• Title/Summary/Keyword: 심장 판막

Search Result 786, Processing Time 0.026 seconds

The Surgical Treatment of Atrial Fibrillation in Patients Undergoing Simultaneous Open Heart Surgery (심장세동의 수술요법)

  • Kim, Gi-Bong;Lee, Chang-Ha;Son, Dae-Won
    • Journal of Chest Surgery
    • /
    • v.30 no.3
    • /
    • pp.287-292
    • /
    • 1997
  • .Itrial fibrillation is one of the most common cardiac arrhythmias requiring treatment. About 60% of patients with mitral valvular disease have atrial fibrillation and one third of patients with atrial fibrillation may have the past history of thromboembolic events. Between April 1994 and June 1995, 20 patients with organic heart diseases combined with atrial fibrillation underwent open heart surgery including Cox-maze 111 procedure. There were 6 men and 14 women with an average age of 48 years (range, 31 to 66 years). Nineteen patients had valvular heart diseases and 1 ventricular septal defEct (VSD). Mean duration of atrial fibrillation was 36 months (:42 months) (range, 1 to 132 months). T e past medical history of thromboembolic events was positive in 7 patients (35%) and left atrial thrombus was detected in 9 patients (45%). The concomitant procedures were mitral valve replacement (MVR) and aortic valve replacement (AVR) in 5 patients, MVR in 4, MVd and tricuspid annuloplasty(TAP) in 4, mitral valvuloplasty(Mln) in 3, Mln and Tln in 1, MIW and coronary artery bypass surgery in 1, AVR in 1, and patch closure of VSD in 1. Mean aortic cross-clamping time was 175 minutes (range, 116 to 270 minutes). Atrial fibrillation recurred in 16 patients (80%) during the early postoperative period, but, recurrent atrial fibrillation was converted to regular rhythm at postoperative forty-first day in average. There was no early or late death in this series of 20 patients and postoperative complications were inappropriate tachycardia in 5 patients (25%), low cardiac output syndrome in 3 (15%), aggravated hemiplegic in 1, and acute renal failure in 1. Mean follow-up interval of patient was 16.5 months (range, 10.5 to 24 months) and all patients are currently in regular rhythm. Seventeen patients (85%) are in sinus rhythm and 3 (15%) in junctional rhythm. Right atrial contraction was detected in 95% of patients and left atrial contraction in 63% on postoperative transthoracic echocardiogram. The surgical treatment of atrial fibrillation concomitant with open heart surgery is warranted in the recent clinical setting of improved myocardial protection technique, considering the untoward side-effects of atrial fibrillation.

  • PDF

Long Term Experience of Mitral Valve Replacement (승모판치환수술의 장기 임상성적)

  • 조용길;류지윤
    • Journal of Chest Surgery
    • /
    • v.29 no.10
    • /
    • pp.1102-1110
    • /
    • 1996
  • Between Oct. 1985 and July 1995, 230 patients underwent mitral valve replacement. There were 77 men and 153 women whose mean age was 35.7 years, range 9 to 62 The concomitant operations were 40 aortic valve replacements(17.4%), 25 tricuspid annuloplasties(10.4%), 8 aortic valve replacements & tricuspid annuloplasties(3.5%), 2 tricuspid valve replacements(0.9%) and others, We used 139 mechanical (76 51. Jude medical, 33 CarboMedics, 30 Sorin) and 91 tissue 386 Carpentier-Edwards, 5 lonescu-Shiley) valves. The early postoperative complications occurred in 28 cases. There were 8 low cardiac output syndrome, 5 pleural effusion, 3 significant arrhythmia, 2 cardiac rupture and others. There were 6 early hospital deaths (2.6%) due to low cardiac output syndrome(2), arrhythmia(2) and ventricul r rupture(2). The cuAmulative notal follow-up period was 764. 4 patient-years with a mean of 4).9 months. The long term follow-up information was available for 212 patients(94.6%). There were 21 cases of valve-related complications. Prosthetic valve failure(10), anti-coagulation related bleeding (5), prosthetic valve endocarditis (4), and thromboembolism (2) occurred at rates of 1.3, 0.7, 0.5, and 0.3%Ipt-yr respectively. Late death occurred In 5 cases (0.7%/pt-yr) associated with prosthetic valve endocarditis (2), heart failure (2) and anti-coagulation related bleeding (1). There was no difference in the rate of freedom from prosthetic valve failure between the mechanical and tissue valve group at 6 years (100%), but there was significant difference at 9 years between the tissue (34.4%) and mechanical valve (100%) group (p=0.032). Actuarial survival rates were 98. 8% in tissue valve. 9).7% in mechanical valve group and 96.6% in total patients at 9 years.

