• Title/Summary/Keyword: 실험유역

Search Result 244, Processing Time 0.033 seconds

A Study on Field Experiment and Numerical Modeling for Efficiency Analysis of Selective Withdrawal in Imha Reservoir (임하호 선택취수 효과분석을 위한 현장실험 및 수치해석 연구)

  • Kim, Tae Won;Kim, Young Do;Yi, Yong-Kon
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.32 no.2B
    • /
    • pp.113-121
    • /
    • 2012
  • When a heavy rain brings flooding, a high turbid water is flowing into a reservoir. In this study, the effectiveness of the intake structures for the selective withdrawal from the various levels of a stratified reservoir was evaluated by the field experiments and the numerical modeling of the three-dimensional approaching flows. The temperature, the turbidity, and the velocity fields for the selective withdrawal were measured using both YSI6600EDS and YSI6600ADV, respectively. A threedimensional model, FLOW-3D, was used to predict the performance of the intake tower in Imha reservoir. The comparisons of the vertical velocity field showed a good agreement with the field measurements. The efficiency of the turbid-water elimination of the selective withdrawal method from low levels was higher up to 46% than that of the surface withdrawal. From the analysis of the numerical simulation, the efficiency of turbidity elimination increased by 10% for the selective withdrawal from middle levels, and by 30% from low levels. These results showed that the selective withdrawals from middle and low levels are more effective than the surface-water intake. The similar results were obtained by the one-dimensional model, SELECT, which is much more computationally time-efficient.

Analysis of Intercepted Discharge Considering the Change of Street Inlet Size (빗물받이 유입구 크기 변화에 따른 차집유량 분석)

  • Kim, Jung Soo;Ryu, Teak Hee;Rim, Chang Soo;Yoon, Sei Eui
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2015.05a
    • /
    • pp.375-375
    • /
    • 2015
  • 최근 도시화에 따른 도로구역의 증가는 도심지의 불투수면적의 확대 및 도로의 수로화를 야기하여 집중호우 발생 시 노면 및 저지대의 침수를 가중시키고 있으며, 이로 인한 인명피해 및 재산 피해는 점차 증가하는 추세이다. 이에 기후변화에 따른 강우량의 변화 및 국지성 집중호우 등을 고려하고 도심지 침수 방지 및 방재성능 강화를 위하여 과거에 간선 10년, 지선 5년에서 간선 30년, 지선 10년으로 관거의 설계빈도가 상향조정 되었다. 도심지의 도로 및 유역 유출량의 배수에 상당한 영향을 미치는 빗물받이 및 빗물받이 유입구는 도심지의 방재성능강화 목적에 맞는 설계가 이루어져야 하나 현재 국내의 빗물받이 설치기준은 하수도시설기준(2009, 환경부)에서 '빗물받이 크기별, 도로 차선별 적정 빗물받이 설치간격' 으로 설계빈도 5년을 반영하여 제시된 설치기준이므로 이에 대한 수정 및 개정이 필요한 실정이다. 이에 본 연구에서는 관거시설의 설계빈도 상향을 고려한 도로 빗물받이의 유입량 산정을 위해 빗물받이 유입구 크기별 유입량을 도로의 차선, 종경사, 측구 횡경사 및 설계빈도의 변화를 고려하여 도로에서의 유출량을 산정하였으며, Froude 상사법칙을 이용하여 수리실험모형을 제작하여 실험을 실시하였다. 빗물받이 제원은 현재 대부분의 국도에 설치되는 크기인 $40{\times}50cm$, $40{\times}100cm$$40{\times}150cm$를 축소 제작하였다. 측구의 유량은 도로의 차선(2~4차선), 경사(도로 종경사 2~10%, 측구 횡경사 2~10%) 및 설계빈도(최대 30년)을 고려하였다. 실험 결과 측구의 횡경사가 커질수록 빗물받이로 유입되는 유량은 증가하였으며, 빗물받이 유입부의 길이가 증가함에 따라 유입부 측면부를 통한 횡유입량을 증가시켜 빗물받이 유입부의 차집율을 증가시켰다. 또한, 도로의 조건 변화 및 유입량의 변화에 따라서 흐름폭이 감소할수록 차집율이 증가하였다. 수리실험결과를 토대로 도로의 조건변화(차선, 도로 종경사, 측구 횡경사) 및 설계빈도 변화를 고려한 빗물받이의 차집율을 제시하였고 이를 회귀분석 하여 빗물받이 유입구 크기별 유입량 산정식을 도출하였다. 이는 설계빈도 상향에 따른 국내 빗물받이 유입부의 설계 기준 제시에 기초자료로 활용이 가능할 것으로 판단된다.

