• Title/Summary/Keyword: 안전설계 기준 검토

Search Result 357, Processing Time 0.027 seconds

Study on the Impact Factors and the Fundamental Frequency Using Statistics of Dynamic Load Test of Railway Bridges. (철도교의 동적 재하시험 통계자료를 활용한 고유진동수와 충격계수 연구)

  • Jung, Hyun-Jun;Kim, Gyu-Seon;Lee, Sang-Cheol;Ju, Min-Kwan
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2010.05a
    • /
    • pp.61-62
    • /
    • 2010
  • This paper provides an analysis using statistical method on the basis of database (DB) of bridge inspection reports performed by KISTEC from 1995 to 2007. Measured impact factors of total 36 railway bridges were classified by the span length, type of bridges and natural frequency. The fundamental frequency and the impact factors of inspected bridge are compared with formulas specified in both domestic and foreign railway bridge design codes.

  • PDF

Structural Design Requirements and Safety Evaluation Criteria of the Spent Nuclear Fuel Disposal Canister for Deep Geological Deposition (심지층 고준위폐기물 처분용기에 대한 설계요구조건 및 구조안전성 평가기준)

  • Kwon, Young-Joo;Choi, Jong-Won
    • Journal of Nuclear Fuel Cycle and Waste Technology(JNFCWT)
    • /
    • v.5 no.3
    • /
    • pp.229-238
    • /
    • 2007
  • In this paper, structural design requirements and safety evaluation criteria of the spent nuclear fuel disposal canister are studied for deep geological deposition. Since the spent nuclear fuel disposal canister emits high temperature heats and much radiation, its careful treatment is required. For that, a long term(usually 10,000 years) safe repository for the spent nuclear fuel disposal canister should be secured. Usually this repository is expected to locate at a depth of 500m underground. The canister which is designed for the spent nuclear fuel disposal in a deep repository in the crystalline bedrock is a solid structure with cast iron insert, corrosion resistant overpack and lid and bottom, and entails an evenly distributed load of hydrostatic pressure from underground water and high pressure from swelling of bentonite buffer. Hence, the canister must be designed to withstand these high pressure loads. If the canister is not designed for all possible external loads combinations, structural defects such as plastic deformations, cracks, and buckling etc. may occur in the canister during depositing it in the deep repository. Therefore, various structural analyses must be performed to predict these structural problems like plastic deformations, cracks, and buckling. Structural safety evaluation criteria of the canister are studied and defined for the validity of the canister design prior to the structural analysis of the canister. And structural design requirements(variables) which affect the structural safety evaluation criteria should be discussed and defined clearly. Hence this paper presents the structural design requirements(variables) and safety evaluation criteria of the spent nuclear fuel disposal canister.

  • PDF

Safety Evaluation Method of Transmission Tower Subjected to Special Load Case According to Broken Wires (전력선 단선으로 인한 이상시 송전철탑의 안전성 평가방법)

  • Jin, Seok Won;Kim, Jong Min;Park, Jong Sup;Kang, Young Jong
    • Journal of Korean Society of Steel Construction
    • /
    • v.20 no.1
    • /
    • pp.131-149
    • /
    • 2008
  • A transmission tower was designed according to general and special load cases based on KEPCO Design Specifications. The special load case such as unbalanced load a cording to some broken wires has not been considered significantly. Therefore, this paper presents investigations on the stability and safety of main post members subjected to unbalanced load and design wind load. In this study, all cases totally considered. From the finite element analyses using LUSAS program, the stresses on the tower subjected to unbalanced load and design wind load were very high in comparison to the allowable stresses of the steel post member that was used. Some of the post member had higher stresses than the yield stress of the steel member. This paper also shows an example to improve the capacity of the post members using increased cross-section members. Based on the analyses results, when investigating the safety of the transmission tower, one must consider thenew design philosophy including ultimate strength of the member and reliability of the special loading cases.

Safety Regulation of Railway Embankment using Velocity of Failure Probability (파괴확률 변화속도를 이용한 철도 성토사면의 안전관리기준)

  • Kim, Hyun-Ki;Shin, Min-Ho;Lee, Sung-Hyeok;Choi, Chan-Yong
    • Journal of the Korean Society for Railway
    • /
    • v.12 no.6
    • /
    • pp.1037-1042
    • /
    • 2009
  • Safety regulation of railway embankment is restricted by safety factor in dry season or rainy season in Korea. Safety factor which is results from the limit equilibrium analysis is varied by various external conditions. And because it has no reflection point, it is very difficult to manage the safety of trains. Safety regulation such like warning sign, reduce speed and train stop is the best choice to reduce the damage of embankments where it is worried about occurrence of disasters. In this study, additional index is proposed to support present safety standards based on unsaturated soil mechanics and reliability analysis. It is velocity of failure probability. It has an apparent reflection point near present safety regulation. It is possible to modify the regulation for safety management and monitoring system of embankments by using this index.