  • PDF

Trido Mitral Valve Replacement with Dacron Collar Prosthetic Valve due to Paravalvular Leak (판막주위 누출에 대한 다크론 확장 인공판막을 이용한 판막치환술 치험)

  • 배윤숙;정성철;김우식;정승혁;이정호;김병열
    • Journal of Chest Surgery
    • /
    • v.35 no.11
    • /
    • pp.822-825
    • /
    • 2002
  • The paravalvular leak after redo mitral prosthetic valve replacement is rare but serious complication when it does happen. This condition should be corrected surgically to increase life span and improve symptoms. But simple closure or patch closure of paravalvular leak are not effective in cases of weak annulus or broad defect. We report 3 cases of trido mitral valve replacement using mechanical valve with its sewing ring expanded by a collar of Dacron sheet. The prosthetic sewing ring is anchored on the weak mitral annulus with multiple interrupted sutures, while the Dacron collar is contineuously sutured to the left atrial wall for blood tight sealing. All of the three cases showed event free postoperative course.

Congenital Aortic Valvular Insufficiency Caused by Abnormal Valvular Structures in a Labrador Retriever Dog (래브라도 리트리버종 개의 비정상 판막 구조에 의한 선천성 대동맥 판막 부전)

  • Moon, Hyeong-Sun;Lee, Seung-Gon;Lee, Sang-Eun;Hyun, Chang-Baig
    • Journal of Veterinary Clinics
    • /
    • v.24 no.2
    • /
    • pp.233-237
    • /
    • 2007
  • A 10-month-old intact male Labrador Retriever dog was referred with the primary complaint of exercise intolerance, especially after vigorous exercise. Physical examination revealed split S1 and grade III/VI diastolic regurgitant murmur at the left apex and base, respectively. ECG finding was normal sinus rhythm at rest, but supraventricular tachycardia with bundle branch blocks after exercise. Thoracic radiography revealed dilated ascending aorta with normal range of cardiac silhouette (VHS 10.2). Echocardiography revealed abnormal valvular structures just above the aortic valvular cusps causing aortic regurgitation with a reduction of left ventricular ejection fraction (LVEF). Based on those findings, the case was diagnosed as congenital aortic regurgitation caused by abnormal valvular structures. The dog was managed with diltiazem and exercise restriction. This is a rare case of aortic deformity in dogs.

Clinical Experiences of Open Heart Surgery (개심술(開心術) 2,000례의 임상적 고찰)

  • 김하늘루;박경택;곽기오;한일용;소영환;최강주;이양행;조광현
    • Journal of Chest Surgery
    • /
    • v.31 no.12
    • /
    • pp.1183-1194
    • /
    • 1998
  • Background: From Sept. 1985 to Sept. 1997, 2,000 cases of open heart surgery(OHS) were performed in the Department of Thoracic & Cardiovascular Surgery, Pusan Paik Hospital, College of Medicine, Inje University. Material and Method: Among the total of 2,000 cases of OHS, 1532 cases were congenital heart disease(CHD) and 468 cases were acquired heart disease(AHD). The age distribution was 9 days(4.0kg) to 68 years in CHD and 11 to 66 years in AHD. In 1532 cases of CHD, there were 1403 acyanotic cases and 129 cyanotic cases. Result: The CHD cases consisted of 940 ventricular septal defects(61.4%), 324 atrial septal defects(21.1%), 112 tetralogy of Fallot(7.3%), 46 pulmonary stenosis(3%), 38 endocardial cushion defects(2.5%), 15 valsalva sinus ruptures(1%), 4 transposition of great arteries (0.3%), 4 double outlet right ventricles(0.3%), and etc. Corrective operations were applied for congenital heart disease with a result of 3.1% hospital mortality. Of 468 AHD, 381 cases were valvular heart diseases, 48 ischemic heart diseases, 12 cardiac tumors, 8 annuloaortic ectasias, 16 dissecting aortic aneurysms and etc. In the 381 valvular heart diseases, there were 226 single valve replacements(36 aortic valve replacements(AVR), 188 mitral valve replacements(MVR), and 2 tricuspid valve replacements(TVR), among these were 71 cases of double valve replacements(AVR & MVR), 54 cases of MVR with tricuspid valve annuloplasty(TVA), and 18 cases of AVR, MVR with TVA. The total implanted prosthetic valves were 466. In MVR, 123 St. Jude Medical valves, 90 Carpentier-Edwards valves, 65 CarboMedics valves, 42 Sorin valves and 16 other valves were used. In AVR, 68 St. Jude Medical valves, 36 CarboMedics valves, 14 Carpentier-Edwards valves and 9 other valves were used. Coronary Artery Bypass Surgery(CABG) were performed in 48 cases. The patterns of bypass graft were 14 patients of single vessel graft, 21 patients of two vessels graft, 10 patients of three vessels graft and 3 patients of four vessels graft. Conclusion: The hospital operation mortality rate of congenital acyanotic, cyanotic and acquired heart diseases were 2.0%, 15.5%, and 5.1% respectively. The overall mortality rate was 3.6%(72/2,000).

