• Title/Summary/Keyword: 심근관류 SPECT

Search Result 127, Processing Time 0.026 seconds

Prognostic Implication of Normal Myocardial Perfusion Scintigraphy in Patients with Chest Pain (정상 심근관류신티그라피 소견을 보인 흉통환자의 예후)

  • Song, Ho-Cheon;Min, Jung-Jun;Kim, Ji-Yeul;Bom, Hee-Seung
    • The Korean Journal of Nuclear Medicine
    • /
    • v.31 no.1
    • /
    • pp.67-72
    • /
    • 1997
  • Myocardial scintigraphy is a widely used noninvasive procedure with high sensitivity for the detection of patients with suspected coronary artery disease. The purpose of this study was to determine the prognostic value of a normal myocardial scintigraphy in 292 patients (150 males, 142 females, mean age $53{\pm}12$ years) with chest pain who were followed from 7 to 58 (mean 25) months. Myocardial SPECT was performed with Tc-99m MIBI in 173 patients, with Tc-99m tetrofosmin in 74 patients and with T1-201 in 45 patients. During the follow-up period, there were 2 cardiac deaths and 2 nonfatal myocardial infarctions resulting in cardiac event rate of 1.37% (0.66% Per Year). The cardiac event rate was not different in patients with angiographically normal coronary arteries (1/30, 3.3%) and in those who had significant coronary artery disease (2/27, 7.4%) (p=0.60). In conclusion, patients with chest pain and normal myocardial scintigraphy have a low cardiac event rate, and there was no significant difference of. cardiac event rates between patients with normal and abnormal coronary angiograms.

  • PDF

Influence of Gating and Attenuation-correction for Diagnostic Performance of Usual Rest/stress Myocardial Perfusion SPECT in Coronary Artery Disease (게이트 방법과 감쇠보정이 심근 관류 SPECT의 관상동맥질환 진단 성능에 미치는 영향)

  • Lee, Dong-Soo;Yeo, Jeong-Seok;So, Young;Cheon, Gi-Jeong;Kim, Kyeong-Min;Chung, June-Key;Lee, Myung-Chul
    • The Korean Journal of Nuclear Medicine
    • /
    • v.33 no.2
    • /
    • pp.131-142
    • /
    • 1999
  • Purpose: Either gated myocardial perfusion SPECT or attenuation corrected SPECT can be used to improve specificity in the diagnosis of coronary artery disease. We investigated in this study whether gating or attenuation correction improved diagnostic performance of rest/stress perfusion SPECT in patients having intermediate pre-test likelihood of coronary artery disease. Materials and Methods: Sixty-eight patients underwent rest attenuation-corrected T1-20l/dipyridamole stress gated attenuation-corrected Tc-99m -MIBI SPECT using an ADAC vertex camera (M:F=29:39, aged $59{\pm}12$ years, coronary artery stenosis ${\geq}70%$, one vessel: 13, two vessel: 18, three vessel: 8, normal: 29). Using a five-point scale, three physicians graded the post-test likelihood of coronary artery disease for each arterial territory (1:normal, 2: possibly normal, 3:equivocal, 4. possibly abnormal, 5: abnormal). Sensitivity, specificity and area under receiver-operating-characteristic curves were compared for each operator between three methods : (A) non-attenuation-corrected SPECT; (B) gated SPECT added to (A): and (C) attenuation-corrected SPECT added to (B). Results: When grade 3 was used as the criteria for coronary artery disease, no differences in sensitivity and specificity were found between the three methods for each operator. Areas under receiver-operating-characteristic curves for diagnosis of coronary artery disease revealed no differences between each modality (p>0.05). Conclusion: In patients at intermediate risk of coronary artery disease, gated SPECT and attenuation- corrected SPECT did not improve diagnostic performance.

