• Title/Summary/Keyword: 실내 이산화탄소 농도

Search Result 50, Processing Time 0.03 seconds

The Influence of Office Indoor Air Qualitys on the Dry Eye Symptom of Contact Lens Wearers (사무실 실내공기질과 콘택트렌즈 착용여부가 안구 건조증에 미치는 영향)

  • Kim, Dea Jong;Park, Moon Chan;Lee, Se Hoon;Kim, Hyun Uk;Lee, Wha Ja;Cha, Jung Won
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.17 no.2
    • /
    • pp.215-222
    • /
    • 2012
  • Purpose: This study was performed to investigate the influence of indoor air qualities of an office environment on dry eye syndrome for wearing contact lens and non-wearing contact lens. Methods: To study the effects of indoor air qualities on dry eye syndrome for seventy-one subjects, $CO_2$, temperature, humidity, TSP, PM10, HCHO were measured. Each subject was tested by a McMonnie's dry eye syndrome questionnaire, a Schirmer Tear Test-I (S.T.T-I), a Schirmer Tear Test-II with anesthetics (S.T.T-II), and Tear film break-up time (T.B.U.T) in the their offices. Results: There was significant relation between the indoor air quality and dry eye syndrome for wearing contact lens and non-wearing when TSP was over $200{\mu}g/m^3$, PM10 was higher than $86.7{\mu}g/m^3$ and Formaldehyde was over $0.4{\sim}1.0{\mu}g/m^3$. However, there was no significant effect on dry eye syndrome with $CO_2$ (p=.0146), temperature (p=0.074) and humidity (p=0.053). Conclusions: It was indicated that $CO_2$, temperature and humidity were no effect on dry eye syndrome in the office environment. However TSP, PM10, formaldehyde, and wearing contact lens were effect on dry eye syndrome. Therefore, the entire management of wearing contact lens and the individual evaluation of the indoor air quality are required.

Study for the Geochemical Reaction of Ca-feldspar, Amphibole and Olivine with Supercritical $CO_2$ and Brine on the $CO_2$ Sequestration Condition (이산화탄소 지중저장 조건에서 초임계이산화탄소와 염수 반응에 의한 Ca-사장석, 각섬석, 감람석의 지화학적 변화 연구)

  • Kang, Hyun-Min;Park, Min-Ho;Park, Sang-Hee;Lee, Min-Hee;Wang, Soo-Kyun
    • Economic and Environmental Geology
    • /
    • v.44 no.2
    • /
    • pp.123-133
    • /
    • 2011
  • The lab scale experiments to investigate the geochemical reaction among supercritical $CO_2$-mineral-brine which occurs at $CO_2$ sequestration sites were performed. High pressurized cell system (l00 bar and $50^{\circ}C$) was designed to create supercritical $CO_2$ in the cell, simulating the sub-surface $CO_2$ storage site. From the high pressurized cell experiment, the surface changes of Ca-feldspar, amphibole (tremolite) and olivine, resulted from the supercritical $CO_2$-mineral-brine reaction, were observed and the dissolution of minerals into the brine was also investigated. The mineral slabs were polished and three locations on the surface were randomly selected for the image analysis of SPM and the surface roughness value (SRV) of those locations were calculated to quantify the change of mineral surface for 30 days. At a certain time interval, SPM images and SRVs of the same mineral surface were acquired. The secondary minerals precipitated on the mineral surfaces were also analyzed on SEM/EDS after the experiment. From the experiments, the average SRV of Ca-feldspar increased from 2.77 nm to 20.87 nm for 30 days, suggesting that the dissolution of Ca-feldspar occurs in active when the feldspars contact with supercritical $CO_2$ and brine. For the amphibole, the average SRV increased from 2.54 nm to 8.31 nm and for the olivine from 0.77 nm to 11.03 run. For the Ca-feldspar, $Ca^{2+}$, $Na^+$, $Fe^{2+}$, $Si^{4+}$, $K^+$ and $Mg^{2+}$ were dissolved in the highest order and $Si^{4+}$, $Ca^{2+}$, $Fe^{2+}$ and $Mg^{2+}$ for the amphibole. Fe (or Mg) - oxides were precipitated as the secondary minerals on the surfaces of amphibole and olivine after 30 days reaction. Results suggested that $Ca^{2+}$, $Fe^{2+}$ and $Mg^{2+}$ rich minerals would be significantly weathered when it contacts with the supercritical $CO_2$ and brine at $CO_2$ sequestration sites.