  • PDF

Effectiveness of Settling Treatment System to Reduce Urban Nonpoint Source Pollutant Load by First Flush (초기 강우에 의한 도시 유역 비점오염 부하의 유입 저감을 위한 침강 처리 시설 적용 타당성 분석)

  • Kim, Jaeyoung;Seo, Dongil;Lee, Tongeun
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.39 no.3
    • /
    • pp.140-148
    • /
    • 2017
  • The effectiveness of the first flush treatment system using settling process was evaluated to reduce urban nonpoint source pollutant loads to surface water during storm events. A pilot scale system was constructed and tested in the field and surface runoff samples were collected automatically according to pre-defined conditions. Nine rainfall events were tested and average removal efficiencies of TSS (Total Suspended Solid), TP (Total Phosphorus) and TN (Total Nitrogen) were evaluated as 87.4%, 75.3%, and 43.6%, respectively. Concentration and removal efficiency of pollutants were found to be affected by an amount of rainfall and rainfall intensities of the respective events. This seemed to be caused by the greater particulate fractions of first flushed samples than the samples collected in later time periods during the same rainfall events. The study showed that it is possible to remove a significant portion of the nonpoint source pollutant loads in initial rainfall runoff by using a simple settling process for TSS and TP without requiring additional power or chemicals.

Study on Precipitation of the Minerals in the Soil of Imha Reservoir Watershed (임하호 유역 토양의 광물학적 침전성 연구)

  • Kim, Yeonjeong;You, Samhwan;Jeong, Hyungjin;Baek, Seungcheol;Lee, Sungmin;Seo, Eulwon
    • Journal of the Korean GEO-environmental Society
    • /
    • v.11 no.4
    • /
    • pp.13-18
    • /
    • 2010
  • The present study was undertaken to investigate the characteristic of suspended matter in soils of Imha-Dam area by turbidity. Soil sampling was conducted at 5 points of Yeongyang (Turbid area) and 2 points of Cheongsong (Clean area). Experimental analysis was conducted using those samples. The pH of water in the soils at turbid area was higher than that of clean area. X-ray diffraction analysis showed that every sample consists in mainly quartz, illite and feldspar before precipitation. After precipitation for 3 days, the content of quartz and feldspar was decreased and the content of illite was increased at turbid area. The soil of Sinheung (St. 6) at clean area was analyzed only illite. SEM-EDS analysis showed the much content of $SiO_2$ as to every sample before precipitation, but $K_2O$, MgO, $Al_2O_3$, CaO and $Fe2O_3$ with illite was increased after precipitation for 3 days as to every sample. Experimental results exhibited that the major mineral of turbid water was illite at turbid area and clean area.

Measurement of the Flow Field in a River (LSPIV에 의한 하천 표면유속장의 관측)