  • PDF

Reproducibility of Gated Myocardial Perfusion SPECT for the Assessment of Myocardial Function: Comparison with Thallium-201 and Technetium-99m-MIBI (심근 기능 측정에 사용된 게이트 심근 관류 SPECT 방법의 재현성 평가: $^{201}Tl$$^{99m}Tc$-MIBI 게이트 SPECT의 비교)

  • Hyun, In-Young;Seo, Jeong-Kee;Hong, Eui-Soo;Kim, Dae-Hyuk;Kim, Sung-Eun;Kwan, Jun;Park, Keum-Soo;Choe, Won-Sick;Lee, Woo-Hyung
    • The Korean Journal of Nuclear Medicine
    • /
    • v.34 no.5
    • /
    • pp.381-392
    • /
    • 2000
  • Purpose: We compared the reproducibility of $^{201}Tl\;and\;^{99m}Tc$-sestamibi (MIBI) gated SPECT measurement of myocardial function using the Germano algorithm Materials and Methods: Gated SPECT acquisition was repeated in the same position in 30 patients who received $^{201}Tl$ and in 26 who received $^{99m}Tc$-MIBI. The quantification of end-diastolic volume (EDV), end-systolic volume (ESV), and ejection fraction (EF) on $^{201}Tl\;and\;^{99m}Tc$-MIBI gated SPECT was processed independently using Cedars quantitative gated SPECT software. The reproducibility of the assessment of myocardial function on $^{201}Tl$ gated SPECT was compared with that of $^{99m}Tc$-MIBI gated SPECT Results: Correlation between the two measurements for volumes and EF was excellent by the repeated gated SPECT studies of $^{201}Tl$ (r=0.928 to 0.986; p<0.05) and $^{99m}Tc$-MIBI (r=0.979 to 0.997; p<0.05). However, Bland Altman analysis revealed the 95% limits of agreement (2 SD) for volumes and EF were tighter by repeated $^{99m}Tc$-MIBI gated SPECT (EDV: 14.1 ml, ESV: 9.4 ml and EF: 5.5%) than by repeated $^{201}Tl$ gated SPECT (EDV: 24.1 ml, ESV: 18.6 ml and EF: 10.3%). The root mean square (RMS) values of the coefficient of variation (CV) for volumes und EFs were smaller by repeated $^{99m}Tc$-MIBI gated SPECT (EDV: 2.1 ml, ESV 2.7 ml and EF: 2.3%) than by repeated $^{201}Tl$ gated SPECT (EDV: 3.2 ml, ESV: 3.5 ml and EF: 5.2%). Conclusion: $^{99m}Tc$-MIBI provides more reproducible volumes and EF than $^{201}Tl$ on repeated acquisition gated SPECT. $^{99m}Tc$-MIBI gated SPECT is the preferable method for the clinical monitoring of myocardial function.

  • PDF

Stress/Rest Tc-99m-MIBI SPECT in Comparison with Rest/Stress Rubidium-82 PET (휴식/부하 심근 Rubidium-82 양전자단층촬영과 부하/휴식 심근 Tc-99m-MIBI 단일광자단층촬영의 비교)

  • Lee, D.S.;Kang, K.W.;Lee, K.H.;Jeong, J.M.;Kwark, C.;Chung, J.K.;Lee, M.C.;Seo, J.D.;Koh, C.S.
    • The Korean Journal of Nuclear Medicine
    • /
    • v.29 no.1
    • /
    • pp.31-40
    • /
    • 1995
  • We compared stress/rest myocardial Tc-99m-MIBl tomographic image findings with rest/stress rubidium-82 tomographic images. In 23 patients with coronary artery disease (12 of them received bypass grafts before) and 6 normal subjects, rest rubidium PET study was performed : rubidium-82 and Tc-99m-MIBI were injected simultaneously to each patient after dipyridamole stress for rubidium PET and MIBI SPECT; and rest MIBI SPECT was performed 4 hours thereafter. We scored segmental decrease of rubidium or MIBI uptakes into 5 grades for 29 segments from 3 short-axis, vertical and horizontal slices. Scores were summed for each major arterial territory. When more score than two grade-2's or one grade-3 was considered as the cue for significant stenosis for major arterial territories, 67% of 46 stenosed arteries were found with MIBI studies and 78% of them by rubidium studies. Fourteen among 28 grafted arterial territories of 12 post-CABG patients were found normal with both rubidium and MIBI. Segmental scores were concordant between rubidium and MIBI in 72% of 709 stress segments and in 80% of 825 rest segments. Stress rubidium segmental scores were less than stress MIBI scores in 9%, so were rest rubidium scores. Stress rubidium scores were more than stress MIBI scores in 20% of segments, and rest rubidium segmental scores were more than rest MIBl scores in 11%. Rank correlations (Spearman's rho's more than 0.7(stress) and 0.5(rest), slopes (MIBI/rubidium) around 0.7(stress) and 0.9 (rest)) suggested deeper and wider defects in stress with rubidium. Slope over 1 (MIBI/rubidium) with LAD segemental scores at rest and 7 territories which had much larger score with MIBI revealed exaggeration of rest defects with rest MIBI in same-day stress/rest study. Difference scores (stress-rest for each territory) suggesting Ischemia were larger with rubidium (slope of MIBI/rubidium around 0.45). As has been implied by animal or separate-day-human studies, these segmental analyses with simultaneous examination in patients told that rubidium PET flow studies disclose ischemia more often than MIBI studies and that rest MIBI studies in same-day stress/rest-sequence gave a little larger rest defect than they would have shown.

