• Title/Summary/Keyword: 실험 키트

Search Result 59, Processing Time 0.031 seconds

A Study of High Performance WebKit Mobile Web Browser (WebKit 모바일 웹 브라우저의 성능 향상을 위한 기법 연구)

  • Kim, Cheong-Ghil
    • Journal of Satellite, Information and Communications
    • /
    • v.7 no.1
    • /
    • pp.48-52
    • /
    • 2012
  • As the growing popularity of smartphones, mobile web browsing has become one of the most important and popular applications in mobile devices. Furthermore, it is clear that the demand for PC-like full browser performance on mobile devices is increasing greatly. WebKit is an open source web browser engine adopted by Google Android. This paper proposed a technique of increasing the performance of WebKit by paralleling its libraries. This method was applied to JPEG library and the performance evaluation was conducted in PC environment. The results was used to estimate the performance prediction on multi-core mobile embedded architecture and to show the feasibility of the proposed method to estimate the performance gain on heterogeneous multi-core embedded architecture.

Implementation of Multi Electronic Acupuncture based on Internet (인터넷 기반 멀티 전자침 구현)

  • Hong, You-Shik
    • The Journal of the Institute of Internet, Broadcasting and Communication
    • /
    • v.14 no.5
    • /
    • pp.197-202
    • /
    • 2014
  • It is used the important method that Oriental doctor determines patient's disease status observing patient's state of tongue in Oriental medicine clinic. In this paper, it developed the how to use the pulse diagnosis and tongue diagnosis based on s mart based electronic acupuncture. It will do objective judgment without wrong diagnosis. In this paper, we developed the algorithm that it automatically determines patient health condition and smart electronic acupuncture kit using fuzzy logic and fuzzy reasoning system were completed. In this paper, Simulation results proved that acupuncture is effective than the traditional method of using electronic intelligence.

Design of an Auto-Tuning IMC-PID Controller for a Heater System Using uDEAS (uDEAS를 이용한 히터 시스템의 IMC-PID 자동 동조 제어기 설계)

  • Kim, Man-Seok;Kim, Jo-Hwan;Choi, Min-Koo;Park, Jong-Oh;Kim, Jong-Wook
    • Journal of the Korean Institute of Intelligent Systems
    • /
    • v.21 no.4
    • /
    • pp.530-535
    • /
    • 2011
  • This paper deals with the precise temperature control of the heater used at a weaving thread or a drawn process. For precise temperature control, we suggest a design method that is auto-tuning IMC-PID controller using an optimization method uDEAS. For this method, we model the roll heater from the measurement data and we automatically tune the low pass filter value of IMC-PID controller that satisfies stability and conrol performance. Finally, we implement the designed controller using DSP kit.

중성자방사화분석을 이용한 사용후핵연료 중 요오드 정량

  • 김정석;박순달;이창헌;문종화;정용삼;김종구
    • Proceedings of the Korean Radioactive Waste Society Conference
    • /
    • 2005.06a
    • /
    • pp.432-432
    • /
    • 2005
  • 사용후핵연료시료 중에 함유된 요오드(I-127 및 129)를 정량하기 위하여 화학적 방법으로 분리 회수하고 중성자방사화분석법을 이용하였다. 사전실험으로 모의사용후핵연료를 이용하여 회수율을 측정하였다. 모의 및 실제사용후핵연료시료를 $90^{\circ}C$에서 8 M $HNO_3$ 용액으로 용해하고 용해 후 용해용액 중의 잔류 요오드, 응축 및 휘발된 요오드 각각을 정량하였다. 응축 요오드는 핵연료 용해 후 재증류하여 회수하였다. 잔류 및 응축 요오드는 시료의 산화상태를 조절한 후 용매추출로 요오드를 회수한 다음 이온교환 또는 침전법으로 방사화학적으로 분리한 후 중성자방사화분석(RNAA)으로 정량하였다. 제작한 이온교환분리관 및 여과키트에 요오드를 흡착 또는 침전시켜 분리한 다음 중성자조사를 위한 삽입체(Insert)로 이용하였다. 휘발 요오드는 제조한 흡착체(Ag-silica gel)를 담은 흡착관에 포집하고 홉착체를 구간별 균질시료로 만든 다음 비파괴중성자 방사화분석(INAA)으로 정량하였다. 침전 및 흡착 요오드의 화학적 특성을 EPMA(electron probe microanalysis) 분석으로 조사하였다. 요오드 정량결과를 다른 방법으로 비교분석하기 위하여 음이온교환수지상에서 요오드를 정제 및 회수하기 위한 용리거동을 조사하였다.