  • Kim, Young-Sung;Yang, Jae-Rheen
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2009.05a
    • /
    • pp.1812-1816
    • /
    • 2009
  • 이미지 해석에 의한 유속장 측정방법은 유체역학분야에서 지난 30 여년 동안 많이 활용되어온 속도측정 기법으로 오늘날에는 이를 수공학 분야에서 이를 유량측정 등 수리현상 해석에 활용하려는 시도가 다각적으로 이루어지고 있다. 이에 본 연구에서는 이미지 해석에 의한 유속장 측정방법을 용담댐 시험유역에 적용하여 그의 자연하천에서의 적용성을 검토하고자 한다. 이미지 해석에 의한 유속장 측정방법은 PIV(Particle Image Velocimetry)로 통칭되고 있으며, PIV는 seeding, illumination, recording, 및 image processing의 네 가지 요소로 구성된다. seeding을 위해서 유체를 따라 흐를수 있는 작은 입자를 유체에 첨가한다. 유체를 따라 흐르는 입자들의 선명한 이미지를 얻기 위해서illumination이 필요하다. PIV를 이용하여 흐름을 해석하기 위한 illumination은 일반적으로 이중펄스 레이저가 이용된다. 이렇게 유속장 해석을 하려는 유체에 대하여 seeding 및 illumination이 준비되면 단일노출- 다중 프레임법, 혹은 다중노출-단일 프레임법으로 흐름을 recording을 한다. image processing은 이미지를 다운로드하고, 디지타이징 및 화질향상을 하는 전처리(pre-processing), 상관계수의 산정에 의한 유속 벡터의 결정 및 에러 벡터를 제거하고 유속장을 그래프화하는 후처리(post-processing) 과정으로 구성된다. LSPIV(Large Scale PIV)는 PIV의 기본원리를 근거로 하여 기존의 PIV에 비하여 실험실 내에서의 수리모형실험이나 일반 하천에서의 유속측정과 같은 큰 규모$(4m^2\sim45,000m^2$)의 흐름해석을 할 수 있도록 Fujita et al.(1994)와 Aya et al.(1995)이 확장시킨 것이다. PIV와 비교시 LSPIV의 다른 점은 넓은 흐름 표면적을 포함하기 위하여 촬영시에 카메라의 광축과 흐름 사이의 각도가 PIV에서 이용하는 수직이 아닌 경사각을 이용하였고 이에 따라 발생하는 이미지의 왜곡을 제거하기 위하여 이미지 변환기법을 적용하여 왜곡이 없는 정사촬영 이미지로 변환시킨다. 이후부터는 PIV의 이미지 처리 방법이 적용되어 표면유속을 산정한다. 다만 이미지 변환을 PIV 이미지 처리 전에 하느냐 후에 하느냐에 따라 유속장 해석결과에 차이가 있다. PIV의 네가지 단계를 포함하여 LSPIV의 각 단계를 구분하면, seeding, illumination, recording, image transformation,image processing 및 post-processing의 여섯 단계로 나뉘어진다 (Li, 2002). LSPIV를 적용시 물표면 입자의 Tracing을 위하여 자연하천에서 사용하기에 적합한 환경친화적인 seeding 재료인 Wood Mulch를 사용하여 유속을 측정하였다. 적용지점은 용담댐 상류의 동향수위관측소 지점으로 이 지점은 한국수자원공사의 수자원시험유역이 위치하고 있다. 이미지의 촬영은 가정용 비디오 캠코더 (Sony DCR-PC 350)을 이용하여 두 줄기의 흐름에 대하여 각각 약 5분 동안의 영상을 촬영한후 이중에서 seeding의 분포가 잘 이루어진 약 1분간을 추출한후 이를 이용하여 PIV 분석에 이용하였다. 대체적으로 유속장의 계산이 무난하게 이루어지었으나 비교적 수질 상태가 양호하고, 수심이 낮고, 하상재료가 자갈로 이루어져 있어 비슷한 색상의 seeding 재료를 추적하기 어려운 구간이 발생한 부분에서는 유속의 계산이 정확히 이루어지지 않았다.

  • PDF

Performance of Northern Exposure Index in Reducing Estimation Error for Daily Maximum Temperature over a Rugged Terrain (북향개방지수가 복잡지형의 일 최고기온 추정오차 저감에 미치는 영향)

  • Chung, U-Ran;Lee, Kwang-Hoe;Yun, Jin-I.
    • Korean Journal of Agricultural and Forest Meteorology
    • /
    • v.9 no.3
    • /
    • pp.195-202
    • /
    • 2007
  • The normalized difference in incident solar energy between a target surface and a level surface (overheating index, OHI) is useful in eliminating estimation error of site-specific maximum temperature in complex terrain. Due to the complexity in its calculation, however, an empirical proxy variable called northern exposure index (NEI) which combines slope and aspect has been used to estimate OHI based on empirical relationships between the two. An experiment with real-world landscape and temperature data was carried out to evaluate performance of the NEI - derived OHI (N-OHI) in reduction of spatial interpolation error for daily maximum temperature compared with that by the original OHI. We collected daily maximum temperature data from 7 sites in a mountainous watershed with a $149 km^2$ area and a 795m elevation range ($651{\sim}1,445m$) in Pyongchang, Kangwon province. Northern exposure index was calculated for the entire 166,050 grid cells constituting the watershed based on a 30-m digital elevation model. Daily OHI was calculated for the same watershed ana regressed to the variation of NEI. The regression equations were used to estimate N-OHI for 15th of each month. Deviations in daily maximum temperature at 7 sites from those measured at the nearby synoptic station were calculated from June 2006 to February 2007 and regressed to the N-OHI. The same procedure was repeated with the original OHI values. The ratio sum of square errors contributable by the N-OHI were 0.46 (winter), 0.24 (fall), and 0.01 (summer), while those by the original OHI were 0.52, 0.37 and 0.15, respectively.

