• Title/Summary/Keyword: 심미 치과학

Search Result 859, Processing Time 0.029 seconds

Evaluation of occlusal strength using T-Scan Novus and Dental prescale II in dental prosthodontic treatments: A case report (보철물 수복 형태에 따른 T-Scan Novus와 Dental prescale II를 이용한 교합력 평가 활용 증례)

  • Su-Hyun Choi;Yu-Sung Choi;Jong-Hyuk Lee;Seung-Ryong Ha
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.61 no.2
    • /
    • pp.160-178
    • /
    • 2023
  • Diagnosis and analysis of occlusal relationships are important factors in prosthetic treatment. A thorough occlusion analysis and evaluation should be performed before treatment to restore a stable interocclusal relationship. Analysis and evaluation are essential during the treatment process and at regular follow-ups. Recently, with the development of dental equipment and digital processing methods, new quantitative analysis methods that can record the patient's occlusal relationship have been introduced. Among them, the T-Scan Novus (Tekscan Inc., S. Boston, MA, USA) displays the strength of the initial contact point and the occlusal contact point of the teeth using a pressure sensor. With this, occlusal contact time of the teeth, anteroposterior and left-right balance of occlusal force can be compared. The Dental prescale II (GC Co., Tokyo, Japan) scans the occlusal contact point using a pressure-sensing film and analyzes the density of the contact point. It can measure the distribution and strength of the occlusal force of the teeth in the most natural occlusion state. Based on this, appropriate prosthetic treatment (four-unit fixed partial denture, removable partial denture, complete denture, and complete oral restoration cases) was performed according to the area and extent of the patient's tooth loss. The patient's occlusion at the first visit, treatment stage, right after treatment, and regular follow-up were compared and evaluated using a quantitative method for appropriate occlusion analysis using T-Scan Novus and Dental prescale II. This report enhances the understanding of occlusion analysis during prosthetic restoration. The results satisfied both the clinician and patients in terms of function and aesthetics.

Usage of digital technique to facilitate communication between dentist, dental lab technician, and patients in diagnosis and restoration for maxillary anterior implant: a case report (디지털 기법을 활용한 치과의사, 기공사, 그리고 환자 간의 효과적인 소통을 통한 전치부 임플란트의 진단 및 심미수복 증례)

  • Bang, Haemin;Jang, Woohyung;Park, Chan;Yun, Kwi-Dug;Lim, Hyun-Pil;Park, Sangwon
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.38 no.1
    • /
    • pp.42-51
    • /
    • 2022
  • Esthetic restoration of maxillary anterior implant heavily depends on the direction of installation of implant fixture. In patients with malpositioned implant, it is crucial to communicate the limitations of prosthetic outcome with the patient before starting on a restoration. To facilitate the communication, three-dimensional virtual representation by superimposing facial and intraoral digital scans with Computed Tomography (CT, dicom file) was used for visualization of the limitations of prosthesis. Through digital diagnostic wax-up, the profile of right maxillary anterior incisor implant was expected to be protrusive, which the patient was not satisfied with. Since the patient already had done root canal treatment on left maxillary anterior incisor due to previous trauma, a new prosthetic design including both right and left maxillary anterior incisors was presented to the patient. The second design was chosen and his comments were delivered to dental lab. The patient was satisfied with the new prosthesis, aesthetically and functionally.

Prosthetic rehabilitation using an obturator in a fully edentulous patient who had partial maxillectomy (상악골 부분 절제술을 받은 무치악 환자에서의 구강폐쇄장치 수복)

  • Chung, Yoo-Jin;Kim, Jong-Jin;Baik, Jin;Cha, Hyun-Suk;Lee, Joo-Hee
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.34 no.4
    • /
    • pp.331-337
    • /
    • 2018
  • Prosthetic rehabilitation of an edentulous patient who has a maxillary defect is difficult to achieve for many clinicians. The maxillary defect causes leakage of air during pronunciation and compromises denture stability, support and retention by reducing denture-bearing area and breaking peripheral seal. In these patients, the sizes and shapes of defects are very important factors which attribute to prognosis of maxillary obturators. This case report shows the prosthetic rehabilitation of the patient who had maxillectomy on the right maxillary sinus because of squamous cell carcinoma. The patient had a stepwise treatment protocol which started with pre-operative dental examination and followed by surgical, interim and definitive obturation phase. In this case, an acceptable level of retention could be obtained due to well-defined static defects and the preserved premaxillae and the patient was satisfied with the result of the treatment in the aspect of function and esthetics.

