• Title/Summary/Keyword: 실험 모드해석

Search Result 590, Processing Time 0.029 seconds

A Study on the Current Measurement Using Spun Fiber (Spun 광섬유를 이용한 전류 측정에 관한 연구)

  • Kwon, Won-Hyun;Jeon, Suk-Hee;Kim, Young-Soo;Kim, Yo-Hee;Park, Han-Kyu
    • Journal of the Korean Institute of Telematics and Electronics
    • /
    • v.25 no.10
    • /
    • pp.1158-1165
    • /
    • 1988
  • In this paper, the polarization properties of spun fiber due to intrinsic birefringence and magneto-optic effects are theoretically analyzed and experimented. The degree of polarization which indicates the intrinsic birefrigence is measured over 0.818, and the variation of output polarization angle with input polarization angle is measured within 9$^{\circ}$. Compared with single mode fiber, spun fiber is found to have very excellent polarization-maintaining property. Implemented current measurement system using spun fiber can linearly measure the magnetic field up to 20,000 A/m generated by solenoid.

  • PDF

Development and Evaluation of the piezoelectric transducer for the transit-time ultrasonic flowmeters (외접형 초음파 유량센서용 압전 트랜스듀서의 개발 및 평가)

  • Lee Young-Jin;Im Jong-In
    • Journal of the Institute of Electronics Engineers of Korea SC
    • /
    • v.43 no.4 s.310
    • /
    • pp.30-34
    • /
    • 2006
  • To enhance the performance of the piezoelectric transducer for the transit-time type ultrasonic sensors, we investigated and verified the effect of it's size and raw materials using FEM(Finite Element Method) technique. Radiation angle of $25^{\circ}$ could be realized through the control of the matching layer's shape and its raw materials. Based on the results, the flowmeter is fabricated and characterized in real application, which thereby proves good sensitivity of 10 times better than current commercial one.

A New Phase Shift Full Bridge Converter with Serially Connected Two Transformers (직렬 연결된 두 개의 트랜스포머를 갖는 새로운 위상 천이 풀 브릿지 컨버터)

  • 구관본;김태성;문건우;윤명중
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.7 no.5
    • /
    • pp.443-452
    • /
    • 2002
  • A new phase shift full bridge (PSFB) converter with serially connected two transformers for telecommunication equipments of several hundred watts is proposed. The main features of the proposed converter are a wide input voltage range, an easiness to meet the requirement for zero voltage switching (ZVS) condition at a light load, and a small output voltage ripple. Furthermore, the serially connected two transformers can replace both a main transformer and an output inductor since the two transformers act as not only a main transformer but an output inductor by turns. Therefore, there is no need to use an output inductor, then the proposed converter features high power density. A mode analysis, design equations through a large signal modeling, and experimental results are presented to verify the validity of the proposed converter.

AC/DC Converter Suitable for a Pulsed Mode Switching DC Power Supply (펄스모드 스위칭 직류전원 장치에 적합한 AC/DC 컨버터)

  • 문상호;강성관;노의철;김인동;김흥근;전태원
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.8 no.5
    • /
    • pp.389-396
    • /
    • 2003
  • This paper describes a novel ac/dc power converter suitable for frequent output short-circuit faults. The output dc power of the proposed converter can be disconnected from the load within several hundred microseconds at the instant of short-circuit fault. The rising time of the dc load voltage is as small as several hundred microseconds, and there Is no overshoot of the dc voltage because the dc output fillet capacitors stay at a undischarged state. The proposed converter has the characteristics of a simplified structure, reduced cost, weight, and volume compared to the conventional power supplies for frequent output short-circuit. Analysis, simulations, and experiments are carried out to investigate the operation and usefulness of the proposed scheme.

A New Diode Clamp Rectifier Flyback Converter with Low Voltage Stress (낮은 전압 스트레스를 갖는 새로운 다이오드 클램프 정류기 플라이백 컨버터)

  • Park Sang-Gab;Han Sang-Kyoo;Roh Chung-Wook;Hong Sung-Soo;SaKong Suk-Chin;Kim Jong-Sun;Choi Heung-Kyun;Cho Kwang-Seung
    • Proceedings of the KIPE Conference
    • /
    • 2006.06a
    • /
    • pp.360-362
    • /
    • 2006
  • 기존 플라이백 컨버터의 출력 정류 다이오드는 변압기 누설 인덕터와의 공진으로 소자의 전압 스트레스 부담이 크며 스너버의 부가가 필수적이다. 반면 제안된 다이오드 클램프 정류기를 채용한 플라이백 컨버터는 출력 다이오드가 출력전압의 절반 또는 출력전압으로 클램프 되어 전압 내압을 대폭 줄일 수 있고, 손실이 큰 스너버가 필요 없으며 저가형 및 고효율의 장점이 있다. 본 논문에서는 제안된 컨버터를 소개하고 동작원리 및 동작모드 해석과 시뮬레이션 및 실험을 통한 검증결과를 제시 한다.

  • PDF

Study on 4-degree-of-freedom Mathematical Model for Simulation of Wind Turbine System at Initial Design Stage (풍력발전기 초기단계 모사실험을 위한 4자유도 수학적 모형에 대한 연구)

  • Shin, Yun-Ho;Moon, Seok-Jun;Chung, Tae-Young
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.23 no.8
    • /
    • pp.681-689
    • /
    • 2013
  • The commercial tools to simulate the non-linear dynamic characteristics of wind turbine system are various but, the tool take much time to simulate the control algorithm and require many input variables. In this paper, the procedures to derive the simplified 4-degree-of-freedom mathematical model of a 2-MW wind turbine which could be used at the initial design stage of the controller are proposed based on RISO's suggested method. In this model, the 1st tower fore-after bending motion and 1st blade flapping motion are also considered in addition to the rotor-generator rotation motion in the 2-DOF model. The effectiveness of the 4-DOF model is examined comparing with the 2-DOF model and verification of the simplified model is accomplished through modal analysis for whole wind turbine system.

