• Title/Summary/Keyword: 안정성한계

Search Result 1,073, Processing Time 0.02 seconds

The Effect of PET/CT Images on SUV with the Correction of CT Image by Using Contrast Media (PET/CT 영상에서 조영제를 이용한 CT 영상의 보정(Correction)에 따른 표준화섭취계수(SUV)의 영향)

  • Ahn, Sha-Ron;Park, Hoon-Hee;Park, Min-Soo;Lee, Seung-Jae;Oh, Shin-Hyun;Lim, Han-Sang;Kim, Jae-Sam;Lee, Chang-Ho
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.13 no.1
    • /
    • pp.77-81
    • /
    • 2009
  • Purpose: The PET of the PET/CT (Positron Emission Tomography/Computed Tomography) quantitatively shows the biological and chemical information of the body, but has limitation of presenting the clear anatomic structure. Thus combining the PET with CT, it is not only possible to offer the higher resolution but also effectively shorten the scanning time and reduce the noises by using CT data in attenuation correction. And because, at the CT scanning, the contrast media makes it easy to determine a exact range of the lesion and distinguish the normal organs, there is a certain increase in the use of it. However, in the case of using the contrast media, it affects semi-quantitative measures of the PET/CT images. In this study, therefore, we will be to establish the reliability of the SUV (Standardized Uptake Value) with CT data correction so that it can help more accurate diagnosis. Materials and Methods: In this experiment, a total of 30 people are targeted - age range: from 27 to 72, average age : 49.6 - and DSTe (General Electric Healthcare, Milwaukee, MI, USA) is used for equipment. $^{18}F$- FDG 370~555 MBq is injected into the subjects depending on their weight and, after about 60 minutes of their stable position, a whole-body scan is taken. The CT scan is set to 140 kV and 210 mA, and the injected amount of the contrast media is 2 cc per 1 kg of the patients' weight. With the raw data from the scan, we obtain a image showing the effect of the contrast media through the attenuation correction by both of the corrected and uncorrected CT data. Then we mark out ROI (Region of Interest) in each area to measure SUV and analyze the difference. Results: According to the analysis, the SUV is decreased in the liver and heart which have more bloodstream than the others, because of the contrast media correction. On the other hand, there is no difference in the lungs. Conclusions: Whereas the CT scan images with the contrast media from the PET/CT increase the contrast of the targeted region for the test so that it can improve efficiency of diagnosis, there occurred an increase of SUV, a semi-quantitative analytical method. In this research, we measure the variation of SUV through the correction of the influence of contrast media and compare the differences. As we revise the SUV which is increasing in the image with attenuation correction by using contrast media, we can expect anatomical images of high-resolution. Furthermore, it is considered that through this trusted semi-quantitative method, it will definitely enhance the diagnostic value.

  • PDF

A Study of Equipment Accuracy and Test Precision in Dual Energy X-ray Absorptiometry (골밀도검사의 올바른 질 관리에 따른 임상적용과 해석 -이중 에너지 방사선 흡수법을 중심으로-)

  • Dong, Kyung-Rae;Kim, Ho-Sung;Jung, Woon-Kwan
    • Journal of radiological science and technology
    • /
    • v.31 no.1
    • /
    • pp.17-23
    • /
    • 2008
  • Purpose : Because there is a difference depending on the environment as for an inspection equipment the important part of bone density scan and the precision/accuracy of a tester, the management of quality must be made systematically. The equipment failure caused by overload effect due to the aged equipment and the increase of a patient was made frequently. Thus, the replacement of equipment and additional purchases of new bonedensity equipment caused a compatibility problem in tracking patients. This study wants to know whether the clinical changes of patient's bonedensity can be accurately and precisely reflected when used it compatiblly like the existing equipment after equipment replacement and expansion. Materials and methods : Two equipments of GE Lunar Prodigy Advance(P1 and P2) and the Phantom HOLOGIC Spine Road(HSP) were used to measure equipment precision. Each device scans 20 times so that precision data was acquired from the phantom(Group 1). The precision of a tester was measured by shooting twice the same patient, every 15 members from each of the target equipment in 120 women(average age 48.78, 20-60 years old)(Group 2). In addition, the measurement of the precision of a tester and the cross-calibration data were made by scanning 20 times in each of the equipment using HSP, based on the data obtained from the management of quality using phantom(ASP) every morning (Group 3). The same patient was shot only once in one equipment alternately to make the measurement of the precision of a tester and the cross-calibration data in 120 women(average age 48.78, 20-60 years old)(Group 4). Results : It is steady equipment according to daily Q.C Data with $0.996\;g/cm^2$, change value(%CV) 0.08. The mean${\pm}$SD and a %CV price are ALP in Group 1(P1 : $1.064{\pm}0.002\;g/cm^2$, $%CV=0.190\;g/cm^2$, P2 : $1.061{\pm}0.003\;g/cm^2$, %CV=0.192). The mean${\pm}$SD and a %CV price are P1 : $1.187{\pm}0.002\;g/cm^2$, $%CV=0.164\;g/cm^2$, P2 : $1.198{\pm}0.002\;g/cm^2$, %CV=0.163 in Group 2. The average error${\pm}$2SD and %CV are P1 - (spine: $0.001{\pm}0.03\;g/cm^2$, %CV=0.94, Femur: $0.001{\pm}0.019\;g/cm^2$, %CV=0.96), P2 - (spine: $0.002{\pm}0.018\;g/cm^2$, %CV=0.55, Femur: $0.001{\pm}0.013\;g/cm^2$, %CV=0.48) in Group 3. The average error${\pm}2SD$, %CV, and r value was spine : $0.006{\pm}0.024\;g/cm^2$, %CV=0.86, r=0.995, Femur: $0{\pm}0.014\;g/cm^2$, %CV=0.54, r=0.998 in Group 4. Conclusion: Both LUNAR ASP CV% and HOLOGIC Spine Phantom are included in the normal range of error of ${\pm}2%$ defined in ISCD. BMD measurement keeps a relatively constant value, so showing excellent repeatability. The Phantom has homogeneous characteristics, but it has limitations to reflect the clinical part including variations in patient's body weight or body fat. As a result, it is believed that quality control using Phantom will be useful to check mis-calibration of the equipment used. A value measured a patient two times with one equipment, and that of double-crossed two equipment are all included within 2SD Value in the Bland - Altman Graph compared results of Group 3 with Group 4. The r value of 0.99 or higher in Linear regression analysis(Regression Analysis) indicated high precision and correlation. Therefore, it revealed that two compatible equipment did not affect in tracking the patients. Regular testing equipment and capabilities of a tester, then appropriate calibration will have to be achieved in order to calculate confidential BMD.