Rehabilitation of a patient by converting poorly maintained fixed implant prosthesis into implant overdenture: a case report (기존 임플란트 보철물의 불량한 유지관리를 개선하기 위해 임플란트 피개의치로의 상부 보철물 전환 증례)

  • Kim, Yeong-Kyu;Jeong, Chang-Mo;Yun, Mi-Jung;Lee, So-Hyoun;Huh, Jung-Bo
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.60 no.1
    • /
    • pp.127-134
    • /
    • 2022
  • Among many contributing factors of implant failure, excessive loading and inflammation contribute mainly to increasing implant failure rate. Especially, poor oral hygiene around implants is one of the most common reasons for implant failure. When implant prosthesis fails to function, the clinician should re-diagnose and plan treatment using the remaining implants. Additional implantation may be needed to make a new type of prosthesis or either implant-assisted RPD and implant overdenture treatment may be performed using the remaining implants. In this article, a patient whose fixed implant prosthesis in the maxilla had failed of poor oral hygiene maintenance was reported to be recovered with removable implant overdenture by using remaining implant abutments and a milled bar with additional retentive elements. Through this treatment, the clinical results were satisfactory in terms of esthetics, masticatory function recovery and oral hygiene management.

Full-mouth rehabilitation with increasing vertical dimension on the patient with severely worn-out dentition and orthognathic surgery history: A case report (악교정수술 병력을 가진 과도한 치아 마모를 보이는 환자의 수직고경 증가를 동반한 전악 수복 증례)

  • Sang-Myeong Tak;Chang-Mo Jeong;Jung-Bo Huh;So-Hyoun Lee;Mi-Jung Yun
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.61 no.1
    • /
    • pp.33-43
    • /
    • 2023
  • Pathological wear across the entire dentition causes problems such as collapsed occlusal plane, reduced vertical dimension, anterior premature contact, inadequate anterior guidance, and tooth migration, thereby induce symptoms such as temporomandibular joint disorder, reduced masticatory efficiency, and tooth hypersensitivity. For the treatment of patients with excessive wear, evaluation of vertical dimension should be preceded along with analysis of the cause. The patient in this case was a 45-year-old female with a history of orthognathic surgery. Through clinical examination, radiographic examination, and model analysis, overall tooth wear, interdental spacing in the anterior maxillary region, retruded condylar position, and insufficient interocclusal space for prosthetic restoration were confirmed. Full mouth rehabilitation with increased vertical dimension was planned, the patient's adaptation to the new vertical dimension was evaluated with a removable occlusal splint and temporary prosthesis, and cross-mounting was performed based on the temporary restoration to fabricate the definitive zirconia prosthesis, maintaining the adjusted vertical dimension. It showed satisfactory functional and esthetic results through stable restoration of the occlusal relationship.

Full mouth rehabilitation with implant fixed prostheses using POP bow system and 3D printing gothic arch tracer in a patient with unilateral facial nerve palsy (편측성 안면 신경마비 환자에서 3D printing gothic arch tracer와 POP bow system을 이용한 전악 임플란트 고정성 보철 수복)

  • Seong-Yun Jeong;Chang-Mo Jeong;Mi-Jung Yoon;Jung-Bo Huh;So-Hyoun Lee
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.62 no.3
    • /
    • pp.201-214
    • /
    • 2024
  • In patients with unstable mandibular movements who are accompanied by involuntary facial muscle movements and asymmetrical changes in the facial features, many difficulties exist in determining the vertical dimension of occlusion, recording centric relation, and transferring information about the occlusal plane. In this case, for a patient with unilateral facial nerve palsy who was edentulous for a long period of time, a CAD-CAM provisional prosthesis was fabricated using a 3D printing customized gothic arch tracer and a prefabricated occlusal plane recorder, the POP bow system, to achieve a stable interarch relationship. Afterwards, a full mouth implant fixed prosthesis was fabricated by delivering an appropriate vertical dimension of occlusion, a reproducible centric relation, and a correct three-dimensional occlusal plane, and continuous maintenance was performed to restore functional and aesthetic oral health to the patient.

In Vitro Study on the Bond Strength Between 3D-Printed Resin and Resin Cement for Pediatric Crown Restoration (소아용 크라운 수복을 위한 3D 프린팅 레진과 레진 시멘트 간의 접착 강도 평가)

  • So Yung Kim;Yoosoek Shin;Ik-Hwan Kim;Je Seon Song
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.50 no.1
    • /
    • pp.104-112
    • /
    • 2023
  • A 3D-printed resin crown is a novel option for esthetic crown restoration for primary teeth, which are typically bonded with resin cement. The purpose of this study was to evaluate the bonding ability of a 3D printing resin and compare it with other indirect resin materials for crown fabrication. The shear bond strengths of two 3D printing resin materials, Graphy (GP) and NextDent (NXT), and two indirect resin materials, VIPI Block (VIPI) and MAZIC Duro (MZ), were compared in the study. For all materials, the shear bond strength at the interface between the surface of the resin material and resin cement was measured. The mean shear bond strength values of GP, NXT, MZ, and VIPI were 23.29 ± 3.88, 26.14 ± 4.67, 25.41 ± 4.03, and 18.79 ± 4.26 MPa, respectively. There was no significant difference among the SBSs of GP, NXT and MZ except for VIPI. The result of this study indicates that the 3D printing resin meets the essential requirement for clinical use by showing clinically adequate bond strength.

