• Title/Summary/Keyword: 아질산성질소

Search Result 63, Processing Time 0.019 seconds

아질산성 질소의 축적에 대한 용존 산소와 free ammonia의 영향 연구

  • Han, Dong-U;Lee, Su-Cheol;Lee, Nam-Hui;Kim, Dong-Jin
    • 한국생물공학회:학술대회논문집
    • /
    • 2000.11a
    • /
    • pp.475-478
    • /
    • 2000
  • For an integrated nitrification-denitrification process, nitrite formation in the aerobic stage leads to big savings. Dissolved oxygen concentration, temperature, pH and free ammonia concentration have been meet for nitrite accumulation. Also their effects over the ammonia oxidizers and nitrite oxidizers have been studied. Dissolved oxygen limitation and free ammonia inhibition led to slow nitrification and nitrite build up. In this study batch kinetics of ammonium and nitrite oxidations were performed with free ammonia accumulated nitrifiers. From the results it is likely the nitrite oxidizers are inhibited by oxygen limitation rather than free ammonia.

  • PDF

Decomposition of 2,4,6-Trinitrotoluene (TNT) by Gamma Ray Irradiation (감마선 조사에 의한 2,4,6-Trinitrotoluene (TNT)의 분해)

  • Lee, Byung-Jin;Lee, Myun-Joo
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.27 no.1
    • /
    • pp.1-10
    • /
    • 2005
  • The purpose of this study was to evaluate the potential of a gamma irradiation to decompose 2,4,6-trinitrotoluene(TNT) in an aqueous solution. The decomposition reaction of TNT by gamma irradiation was a pseudo first-order kinetic over the applied initial concentrations($25{\sim}100mg/L$). The dose constant was strongly dependent on the initial TNT concentration. The removal of TNT was more efficient at pH below 3 and at pH above 11 than at neutral pH(pH 5-9). The required irradiation dose to remove over 99% of TNT was 40, 80 and 10 kGy, individually at pH 2, 7 and 13. The dose constant was increased by 1.6 fold and over 15.6 fold at pH 2 and 13, respectively, when compared with that at pH 7 When irradiation dose of 200 kGy was applied, the removal efficiencies of TOC were 91, 46 and 53% at pH 2, 7 and 13, respectively. Ammonia and nitrate were detected as the main nitrogen byproducts of TNT and glyoxalic acid and oxalic acid were detected as organic byproducts. The results showed that a gamma irradiation was an attractive method for the decomposition of TNT in an aqueous solution. However, regarding the application of high energy radiation for the TNT decomposition and mineralization, an application of an acidic pH below 3 to the solution before irradiation should be considered.

Physico-chemical and Microbiological Analysis of Tap Water in the Apartment in Taegu City (대규모 음용수 저장시설의 수질평가)

  • Kim, Seck-Bhum;Kang, Pock-Soo;Chung, Jong-Hak
    • Journal of Yeungnam Medical Science
    • /
    • v.5 no.1
    • /
    • pp.69-75
    • /
    • 1988
  • The drinking water in the apartment is stored in reservior tank and thereafter supplied each household. In case the drinking water is stored too long or insanitary, tap water might change in quality. This study was carried out to evaluate the physico-chemical and microbiological conditions of 36 samples of tap water of apartments compared to 18 samples of tap water of independence houses in Taegu City from May to October, 1987. Main findings are summarized as follows : PH values were within normal range in all samples. Samples less than 0.2ppm in residual chlorine accounted for 16.7% in the appartment and 5.6% in the independence house. Nitrite nitrogen was detected 2.8% of apartment samples only. Among the total of 54 samples, 11.1% of the apartment and independence samples were over the normal value in standard plate count. Samples more than 1.8 of most probable number(MPN) accounted for 27.8% in the apartment and 33.3% in the independence house. In result of test for residual chlorine, nitrite nitrogen, standard plate count, and MPN, the proportion of the samples revealed inappropriated in respect of drinking water standards. In case of all sorts of tests was 2.7% in apartment and nothing in independence houses, in case of 3 sorts of tests was 2.7% in apartment and 5.6% in independence houses, in case of 2 sorts of tests was 8.3% in apartment and 5.6% in independence houses, and in case of only 1 test was 25.0% in apartment and 22.2% in independence houses. Correlation between residual chlorine and standard plate count, and between standard plate count and MPN were observed. It was found that the more years since construction of apartment were, the worse tap water was in quality.

