A Study on the Indoor Thermal Environment of the Large Enclosure Without Cooling Loads from Occupancy in Summer (대공간내 인체발열 미고려시의 하계 온열환경 조사)

  • Jeong, Seong-Jin;Choi, Dong-Ho;Yang, Jeong-Hoon;Seok, Ho-Tae
    • Proceeding of KASS Symposium
    • /
    • 2008.05a
    • /
    • pp.3-8
    • /
    • 2008
  • The purpose of this study is to provide fundamental cooling design data for the large public enclosures as gymnasium. This study executed indoor thermal environment verification of the existing gymnasium by measuring temperature distribution with cooling the space in summer. Cooling loads from human body was not considered. We examined various indoor thermal environment factors of the large enclosed space in this study which include vertical and horizontal temperature distribution, supply and return air flow feature, thermal comfort environment feature, amount of ventilation and etc.

  • PDF

A study on university office worker's perception of indoor air quality (Focused on K university) (사무실 근로자들의 실내공기질 인식에 관한 기초 조사 (K대학교를 중심으로))

  • Shin, Eun-Young;Kim, Gwang-Hee
    • The Journal of Sustainable Design and Educational Environment Research
    • /
    • v.16 no.3
    • /
    • pp.69-76
    • /
    • 2017
  • Indoor Air Quality(IAQ) affects physical and mental state of person who is residing indoor. Also, it manages daily life condition of Indoor Air in the building. According to the study, office workers spend 23 hours and 12 minutes, about 97% of his/her day indoor. Therefore, Indoor air quality affects not only the health of the person whose staying inside for a long hours but also the productivity and efficiency of work. This study conduct investigations on employees' awareness of indoor air quality of office in university. By doing so, we are able to determine current situation and provide basic data of improvement for derived problems. As a result, most of the respondents were not satisfied with ventilation and moisture which are elements of Indoor Air Quality. These led people to struggle with symptoms of health. Therefore, to improve the indoor air quality of a university office, it is necessary to exchange the air six times an hour according to recommendation of Refrigeration and Air Conditioning Engineers (ASHRAE)in the United States. Also, plan for Ventilation system that consider temperature, humidity and air flow indoor shall be provided for high quality conformability. furthermore, It is necessary to consider the multilateral in factors of generation of revenue through health care savings of workers and improvement of productivity.

Study on Indoor Flow According to Vane Angle of Square Ceiling Type Louver Diffuser (사각 천장형 루버 디퓨저의 토출 각도에 따른 실내유동에 관한 연구)

  • Jang, Heon-Deock;Lee, Dae-Hui;Lee, Jin-Ho
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.36 no.7
    • /
    • pp.683-687
    • /
    • 2012
  • The purpose of this paper is to numerically study the characteristics of the indoor air flow of a square ceiling type diffuser according to the vane angle and flow rate. The CFX of ANSYS 13.0 was used for the CFD tool. The size of the room is $6m(X){\times}6m(Y){\times}2.7m(Z)$. The exhaust diffuser was positioned diagonally to the supply diffuser. This diffuser was designed to have many holes, so the air supply had long throw patterns with low velocity decay. The characteristics of the indoor air flow was studied at volume flow rates of 5.1 CMM and 7.4 CMM, and a vane angle from $30^{\circ}$ to $60^{\circ}$, every $10^{\circ}$.

A Study on Estimation of Ventilation Performance in the Underground Parking Lot (지하 주차장의 환기성능평가에 관한 연구)

  • Hwang, Min-Kyu;Kim, Seong-Sik;Kim, Kang-Soo
    • Journal of the Korean Solar Energy Society
    • /
    • v.27 no.3
    • /
    • pp.71-77
    • /
    • 2007
  • In past, parking lot was placed on the ground and for the reason air quality was not in problem. But recently parking lot has been placed under the ground and the air quality becomes problem. So in this study, the ventilation performance on the underground parking lot was estimated by using CFD software and alternative system was suggested. Three case studies are handled in this study. 1st case is just an underground parking lot. 2nd case is about an underground parking lot where has 4 fan rooms on each floor and 3rd case is about an underground parking lot where has 4 fan rooms and 30 guidance fans on each floor.

Numerical analysis of local exhaust effectiveness using reverse-flow calculation method (역유동계산법을 이용한 국소배기효율의 수치해석)

  • 한화택
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.10 no.6
    • /
    • pp.658-665
    • /
    • 1998
  • This paper investigates local exhaust effectiveness in a room with a supply and an exhaust slots on the ceiling. The mean age of air is an indicator of supply effectiveness, while the mean residual life time can be used as an indicator of exhaust effectiveness. The distribution of local mean residual life time in a space is calculated by four different numerical procedures. The reverse-flow calculation method has been proved to show quite accurate results while it can save considerable amount of computation time and efforts, compared to the method by its original definition. It is concluded that the diffusion term in the equation of mean residual life time can be neglected. The spatial and temporal diffusion characteristics of the contaminant are also discussed.