Study on the Dissolution of Sandstones in Gyeongsang Basin and the Calculation of Their Dissolution Coefficients under CO2 Injection Condition (이산화탄소 지중 주입에 의한 경상분지 사암의 용해반응 규명 및 용해 반응상수값 계산)

  • Kang, Hyunmin;Baek, Kyoungbae;Wang, Sookyun;Park, Jinyoung;Lee, Minhee
    • Economic and Environmental Geology
    • /
    • v.45 no.6
    • /
    • pp.661-672
    • /
    • 2012
  • Lab scale experiments to investigate the dissolution reaction among supercritical $CO_2$-sandstone-groundwater by using sandstones from Gyeongsang basin were performed. High pressurized cell system (100 bar and $50^{\circ}C$) was designed to create supercritical $CO_2$ in the cell, simulating the sub-surface $CO_2$ storage site. The first-order dissolution coefficient ($k_d$) of the sandstone was calculated by measuring the change of the weight of thin section or the concentration of ions dissolved in groundwater at the reaction time intervals. For 30 days of the supercritical $CO_2$-sandstone-groundwater reaction, physical properties of sandstone cores in Gyeongsang basin were measured to investigate the effect of supercritical $CO_2$ on the sandstone. The weight change of sandstone cores was also measured to calculate the dissolution coefficient and the dissolution time of 1 g per unit area (1 $cm^2$) of each sandstone was quantitatively predicted. For the experiment using thin sections, mass of $Ca^{2+}$ and $Na^+$ dissolved in groundwater increased, suggesting that plagioclase and calcite of the sandstone would be significantly dissolved when it contacts with supercritical $CO_2$ and groundwater at $CO_2$ sequestration sites. 0.66% of the original thin sec-tion mass for the sandstone were dissolved after 30 days reaction. The average porosity for C sandstones was 8.183% and it increased to 8.789% after 30 days of the reaction. The average dry density, seismic velocity, and 1-D compression strength of sandstones decreased and these results were dependent on the porosity increase by the dissolution during the reaction. By using the first-order dissolution coefficient, the average time to dissolve 1 g of B and C sandstones per unit area (1 $cm^2$) was calculated as 1,532 years and 329 years, respectively. From results, it was investigated that the physical property change of sandstones at Gyeongsang basin would rapidly occur when the supercritical $CO_2$ was injected into $CO_2$ sequestration sites.

Indoor Air Quality Index for School Classrooms Based on Health Effects (학교 교실 공기질 관리를 위한 건강영향 기반 실내공기질지수 개발)

  • Kim, Do Yun;Kwon, Ji You;Lee, Tae Jung;Park, Young Koo;Jo, Young Min
    • Journal of Environmental Impact Assessment
    • /
    • v.30 no.6
    • /
    • pp.380-392
    • /
    • 2021
  • An indoor air quality index for school classrooms based on the Hazard Quotient (HQ) was developed in this study. The current index (IAQI-S) covered PM10, PM2.5, and CO2, and breakpoints of IAQI-S were calculated using each HQ value. IAQI-S was applied to the real-time data obtained from 123 classrooms of 46 schools during November 2017 to December 2020. As a result of the comprehensive assessment, 93.1% of PM10 and 94% of PM2.5 belonged to 'good' and 'moderate', respectively. The IAQI-S based on an 8-hour predicted moving average was compared with Comprehensive Air-quality Index (CAI) and with the IAQI of a foreign reference. The IAQI-S includes CO2 and consists of more stringent levels comparing to outdoor index (CAI).

The Distribution Characteristics of Carbon Dioxide in Indoor School Spaces (교육시설 실내공간의 이산화탄소 농도분포 특성 연구)

  • Cho, Young-Min;Lee, Ji-Yun;Kwon, Soon-Bark;Park, Duck-Shin;Park, Jae-Hyoung;Cho, Ki-Chul
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.27 no.1
    • /
    • pp.117-125
    • /
    • 2011
  • There are many studies reporting the average carbon dioxide levels in various indoor spaces. However, there have been a few studies showing how carbon dioxide concentration varied at many measurement points in one indoor space. In this study, the changes of indoor carbon dioxide concentration at classroom, library, and kindergarten were reported to find its carbon dioxide distribution change at various locations and altitudes. The maximum carbon dioxide concentration of the 3 sites were measured as 2,684, 2,295, and 1,526 ppm, respectively. These values exceeded the guideline concentration of 1,000 ppm for public places. The concentration of carbon dioxide was higher at upper area than lower area, and this is probably due to the rise of warm breathing air generated from students. In the upper area, the carbon dioxide concentration was higher at center area than four corners. However, in the lower area, the carbon dioxide concentration was higher at four corners than center area. Therefore, it could be concluded that the center of upper area is the best place for the installation of ventilation or carbon dioxide removal system.