  • PDF

A Web-based Virtual Experiment Kit for Digital Logic Circuits Using Java Applets (자바 애플릿을 이용한 웹 기반 디지털 논리회로 가상실험키트)

  • Kim, Dong-Sik;Kim, Ki-Woon;Park, Sang-Yun;Seo, Sam-Jun
    • Proceedings of the KIEE Conference
    • /
    • 2003.07d
    • /
    • pp.2717-2719
    • /
    • 2003
  • In this paper, we developed an efficient virtual experiment kit with creative and interactive multimedia contents, which can be used to enhance the quality of education in the area of digital logic circuits. Since our virtual experiment kit is implemented to describe the on-campus laboratory, the learners can obtain similar experimental data through it. Also, our web-based virtual experiment kit is designed to enhance the efficiency of both the learners and the educators. The learners will be able to achieve high learning standard and the educators save time and labor. The virtual experiment is performed according to the following procedure: (1) Circuit Composition on the Bread Board (2) Applying Input Voltage (3) Output Measurements (4) Checkout of Experiment Results. Furthermore, the circuit composition on the bread board and its corresponding online schematic diagram are displayed together on the virtual experiment kit for the learner's convenience. Finally, we have obtained several affirmative effects such as reducing the total experimental hours and the damage rate for experimental equipments and increasing learning efficiencies as well as faculty productivity.

  • PDF

Development of computational thinking based Coding_Projects using the ARCS model (ARCS 모형을 적용한 컴퓨팅사고력 기반 코딩 프로젝트 개발)

  • Nam, Choong Mo;Kim, Chong Woo
    • Journal of The Korean Association of Information Education
    • /
    • v.23 no.4
    • /
    • pp.355-362
    • /
    • 2019
  • Elementary students are studying software training to teach coding education using text-based languages such as Python. In general, these higher-level languages support learning activities in combination with a kits for physical computing or various programming languages, in contrast to block-coding programming languages. In this study, we conducted a coding project based on computational thinking using the ARCS model to overcome the difficulties of text-based language. The results of the experiment show that students are generally confident and interested in programming. Especially, the understanding of repetition, function, and object was high in the change of computational thinking power, so this trend is believed to be due to the use of text-based languages and the Python module.

Investigation of the Molecular Diagnostic Market in Animals (동물 분자 진단 시장의 동향)

  • Park, Chang-Eun;Park, Sung-Ha
    • Korean Journal of Clinical Laboratory Science
    • /
    • v.51 no.1
    • /
    • pp.26-33
    • /
    • 2019
  • Recently, the rapid growth of the companion animal market has led to the development of animal disease diagnosis kits. Therefore, the utility of the introduction of biomarkers for the development of animal molecular diagnostics is being reevaluated. A good biomarker should be precise and reliable, distinguish between normal and diseased states, and differentiate between different diseases. Recently reported genetic markers, tumor markers (cell free DNA, circulating tumor cells, granzyme, and skin tumors), and others (brucellosis, programmed death recovery-1, symmetric dimethylarginine, periostin, and cysteinyl leukotrien) have been developed. The biomarkers are used for risk prediction or for the screening, diagnosis, and monitoring of disease progression. The most important criteria for related biomarkers are disease specificity. Many potential biomarkers have emerged from laboratory and test studies, but they have not been validated in independent or large-scale clinical studies. Candidate biomarkers evaluate disease associations, verify the effectiveness of biomarkers for early detection and disease progression, and incorporate them into humans and animals. In the future, it will be necessary to reevaluate the utility of well-structured biomarker-based research and study the development of kits that can be used in on-site tests in accordance with the trends introduced in the diagnosis of animal diseases.

Case Study on Robot Education for Children in Lower-Income Group (저소득층 아동을 위한 로봇교육 사례연구)

  • Lee, Sun-Woo;Park, Ill-Woo;Han, Jeong-Hye;Jo, Mi-Heon;Kim, Jin-Oh
    • 한국정보교육학회:학술대회논문집
    • /
    • 2010.08a
    • /
    • pp.9-13
    • /
    • 2010
  • Supported by the Ministry of Knowledge Economy, this research explored the potentiality of the use of hands-on robots in elementary school curriculum. On the basis of the analysis of prior research, we defined the meaning and the characteristics of hands-on robots. The priority was given to the development of lesson plans in attempting to activate the use of robots in elementary school curriculum. Also considering the difficulties faced in schools and the characteristics of robot-based instruction, we classified hands-on robots according to the shape and the goal of use.

