• Title/Summary/Keyword: 안전계획

Search Result 2,364, Processing Time 0.028 seconds

A study on rationalized values of deoxygenation coefficient for stream quality modelling in the Hwangguji stream (수질모의시 적정 탈산소계수 선정을 위한 연구 - 황구지천을 대상으로 -)

  • Noh, Huiseong;Ahn, Taejin
    • Journal of Wetlands Research
    • /
    • v.21 no.1
    • /
    • pp.77-83
    • /
    • 2019
  • Stream water qualities have been predicted in the year 2002 and 2014 through providing the Hwangguji Stream Rectification Plan. However, the reliability of result for predicted water quality was relatively lower by applying conventional values of the parameters in model. In this study deoxygenation coefficients between Sema bridge(HGJ2) and Sujik bridge(HGJ3) have been evaluated based on the observed data of water quality and travelling time to compare with the applied value of coefficients in predicting water quality model. The values of deoxygenation coefficient $0.078day^{-1}{\sim}0.748day^{-1}$ for normal period and $0.053day^{-1}{\sim}0.505day^{-1}$ for drought period have been calculated based of observed data between Sema bridge and Sujik bridge. The values of coefficients $0.02day^{-1}{\sim}3.4day^{-1}$ have been applied in predicting water quality model in the year 2002 and $0.043day^{-1}$ 2014. Thus, the simulated results of stream water quality were better than the observed data in 2002, and worse in 2014. It has shown that values of deoxygenation coefficient should be properly estimated based on observed data to predict proper stream water quality by model.

A study on the development and applicability of fire risk assessment method for small road tunnels passing only small cars (소형차 전용 도로터널의 화재 위험도 평가기법개발 및 적용성에 관한 연구)

  • Ryu, Ji-Oh;Choi, Pan-Gyu
    • Journal of Korean Tunnelling and Underground Space Association
    • /
    • v.20 no.6
    • /
    • pp.917-930
    • /
    • 2018
  • A quantitative risk assessment method for quantitatively evaluating the fire risk in designing a road tunnel disaster prevention facilities has been introduced to evaluate the appropriateness of a disaster prevention facility in a large tunnel through which all vehicle types pass. However, since the quantitative risk assessment method of the developed can be applied only to the large sectional area tunnels (large tunnels), it is necessary to develop a quantitative risk assessment method for road tunnels passing only small cars which has recently been constructed or planned. In this study, fire accidents scenarios and quantitative risk assesment method for small road tunnels through small cars only which is based on the methods for existing road tunnels (large tunnels). And the risk according to the distance between cross passage is evaluated. As a result, in order to satisfy the societal risk assessment criteria, the distance of the appropriate distance between cross passages was estimated to be 200 m, and the effect of the ventilation system of the large port exhaust ventilation system was quantitatively analyzed by comparing the longitudinal ventilation system.

The Effects of Supplementary Education Awareness on Interpersonal Communication for Health Care Providers (종합병원 의료인의 교육훈련 인식이 의료인 상호간 커뮤니케이션에 미치는 영향)

  • Jung, Sang-Jin
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.19 no.11
    • /
    • pp.411-420
    • /
    • 2018
  • This study was conducted to identify the effects of interpersonal communication between health care providers after receiving supplementary education. The participants of this study were 433 health care providers who work at 29 general hospitals in Gwangju Metropolitan City and Jeollanamdo Province. Data were collected from June 8 to June 25, 2018 and evaluated by t-tests, dispersion analysis, correlation analysis and stepwise regression. The results were produced by investigating interpersonal communications according to socio-demographic and health-related characteristics including age, education level, bed size of the hospital at which the participant worked, job satisfaction, hospital location, personal health status, experience with health care management and experience with depression. There were significant differences in communication observed according to supplemental education awareness regarding age, bed size of hospital, occupation, wage, type of medical institution of employment, job satisfaction, work location, health status, health care education experience and chronic disease. There were positive correlations between supplemental education awareness in health workers and their interpersonal communication. The factors that had positive effects on interpersonal communication were level of education and health-related education experience, while age, hospital bed size and job dissatisfaction had negative effects. Finally, support environment, learning transfer and results were identified as sub-factors of supplemental education. Based on the results above, it was proposed that educational training to enhance results, provide a supportive environment and foster learning transfer be developed to increase communication between health workers and provide a safe health service for patients.