  • PDF

Effects of Environmental Factors on Nitrite Accumulation in a Strong Nitrogen Removal System (고농도 질소폐수 처리 공정에서 환경인자가 아질산염 축적에 미치는 영향)

  • Park, Noh-Back;Choi, Woo-Yung;Yoon, Ae-Hwa;Jun, Hang-Bae;Park, Sang-Min
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.24 no.1
    • /
    • pp.51-62
    • /
    • 2010
  • The high concentration of N in the wastewater from livestock farming generally renders the efficiency of the wastewater treatment. Therefore, removal of N in livestock wastewater is crucial for successful treatment. The current study was conducted to investigate the optimum conditions for partial nitrification under anaerobic condition following nitritation in TPAD-BNR(two-phase anaerobic digestion-biological nitrogen removal) operating system. Sequential operating test to stimulate partial nitrification in reactor showed that partial nitrification occurred at a ratio of 1.24 in $NO_2{^-}$-N:$NH_4{^+}$-N. With this result, a wide range of factors affecting stable nitritation were examined through regression analysis. In the livestock wastewater treatment procedure, the hydraulic retention time (HRT) and pH range for optimum nitrite accumulation in the reactor were 1-1.5 days and 7-8, respectively. It was appeared that accumulation of $NO_2{^-}$-N in the reactor is due to inhibition of the $NO_2{^-}$-N oxidizer by free ammonia (FA) while the effect of free nitrous acid was minimal. Nitrification was not influenced by DO concentration at a range of 2.0-3.0 mg/L and the difference in the growth rate between $NH_4{^+}$-N oxidizer and $NO_2{^-}$-N oxidizer was dependent on the temperature in the reactor.

Nitrite Accumulation of Anaerobic Treatment Effluent of Slurry-type Piggery Waste (슬러리상 돈사폐수의 혐기성 처리수의 아질산성 질소 축적)

  • Hwang, In-Su;Min, Kyung-Sok;Yun, Zuwhan
    • Journal of Korean Society on Water Environment
    • /
    • v.22 no.4
    • /
    • pp.711-719
    • /
    • 2006
  • The effluent from anaerobic digestion process of slurry-type piggery waste has a characteristic of very low C/N ratio. Because of high nitrogen content, it is necessary to evaluate nitrogen removal alternative rather than conventional nitrification-denitrification scheme. In this study, two parallel treatment schemes of SBR-like partial nitritation reactor coupled with anaerobic ammonium oxidation (ANAMMOX) reactor, and a nitritation reactor followed by nitrite denitrification process were evaluated with a slurry-type piggery waste. The feed to reactors adjusted with various $NH_4-N$ and organics concentration. The nitrite accumulation was successfully accomplished at the loading rate of about $1.0kgNH_4-N/m^3-day$. The $NO_2-N/NH_4-N$ ratio 1~2.6 in nitritated effluent that operated at HRT of 1 day indicated that SBR-like partial nitritation was applicable to ANAMMOX operation. Meanwhile, the nitrite accumulation of 87% was achieved at SBR operated with HRT of 3 days and $0.4mgO_2/L$ for denitritation. Experimental results further suggested that HRT (SRT) and free ammonia(FA) rather than DO are an effective control parameter for nitrite accumulation in piggery waste.