Analysis of Physicochemical Characteristics of Suspended Sediments Flowing into the Saemangeum Reservoir in the Summer (하절기 새만금호 유입유사의 물리화학적 특성 분석)

  • Oh, Kyoung-Hee;Chung, Se-Woong;Cho, Young-Cheol
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.37 no.2
    • /
    • pp.99-106
    • /
    • 2015
  • To estimate the effects of suspended sediments flowing into the Saemangeum Reservoir on the extent of contamination of the reservoir, the suspended sediments were collected with sediment traps, which were installed from the upstream of the Mankyung and Dongjin Rivers to estuary of the reservoir, respectively, and the sedimentation rates and the chemical characteristics of suspended sediments were analyzed. The sedimentation rates in the Mankyung and Dongjin Rivers were ranged from 0.01~5.06 and $0.01{\sim}8.75kg/m^2/day$, respectively. Those were higher to the upstream of rivers, and were mainly affected by flood events. The concentrations of organic matters were from 3.3 to 9.6 times higher than those in the stream sediments and were higher after flood season, indicating the contaminants come from the non-point sources on the basin. The concentrations of total nitrogen and total phosphorus in the suspended sediments showed the same trend with the organic matters. These results indicate that the suspended sediments from the basin of the Mankyung and Dongjin Rivers are highly contaminated and the countermeasures to manage the sources of contamination on the basin are required to maintain the water quality of the Saemangeum Reservoir.

Assessment of Depth-averaged Velocity Conversion Factors in a Natural River with Measured Velocities (자연하천의 유속측정에 의한 수심평균유속환산계수의 산정)

  • Kim, Young-Sung;Lee, Hyun-Seok;Yang, Jae-Rheen;Lee, Yo-Sang
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2010.05a
    • /
    • pp.1897-1901
    • /
    • 2010
  • 이동식 전자파표면유속계를 이용한 홍수유량의 산정을 위해서 임의의 유량측정지점에서 측정한 표면유속 값에 수심평균유속환산계수 0.85를 적용하여 그 지점의 평균유속을 계산하고 있다. 이로 인해 각 지점에서 흐름조건 및 기상학적으로 요인으로 인한 이 계수의 변동성을 고려하지 않은 상태로 유량을 산정하게 되어 각 흐름조건을 고려한 유량산정을 할 수 없는 실정이다. 이에 하천 현장에서 표면유속과 수심별유속의 실측 자료를 이용하여 흐름조건에 따른 표면유속과 평균유속의 관계를 파악하고자 하였다. 이를 위하여 용담 수자원시험유역의 동향지점에서 하천을 횡단하며 바닥에서 수표면까지 수심방향으로 0.05~0.10 m의 간격으로 프로펠러 유속계를 이용하여 정밀법으로 각 수심에서의 유속을 측정하였다. 정밀측정된 수심별 유속을 이용하여 평균유속을 산정하고 이를 수체 (water column)의 가장 최상층에서 측정한 유속을 표면유속으로 가정한후 이로부터 수심평균유속환산계수를 산정하여 흐름조건에 따른 계수의 변화를 조사하였다. 하천 현장에서 흐름조건의 변화에 따른 표면유속과 수심별유속의 정밀측정을 통한 이들 깊이별 유속의 변화여부를 용담수자원시험유역의 동향지점에서 현장조사를 실시하였다. 측정당시 풍속이 느려서 (1.5~3.1 m/s) 바람으로 인한 유속에 미치는 영향이 수심별 유속분포상으로는 거의 나타나지 않았다. 다만 양안에서 평균유속과 표면유속이 역전되는 현상이 발생되었는데 이는 벽면 마찰에 바닥마찰의 영향이 추가됨에 따른 것으로 판단된다. 수심별 유속측정 결과를 전체적으로 분석한 결과 환산계수가 0.632~1.352로 넓게 분포하고 있다. 환산계수가 1.0 이상인 경우는 양안에 인접한 두 지점인데, 이들 두 경우는 유속분포가 이론적인 유속분포와는 상반된 유속이 측정 - 표면유속이 수심평균유속보다 느림 - 되었다. 환산계수가 0.6~0.8 사이에서 형성된 경우는 표면유속이 평균유속보다 25~55% 정도 빠르게 나타나고 있다. 전제 측정결과를 검토해보면, 전반적으로 양안에 인접한 측선에서 표면유속이 평균유속보다 느려지는 현상이 나타나고 있다. 또한 유속이 1.0 m/s 이상인 경우에 0.677~0.790의 환산계수 값을 보이는데 이 경우 수심이 50 cm 이하여서 바닥마찰의 영향이 큰 것으로 판단된다. 다양한 흐름조건별 표면유속과 수심별유속의 측정을 할 수 있는 현장여건 - 유속, 수위 등의 동일흐름 조건에 대해서 -에 많은 부분이 제약되어 이의 정밀분석이 힘든 실정이다. 따라서 이러한 현장측정시의 제약성을 극복하기 위해서 여러 가지 흐름조건을 구현할 수 있는 정밀제어가 가능한 실내실험장치를 이용한 면밀한 분석이 필요하다.