  • PDF

Kit Preparation and Biodistribution of $Bz-MAG_3$ (benzoylmercaptoacetylglycylglycylglycine) for Renal Imaging (신장기능영상용 방사성의 약품 $Bz-MAG_3$(Benzoylmercaptoacetylglycylglycylglycine) 의 키트화 및 체내분포)

  • Kim, Young-Ju;Jeong, Jae-Min;Cho, Jung-Hyuk;Chang, Young-Soo;Lee, Dong-Soo;Chung, June-Key;Lee, Myung-Chul;Koh, Chang-Soon
    • The Korean Journal of Nuclear Medicine
    • /
    • v.30 no.3
    • /
    • pp.367-371
    • /
    • 1996
  • The $MAG_3$ is a tubular excreting radiopharmaceutical for renal image. We synthesized benzoyl $MAG_3\;(Bz-MAG_3)$ and made a kit for labeling with $^{99m}Tc$. We checked the labeling efficieny of $^{99m}Tc$ labeled $MAG_3$ and biodistribution. Labeling efficieny was checked by TLC-SG (acetonitrile/$H_2O$=2/1). After injecting of 1 mCi of $^{99m}Tc-MAG_3$ to ICR-mice, $T_{max}(min),\;T_{1/2}(min)$ were obtained in the renogram. Sequential images (30sec, 2min, 5min, 10min, 15min, 20min) of $^{99m}Tc-MAG_3$ were compared with those of commercial $^{99m}Tc$-DTPA (Du Pont Merck Pharmaceutical Co.) kit. 1) The $R_f$ value of synthesized $^{99m}Tc-MAG_3$ was 0.78 and labeling efficiency was $97.5{\pm}1.9%$ (n=10). 2) The dynamic images of the $^{99m}Tc-MAG_3$ were better than those of the $^{99m}Tc$-DTPA. 3) The $T_{max}(min.)$ and $T_{1/2}(min.)$ of $^{99m}Tc-MAG_3$ (n=10) were $1.5{\pm}0.5$ (left), $1.4{\pm}0.4$ (right), and $4.3{\pm}1.4$ (left), $4.8{\pm}2.0$ (right), respectively. The $T_{max}(min.)$ and $T_{1/2}(min.)$ of $^{99m}Tc$-DTPA (n=7) were $2.7{\pm}1.6$ (left), $2.7{\pm}1.6$ (right), and $3.8{\pm}1.7$ (left), $4.5{\pm}2.7$ (right), respectively. The quaility of image and labeling efficiency of the synthesized $Bz-MAG_3$ kit were excellent, that it was supposed to be used in routine clinical work.

  • PDF

Efficient Application of Westgard Multi-Rules and Quality Control Implementation Improvement (Westgard Multi-Rules의 효율적 적용과 조치사항의 개선)

  • Jung, Heung Soo;Oh, Youn Jung;Bae, Jin Soo;Baek, Jin Young;Hwang, Bo ra;Shin, Yong Hwan
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.21 no.1
    • /
    • pp.60-64
    • /
    • 2017
  • Purpose Westgard multi-rules application based on test quality improvement and commercialized international standard has been widely used in quality control. However, it is difficult to applicate the Westgard multi-rules in nuclear medicine in vitro tests due to the larger sample sizes and the simultaneous measurement of quality control material and patient sample. This study investigated the usefulness of Westgard multi-rules application in nuclear medicine in vitro tests. Materials and Methods A total of 282 systematic error multi-rules (22s, 101s) recorded in the samsung medical center computer system from January 2013 to June 2016 along with 117 cases of corrective measure record was analyzed. The Quality control implementation is recorded in Hospital information system were divided into 4 high-level areas including quality control material error, experimental procedural error, Kit lot number management error, and others. To prevent quality control material error, the existing method that each staff used their own method was changed. The staff who in charge of managing the quality control material was designated and daily consumption amount of every test was strictly controlled by one person. To prevent other errors, every test step was standardized so that the entire test procedures are identically implemented. Results The total quality control implementation was 117 cases; As a result, 62 quality control material errors were 62 cases, experimental process errors were 24 cases, Kit lot number control errors were 18 cases, and other errors were 13 cases. The quality control material error was corrected and could be used fresh materials within 2 days after thawing. The cases of systemic error were decreased to causes as quality control material error. The quality control materials were reduced above 10 vials to a monthly average. In addition, these errors of experimental processing and Kit lot number were improved by test standardization. Consequently, the cases of 101s and 22s in systematic error rules decreased at least 2 cases to a monthly average. Conclusion To confirm of systematic error through multi-rules application quickly, it is necessary to base on management of the QC material, target values and standard deviation. Moreover, in the event of a systematic error, it was found important to record measures based on test cause analysis. The experiment results are expected to contribute to internal quality control improvement and prompt and accurate result reporting through error recording and causal analysis based on Westgard multi-rules analysis.

  • PDF