  • PDF

Long-term Results after 1,144 CarboMedics Mechanical Valve Implantation (CarboMedics 기계판막을 이용한 1,144예 판막치환술의 장기 성적)

  • Kang, Chang-Hyun;Kim, Kyung-Hwan;Kim, Ki-Boong;Ahn, Hyuk
    • Journal of Chest Surgery
    • /
    • v.37 no.7
    • /
    • pp.559-569
    • /
    • 2004
  • The CarboMedics mechanical valve has been reported to show acceptable valve-related complication rates. The aim of this study is to evaluate our clinical experience with the CarboMedics valve. Material and Method: Between August 1988 and September 1999, we implanted 1,144 CarboMedics valves in 850 patients (aortic 179; mitral 385; double-valve 234; tricuspid 52). The mean age was 44.5 $\pm$ 12.5 years. Follow-up was completed in 95.2% and median follow-up period was 7.9 years (6753 patient-years). Result: The overall hospital mortality rate was 3.4% and the mortality rate for each group was 1.7% for aortic group, 2.6% for mitral group, 4.7% for double-valve group, and 9.6% for tricuspid group, Tricuspid group showed significantly higher mortality rate than aortic and mitral group (p〈0.05). The actuarial survival at 10 years was 87.1 $\pm$ 2.6%, 88.9 $\pm$ 1.7%, 82.4 $\pm$ 2.9%, and 77.5 $\pm$ 7.0% for aortic, mitral, double, and tricuspid valve group, respectively. Age and tricuspid valve replacement were significant risk factors for long-term survival in multivariate analysis (p 〈 0.05). Freedom from valve thrombosis at 10 years was 99.4 $\pm$ 0.6%, 98.2 $\pm$ 0.8%, 99.2 $\pm$ 0.8%, and 87.6 $\pm$ 0.5% for aortic, mitral, double and tricuspid valve group. Tricuspid valve group showed significantly higher rate of valve thrombosis (p 〈 0.05). Conclusion: Long-term results of our experience demonstrated that CarboMedics valve showed acceptable incidence of valve-related complications. However, tricuspid valve replacement showed higher rate of early mortality and valve thrombosis than other valve replacement groups.

Biaxial Strain Analysis of Various Fixation Models in Porcine Aortic and Pulmonary Valves (돼지 대동맥 판막과 폐동맥 판막의 고정 방법에 따른 양방향 압력-신장도의 비교분석)

  • Cho, Sung-Kyu;Kim, Yong-Jin;Kim, Soo-Hwan;Choi, Seung-Hwa
    • Journal of Chest Surgery
    • /
    • v.42 no.5
    • /
    • pp.566-575
    • /
    • 2009
  • Background: The function of a bioprosthetic heart valve is determined largely by the material properties of the valve cusps. The uniaxial tensile test has been studied extensively. This type of testing, however, does not replicate the natural biaxial loading condition. The objective of the present study was to investigate the regional variability of the biaxial strain versus pressure relationship based on the types of fixation liquid models. Material and Method: Porcine aortic valves and pulmonary valves were assigned to three groups: the untreated fresh group, the fixed with glutaraldehyde (GA) group, and the glutaraldehyde with solvent (e.g., ethanol) group. For each group we measured the radial and circumferential stretch characteristics of the valve as a function of pressure change. Result: Radial direction elasticity of porcine aortic and pulmonary valves were better than circumferential direction elasticity in fresh, GA fixed and GA+solvent fixed groups (p=0.00). Radial and circumferential direction elasticity of pulmonary valves were better than aortic valves in GA fixed, and GA+solvent fixed groups (p=0.00). Radial and circumferential direction elasticity of aortic valves were decreased after GA and GA+solvent fixation(p=0.00), except for circumferential elasticity of GA+solvent fixed valves (p=0.785). The radial (p=0.137) and circumferential (p=0.785) direction of elasticity of aortic valves were not significantly different between GA fixed. and GA+solvent fixed groups. Radial (p=0.910) and circumferential (p=0.718) direction of elasticity of pulmonary valve also showed no significant difference between GA fixed and GA+solvent fixed groups. Conclusion: When fixing porcine valves with GA, adding a solvent does not cause a loss of mechanical properties, but, does not improve elasticity either. Radial direction elasticity of porcine aortic and pulmonary valves was better than circumferential direction elasticity.