  • PDF

A Study for Scour Formulas Reviewing in Small Stream Watershed (소하천유역에서 교량세굴 검토 시 적용 가능한 세굴산정공식 비교)

  • Lee, Sung-Hyun;Kim, Dae-Gon
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2012.05a
    • /
    • pp.521-521
    • /
    • 2012
  • 우리나라는 산악지역이 국토의 대부분을 차지하고 있어 전체유역을 놓고 볼 때 대하천이 차지하는 부분보다는 중소하천이 차지하는 부분이 상대적으로 크고, 교량의 길이가 짧은 소교량이 수적으로 많은 부분을 차지하고 있다. 그중에서도 특히 중소하천의 유량은 시간적으로 매우 빠르게 변화하며 유속 또한 급속히 빨라져 하상의 변형이 순식간에 일어나고 있다. 이와 같은 시간적, 공간적인 호우특성과 지형특성으로 인하여 중소하천에 위치한 교량은 특히 세굴에 매우 취약함을 보여주고 있다. 하천에 건설되는 교량의 수명이나 안정성에 세굴이 미치는 영향은 매우 크며, 특히 우리나라와 같이 홍수 시 단기간에 걸쳐 유량이 급증하는 경우 유속에 의한 교량 기초의 급격한 세굴은 예상치 못한 교량 붕괴 사고를 초래할 수 있다. 현재 국내 소하천에 설치된 교량은 약 3,470개소(지방도 기준)로 다양한 하부구조로 설계되어 있다. 이렇게 하천 내에 세워진 교량과 같은 횡단 구조물들은 그 크기에 상관없이 하천의 형태에 영향을 미치게 된다. 그중에서 교량 세굴은 하천 횡단구조물로 인하여 발생되는 가장 중요한 문제 중의 하나로써 교량 건설 시 교각에 영향을 주는 세굴을 예측하고 방어하기 위하여 다양한 방정식을 통하여 신설교량의 교각세굴을 예측한다. 하지만 대부분의 교량 세굴 공식들은 실험실에서의 실험 결과를 토대로 개발되었기 때문에 이들 공식들이 산정한 국소 세굴량이 얼마나 정확한지는 실제 현장 관측 자료와의 비교를 통해서만 검증할 수 있다. 세굴 공식들의 산정 결과를 현장 실측자료와 비교하는 연구는 그 동안 다양하게 시도되었으나, 통일된 결론에는 도달하지 못하고 있다. 본 연구에서는 기존의 세굴깊이 산정 시 일반적으로 사용되어지고 있는 세굴공식들 중 소하천 교량 규모에 적용 가능한 공식들을 선별하고, 각 세굴심 추정공식에 속한 변수별 특성분석을 위하여, 5가지의 독립변수를 설정하여 국부세굴의 현장 측정값과 예측공식의 비교결과에 대하여 불일치율을 비교분석하였다. 그 결과, 모든 공식들의 불일치율의 기하 평균이 1보다 큰 것을 보여주고 있다. 즉, 모든 공식들이 과대 추정의 의미로 정확성면에서 우수한 공식들은 불일치율의 기하 평균이 1에 가깝고 기하 표준편차가 작은 공식들이 나타났으며, 이런 점에서 Froehlich 공식, Inglis-Poona II, Blench-Inglis I, Breusers 공식 등의 기하평균이 1에 가장 근접한 결과를 나타내었다. 각 세굴공식 세굴심 산정결과의 불일치율을 각각 5가지의 변수별로 도시하여 분석하였으며, 그 결과로 소하천에 대하여 적용 가능한 공식과 소하천에 적용 시에는 과다추정의 우려가 있는 공식으로 분류되어 면밀한 검토가 필요할 것으로 판단된다.