Analysis of Water Quality and Heavy Metals for Surface Water and Sediments of Upstream and Midstream in Nakdong River (낙동강 중 · 상류지역 하천의 표류수 및 퇴적층의 중금속 및 수질분석)

  • Ri, Chang Seop
    • Journal of the Korean Chemical Society
    • /
    • v.44 no.6
    • /
    • pp.547-555
    • /
    • 2000
  • The surface water in the upstream and midstream of Nakdong river, which is being used as tap water and industrial water supply in Daegu city and Kyungpook province, was analyzed in its water quality. In addition, the sediments of which was analyzed in terms of heavy metal and organic substance contents. All the sampling was done in the drought season for 2 days of June 22-23 and carried out in 10 sampling sites. The sites cover the whole Kyungpook provincial region, starting from Yangsam Bridge in Chyeong Ryang Provincial Park as the upper end, to the Ko Ryung Bridge as the lower end sampling site of Nakdong river that flows through Kyungpook province. The 22 items including $NH^{+}_{4}$, $NO^{-}_{2}$ and COD were analyzed for surface water and 11 items including organic constituents(trichloroethylene, etc) and heavy metals were analyzed for sediments. The sediments samples were analyzed by elution testing method and acid dissolution method and then the results were compared with each other. All heavy metals in samples were determined by Inductively Coupled Plasma-Atomic Emission Spectroscopy(ICP-AES) and other constituents were analyzed by standard testing methods of the Korean Ministry of Environment.

  • PDF

Water Treatment of Seawater Recirculating Aquaculture System by Using Three Phase Fluidized Bed Reactor (삼상 유동층 반응조를 이용한 해수 순환 여과 시설의 수처리)

  • Lee, Byung-Hun;Choi, Hyeok;Ryu, Jong-Soo
    • Journal of Aquaculture
    • /
    • v.13 no.2
    • /
    • pp.137-145
    • /
    • 2000
  • Capacity of water treatment of the three phase fluidized bed reactor as a biofilter in the seawater recirculating system was evaluated. The water treatment system consists of fluidized bed reactor for ammonia removal, cartridge filter for solid removal and ozone contactor for disinfection. Mean concentration of water quality parameters: COD, TAN, $NO_2$-N, $NO_3$-N, SS and alkalinity were 9.0, 0.22, 0.05, 20.0, 9.5 and 70.0 mg/l, respectively; the relevant values were 7.6 for pH and 3.64 NTU for turbidity. These indicate the maintenance of good water quality by the treatment system. The influent TAN loading rate in to the fluidized bed reactor ranged from 4.3 to 32.9 g/$m^3$/day, and averaged to 20 g/$m^3$/day. TAN removal efficiency of each phase of the fluidized bed reactor was 47-60%, indicating the effective ammonia removal. During operation the effluent of fluidized bed reactors also maintained the unionized ammonia nitrogen level below 0.002 mg/l.

  • PDF

Effective Reservoir Management Methods using Nutrients Leaching Characteristic Analysis: Case Study of the Hongdong Reservoir (홍동저수지 퇴적토의 유기물 용출 특성 분석을 통한 효율적인 저수지 관리 방안 연구)

  • Lee, Young-Shin;Shin, Sang-Hee
    • The Journal of Engineering Geology
    • /
    • v.23 no.2
    • /
    • pp.95-104
    • /
    • 2013
  • This study proposes an efficient management plan for improving the water quality of agricultural reservoirs. Hongdong reservoir is located in an area that includes farmland, forest, residential housing, and livestock farms. The levels of pollutants in Hongdong reservoir were investigated with the aim of improving the water quality in the reservoir. The potential concentrations of total nitrogen (T-N) and total phosphorus (T-P) in Hongdong reservoir were 1.06-3.67 and 0.52-1.12 $g/m^2-d$, respectively. An analysis of leaching characteristics was performed under anaerobic conditions for 72 hours at $20^{\circ}C$. The concentrations of T-P and $PO_4$-P were measured by general leaching for a set period. In the case of T-P, the leaching was measured by irregular leaching due to denitrification of nitrite nitrogen ($NO_2$-N) and nitrate nitrogen ($NO_3$-N). A very small amount of $NH_3$-N on nitrogen ($N_2$) was measured due to the low pH in the column, as a consequence of the anaerobic conditions.