  • PDF

The Usefulness Assessment of Attenuation Correction and Location Information in SPECT/CT (SPECT/CT에서 감쇠 보정 및 위치 정보의 유용성 평가)

  • Choi, Jong-Sook;Jung, Woo-Young;Shin, Sang-Ki;Cho, Shee-Man
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.12 no.3
    • /
    • pp.214-221
    • /
    • 2008
  • Purpose: We make a qualitative analysis of whether Fusion SPECT/CT can find lesion's anatomical sites better than existing SPECT or not, and we want to show the usefulness of SPECT/CT through finding out effects of CT attenuation correction on SPECT images. Materials and Method: 1. The evaluation of fusion images: This study comprised patients who was tested $^{131}I$-MIBG, Bone, $^{111}In$-Octreotide, Meckel's diverticulum, Parathyroid MIBI with Precedence 16 or Symbia T2 from 2008 Jan to Aug. We compared SPECT/CT image with non fusion image and make a qualitative analysis. 2. The evaluation of attenuation correction: We classified 38 patients who was tested 201Tl myocardial exam with Symbia T2 into 5 sections by using Cedars Sinai' QPS program - Ant, Inf, Lat, Septum, Apex. And we showed each section's perfusion states by percentage. We compared the each section's perfusion-states differences between CT AC and Non AC by average${\pm}$standard deviation. Results: 1. The evaluation of fusion images : In high energy $^{131}I$ cases, it was hard to grasp exact anatomical lesions due to difference between regions and surrounding lesions' uptake level. After combining with CT, we could grabs anatomical lesion more exactly. And in meckel's diverticulum case or to find lesions around bowels or organs with $^{111}In$ cases, it demonstrates its superiority. Bone SPECT/CT images help to distinguish between disk spaces certainly and give correct results. 2. The evaluation of attenuation correction: There is no significant difference statistically in Ant and Lat (p>0.05), but there is a meaningful difference in Inferior, Apex and Septum (p<0.05). AC perfusion at inferior wall in the 5 sections of myocardium: The perfusion difference between Non AC perfusion image ($68.58{\pm}7.55$) and CT corrected perfusion image ($76.84{\pm}6.52$) was the largest by $8.26{\pm}4.95$ (p<0.01, t=10.29). Conclusion: Nuclear medicine physicians can identify not only molecular image which shows functional activity of lesions but also anatomical location information of lesions with more accuracy using the combination of SPECT and CT systems. Of course this combination helps nuclear medicine physician find out the abnormal parts. Moreover combined data sets help separate between normal group and abnormal group in complicated body part. So clinicians can carry out diagnosis and treatment planning at the same time with a single test image. In addition, when we examine a myocardium in thorax where attenuation can occur easily, we can trust perfusion more in a certain region in SPECT test because CT provides the capability for accurate attenuation correction. In these reasons, we think we can prove the justice after treatment fusion image.

  • PDF

Artifactual Perfusion Defects due to the Parameters of Reconstruction Filter in Tc-99m-MIBI Myocardial SPECT Images (Tc-99m-MIBI 심근 SPECT 영상에서 재구성 필터에 의한 인위적 관류결손에 관한 연구)