A Study on the Low Concentration Carbon Dioxide Adsorbent and Optimal Conditions (저농도 이산화탄소 포집용 흡착제 개발 및 최적조건에 관한 연구)

  • Lee, Ju-Yeol;Park, Duck-Shin;Cho, Young-Min;Kwon, Soon-Park;Hwang, Yoon-Ho;Song, Hyung-Jin;Lee, Sang-Bong
    • Journal of the Korean Applied Science and Technology
    • /
    • v.29 no.1
    • /
    • pp.1-12
    • /
    • 2012
  • In this study, $CO_2$ adsorbent was developed for removing low concentration of $CO_2$ in multiple-use facilities. The efficiency of the adsorbent which was improved selective $CO_2$ adsorption capabilities was evaluated. The pellet type adsorbent was modified from a commercial zeolite with mixing LiOH, binder, additives, and $H_2O$. Column tests showed over 90 % of $CO_2$ was adsorbed within 400min. Chamber tests including batch and continuous types were performed for evaluating the adsorbent module. By batch tests, it was evaluated that about 92% of $CO_2$ was removed within 30 min. By continuous tests, 70% of $CO_2$ was removed within 30 min. It was analyzed that over 2,500 ppm of $CO_2$ was continuously removed as shown chamber tests. The reproducibility tests repeatedly performed for 15 days shows that over 1,000 ppm of $CO_2$ was continuously removed. Adsorption capacity of the developed adsorbent was 5.0mmol $CO_2/g$ adsorbent which was analyzed by TGA. It was estimated that the modified adsorbent was applicable to low $CO_2$ concentration and low temperature of indoor environment.

The pH Reduction of the Recycled Aggregate Originated from the Waste Concrete by the scCO2 Treatment (초임계 이산화탄소를 이용한 폐콘크리트 순환골재의 중성화)

  • Chung, Chul-woo;Lee, Minhee;Kim, Seon-ok;Kim, Jihyun
    • Economic and Environmental Geology
    • /
    • v.50 no.4
    • /
    • pp.257-266
    • /
    • 2017
  • Batch experiments were performed to develop the method for the pH reduction of recycled aggregate by using $scCO_2$ (supercritical $CO_2$), maintaining the pH of extraction water below 9.8. Three different aggregate types from a domestic company were used for the $scCO_2$-water-recycled aggregate reaction to investigate the low pH maintenance of aggregate during the reaction. Thirty five gram of recycled aggregate sample was mixed with 70 mL of distilled water in a Teflon beaker, which was fixed in a high pressurized stainless steel cell (150 mL of capacity). The inside of the cell was pressurized to 100 bar and each cell was located in an oven at $50^{\circ}C$ for 50 days and the pH and ion concentrations of water in the cell were measured at a different reaction time interval. The XRD and SEM-EDS analyses for the aggregate before and after the reaction were performed to identify the mineralogical change during the reaction. The extraction experiment for the aggregate was also conducted to investigate the pH change of extracted water by the $scCO_2$ treatment. The pH of the recycled aggregate without the $scCO_2$ treatment maintained over 12, but its pH dramatically decreased to below 7 after 1 hour reaction and maintained below 8 for 50 day reaction. Concentration of $Ca^{2+}$, $Si^{4+}$, $Mg^{2+}$ and $Na^+$ increased in water due to the $scCO_2$-water-recycled aggregate reaction and lots of secondary precipitates such as calcite, amorphous silicate, and hydroxide minerals were found by XRD and SEM-EDS analyses. The pH of extracted water from the recycled aggregates without the $scCO_2$ treatment maintained over 12, but the pH of extracted water with the $scCO_2$ treatment kept below 9 of pH for both of 50 day and 1 day treatment, suggesting that the recycled aggregate with the $scCO_2$ treatment can be reused in real construction sites.