  • PDF

Analysis of Management Status and Optimum Production Scale of Quarrying Firms in Korea -Comparative Analysis of Aggregate and Building-Stone Quarrying Firms- (산지채석업체(山地採石業體)의 경영실태(經營實態) 및 적정규모설정(適正規模設定) -골재용(骨材用) 채석업체(採石業體)와 건축용(建築用) 채석업체(採石業體)의 비교(比較) 분석(分析)-)

  • Joung, Ha Hyeon;Cho, Eung Hyouk
    • Journal of Korean Society of Forest Science
    • /
    • v.80 no.1
    • /
    • pp.72-81
    • /
    • 1991
  • This study was carried out to provide necessary information for improving quarrying industry management in Korea. The results of the study are summarized as follows : 1. In aggregate and building-stone quarrying firms the managers over 40 years of age are 97% and 89.1%, the ones above education level of high school are 90% and 85% and the ones not more than 10 years of quarrying experience are 70% and 52%, respectively. Accordingly it can be pointed out that most of the managers of two types of firms are relatively old, have high educational background, while quarrying experiences of building-stone firm managers are longer than that of aggregate firm managers. 2. Most of the management forms are social corporation(60%) for aggregate quarry firms and private management(76%) for building-stone firms. Average areas of permitted stone-pits of aggregate and building-stone quarries are about 2.86ha and 1.66ha respectively. That is, aggregate quarrying firms are carried on a larger scale than building-stone quarrying firms. 3. The yearly average product of aggregate quarrying firms has increased steadily from $88.961m^3$ in 1985 to $144.028m^3$ in 1988, while, in case of building-stone quarry firms, it has significantly increased from $4.155m^3$ to $19.462m^3$ from 1985 to 1987, but reduced to $13.400m^3$ in 1988. Unstable production activities of building-stone quarrying firms may require continuous government support. 4. Major cost items are equipment rental, depreciation, salaries, repair, maintenance for aggregate quarrying firms, and salaries, depreciation, fuel, tax for building-stone quarrying firms. The yearly average rate of return is about 9.7% for aggregate quarry firms and 2.6% for building-stone quarry firms. It can be pointed out that aggregate quarrying firms is better managed than building-stone quarrying firms. 5. The production elasticity of salary for aggregate quarrying firms is 0.495, that of employees is 0.559, and that of capital service is 0.513. The sum of the elasticities is 1.257>1. Fur building-stone quarrying firms, that of employees is 0.492, that of variable costs is 0.192, and that of capital service is 0.498. The sum of elasticities is 1.172>1, thus denotes the increasing returns to scale for both types quarrying firms. 6. The ratio of marginal value product to opportunity cost of empolyees is 2.54, that of variable costs is 3.62, and that of capital service is 1.45, in aggregate quarrying firms. That of employees is 2.47, that is variable costs was 2.34, and that of capital service is 19.67 in building-stone quarrying firms. Therefore the critical factors for more expansion of management scale in aggregate quarrying firms are variable cost and employees, and are capital service in building-stone quarry ing firms. 7. The break-even points of stone sales are about 0.587 billion won and 0.22 billion won in aggregate and building-stone quarrying firms respectively. The optimum sales Level for profit maximization are about 2.0 billion and 0.5 billion in aggregate and building-stone quarry firms respectively.

  • PDF