Evaluation of Domestic and Foreign Design Standards for Soil Nailing Method by Analysis of Slope Restoration Case (비탈면 복구사례 분석을 통한 쏘일네일링 공법의 국내외 설계기준 평가)

  • You, Kwang-Ho;Kim, Tae-Won
    • Journal of the Korean GEO-environmental Society
    • /
    • v.20 no.11
    • /
    • pp.11-22
    • /
    • 2019
  • Limit state design (LSD) and allowable stress design (ASD) are two main types of soil nailing design methodologies. In the LSD method, stability is determined by applying individual coefficients to ground strength, working load and etc. The ASD method calculates the safety factor and compares it with the minimum safety factor to determine the stability. The global design trend of soil nailing system is changing from the ASD method to the LSD method. The design method in Korea still adopts the ASD philosophy while others mostly do the limit state design. In this study, four soil nail design methods, 'FHWA GEC 7' in U.S. (2015), 'Clouterre' in France (1991), 'Soil nailing - best practice guidance' in U.K. (2005), 'Geoguide 7' in Hongkong (2008), and 'Design guide for slope in construction work' in Korea (2016) were applied to the evaluation of the stability and the results were analyzed comparatively in brief. It is revealed that the design method of 'the overall stability of soil nail walls' in Korea is the most conservative and next those by FHWA, Clouterre and CIRIA become more conservative in order. However, the difference of results obtained from FHWA and Clouterre is negligible. Also, this study found out that efforts to improve domestic design criterion are needed.

Hydraulic & Hydrologic Design Criteria for an Emergency Discharge of Reservoir (I) (댐 비상방류 설계기준 선정을 위한 수리수문학적 검토(I))

  • Son, Kwang Ik;Yi, Jaeeung
    • Journal of Korea Water Resources Association
    • /
    • v.48 no.3
    • /
    • pp.149-158
    • /
    • 2015
  • It is well known that emergency outlet works have to be provided for the safety of dams. However, concept of emergency outlet works did not applied for the design of the most dams in Korea. Korean design standard for low-level outlet works does not provide enough design criteria which could be used in design of emergency outlet works. In this research, as-built status and hydraulic design criteria of outlet works, such as drawdown rate or hydraulic pressure due to the impounded water depth, were examined. Another relationship between drawdown rate and the dam slope stability was also examined with SEEP model. It was found that 25% reduction of impounded water depth decreases the pressure forces about 50%. Therefore, outlet works should be designed to drawdown properly at the beginning of the emergency. Seepage analysis of dam bodies showed that most of Korean dams could safely stand for 1m/day drawdown rate. Higher drawdown rate could result high discharge so the drawdown rate must be related with the flood risk of downstream. Finally, multi-stage design was recommended that faster discharge for the initial 25% of water depth in 7-10 days than the rest of it in 1-2 months.

Stability Analysis of Levee by Infiltration Analysis for Watershed (도시하천 유역의 침투해석을 통한 제방의 안정성 평가)

  • Lee, Hoo Sang;Lee, Jea Joon;Heo, Jun Heang
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2016.05a
    • /
    • pp.231-231
    • /
    • 2016
  • 산업혁명 이후 인간사회의 산업화 및 도시화의 가속으로 지구온난화는 기후변화를 야기해 왔으며, 이로 인한 각종 부정적인 영향과 심각성은 날로 커져가고 있는 현실이다. IPCC(Intergoverment Panel on Climate Change)는 기후변화의 주범인 온실가스를 감축할 지라도 기후의 탄성 때문에 앞으로 수세기 이상 계속 진행될 것으로 전망하였으며, 기후변화 영향의 근원적 방지는 불가능하기 때문에 결국 수자원 관리 측면에서도 기후변화에 적응하기 위한 각종 적응전략 개발의 필요성을 강조하였다(IPCC, 2007). 또한, 극한강수의 발현비율이 도시 및 비도시 지역의 구분 없이 과거 30년에 비해 크게 증가하고 있으며 이러한 추세는 수공구조물의 치수안전도 저하에 큰 영향을 준다. 우리나라는 그동안 하천, 유역 홍수저감 시설물과 댐 등 대형 수공구조물에 대한 안전성 평가를 주기적으로 수행해 왔으나 단순히 모니터링을 통하여 현재의 안전기준의 부합 여부만을 판단하는 수준에 그치고 있다. 장래 증가하는 홍수피해에 대처하기 위해서는 다양한 극한강우 및 극한홍수시나리오를 기반으로 시설물 설계기준별 홍수 위험도와 취약성을 평가하고, 극한홍수 방어기준을 재설정하여 현재 설계기준을 제고할 필요가 있으며, 시설물별 안전도 평가와 위험도 저감계획 및 경제성 평가를 종합적으로 고려한 실행프레임워크 개발이 시급한 실정이다. 따라서 본 연구에서는 SEEP/W 모형을 이용하여 일반적인 하천 제방을 바탕으로 침투해석을 실시하여 그 결과를 이용하여 안정성 평가에 대하여 검토하였다. 또한 기후변화에 따른 도시하천의 수문특성 변화분석 결과를 바탕으로 향후 발생할 수 있는 극치 수문사상의 값을 반영한 설계기준 강화 수방시설 계획 등의 연구에 활용하며, 여러 가지 수문학적 불확실성에 의하여 가변 가능한 도시하천 유역의 취약성 평가 및 위험도 분석을 통한 기후변화 대응과 수공구조물 설계 및 수방전략 수립에 활용하고자 한다.