The $CO_2$ Recovering Recipe used Oxy Combustion with the Submerged Natural Gas Burner (천연가스 수중연소기(SMV)에서 순산소연소를 활용한 $CO_2$ 회수방안)

  • Sohn, Whaseung;Kim, Hoyeon;Ha, Jongmann;Kim, Joonseok
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2010.06a
    • /
    • pp.157-157
    • /
    • 2010
  • 우리나라는 기후변화협약에 대응하기 위한 교토의정서를 비준한 국가로서, 아직 온실가스의 의무감축 대상 국가는 아니다. 그러나 2012년부터 시작될 교토의정서 2차 공약기간 중에 브라질, 중국 및 인도와 같이 2차 의무감축대상이 가장 유력시 되는 국가로 지목되고 있으므로, 이러한 변화에 능동적으로 대처할 수 있는 기술적, 사회적, 정책적 방안이 신속히 마련될 필요가 있다. CCS(carbon capture & storage)란 화석연료로 부터 연소시 대기 중으로 배출되는 온실가스($CO_2$)를 포집하여 재생 또는 지중, 해양에 저장하는 기술로서 국가녹색성장 핵심기술중의 하나로 분류되며, 대료적인 $CO_2$ 발생대상인 석탄화력발전소로 부터 $CO_2$ 회수방안, 회수, 처리관련 연구를 포함하여 국내외 적으로 활발한 연구가 이루어 지고 있다. 순산소 연소기술을 통한 $CO_2$ 회수, 처리기술은 연료(천연가스, 석탄, 석유)의 산화제를 공기대신 순도 95% 이상의 고농도 산소를 이용하여 순산소연소를 하며, 이때 발생하는 배가스의 대부분은 $CO_2$와 수증기로 구성되어 있다. 발생된 배가스의 약 70~80%를 다시 연소실로 재순환시켜 연소기의 열적 특성에 적절한 연소가 가능하도록 최적화함과 동시에 배가스의 $CO_2$ 농도를 80% 이상으로 농축시켜 회수를 용이하게 하며, 특히 공해물질은 NOx 발생량을 10ppM 이하로 줄일 수 있다. 천연가스가 생산되는 LNG기지에서 LNG를 기화시키기 위하여 해수식 기화기(ORV : Open Rack Vaporizer와 수중연소식 기화기(SMV ; Submerged Combustion Vaporizer)를 사용하고 있으며, 특히 SMV는 버너를 이용하여 $-162^{\circ}C$ LNG를 $10^{\circ}C$의 LN로 기화시키는 설비로서 이때 연소시 $CO_2$를 상당량 발생시킨다. 본 논문에서는 SMV에서 순산소 연소방식을 적용하여 연료인 천연가스를 연소시키고, 이때 발생되는 $CO_2$와 수분이 주 성분인 배가스를 연소기에 재순환시켜, 연소실내 고온문제를 해결하며, 최종적으로 배가스중 $CO_2$$-162^{\circ}C$의 LNG 냉열을 이용하여 고순도의 액체 $CO_2$로 액화시키므로서 $CO_2$의 회수, 처리문제를 해결하는 방식을 소개하고자 한다. 이러한 방식은 천연가스에서 발생되는 $CO_2$ 회수를 LNG 냉열을 활용하므로서 폐열을 활용하는 에너지 효율적인 문제와 사용가능한 고순도 $CO_2$로 회수하므로서 환경적인 문제를 처리하는 기술이라 할 수 있다.

  • PDF

A Studs on Farmers Syndrome and Its Risk Factors of Vinylhouse Workers and Evaluation of Risk Factors of Vinylhouse Works (일부 농촌지역 비닐하우스 농사자들의 작업환경 및 농부증 실태와 관련요인평가)

