• Title/Summary/Keyword: 실험실 가속 시험

Search Result 7, Processing Time 0.023 seconds

Changes in Insulation Performance of Organic Insulating Materials for Building Construction by Accelerated Durability Test Conditions (가속내구성 조건에 따른 건축용 유기계 단열재의 단열성능 변화)

  • Lim, Soon-Hyun;Lee, Gun-Cheol
    • Journal of the Korea Institute of Building Construction
    • /
    • v.16 no.6
    • /
    • pp.595-601
    • /
    • 2016
  • The insulation performance of the insulation currently used in building structures is reflected only during design based on initial performance and the reduction in heat insulation performance due to the degradation of long-term durability is not reflected. This study reviewed the degradation of heat insulation performance due to the durability degradation of insulating materials through the accelerated durability test. The study findings showed that the foamed polystyrene insulation bead method did not show performance degradation due to aging in the standard environmental condition and laboratory accelerated test condition but the performance is degraded in the freeze-thaw test condition. On the other hand, in the case of the extrusion method, the degradation of the heat insulation performance was less in the freeze-thaw test condition, but the rapid performance degradation was caused by the release of the internal gas at the beginning of aging. In addition, the hard polyurethane foam insulation showed better initial insulation performance than other insulation materials, but the performance was found to be degraded somewhat under laboratory accelerated test conditions and freeze-thaw test conditions.

결정질 실리콘 태양전지 모듈 규격평가와 가속평가, 그리고 표준화의 역사

  • Baek, Do-Hyeon
    • Electrical & Electronic Materials
    • /
    • v.27 no.10
    • /
    • pp.11-21
    • /
    • 2014
  • 1975년 이후로 태양전지 평가 실험실과 제조업체들이 직접적으로 많은 노력을 하여 태양전지 모듈에 대한 가속 스트레스 평가를 개발하고 평가하였다. 이 노력들은 이미 알려진 불량 메커니즘을 토대로 모듈 디자인의 민감한 취약 부분을 발견하기 위한 평가를 목적으로 평가 순서/방법 표준화에 많은 기여를 하였다. 이러한 평가 순서/방법은 국가와 국제 모듈 규격 표준화에 적용되었다. 그리고, 실제 외부에서 설치되어 한 번도 문제가 발생되지 않은 평가들은 중간에 제거 되기도 하였다. 가장 대표적인 예로 twist test는 모듈 설치 후 발생되는 불량에 대한 평가이지만, 실제로 불량은 한번도 발견되지 않았다. 덧붙여서, 표준 평가들은 많은 특화된 가속평가를 사용하게 되는데, 이는 문제점들을 조사하거나 특정 모듈 디자인에 대한 잠재적인 불량을 조사하기 위함이다. 실제 수명예측을 위한 가속평가는 가속 인자의 지식이 반드시 필요하지만, 태양전지 분야에서는 문헌이 많이 부족하다. 많은 연구자들이 85/85 DH 평가시간과 습한 지역에서 수년 간 사용된 모듈과의 상관관계를 만들기 위해 시도 하였다. 그리고 이 모델은 DH 평가 표준시간인 1,000시간으로 정의하는데 많은 영향을 미치기도 했다. 하지만, 이 모델은 단지 단일 모드 불량일 경우에만 적용이 되는 것이다. 다른 불량에 대한 가속인자들은 여전히 잘 알려져 있지 않다. 따라서, 모듈이 비록 표준 규격시험을 통과했다고 하더라도 제품이 특정 기간 동안 전력을 생산할 수 있다고 말할 수 없다. 또한, 이 표준평가가 모든 불량 메커니즘에 대한 평가가 되지 않기 때문에 제품의 수명을 결정하는데 사용될 수 없다.

  • PDF

Measurement and Analysis of Wind Response of InCheon Bridge (인천대교의 풍응답 계측 및 분석)

  • Kim, Saang-Bum;Im, Duk-Ki;Park, Hyun-Woo
    • Proceedings of the Computational Structural Engineering Institute Conference
    • /
    • 2011.04a
    • /
    • pp.340-343
    • /
    • 2011
  • 장대 케이블 교량의 풍응답을 계측할 수 있는 무선센서네트워크 기반의 풍응답 계측시스템을 개발하고, 이를 사용하여 인천대교의 시공단계별로 고유진동수, Mode Shape과 같은 Modal Parameters의 변화를 추정하고 보강형에서의 풍압분포와 보강형, 주탑, 케이블의 가속도를 계측하여 내풍 성능을 분석하였다. 개발된 계측 시스템은 인천대교 사장교의 전체 거동을 계측할 수 있도록, 1.5km 범위에 넓게 분포된 최대 55 Nodes에서 최대 1kHz의 동기화된 계측을 수행할 수 있으며, 각 Node별로 3축가속도나 풍압을 측정할 수 있다. 전체 Node에서 가속도를 계측하는 경우에는 최대 165 Channel을 1kHz로 측정할 수 있다. Modal 해석의 경우에, 고가교, 접속교, 사장교 주탑, 보강형, 케이블의 시공 단계별 동특성의 변화를 추정하였으며, 고가교에서는 모드해석을 통해 역추정한 구조계수를 정적재하실험 및 실험실에서의 Mold 시험결과와 비교하였으며 사장교 케이블에서는 케이블 댐퍼의 성능을 분석하였다. 또한 인천대교 보강형에서의 풍압분포를 계측하였으며, 풍압의 공간상관관계를 분석하였고, 풍하중 및 풍진동 특성을 분석하여 가속도 계측 결과와 비교하였다. 계측 및 분석 결과를 바탕으로 장대교량의 내풍성능을 확보하고 향상시키는데 활용할 수 있을 것으로 기대한다.