  • Kwark, Cheol-Eun;Lee, Kyung-Han;Lee, Dong-Soo;Park, Yong-Woo;Chung, June-Key;Lee, Myung-Chul;Seo, Joung-Don;Koh, Chang-Soon
    • The Korean Journal of Nuclear Medicine
    • /
    • v.29 no.1
    • /
    • pp.41-47
    • /
    • 1995
  • Tc-99m-MIBI(Sestamibi) myocardial SPECT along with T1-201 tomographic imaging has demonstrated wide application and high image qualify sufficient for the diagnosis of myocardial perfusion defect, which consequently reflects regional myocardial blood flow, The qualitative values of myocardial SPECT with Tc-99m-MIBI as well as the quantitative cases depend in some degree on the reconstruction techniques of multiple projections. Filtered backprojection(FBP) is the common standard for reconstruction rather than the complicated and time-consuming arithmetic methods. In FBP it Is known that the distribution of radioactivity in reconstructed transverse slices varies with the selected filter parameters such as cutoff frequencies and order(Butterworth case). The cutoff frequencies basically remove and decrease the true radioactive distribution and alter the pixel counts, which lead to underestimation of true counts in specific myocardial regions. In this study, we have investigated the effect of cutoff frequencies of reconstruction filter on the artifactually induced perfusion defects, which are often demonstrated near inferior and/or inferoseptal cardiac walls due to the intense hepatic uptake of Tc-99m-MIBI. A computerized method for identifying the relative degree of artifactual perfusion defect and for comparing those degrees along with the relative amount of hepatic uptake to myocardium was developed and patient images were studied to observe the quantitative degree of underestimation of myocardial perfusion, and to propose some reasonable thresh-old of cutoff frequency in the diagnosis of perfusion defect quantitatively. We concluded that from the quantitative viewpoint cutoff frequencies may be used as high as possible with the sacrifice of homogeneity of image quality, and those frequencies lower than the common 0.3 Nyquist frequency would reveal severe degradation of radio-active distribution near inferior and/or Inferoseptal myocardium when applying Butterworth or low pass filter.

  • PDF

Usefulness of Posture Change to Prevent Overlapping of Heart and Other Organs in Myocardial Perfusion SPECT using $^{99m}Tc$ Labeled Compound ($^{99m}Tc$ 표지화합물을 사용한 심근 관류 SPECT 검사에서 심장과 타 장기와의 중첩 방지를 위한 자세 변화의 유용성)

  • Lee, Dong-Hyuk;Oh, Shin-Hyun;Jeong, Seok;Jo, Seok-Won;NamKoong, Hyuk;Kim, Jae-Sam;Lee, Chang-Ho
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.16 no.1
    • /
    • pp.62-69
    • /
    • 2012
  • Purpose: The present study has an objective of effectively separating and making observations on a portion of radiopharmaceutical excreted via digestive organ to remain in the organ and invade a heart shadow. Materials and methods: When heart shadow is blocked by the organ in tests during a resting phase and a loaded phase, additional images were obtained using immobilization device. The immobilization devices were used to tilt the upper body forward from supine position. Results: In the reconstructed image for the separated case, as compared with the case where a part of organ is overlapped with heart, in terms of an overall mean value for each parameter, the end-diastolic volume increased by 2.75 mL, the end-systolic volume decreased by 3.16 mL, the left ventricle cardiac coefficient increased by 3.58%, and the area of defect region decreased by 3.58 and 3.92 cm for loading and resting phase, respectively. Conclusions: In the present study with myocardial perfusion SPECT, overlapped areas of heart and other organs could be effectively separated and visualization by the use of an immobilization device.

  • PDF

Accuracy of Ventricular Volume and Ejection Fraction Measured by Gated Tl-201 Perfusion Single Photon Emission Tomography (심전도 게이트 심근관류 Tl-201 SPECT로 측정된 좌심실 기능 및 좌심실 용적의 정확성)

  • Pai, Moon-Sun;Moon, Dae-Hyuk
    • The Korean Journal of Nuclear Medicine
    • /
    • v.39 no.2
    • /
    • pp.94-99
    • /
    • 2005
  • Electrocardiogram-gated single photon omission computed tomography (SPECT) provides valuable information in the assessment of both myocardial perfusion and ventricular function. Tl-201 is a suboptimal isotope for gating. Tl-201 images are more blurred compared with Tc-99m tracers due to the increased amount of scattered photons and use of a smooth filter. The average myocardial count densities are approximately one-half those of conventional technetium tracers. However, Tl-201 is still widely used because of its well-established utility for assessing myocardial perfusion, viability and risk stratification. Gated SPECT with Tl-201 enables us to assess both post-stress and rest left ventricular volume and function. Previous studies with gated Tl-201 SPECT measurements of ejection fraction (EF), end-diastolic volume (EDV), end-systolic volume (ESV) have shown high correlation with first-pass radionuclide angiography, gated blood pool scan, Tc-99m-MIBI gated SPECT, contrast ventriculography, echocardiography, and 3-dimensional magnetic resonance imaging. However, problems related to these studies include few agreement data of EDV and ESV, use of a reference method that is likely to have the same systemic errors (gated Tc-99m-MIBI SPECT), and other technical factors related to the count density of gated SPECT. With optimization of gated imaging protocols and more validation studies, gated Tl-201 SPECT would be an accurate method to provide perfusion and function information in patients with coronary artery disease.