  • Lee, Jung-Jeung
    • Journal of agricultural medicine and community health
    • /
    • v.29 no.1
    • /
    • pp.101-119
    • /
    • 2004
  • Objectives: In order to estimate risk factors affecting the health of vinylhouse workers and harmful environments in vinylhouse working. Methods: The investigator performed questionnaires and laboratory examinations on 102 vinylhouse workers and 69 farmers in 7 myoens (Korean subcounties). one eup (a Korean town), Goryeong-gun, Gyeongsangbuk-do between April 8 and 18, 2004 (for 11 days), and measured the heavy metal in the air and the soil, temperature, humidity, air current, harmful gases in vinylhouses. Results: Even in cloudy days, the temperature in vinylhouses in daylight was $33.4^{\circ}$ and the temperature difference between inside and outside vinylhouses was around $16^{\circ}$. Oxygen concentration was similar inside and outside vinylhouses, while carbon dioxide concentration was lower inside than outside vinylhouses. Carbon monoxide was not detected. In the air inside vinylhouses, cadmium was not detected. Lean concentration in the soil was lower inside vinylhouses than outside vinylhouses at surface, while cadmium concentration was similar inside and outside vinylhouses in the soil except some areas. Out of male vinylhouse workers. 16.4---- were positive farmer's syndrome and 49.2---- were suspicious, while out of females, 41.5---- were positive and 46.3---- were suspicious. Out of male farmers, 30.4---- were positive farmer's syndrome, while out of female farmers, 60.0---- were positive and 28.3---- were suspicious. There was no difference between vinylhouse workers and farmers in the distribution of hypertension and abnormal liver function, while diabetes mellitus was more common in farmers than in vinylhouse workers. Vinylhouse working, sex, and hours of farming per day were selected as significant variables affecting farmer's syndrome in this study, and the rate of positive farmer's syndrome was rather lower in vinylhouse workers than in farmers. Females were higher than males in the rate, and those who farmed at least 10 hours per day were higher in the rate than those who farmed less than 10 hours per day. Out of the vinylhouse workers, no differences were found between the distribution of farmer's syndrome and farming-related variables such as the total period of farming, the size of farm land, the mean farming hours per day, the number of family members who farm together, the frequency of scattering agricultural chemicals. In addition, there were no differences between the distribution and the wearing masks and protectors and personal sanitation among those who scattered agricultural chemicals by themselves. There were no differences found in blood lean concentration, urinary cadmium concentration, serum cholinesterase, and hemoglobin according to the distribution of farmer's syndrome. In the vinylhouse workers, females were higher than males in the rate of farmer's syndrome, and those who farmed at least 10 hours per day were higher in the rate than those who farmed less than 10 hours per day. Meanwhile, the rate was lower in those who slept at least 8 hours a day than in those who slept less than 8 hours. Conclusions: In conclusion, the physical environments inside vinylhouses were harmful, but no significant difference was found in harmfulness of the chemical environments. The chronic diseases such as farmer's syndrome. hypertension, diabetes, and dyshepatia were not common in the vinylhouse workers than in the farmers. Meanwhile, farmer's syndrome was more common in the vinylhouse workers who worked longer and slept less.

  • PDF

Evaluation of Scab Resistance and Effect of Photosynthetic Rates on Fruit Characteristics among Elite Pear Seedlings (배 우량계통의 검은별무늬병 저항성 평가 및 광합성률이 과실 품질에 미치는 영향 구명)

  • Won, Kyung-Ho;Kang, Sam-Seok;Kim, Yoon-Kyeong;Sherzod, Rajametov;Lim, Kyeong-Ho;Lee, Han-Chan
    • Korean Journal of Environmental Agriculture
    • /
    • v.32 no.2
    • /
    • pp.117-122
    • /
    • 2013
  • BACKGROUND: The scab, which is caused by Venturia nashicola, gives serious damages to pear trees. 'Niitaka' accounts for 82% of areas in pear cultivation. However 'Niitaka' is a scab susceptible cultivar. So, most of Korean farmers who growing pear trees have suffered by economic losses with the scab. In this research, we evaluated the scab resistance among elite pear seedlings to clarify genetics about the scab resistance. And we analyzed photosynthetic features with these seedlings to develop suitable cultivar which is advantageous for producing quality fruits during the growth and development of plants. METHODS AND RESULTS: We measured the rates of scab incidence among seedlings in a field experiment condition and an in-vitro test. An in-vitro test has been done with field experiment-based results. We made plant materials by grafting branches of each seedlings with 'Kongbae' rootstocks. And they had been grown for one month. Then, scab conidia suspension is sprayed to seedlings and sustained for 40 days under the controlled environment. As the results, 6 seedlings displayed lower incidence rates than other seedlings and 'Niitaka'. We also measured instant photosynthetic rates of each seedlings to determine the correlation between photosynthetic rates and fruit characteristics. However, it seemed that there is no correlation between them. CONCLUSION(S): Among the seedlings, 6 seedlings displayed the higher resistance to scab than other seedlings and 'Niitaka'. This characteristics is considered to be come from the gene expression of European pear. And we found that photosynthetic rate in trees rarely does not influence the fruit characteristics. It is considered to be affected by cultivar's own characteristics.