A Study on the Optimal Location Estimation of Highway Shelter Considering the Driving Duration of Individual Vehicles (개별차량의 운전지속시간을 고려한 고속도로 휴게시설의 적정위치 선정방법 연구)

  • Cho, Hwang young;Lee, Sang jo
    • The Journal of The Korea Institute of Intelligent Transport Systems
    • /
    • v.18 no.4
    • /
    • pp.16-30
    • /
    • 2019
  • In this study, we calculated the driving duration of individual vehicles according to the availability of rest facility on highway, and suggested indicators indicating the potential risk of accidents caused by long-term driving with weights based on the number of vehicles by driving duration of individual links. Based on this, the methodology for estimating the appropriate location of the highway rest facility considering the driving duration of individual vehicles was presented. Using the DSRC individual vehicle data collected from the highways, the appropriate location of the rest facility was calculated by considering the driving duration by classifying weekdays and weekends for the Gyeongbu Expressway. The results showed that the weekly and weekend high risk indicators were different. In the case of weekdays, the risk indicators of Gimchun JC to Kumho JC for Busan were high, while for weekends, the risk indicators of Ansung JC to Dongtan JC for Seoul and Ansung IC to Bukchunan IC for Busan were high. This study has great significance in that it provides a framework for detailed analysis of link units by using non-aggregated data of individual vehicle units. In addition, it is significant that the reasonable driving duration reflecting the behavior of individual vehicles was calculated by analyzing the use of rest facilities.

A Study of Maintenance Method by Monitoring and Evaluation of Water Friendly Facilitiesin Urban Streams - A Case Study of Jeonjucheon in Jeonju-si - (하천친수시설의 모니터링과 평가를 통한 유지관리방안 연구 - 전주천을 중심으로 -)

  • Lim, Hyunjeong;Jeong, Moonsun
    • Journal of Environmental Impact Assessment
    • /
    • v.28 no.3
    • /
    • pp.263-274
    • /
    • 2019
  • The purpose of this study is to examine a monitoring method, management zones, and maintenance strategies for water friendly facilities in urban streams after the completion of ecological restoration projects. Maintenance monitoring items are composed of 'use space& facilities', 'trails& bike roads', 'access', and 'boards'. The evaluation standards of water friendly facilities are 'maintenance conditions', 'safety', and 'usage level' which are rated as 'good', 'moderate', and 'poor'. Through a field survey and evaluation of 15 stream sections in Jeonjucheon,the management levels of each water friendly facility are determined as 'priority maintenance', 'general maintenance', 'maintain/remove', and 'remove'. Based on the evaluation results, management zones and maintenance strategies are proposed for each stream section. As a results, the stream sections of J2, J3, J4, and J9 which have 5 to 9 facilities with 'priority maintenance' are determined as 'intensive management zone'. The stream sections of J5, J6, J7, J8, J11, and J14 which have 1 to 3 facilities with 'priority maintenance' are determined as 'regular management zone'. The stream sections of J1, J10, J12, J13, and J15 which have no facilities with 'priority maintenance' are determined as 'minimum management zone'. The process of monitoring & evaluation system and determining management zones can be applied to establish a systematic maintenance plan for water friendly facilities by participation of governance in the future.

Cellular Automata Simulation System for Emergency Response to the Dispersion of Accidental Chemical Releases (사고로 인한 유해화학물질 누출확산의 대응을 위한 Cellular Automata기반의 시뮬레이션 시스템)

  • Shin, Insup Paul;Kim, Chang Won;Kwak, Dongho;Yoon, En Sup;Kim, Tae-Ok
    • Journal of the Korean Institute of Gas
    • /
    • v.22 no.6
    • /
    • pp.136-143
    • /
    • 2018
  • Cellular automata have been applied to simulations in many fields such as astrophysics, social phenomena, fire spread, and evacuation. Using cellular automata, this study develops a model for consequence analysis of the dispersion of hazardous chemicals, which is required for risk assessments of and emergency responses for frequent chemical accidents. Unlike in cases of detailed plant safety design, real-time accident responses require fast and iterative calculations to reduce the uncertainty of the distribution of damage within the affected area. EPA ALOHA and KORA of National Institute of Chemical Safety have been popular choices for these analyses. However, this study proposes an initiative to supplement the model and code continuously and is different in its development of free software, specialized for small and medium enterprises. Compared to the full-scale computational fluid dynamics (CFD), which requires large amounts of computation time, the relative accuracy loss is compromised, and the convenience of the general user is improved. Using Python open-source libraries as well as meteorological information linkage, it is made possible to expand and update the functions continuously. Users can easily obtain the results by simply inputting the layout of the plant and the materials used. Accuracy is verified against full-scale CFD simulations, and it will be distributed as open source software, supporting GPU-accelerated computing for fast computation.

Older Drivers' Perception and Attitudes Towards Driving Cessation (노년기 운전중단 결정 인식과 태도에 관한 연구)

  • Choi, Moon Jeong;Oh, HakJun;Suh, Yi-Jong
    • 한국노년학
    • /
    • v.38 no.3
    • /
    • pp.593-605
    • /
    • 2018
  • This study examines factors that influence older drivers to consider stopping driving in advance and whose advice plays an important role in the driving cessation decision. Data came from a nationally representative cross-sectional survey of community-dwelling older adults (N=2,076). About two thirds reported that they have considered stopping driving (62.8%) and they preferred to decide by themselves (66.0%). Logistic regression results showed that women and residents in urban areas were twice as likely to consider voluntary driving cessation compared to their counterparts. Each one year increase in age contributed to the probability that respondents would consider driving cessation by five percent. Those with greater difficulties in ADLs due to chronic illnesses were also more likely to consider driving cessation. No sociodemographic and health factors were related to whether older drivers preferred to decide by themselves or listen to others. These results imply that policies to promote self-motivation to stop driving among older drivers would be effective. Furthermore, they suggest it could be important to help older drivers plan their driving cessation in advance while still at a young-old age, and that more attention needs to be paid to men and those living in rural areas among older drivers.

