• 제목/요약/키워드: 심장 판막

검색결과 786건 처리시간 0.031초

인공판막을 치환받은 산모에서의 임신

  • 이석열;장병철;박한기;유경종;강면식;조범구;박용원
    • Proceedings of the KTCVS Conference
    • /
    • 대한흉부외과학회 1996년도 제 28차 추계학술대회 및 총회 대한흉부외과학회
    • /
    • pp.48-48
    • /
    • 1996
  • PDF

Surgical Management of Aortic Valve Injury after Nonpenetrating Trauma (외상성 대동맥 판막 손상의 수술적 처치)

  • Seo, Yeon-Ho;Kim, Kong-Soo;Kim, Jong-Hun
    • Journal of Chest Surgery
    • /
    • 제40권3호
    • /
    • pp.232-235
    • /
    • 2007
  • We present 2 cases of patients who underwent surgical repair and replacement of an injured aortic valve that was secondary to nonpenetrating trauma. Primary repair was undertaken on an 18-year old boy, but he had persistent moderate aortic regurgitation for five years after surgery. Another 64-year old man was treated successfully with surgical replacement of the aortic valve via employing a prosthetic mechanical valve. Attempts at valvuloplasty for the treatment of traumatic aortic valve injury have not been uniformly successful, and prosthetic valve replacement is recommended for repair, except for highly selected cases.

Early Clinical Outcome and Doppley Echocardiographic Data after Cardiac Valve Replacement with the ATS prosthesis (ATS 인공 판막의 조기 임상성적 및 도플러 심에코 검사 소견)

  • 박계현;박승우
    • Journal of Chest Surgery
    • /
    • 제30권7호
    • /
    • pp.663-669
    • /
    • 1997
  • This is a report on the clinical outcome and hemodynamic profile of the ATSwcardiac valve prosthesis, which is a recently introduced pyrolytic carbon bileaflet prosthesis. We retrospectively reviewed the early outcome of 100 consecutive patients who underwent isolated cardiac valve replacement with the ATS(w prosthesis from October 1994 through June 1996 at our hospital. All patients were evaluated with Doppler echocardiography before discharge from the hospital. The mean age of the patients was 48.6 years(range: 2 to 74). A tota of 124 prosthesis were implanted; 71 mitral, 46 aortic, and 7 tricuspid. The two most frequently used sizes were 27 mm(40.8%) and 29 mm(35.2%) in the mitral position, and 23 mm(30.4%) and 21 mm(28.3%) in the aortic position. There was no early or late death. The total follow-up period was 950 patient-months with 99% follow-up rate. Serious late morbidity occurred in three patients; reoperation in two patients for late rupture of Sinus of Valsava in one and for endocarditis with prosthetic dehiscence in the other, and intracranial hemorrhage due to hypertension in one patient. There has been no thromboembolic complication or structural valval deterioration. In the mitral position, the average values of peak and mean transprosthetic pressure gradients and valve area calculated from pressure half time were 6.9$\pm$2.8 mmHg, 2.6$\pm$ 1.5 mmHg, and 2.7 $\pm$0.8 cm2 respectively. In the aortic position, the peak and mean pressure gradients'were 26.4 $\pm$ 15.9 mmHg and 14.2 $\pm$ 7.9 mmHg. For the mitra prostheses larger than 25-mm size, there was no significant difference among prosthetic sizes in terms of transprosthetic gradients, whereas there was a significant negative correlation between the prosthesis size and the transprosthetic gradients for the aortic valves. The peak and mean Pressere pradients were 52.2 $\pm$ 17.6 tmHg and 26.9$\pm$ 7.4 mmHg across the 19-mm aortic Prostheses, and 27.1 $\pm$ 11.9 mmHg and 13.3$\pm$6.6 mmHg across the 21-mm size. Above results can lead to the conclusion that the early clinical outcome of the ATS valve prosthesis is quite satisfactory, And the hemodynamic characteristics are comparable, if not better, with other bileaflet prostheses.

  • PDF