A study on the smile according to age and esthetic evaluation by the degree of dental knowledge (연령에 따른 미소형태분석과 치과지식 정도에 의한 심미성 평가)

  • Kim, Seong-Jin;Kim, Moon-Gwan;Park, So-Min;Ban, Jae-Sam;Park, Sang-Won
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.50 no.4
    • /
    • pp.249-257
    • /
    • 2012
  • Purpose: This study was designed to help to provide the criteria of the esthetic smile in oromaxillary region on twenties, fifties and sixties. Materials and methods: The facial straight photographs of 33 adults (male 15, female 18, mean age 27.2 years old) and 20 seniors (male 7, female 13, mean age 55.6 years old) in resting and smile position were taken. The measurements and proportion of lip-teeth relation during smile were statistically analyzed, and survey of freshmen and seniors who belong to School of Dentistry, Chonnam National University were taken to select the best esthetic smile among the photographs. Results: In the relationship between the upper lip and the teeth, average smile was the most frequent, and mean of smile line ratio was 1.090 in young group and 0.90 in old group. The correlation between the buccal corridor ratio and exposed teeth count was inversed. At smile, most frequently exposed tooth was the second premolar (63.64%) in young gourp and the first premolar (35.00%) in old group. The correlation between the upper lip change ratio and exposed clinical crown length of maxillary central incisor was inverse, but there was no correlation between the lower lip change ratio and exposed clinical crown length of maxillarycentral incisor. Conclusion: In the result of survey, the students selected the case exposed to the first premolar as the most esthetic smile. The most esthetic smile between full facial photograph and the lip only photograph by the freshmen was different, but that by seniors was identical.

Implant-supported fixed prosthetic restoration using a high performance polymer (PEKK) in a mandibular unilateral resection: A case report (하악골 편측 절제 환자에서 High Performance Polymer (PEKK)를 이용한 임플란트 지지형 고정성 보철 수복 증례)

  • Kong, Dae-Ryong;Min, Gyeong-Won;Jang, Ki-Yeol;Lee, Gyeong-Je;Lee, Sun-Haeng
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.60 no.3
    • /
    • pp.254-262
    • /
    • 2022
  • When treating partial edentulous patients, it is important to use an appropriate restorative materials. Inappropriate restorative materials can adversely affect the outcome of prosthetic restorations. Zirconia and dental metal, which are currently and widely used materials, have a higher elastic modulus than cortical bone, so when an external force is generated, a harmful force can be applied to the implant and the bone around the implant. Polyetherketoneketone (PEKK), a recently introduced material, has a elastic modulus similar to that of cortical bone, and has many advantages in terms of physical properties and biocompatibility. This case report describes that implant-supported fixed prosthetic treatment using PEKK was performed, and functional and esthetic satisfactory results were obtained.

A case of oral rehabilitation in a patient with severe tooth wear and occlusal plane collapse, utilizing maxillary fixed prosthesis and mandibular implant-assisted removable partial denture (과도한 치아 마모와 교합평면 붕괴를 보이는 환자에서 상악 고정성 보철 및 하악 임플란트 보조 국소의치를 통한 구강회복 증례)

  • Jae-Hyung Ahn;Sung-Yong Kim;Seong-A Kim;Yong-Sang Lee;Keun-Woo Lee;Hee-Won Jang
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.62 no.2
    • /
    • pp.174-182
    • /
    • 2024
  • In patients with multiple missing molars, wear patterns or displacement of anterior teeth, collapsed occlusal plane, and reduction in vertical dimension may occur. Particularly, in case of a few remaining teeth on one side, a removable partial denture has biomechanical disadvantage. For this reason, an implant-assisted removable partial denture with a few implant surveyed crowns can be an alternative. In this case, due to the right mandibular posterior teeth loss, the anterior teeth were severely worn and the occlusal plane was collapsed. With minimal increasing vertical dimension, oral rehabilitation was performed using a maxillary fixed prosthesis and mandibular implant-assisted removable partial denture. As a result, functional and aesthetic clinical outcomes were obtained.