Intensive Culture of the Pacific White Shrimp Litopenaeus vannamei, under Limited Water Exchange - II. Indoor Post-Nursery Culture of Juvenile Shrimp - (사육수 비교환 방식에 의한 흰다리새우의 고밀도 사육 - II. 흰다리새우의 실내 중간양성 -)

  • Jang, In-Kwon;Kim, Jong-Sheek;Seo, Hyung-Chul;Cho, Kook-Jin
    • Journal of Aquaculture
    • /
    • v.22 no.1
    • /
    • pp.42-50
    • /
    • 2009
  • Shrimp farming which is entirely conducted in outdoor ponds in the west coast of Korea has been suffered from mass mortality due to viral epizootics. Intensive indoor shrimp culture under limited water exchange can solve these problems of outdoor ponds including viral transmission from environment, pollution due to discharge of rearing water, low productivity and limited culture period. In this study, juvenile L. vannamei (B.W. 0.08-0.09 g) was stocked with $3,000-5,455/m^3$ in density in four raceway tanks (two $12.9\;m^2$, two $18\;m^2$ tanks) and cultured for 42 days with 2.7-3.4% of daily water exchange. Results from four tanks showed FCR of 0.79-1.29, survival of 38.2-48.0%, and yields of $2.49-4.22\;kg/m^3$ which is consistent with 12-20 and 8-14 times higher than those of commercial shrimp hatchery and outdoor pond in Korea, respectively. Concentrations of total ammonia nitrogen in all four tanks were 1.11-1.42 ppm in mean level and did not exceed 6.0 ppm (0.096 ppm of $NH_3$) which is still acceptable levels for shrimp growth. During the culture trial, concentration of $NO_2$-N rapidly increased from stocking, resulting in mean concentration of 18.45-22.07 ppm. It also exceeded 10 ppm over four weeks and maintained at 35-45 ppm for four days in all tanks, accounting for low survival of shrimp due to long-term exposure to high concentration of $NO_2$-N. Nevertheless, the results with survival rate over 38% from raceways which experienced the extreme $NO_2$-N levels suggests that under "biofloc system" white shrimp can acclimate to high $NO_2$-N concentration to some degree.

Mass Reduction and Physicochemical Properties of the Produced Compost during Composting Domestic Food Wastes in a Small Composter (소형 퇴비화용기에서 가정 음식물쓰레기의 퇴비화 과정 중 감량화 및 생산 퇴비의 물리화학적 특성)

  • Park, Ju-Won;Seo, Jeoung-Yoon
    • Korean Journal of Environmental Agriculture
    • /
    • v.20 no.4
    • /
    • pp.238-243
    • /
    • 2001
  • Mass reduction and physicochemical properties of the produced compost were investigated during composting domestic food wastes without additive. A small composter used in this study had the height of 15 cm from the center of bottom half circle (diameter 24 cm) up to under the lid, the side length of 50 cm and the horizontal lid angle of $50^{\circ}$ and was operated at the heating unit temperature of $85^{\circ}$. It was mixed by the rotating arm for two minutes in every half hour while supplied with air flow at 3 L/min for 10 minutes in every half hour. This condition was found in a preliminary experiment as optimal for keeping the water content of composting material in the optimal range without adding any bulking materials. The domestic food wastes were added into the composter at the rate of 1 kg/day without additives during composting. The results were as follows; during the composting process, water content maintained in the range of $51.0{\sim}53.5%$. Hemicellulose and lignin contents did not show any tendency, but cellulose content decreased. During the composting process, $NH_3-N$ and $NO_2-N$ were not detected due to nitrification. The contents of inorganic compounds did not increase during the composting process. They were in the range of $1.32{\sim}1.71%\;P_2O_5$, $1.29{\sim}1.48%\;CaO$, $0.41{\sim}0.49%\;MgO$, and $0.38{\sim}0.74%\;K_2O$. For 20 days, weight reduction rate was 67.5% in wet basis, and decomposition rate was 48% in dry basis. Concentration of heavy metals (Cu, Cr, Cd, Pb, Zn, Hg, As) was less than the limiting value of the compost. Maturity of the produced compost was 3 grade through reaching maximum temperature of $46{\sim}48^{\circ}C$.

  • PDF