Evaluation of Perfusion and Image Quality Changes by Reconstruction Methods in 13N-Ammonia Myocardial Perfusion PET/CT (13N-암모니아 심근관류 PET/CT 검사 시 영상 재구성 방법에 따른 관류량 변화와 영상 평가)

  • Do, Yong Ho;Lee, Hong Jae;Kim, Jin Eui
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.18 no.1
    • /
    • pp.69-75
    • /
    • 2014
  • Purpose: The aim of this study was to evaluate changes of quantitative and semi-quantitative myocardial perfusion indices and image quality by image reconstruction methods in $^{13}N$-ammonia ($^{13}N-NH_3$) myocardial perfusion PET/CT. Materials and Methods: Data of 14 (8 men, 6 women) patients underwent rest and adenosine stress $^{13}N-NH_3$ PET/CT (Biograph TruePoint 40 with TrueV, Siemens) were collected. Listmode scans were acquired for 10 minutes by injecting 370MBq of $^{13}N-NH_3$. Dynamic and static reconstruction was performed by use of FBP, iterative2D (2D), iterative3D (3D) and iterative TrueX (TrueX) algorithm. Coronary flow reserve (CFR) of dynamic reconstruction data, extent(%) and total perfusion deficit (TPD) (%) measured in sum of 4-10 minutes scan were evaluated by comparing with 2D method which was recommended by vendor. The image quality of each reconstructed data was compared and evaluated by five nuclear medicine physicians through a blind test. Results: CFR were lower in TrueX 18.68% (P=0.0002), FBP 4.35% (P=0.1243) and higher in 3D 7.91% (P<0.0001). As semi-quantitative values, extent and TPD of stress were higher in 3D 3.07%p (P=0.001), 2.36%p (P=0.0002), FBP 1.93%p (P=0.4275), 1.57%p (P=0.4595), TrueX 5.43%p (P=0.0003), 3.93%p (P<0.0001). Extent and TPD of rest were lower in FBP 0.86%p (P=0.1953), 0.57%p (P=0.2053) and higher in 3D 3.21%p (P=0.0006), 2.57%p (P=0.0001) and TrueX 5.36%p (P<0.0001), 4.36%p (P<0.0001). Based on the results of the blind test for image resolution and noise from the snapshot, 3D obtained the highest score, followed by 2D, TrueX and FBP. Conclusion: We found that quantitative and semi-quantitative myocardial perfusion values could be under- or over-estimated according to the reconstruction algorithm in $^{13}N-NH_3$ PET/CT. Therefore, proper dynamic and static reconstruction method should be established to provide accurate myocardial perfusion value.

  • PDF

Usefulness of Myocardial Perfusion SPECT after Percutaneous Coronary Intervention (PCI) (경피적 관상동맥 중재술(Percutanerous Coronary Intervention; PCI) 후 심근 관류 SPECT의 유용성)

  • Lee, Jong-Jin;Lee, Dong-Soo
    • The Korean Journal of Nuclear Medicine
    • /
    • v.39 no.2
    • /
    • pp.114-117
    • /
    • 2005
  • As the indication of percutaneous coronary intervention (PCI) has expanded to the more difficult and complicated cases, frequent restenosis is still expected after PCI. According to AHA/ACC guideline of the present time, routine use of myocardial perfusion single photon emission tomography (SPECT) is not recommended after coronary intervention, but symptom itself or exercise EKG is not enough for the detection of restensis or for the prediction of event-free survival. In high risk and/or symptomatic subjects, direct coronary angiography is required myocardial perfusion SPECT could detect restenosis in 79% of the patients if performed 2 to 9 months after PCI. Reversible perfusion decrease in the myocardial perfusion SPECT is known to be the major prognostic indicator of major adrerse cardiac event in PCI patients and also the prognosis is benign in the patients without reversible perfusion decrease. Though the cumulated specificity is 79% in the literature and optimal timing of myocardial perfusion SPECT is in controversy, SPECT is recommended even in asymptomatic patients at 3 to 9 months after PCI. Considering the evidences recently reported in the literature, myocardial perfusion SPECT is useful for risk stratification and detection of coronary artery restenosis requiring re-intervention in the asymptomatic patients after PCI.