  • PDF

Analytical Verification of Seismic Reinforcement Effect of Port Breakwater during Earthquake (지진시 항만 방파제의 내진보강 성능에 관한 해석적 검증)

  • Yihyuk Kwon;Hyeok Seo;Daehyeon Kim
    • The Journal of Engineering Geology
    • /
    • v.33 no.4
    • /
    • pp.657-671
    • /
    • 2023
  • As large-scale earthquakes have occurred in Korea and their aftermath continues to be felt, laws and regulations on seismic design have been emphasized, and in Korea, the seismic design standards have been newly revised after the Gyeongju earthquake. In the revised seismic design standards, a stability review for the destruction of the support activity of the breakwater was newly added. Therefore, in this study, we conducted a stability analysis on the seismic reinforcement method for the study site, and checked the ground acceleration of the subgrade and the displacement of the structure over time. As a result of the stability analysis, the safety factor increased by at least 0.5 and up to 1.7. As a result of the time history analysis, the displacement of the superstructure decreased by up to 290 mm and down to 12 mm in both the shallow and deep sections before and after reinforcement, and the ground acceleration decreased by up to 5.33 m/s and down to 0.31 m/s after reinforcement.

Evaluation for Lateral Movements of Bridge Abutment on Soft Ground (연약지반상 교대측방이동에 대한 판정)

  • 홍원표;송영석;조용량
    • Journal of the Korean Geotechnical Society
    • /
    • v.17 no.4
    • /
    • pp.269-278
    • /
    • 2001
  • 국내 30개의 교대측방이동 사례현장에 대하여 교대기초말뚝의 사면안정효과와 교대의 실측측방변위를 고려한 사면안정해석을 실시하였다. 해석결과 사면안전율은 말뚝의 효과를 무시한 경우 1.5이상, 말뚤의 효과를 고려한 경우 1.8이상 되어야 안전함을 알 수 있다. 그리고, 교대의 실측측방변위와 사면안전율과의 상관관계로부터 교대의 허용측방변위 설계기준은 5cm보다 1.5cm로 함이 더 합리적임을 알 수 있다. 사면안정해석결과와 교대의 실측측방변위를 토대로 기존에 제안된 교대측방이동 판정기준의 국내 적용여부를 검토한다. 이를 위하여 교대의 사면안정해석결과 및 실측측방변위와 교대측방이동 관련지수와의 상관관계를 조사한다. 그 결과 실측된 교대의 측방변위와 이를 고려한 사면안전율은 교대의 측방유동지수, 측방이동판정지수 및 지반의 안정계수와 무관한 경우도 많이 존재하는 것으로 나타났다. 이는 결국 이들 경험적인 지수만으로 교대측방이동을 판정하는 것은 불충분함을 의미한다. 따라서, 교대측방이동을 판정할 경우에는 반드시 교대의 측방변위를 고려한 사면안정해석이 실시되어야 한다.

  • PDF

A Study on the Stability of Slopes Reinforced with Panel-Type Retaining Walls (대절토부 사면의 패널식 옹벽보강에 따른 안정성 검토)

  • Dong-wook Choi;Jun-o Park;Daehyeon Kim
    • Journal of the Korean Geosynthetics Society
    • /
    • v.23 no.2
    • /
    • pp.1-7
    • /
    • 2024
  • Various innovative technologies and methods are being applied to ensure the stability of steep rock slopes. However, there are design limitations concerning site ground conditions, leading to discrepancies between the designed and actual ground conditions during construction. In the case of the retaining wall in Yeosu, where the study area is located, although the construction of a 5-stage retaining wall is planned, at the current completion of the second stage, cracks on the upper part of the wall, settlement in the front of the wall, and seepage have been observed. After the completion of stages one and two, issues regarding cracks and settlement on the upper part of the wall and seepage in the front of the wall were discovered. Thus, there was a need to reevaluate the results of the existing stability assessment. It was confirmed that the issue was due to groundwater leakage, attributed to the lack of clear assessment of the colluvial soil layer during the initial design stage. Therefore, to conservatively reflect groundwater level conditions, a groundwater level contour was positioned at the top of the wall to conduct a slope stability assessment. The assessment results indicated that the safety factor during the rainy season exceeded the required value of 1.3, with a calculated safety factor of 1.31. However, during seismic events, the safety factor was determined to be 1.12, falling short of the required safety factor of 1.3. Therefore, it is suggested that the existing retaining walls constructed during stages one and two undergo reinforcement using methods such as micro-piles with grouting, and additional work should be carried out to ensure a clear assessment of the colluvial soil layer.