Valve Replacement in an Anuric Patient with Chronic Renal Failure - 1 Case Report - (만성 신부전으로 인한 무뇨증 환자에서의 판막치환술 - 1례 보고 -)

  • Kim, Si-Hoon;Kwack, Moon-Sub;Lee, Sun-Hee;Park, Jae-Kil;Jin, Ung
    • Journal of Chest Surgery
    • /
    • v.32 no.6
    • /
    • pp.588-590
    • /
    • 1999
  • It is now generalized to perform cardiac surgery in the patients with end-stage renal disease. The growing number of patients with chronic renal failure wake us up to the need to prepare for proper management. There are not only the prevalence of coronary artery disease, but also a great amount of valve dysfunction exist in this group. Peritoneal dialysis may be one of the obstacles for cardiopulmonary bypass but it is not a great hindrance in cardiac surgery with careful preparation and well organized perioperative care. The author has performed mitral valve replacement in a 33-year-old anuric female patient with chronic renal failure and severe mitral insufficiency. Preoperatively, the patient was kept in adequate fluid and electrolyte balance using peritoneal dialysis. Peritoneal dialysis continued and regulated according to the laboratory data in this patient during and after the surgery. She recovered well showing an uneventful course and was discharged on postoperative 1 th day.

  • PDF

The Usefulness of Transesophageal Echocardiography During Heart Surgery (개심술을 시행하는 환자에서 경식도 심초음파의 이용)

  • 조규도;김치경
    • Journal of Chest Surgery
    • /
    • v.30 no.12
    • /
    • pp.1205-1213
    • /
    • 1997
  • This study reviewed useful aspects of the intraoperative transesophageal echocardiography among the patients in whom heart surgery were undertaken between January 1996 and July 1996 at St.Pauls hospital, Medical College of Catholic University, Seoul, Korea. During that period, 61 patients were operated on because of valvular heart disease(25 patients), coronary artery disease(22 patients), congenital heart disease(13 patients), and combined coronary artery disease and valvular heart disease(1 patient). Two patients(1 redo-VSD and 1 valvular heart diease) needed repeated aortic cross clamping and complementary procedures because of incomplete initial procedures. There was no incidence of air embolism. We could observe significant relationship of cardiac output monitoring methods either by thermodilution technique and transesophageal echocardiography by linear regression analysis(p<0.001). We tested myocardial response(percentage of systolic wall thickness, PSWT) with low dose dobutamine challenge to predict post-CABG myocardial perfusion. And the test showed statistically significant resp.onse(sensitivity 76%, specificity 94.7%, positive predictive value 95%, negative predictive value 75%). These results suggest that cardiac surgeon could draw more benefits by intraoperative transesophageal echocardiography.

  • PDF

Mitral Valve Replacement in Children Less Than 16 years of Age (소아에서의 승모판치환술)

  • 이흥렬;홍유선
    • Journal of Chest Surgery
    • /
    • v.29 no.10
    • /
    • pp.1090-1094
    • /
    • 1996
  • From February 1980 to September 1995, 31 children between 2 months and 15 years of age with mitral valve disease have undergone mitral valve replacement(MVR) at Yonsei Cardiovascular Center and com- plete follow-up has been obtained on 28 patients. There were 10 males and 18 females whose weight ranged from 4.9kg to 56kg. Two patients died early postopeiatively and the overall hospital mortality rate was 7.1%. These two were infants but there were no statistically significant difference in overall mortality among the age groups(p=0.13). The valve related complication rate was 57.1% in children younger than 5 years of age, which showed higher complication rate compared to older patients(p< 0.05). The bioprosthetic valve have been applied in 7 patients, and its 5-year valve failure-free survival rate was 50% . No mechanical valve failu e had occurred in 21 patients. In considering high re-replacement rate of bioprosthetic valve, mechanical valve is recommended despite its possibility of bleeding and thromboembolic complications. However, the consequences of increasing body size and long-term interposition of a rigid prosthesis in a growing heart will require second valve replacement. En conclusion, mitral valve replacement can be performed tilth satisfactory long-term survival in children, although younger mean age of the children has an important influence on early mortality and com- plication rate. And therefore mitral valve replacement in children younger than 5 years of age needs special consideration.

  • PDF