  • PDF

Analysis of Organic Carbon Mass Balance in Daecheong Reservoir Using a Three-dimensional Numerical Model (3차원 수치 모델을 이용한 대청호 유기탄소 물질수지 해석)

  • Kim, Dong Min;An, In Kyung;Min, Kyug Seo;Chung, Se Woong
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2021.06a
    • /
    • pp.62-62
    • /
    • 2021
  • 산업 고도화로 인하여 복잡하고 다양한 유기물의 사용량이 증가하였으며, 공공수역 내 새로운 오염물질이 유입됨에 따라 생화학적 산소요구량(BOD) 중심의 수질평가에 한계를 나타내었다. 이후 난분해성 물질을 고려한 유기물관리 정책과 총량관리의 필요성이 제기되었고 국내 하천과 호소에서는 총 유기탄소(TOC)를 유기물 관리지표로 설정하였다. 그러나 부영양 하천과 호소에서 TOC는 외부 부하뿐만아니라 식물플랑크톤의 과잉성장에 의해 증가할 수 있는 항목이므로 TOC 관리정책 추진을 위해서는 유기물의 기원에 대한 파악이 필요하다. 특히, 국내 하천에서 나타나고 있는 난분해성 유기물 오염도의 증가 추세에 대응한 실효성 있는 유기물 오염관리 정책을 수립하기 위해서는 다양한 유기물의 근원을 정확하게 파악하는 것이 매우 중요하다. 본 연구의 목적은 금강 수계 최대 상수원인 대청호를 대상으로 3차원 수리-수질 모델을 적용하여 유기탄소 성분 별 유입과 유출, 내부생성 및 소멸량을 평가하고 저수지시스템에서의 유기탄소 물질수지를 해석하는 데 있다. 유기탄소 물질수지 해석을 위해 AEM3D 모델을 사용하였으며 2017년을 대상으로 입력자료를 구축한 후 보정을 수행하였고 2018년을 대상으로 모델을 검정하였다. 모델은 유기탄소를 입자성, 용존성, 그리고 난분해성과 생분해성으로 구분하여 모의하며 유기물질 성상별 실험결과를 이용하여 입력자료를 구축하였다. 유기탄소 물질수지 해석을 위해 4가지의 탄소성분과 조류 세포 내 탄소의 질량 변화율을 계산하였다. 이를 위해 외부 유입·유출부하율, 수체 내 생성(일차생산, 재부상, 퇴적물과 수체 간 확산) 및 소멸률(POC 및 조류 침강, DOC 무기화, 탈질)을 고려하였다. 모델은 2017년과 2018년의 물수지를 적절히 재현하였으며 저수지의 성층구조를 잘 재현해내면서 전반적인 수온, 수질을 적절하게 모의하였다. 연간 TOC 부하량 중 내부기원 부하량은 2017년 68.4 %, 2018년은 높은 강우량의 영향으로 55.0%로 산정되었다. 내부 소멸 기작 중 침전으로 인한 손실이 가장 높은 것으로 나타났으며, 2017년과 2018년 각각 31.3%, 29.0%로 나타났다. TOC의 공간분포는 Chl-a 농도 분포와 유사하게 나타났으며, 댐 설치로 형성된 정체수역은 유역의 유기물 순환에 많은 영향을 미치는 것으로 평가되었다. TOC 관리 정책 기초자료 확보를 위해서는 향후 유역-저수지 시스템을 연계한 유기물 물질순환 심층 연구가 필요하다.

  • PDF