  • PDF

Construction of Measuring System for Magnetic Properties Measurement of Azimuth Angle Sensor (방위각센서의 자기특성 측정 장치 제작)

  • Son, Derac
    • Journal of the Korean Magnetics Society
    • /
    • v.24 no.1
    • /
    • pp.22-27
    • /
    • 2014
  • North indicating azimuth angle sensors have been used in airplanes, ships traditionally and nowadays employed in smart phones. For the azimuth and roll angle measurement of the sensor, 3-axis acceleration sensor was added to the 3-axis magnetic field sensor. In this work, we have constructed a measuring system for the measurement of the magnetic field and the angle uncertainty of the magnetic field sensors. Measuring system could be useful not only in non-magnetic laboratory but also in normal laboratory, we constructed small size of 3-axis Helmholtz coils for the compensation environment magnetic field (Earth magnetic field and magnetic field from building) and the generation of magnetic field for the test of magnetic field sensor. The constructed measuring system could compensate environment magnetic field below 10 nT level and generate 3-dimensional magnetic field with magnitude uncertainty of 0.2 % and angle error of $0.2^{\circ}$ within the volume of ${\pm}30mm$ diameter at center of Helmholtz coils. For the conformation of developed measuring system, We tested commercially available 3-axis magnetometer and heading sensor.

A Preliminary Study of Roller Types for Chip Seals Construction (Chip Seals 시공을 위한 롤러 종류에 따른 기초적인 연구)

  • Lee, Jae-Jun;Kim, R. Young-Soo
    • International Journal of Highway Engineering
    • /
    • v.12 no.3
    • /
    • pp.79-85
    • /
    • 2010
  • This paper presents a preliminary study of roller types for chip seals based on aggregate retention performance. Chip seal test sections composed of single seals of granite 78M aggregate and CRS-2 emulsion were constructed using three different roller types: the pneumatic tire roller, steel wheel roller, and combination roller. In order to investigate the performance of these rollers effectively, it is critical to test chip seal samples obtained directly from field construction. Therefore, test sections were constructed on New Sandy Hill Church Road near Bailey, North Carolina. Chip seal samples obtained from these sections were used for laboratory testing. The aggregate retention performance was evaluated using the flip-over test (FOT), Vialit test, and the third-scale Model Mobile Loading Simulator (MMLS3). Based on the test results and visual observation, both the pneumatic roller and the combination roller used together are recommended to improve chip seal performance with the sequence of the pneumatic roller rolling first followed by the combination roller.

Verification of the Viability of Equipotential Switching Direct Current Potential Drop Method for Piping Wall Loss Monitoring with Signal Sensitivity Analysis (등전위 교번식 직류전위차법의 신호 정밀도 검증을 통한 배관 감육 진단 기술에의 적용성 검증)

  • Ryu, Kyung-Ha;Hwang, Il-Soon;Kim, Ji-Hyun
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.28 no.2
    • /
    • pp.191-198
    • /
    • 2008
  • Flow accelerated corrosion (FAC) phenomenon of low alloy carbon steels in nuclear power plant has been known as one of major degradation mechanisms. It has a potential to cause nuclear pipe rupture accident which may directly impact on the plant reliability and safety. Recently, the equipotential switching direct current potential drop (ES-DCPD) method has been developed, by the present authors, as a method to monitor wall loss in a piping. This method can rapidly monitor the thinning of piping, utilizing either the wide range monitoring (WiRM) or the narrow range monitoring (NaRM) technique. WiRM is a method to monitor wide range of straight piping, whereas NaRM focuses significantly on a narrow range such as an elbow. WiRM and NaRM can improve the reliability of the current FAC screening method that is based on computer modeling on fluid flow conditions. In this paper, the measurements by ES-DCPD are performed with signal sensitivity analyses in the laboratory environment for extended period and showed the viability of ES-DCPD for real plant applications.

K-DEV: A Borehole Deviation Logging Probe Applicable to Steel-cased Holes (철재 케이싱이 설치된 시추공에서도 적용가능한 공곡검층기 K-DEV)

  • Yoonho, Song;Yeonguk, Jo;Seungdo, Kim;Tae Jong, Lee;Myungsun, Kim;In-Hwa, Park;Heuisoon, Lee
    • Geophysics and Geophysical Exploration
    • /
    • v.25 no.4
    • /
    • pp.167-176
    • /
    • 2022
  • We designed a borehole deviation survey tool applicable for steel-cased holes, K-DEV, and developed a prototype for a depth of 500 m aiming to development of own equipment required to secure deep subsurface characterization technologies. K-DEV is equipped with sensors that provide digital output with verified high performance; moreover, it is also compatible with logging winch systems used in Korea. The K-DEV prototype has a nonmagnetic stainless steel housing with an outer diameter of 48.3 mm, which has been tested in the laboratory for water resistance up to 20 MPa and for durability by running into a 1-km deep borehole. We confirmed the operational stability and data repeatability of the prototype by constantly logging up and down to the depth of 600 m. A high-precision micro-electro-mechanical system (MEMS) gyroscope was used for the K-DEV prototype as the gyro sensor, which is crucial for azimuth determination in cased holes. Additionally, we devised an accurate trajectory survey algorithm by employing Unscented Kalman filtering and data fusion for optimization. The borehole test with K-DEV and a commercial logging tool produced sufficiently similar results. Furthermore, the issue of error accumulation due to drift over time of the MEMS gyro was successfully overcome by compensating with stationary measurements for the same attitude at the wellhead before and after logging, as demonstrated by the nearly identical result to the open hole. We believe that the methodology of K-DEV development and operational stability, as well as the data reliability of the prototype, were confirmed through these test applications.