Theoretical modeling and analysis of thulium doped fluoride fiber amplifier at 1.47 $\mu\textrm{m}$ band amplification (툴륨이 첨가된 플루오르 계열의 광섬유 증폭기의 1.47$\mu\textrm{m}$ 증폭 대역에 대한 모델링과 분석에 대한 연구)

  • 이원재;민범기;박재형;박남규
    • Korean Journal of Optics and Photonics
    • /
    • v.11 no.3
    • /
    • pp.171-178
    • /
    • 2000
  • We present a numerical model which enables to analyze $1.47mu$m amplification band characteristics for thulium doped fluoride fiber amplifiers. We focused on upconversion pumping scheme, thus many transitions affecting $1.47mu$m band amplification was considered simultaneously. Backward propagating waves and transverse mode were also considered in the model. The parameters for modeling were then acquired using published experimental data and related theories such as Judd-Ofelt theory for radiative transition, empirical energy gap law for non-radiative transition, and McCumber relations for cross-sections. The simulation showed well-matched results with experiment and internal dynamics. amics.

  • PDF

Analytical and Experimental Study on Vibration Characteristics for Rectangular Tank Structure Filled with Fluid (사각헝 탱크 구조의 접수 진동 특성에 관한 연구)

  • 최수현;김극수;손성완
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.12 no.3
    • /
    • pp.195-203
    • /
    • 2002
  • In the engine room and the aft part areas of the ship, there exist so many tank structures contacting with fresh water or sea water or oil. If these structures exhibit excessive vibrations during the sea trials, it takes a lot of cost, time and effort to improve vibration situation because the reinforcement work requires emptying the fluid out of the tanks, additional welding and special painting. It is therefore very important to predict a precise vibration characteristics of the tank structures at the design stage, however it is not easy to estimate vibration characteristics of the structures because of difficulties for accurate evaluation of the added (or virtual) mass effect due to the fluid inside the tank. In this paper, numerical and experimental approaches have been performed to present same fundamental data necessary for anti-vibration design of tank structures contacting with fluid, by investigating vibration behaviors of rectangular tank structure for various water depths.

Propagation Characteristics of Picosecond Gaussian Pulses in Coplanar Waveguides using Time Domain Measurement (시간영역 측정을 이용한 CPW에서 가우시안 펄스 전송 특성)

  • 이승엽;신용섭
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.14 no.11
    • /
    • pp.1143-1148
    • /
    • 2003
  • The distortion of picosecond pulses caused by dispersion as it propagates along microstripline and CPW(Coplanar waveguide) is investigated and measured using time domain measurement. Especially, this study presents that the distortion of these lines is analyzed and compared considering the relation between the dispersion effect and cut-off frequency(f$\_$TE/) of fundamental TE mode for the substrate of line. To verify theoretical results, several samples of 50 $\Omega$ lines are fabricated on the two kind of substrates with the different values of f$\_$TE/. The propagation characteristics of picosecond Gaussian pulse on thess lines are simply measured using VNA(Vector Network Analyzer) with the time-domain analysis function.

Modeling and Control of Switched Mode Power Module (스위칭 모드 파워 모듈의 이산영역 모델링 및 제어)

  • Kwak, Jae-Hyuk;Lim, Joon-Hong
    • Proceedings of the KIEE Conference
    • /
    • 2000.07d
    • /
    • pp.2675-2677
    • /
    • 2000
  • 본 논문에서는 광대역 입력전압에 대응 할 수 있는 직류 변환 장치(DC-DC Converter)의 제어기의 모델링 및 제어 방법에 대해서 제안한다. 일반적으로 직류 변환 장치의 주된 목적은 입력되는 직류 전압에 대해서 출력전압을 지속적이고 안정적으로 유지해 주는 것이다. 따라서, 안정적인 출력 전압을 얻는 방법으로서 제어되지 않은 직류 변환 장치에 입력전압을 안정적으로 공급해주는 방법도 고려해 볼 수 있으나, 이릴 경우 입력전류의 변화나 입력 전압이 지속적으로 변하는 경우에 대처 하기 어렵다. 따라서, 이러한 문제점들을 해결하기 위해서 출력전압을 궤환 시키고 이 신호에 의해 직류 변환 장치를 제어하는 방법을 고려한다. 또한, 단순한 제어기를 사용할 경우 그 입력전압의 범위가 소자의 한계와 안정성으로 인하여 국한적으로 한정되므로, 이러한 문제를 해결하기 위해 다수의 컨버터를 연결하고 이것을 프로세서를 사용하여 제어하는 방법을 설계한다. 모델링된 직류 변환 장치는 불연속선형 시스템(Piecewise Linear System)으로 해석되어 질 수 있으며, 아울러 각기 다른 입력 범위에서 동작하는 컨버터들에 대해서도 모델링되어야 한다. 또한 일정 간격의 입력 범위내에서 서로 다른 컨버터들을 동작시켜 줄 수 있는 방법도 고려한다. MATLab을 이용하여 파워 컨버터의 성능을 입증하고, 아울러 실제 회로의 실험을 통하여 결과를 검증한다.

  • PDF