Condition (저온 조건에서 핀-관 열교환기의 공기측 열전달 및 압력손실)

  • Kim, Nae-Hyun
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.18 no.4
    • /
    • pp.15-20
    • /
    • 2017
  • Currently, residential air conditioners operate as a heat pump during winter. In this case, the outdoor heat exchanger acts as an evaporator obtaining heat from cold air. On the other hand, it acts as a condenser during summer transferring heat to hot air. The outdoor temperature changes significantly from high to low. Generally, the air-side j and f factors are obtained at a standard outdoor temperature. Therefore, the applicability of the j and f factors under different outdoor conditions needs to be checked. In this study, tests were conducted for a two-row louver finned heat exchanger changing the outdoor temperature to subzero. The effects of the tube-side brine flow rate were also checked. The results showed that air-side j and f factors were essentially constant and independent of the outdoor temperature, suggesting that an extension of j and f factors obtained under standard conditions to a low outdoor temperature is acceptable. All j and f factors agreed within 9% and 3%, respectively. Tests were also conducted by changing the coolant flow rate. Both the j and f factors did not change according to the flow rate, suggesting that the tube-side heat transfer correlation is acceptable.

Effect of Walking Exercise with Blood Flow Restriction on Body Composition, Growth Hormone, and Muscle Damage Markers in Obese Women (혈류를 제한한 걷기운동이 비만여성의 신체조성과 성장호르몬, 근손상지표에 미치는 영향)

  • Lee, Jang-Kyu
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.18 no.4
    • /
    • pp.183-190
    • /
    • 2017
  • Blood flow restriction(BFR) exercise is defined as low and short lengthexercise with pneumatic pressure belts at the top of the limbs. This study was conducted to investigate the effects of walking exercise with BFR on body composition, growth hormone, and muscle damage markers in obese women. Eleven obese women(> BMI 25kg/m2&> body fat 30%) wore pneumatic pressure belts at both femurs and performed walking exercise twice per day, 3days/wk for 4 week (walking 2min; resting 1min). Body weight, BMI and body fat significantly decreased after exercise(p<0.05), while% body fat was slightly decreased after exercise, although this difference was not significant. Growth hormones increased slightly after exercise, although not significantly. Muscle damage markers (CK(p<0.05), LDH(p<0.05) and K+(p<0.01 increased significantly after exercise, but Mb was did not change significantly. These results suggest that 4-weeks ofblood flow restriction exercisecould be used to prevent and treat obesity and related chronic diseases, as well as metabolic syndrome. Moreover, the effects were similar to those observed in response to high intensity resistance programs, despite the short period for which BFR were conducted.