• Title/Summary/Keyword: 실측오차

Search Result 512, Processing Time 0.018 seconds

The effects of temperatures on the development of Oriental -tobacco budmoth, Heliothis assulta Guenee, and control effects of Thuricide $HP^{(R)}$- (고추담배나방의 생태 및 방제에 관한 연구 -온도가 담배나방의 생육에 미치는 영향 및 Thuricide $HP^{(R)}$의 방제 효과-)

  • Chung C. S.;Hyun J. S.
    • Korean journal of applied entomology
    • /
    • v.19 no.1 s.42
    • /
    • pp.57-65
    • /
    • 1980
  • The oriental tobacco budmoth, Heliothis assulta Guenee were reared under various temperatures; $20^{\circ}C,\;25^{\circ}C,\;30^{\circ}C$ and the control effects of Thuricide $HP^{(R)}$ were examined. The results obtained were as fellows: 1. The adult longevity of oriental tobacco budmoth was 11.35 days, and 3.00 days for preovipositional period, 4.75 days for ovipositional Period, and 3.50 days for postovipositional period. 2. The total number of eggs laid by a female were 307 at $20^{\circ}C$, 413 at $25^{\circ}C$ and 189 at $30^{\circ}C$. The number of eggs per female per day were 64.05 in average. 3. The average egg Periods were 7.71 days at $20^{\circ}C$, 4.12 days at $25^{\circ}C$ and 3.58 days at $30^{\circ}C$ and the hatchiabilities were $71.25\%,\;78.49\%\;and\;81.05\%$ at the respective incubation temperatures. 4. The larval developmental periods were 43.51 days at $20^{\circ}C$, 21.79 days at $25^{\circ}C$ and 18.05 days at $25^{\circ}C$ and the mortalities were $80.70\%,\;95.93\%$ and $87.01\%$ at the respective temperatures. 5. The pupal developmental periods were 24.22 days at $20^{\circ}C$, 12.36 days at $25^{\circ}C$ and 11.50 days at $30^{\circ}C$ and the mortalities at the respective temperatures were $18.18\%,\;42.11\%\;and\;40.00\%$. 6. The calculated threshold temperatures for the development were $11.61^{\circ}C$ for the eggs, $11.96^{\circ}C$ for the larvae, and $10.06^{\circ}C$ for the pupae. The estimated total effective temperatures were 60.41 day degrees for e eggs, 319.35 day degrees for the larvae, 222.66 day degrees for the pupae, and overall total effective temperatures, however, would be ranged 640-660 day degrees if the reproductive period of the adult was considered. 7. The relationship between the overall developmental periods and the rearing temperature could be Y=-4.272X+155.39 (r=0.9105), where Y; number of days required to complete the life cycle, X; treated temperatures. 8. The control effects of Thuricide $HP^{(R)}$ were $73.43\%$ for spray and $58.22\%$ for bait applications.

  • PDF

Effects of an Aspirated Radiation Shield on Temperature Measurement in a Greenhouse (강제 흡출식 복사선 차폐장치가 온실의 기온측정에 미치는 영향)

  • Jeong, Young Kyun;Lee, Jong Goo;Yun, Sung Wook;Kim, Hyeon Tae;Ahn, Enu Ki;Seo, Jae Seok;Yoon, Yong Cheol
    • Journal of Bio-Environment Control
    • /
    • v.28 no.1
    • /
    • pp.78-85
    • /
    • 2019
  • This study was designed to examine the performance of an aspirated radiation shield(ARS), which was made at the investigator's lab and characterized by relatively easier making and lower costs based on survey data and reports on errors in its measurements of temperature and relative humidity. The findings were summarized as follows: the ARS and the Jinju weather station made measurements and recorded the range of maximum, average, and minimum temperature at $2.0{\sim}34.1^{\circ}C$, $-6.1{\sim}22.2^{\circ}C$, $-14.0{\sim}15.1^{\circ}C$ and $0.4{\sim}31.5^{\circ}C$, $-5.8{\sim}22.0^{\circ}C$, $-14.1{\sim}16.3^{\circ}C$, respectively. There were no big differences in temperature measurements between the two institutions except that the lowest and highest point of maximum temperature was higher on the campus by $1.6^{\circ}C$ and $2.6^{\circ}C$, respectively. The measurements of ARS were tested against those of a standard thermometer. The results show that the temperature measured by ARS was lower by $-2.0^{\circ}C$ or higher by $1.8^{\circ}C$ than the temperature measured by a standard thermometer. The analysis results of its correlations with a standard thermometer reveal that the coefficient of determination was 0.99. Temperature was compared between fans and no fans, and the results show that maximum, average, and minimum temperature was higher overall with no fans by $0.5{\sim}7.6^{\circ}C$, $0.3{\sim}4.6^{\circ}C$ and $0.5{\sim}3.9^{\circ}C$, respectively. The daily average relative humidity measurements were compared between ARS and the weather station of Jinju, and the results show that the measurements of ARS were a little bit higher than those of the Jinju weather station. The measurements on June 27, July 26 and 29, and August 20 were relatively higher by 5.7%, 5.2%, 9.1%, and 5.8%, respectively, but differences in the monthly average between the two institutions were trivial at 2.0~3.0%. Relative humidity was in the range of -3.98~+7.78% overall based on measurements with ARS and Assman's psychometer. The study analyzed correlations in relative humidity between the measurements of the Jinju weather station and those of Assman's psychometer and found high correlations between them with the coefficient of determination at 0.94 and 0.97, respectively.