A study on the field application of high strength steel pipe reinforcement grouting (고강도 강관 보강 그라우팅의 현장 적용성에 관한 연구)

  • Shin, Hyunkang;Jung, Hyuksang;Ryu, Yongsun;Kim, Donghoon
    • Journal of Korean Tunnelling and Underground Space Association
    • /
    • v.21 no.4
    • /
    • pp.455-478
    • /
    • 2019
  • In this paper, we conducted experimental investigation on the field applicability through the verification of reinforcement effect of the steel pipe reinforcement grouting using high strength steel pipe. SGT275 (formerly known as STK400) steel pipe is generally applied to the traditional steel pipe reinforcement grouting method. However, the analysis of tunnel collapse cases applying the steel pipe reinforcement grouting shows that there are cases where the excessive bending and breakage of steel pipe occur. One of the reasons causing these collapses is the lack of steel pipe stiffness responding to the loosening load of tunnels caused by excavation. The strength of steel pipe has increased due to the recent development of high strength steel pipe (SGT550). However, since research on the reinforcement method considering strength increase is insufficient, there is a need for research on this. Therefore, in this study, we conducted experiments on the tensile and bending strength based on various conditions between high strength steel pipe, and carried out basic research on effective field application depending on the strength difference of steel pipe through the conventional design method. In particular, we verified the reinforcement effect of high strength steel pipe through the measurement results of deformed shape and stress of steel pipe arising from excavation after constructing high strength steel pipe and general steel pipe at actual sites. The research results show that high strength steel pipe has excellent bending strength and the reinforcement effect of reinforced grouting. Further, it is expected that high strength steel pipe will have an arching effect thanks to strength increase.

Enzymatic synthesis of benzyl alcohol galactoside using Escherichia coli β-galactosidase (대장균 β-galactosidase를 이용한 benzyl alcohol galactoside의 합성 연구)

  • Jung, Kyung-Hwan
    • Journal of the Korean Applied Science and Technology
    • /
    • v.36 no.2
    • /
    • pp.572-580
    • /
    • 2019
  • Recently, it has been reported that benzyl alcohol (BzOH) as an additive in cosmetics, food, and medicine lead to toxicity and allergy problem. Then, to circumvent this hurdle, we carried out the synthesis of benzyl alcohol galactoside (BzO-gal). Previously, it was confirmed that BzO-gal was synthesized by transgalactosylation reaction using Escherichia coli (E. coli) ${\beta}$-galactosidase (${\beta}-gal$). Meanwhile, in this study, two peaks of BzO-gal as sodium adduct ion (m/z=293.1004) and protonated ion (m/z=271.1180) were detected in the reaction mixture by liquid chromatography/electrospray ionization mass spectrometry (LC/ESI-MS). In addition, the amount of ${\beta}-gal$ and BzOH concentration, temperature, pH, and lactose concentration, respectively, were optimized (${\beta}-gal$, 0.75 U/mL; BzOH, 185 mM; temperature, $40^{\circ}C$, pH, 7.5; lactose, 350 g/l). Under these optimal conditions, 185 mM BzOH was converted into about 131 mM BzO-gal, in which the conversion yield was about 72%. In the future, BzO-gal will be applicable as a substitute for BzOH as a less toxic preservative for the cosmetic, pharmaceutical, and food industries, and we are planning to investigate the characteristics of BzO-gal as a preservative.

Evaluation of Shear Strength by Experiment and Finite Element Analysis of SFRC Hollow Members (SFRC 중공 부재의 실험 및 유한요소 해석에 의한 전단강도 평가)

  • Kim, Seong-Eun;Jeong, Jae-Won;Kim, Seung-Hun
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.23 no.4
    • /
    • pp.78-85
    • /
    • 2019
  • This study targets SFRC hollow members with small depth under shear force and bending. To evaluate the effect of web width on shear strength of SFRC members, experiment and finite element analysis were conducted and compared with existing equations. The web width was planned to be 1/2 times and 2/3 times, and the shear span ratio was planned to be 1.5 times. In the shear test results, the maximum shear strength increased by 10.3 to 28.0% with the web width increased by 33%. When the overall depth of specimens was increased by 1.5 times, the shear strength of the specimen with a web width of 100mm was increased by 29.2%. On the other hand, specimen with the 150mm only increased by 11.3%. These results indicate that the smaller the web width, the greater the shear strength increase with the increase of depth. Also, the smaller the web width, the greater the contribution of steel fiber. It has been shown that the KCI code evaluates the shear strength of experiments as very safe side, and that the proposed formula of Shin et al. predicts the experimental strength relatively well. As the web width increases by 2, 3, and 6 times, the mean shear strength by FEA appears to be 1.18, 1.80, and 2.19 times respectively. This indicates that the shear strength does not increase in proportion to the increase in web width.