• 제목/요약/키워드: 실시간 하이브리드 실험법

검색결과 15건 처리시간 0.018초

실시간 하이브리드 실험법을 이용한 대형 MR감쇠기의 제진 성능평가 (Performance Evaluation of a Large-scale MR Damper for Controlling Seismic Responses Using a Real-time Hybrid Test Method)

  • 박은천;이성경;윤경조;정희산;이헌재;최강민;문석준;정형조;민경원
    • 한국소음진동공학회논문집
    • /
    • 제18권1호
    • /
    • pp.131-138
    • /
    • 2008
  • This paper presents real-time hybrid test method of large-scale MR damper applied to a building structure under seismic excitation. The real-time hybrid test using an actuator for the control performance evaluation of a MR damper controlling the response of earthquake-excited building structure is experimentally implemented. In the test, the building structure is used as a numerical part, on which a large-scale MR damper adopted as an experimental part was installed to reduce its response. At first, the force that is acting between a MR damper and building structure is measured from the load cell attached on the actuator system and is fed-back to the computer to control the motion of the actuator. Then, the actuator is so driven that the error between the interface displacement computed from the numerical building structure with the excitations of earthquake and the fed-back interface force and that measured from the actuator. The control efficiency of the MR damper used in this paper is experimentally confirmed by implementing this process of experiment on real-time.

강 뼈대 구조물의 단자유도 하이브리드 동적 실험 (Single Degree of Freedom Hybrid Dynamic Test with Steel Frame Structure)

  • 김세훈;나옥빈;김성일;이재진;강대흥
    • 한국철도학회논문집
    • /
    • 제15권4호
    • /
    • pp.413-421
    • /
    • 2012
  • 하이브리드 실험은 구조물의 거동을 수치해석 모델과 물리적 부분구조 모델로 나누어 동시에 수행되는 실험법으로써 본 논문에서는 지진하중에 의한 1경간 2층 강 뼈대 구조에 대한 하이브리드 시험을 수행하였다. 1층 기둥 1개소를 물리적 부분구조모형으로 선택하고, 한 개의 액추에이터를 이용해 수평방향으로 변위를 가하여 수치해석과 하이브리드 실험결과 사이의 거동추이를 분석하였다. 입력 지진데이터로는 El Centro를 사용하였으며, OpenSees를 이용하여 강구조물의 선형 또는 비선형 거동을 비교 분석하였다. 그 결과, 선형해석은 수치해석과 하이브리드 응답형상이 매우 잘 일치하였으며, 비선형 해석은 재료 비선형성에 의한 영구변형의 차이는 발생하였으나 최대변위 및 전체응답형상은 매우 유사하였다. 또한, 하이브리드 실험 소요시간은 실제 가진 시간에 약 9.6%의 속도로 현재 국내에서 수행된 실험 중 가장 실시간에 근접한 실험이라 할 수 있다. 따라서, 본 하이브리드 실험은 구조물의 동적 거동을 예측하는데 적절하게 활용될 수 있으며, 공간적, 경제적 제약이 있는 진동대 실험을 대체할 수 있으리라 판단된다.

동적 지반강성을 갖는 지반-구조물계의 실시간 하이브리드 진동대 실험 (Real-Time Hybrid Shaking Table Test of a Soil-Structure Interaction System with Dynamic Soil Stiffness)

  • 이성경;민경원
    • 한국전산구조공학회논문집
    • /
    • 제20권2호
    • /
    • pp.217-225
    • /
    • 2007
  • 본 연구에서는 건물모델만을 물리적인 실험체로 이용하여 동적 지반강성을 갖는 지반-구조물계의 동적거동을 모사하기 위한 하이브리드 진동대 실험법을 제안하고 이를 실험적으로 검증하였다. 본 연구에서 제안되는 실험방법은 상부구조물과 진동대의 가속도를 계측하여 진동대 제어기로 피드백하고, 전체 지반-구조물계의 동적거동을 묘사하기 위해 요구되는 기초부분의 절대가속도 응답(가속도 피드백 방법) 또는 절대속도 응답(속도 피드백 방법)을 계산하여 진동대를 구동시키는 방법이다. 지반부분을 계산하기 위해서 이론적인 동적지반강성을 제안방법에 따라서 다르게 근사화하여 진동대 제어기에 반영함으로써 실험을 수행하였다. 기초 고정계 모델에 대한 실험으로부터 계측된 응답과 본 논문에서 가정한 지반-구조물 계에 대한 실험으로부터 측정된 응답을 비교하고, 진동대 제어기에 반영한 동적지반강성과 실험데이터를 이용하여 식별된 동적지반강성을 비교함으로써 본 논문에서 제안된 실험방법의 유효성을 검증하였다.

건축구조물의 2방향 진동제어를 위한 TLMD 제어성능평가 (Performance Evaluation of Tuned Liquid Mass Damper for Reducing Bi-directional Responses of a Building Structure)

  • 허재성;이성경;박은천;이상현;김홍진;조지성;조봉호;민경원
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2008년도 춘계학술대회논문집
    • /
    • pp.432-441
    • /
    • 2008
  • In this study, the control performance of a Tuned Liquid Mass Damper(TLMD) manufactured to reduce the orthogonal bi-directional responses of building structures was experimentally evaluated. the TLMD using only one control device reduce bi-directional responses of building structures by making the TLMD behave as TMD and TLCD to the strong and weak axial direction of building structures. first, the control performance was evaluated by forcing sinusoidal waves to a test model that the TLMD is installed on the scale-downed building structure. Second, the real-time hybrid shaking table test was performed to evaluate the performance of the vibration control system made up of numerical part as a scale-downed building structural model and a physical experimental part as a TLMD. the superiority of bi-directional vibration control performance of the manufactured TLMD was verified by comparing the uncontrolled and controlled results of these tests.

  • PDF

실시간 하이브리드 실험법을 이용한 동조액체댐퍼가 설치된 건물의 진동제어 (Vibration Control of a Building Structure with a Tuned Liquid Damper Using Real-Time Hybrid Experimental Method)

  • 이성경;이상현;민경원;박은천;우성식;정란
    • 한국전산구조공학회:학술대회논문집
    • /
    • 한국전산구조공학회 2006년도 정기 학술대회 논문집
    • /
    • pp.256-263
    • /
    • 2006
  • In this paper, an experimental hybrid method, which implements the earthquake response control of a building structure with a TLD(Tuned Liquid Damper) by using only a TLD as an experimental part, is proposed and is experimentally verified through a shaking table test. In the proposed methodology, the whole building structure with a TLD is divided into the upper TLD and the lower structural parts as experimental and numerical substructures, respectively. At the moment, the control force acting between their interface is measured from the experimental TLD with shear-type load-cell which is mounted on shaking table. Shaking table vibrates the upper experimental TLD with the response calculated from the numerical substructure, which is subjected to the excitations of the measured interface control force at its top story and an earthquake input at its base. The experimental results show that the conventional method, in which both a TLD and a building structure model are physically manufactured and are tested, can be replaced by the proposed methodology with a simple experimental installation and a good accuracy for evaluating the control performance of a TLD.

  • PDF