  • PDF

The Study on Indoor Thermal Environment during Convection Heating - Thermal Comfort by Indoor Air Temperature and Velocity - (대류난방시 실내열환경에 관한 연구 - 온도 및 기류속도에 대한 온열쾌적감-)

  • Kim Dong-Gyu;Chung Yong-Hyun
    • Journal of Environmental Science International
    • /
    • v.14 no.2
    • /
    • pp.209-214
    • /
    • 2005
  • Draft is defined as an unwanted local cooling of the human body caused by air movement. It is a serious problem in many ventilated or air conditioned buildings. Often draft complaints occur although measured velocities in the occupied zone maybe lower than prescribed in existing standards. Purpose of this study is to clarify the evaluation of thermal comfort based on temperature and air velocity in winter. Experiments were performed in an environmental chamber in winter. Indoor temperature and air velocity was artificially controlled. The experiments were performed to evaluate temperature conditions and air velocity conditions by physiological and psychological responses of human. According to physiological responses and psychological responses, it was clear that the optimum air velocity is about 0.15 m/s and 0.30 m/s.

CFD Analysis Based Optimal Temperature Measurement (CFD 해석 기반 실내 최적 온도 계측)

  • Lee, Min-Goo;Park, Yong-Kuk;Jung, Kyung-Kwon;Yoo, Jun-Jae
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2011.05a
    • /
    • pp.735-738
    • /
    • 2011
  • This paper proposed the method to find out the optimal sensing point of temperature in test-bed with the sensor of temperature, such as real residence. We selected optimal locations by checking temperature change which was simulated by the means of CFD (Computational Fluid Dynamics) and the variation of air flow. We installed 30 temperature sensors in real place. After that, we compared the real one with the result of simulation.

  • PDF

The measurement of $O_3$ by passive sampler in indoor air of the residences (Passive sampler를 이용한 일반 주택에서의 실내 $O_3$ 농도 측정)

  • 신동천;박성은;김효진;김호현
    • Proceedings of the Korea Air Pollution Research Association Conference
    • /
    • 2000.11a
    • /
    • pp.441-442
    • /
    • 2000
  • 오존은 질소산화물, 일산화탄소 및 휘발성 유기화학물질 등의 광화학반응에 의해 생성되는 2차 오염물질이다(Haagen-Smit and Fox, 1953). 오존은 낮은 농도에서도 인체 및 식물에게 영향을 미치는 것으로 알려져 있다. 우리나라에서도 오존의 대기환경기준을 8시간 평균 0.06ppm, 1시간 평균 0.10ppm으로 낮추고, 오존예보제ㆍ경보제 등을 운영하여 오존에 의한 영향을 줄이고자 노력하고 있다. 그러나 서울과 같은 도시 밀집지역은 자동차의 밀집과 대형건축물의 증가, 기류 정체로 오염물질의 확산이 어렵고 도심지 내 열섬(heat island)현상으로 대기온도가 증가하여 오존생성에 유리한 조건을 형성함으로 인해 연평균 오염도가 1990년 이후 꾸준히 증가하고 있는 추세이다. (중략)

  • PDF

Air-conditioning System for Thermal Presentation (열환경 제시를 위한 공조 시스템의 개발)

  • 김영일;장영수;정구헌;이기섭
    • Proceedings of the Korean Society for Emotion and Sensibility Conference
    • /
    • 1998.04a
    • /
    • pp.275-280
    • /
    • 1998
  • 인간의 감성에 영향을 미치는 요인은 다양하나 이 중에서도 열환경은 인간에게 미치는 정도가 어떠한 요인보다도 큰 것으로 알려져 있다. 열환경이라 함은 온도, 습도, 기류, 복사열을 말하며 이 요소들과 인간의 감성과는 밀접한 관련을 지닌다. 열환경과 관련된 인간의 감성을 측정, 평가하기 위해서는 주위의 열환경이 정밀하게 제어되는 공간에서 작업이 이루어져야 한다. 실내 공간의 열환경을 임의로 제어하기 위해서는 급기되는 공기의 조건과 벽체의 온도가 정밀하게 제어되어야 한다. 공기와 벽체 조건은 가열, 냉각, 가습 또는 제습에 의하여 정밀하게 제어되며 이를 실현하기 위하여 공조 시스템은 일반적인 시스템과는 달리 특수한 조건이 요구된다. 공조 시스템의 각 구성요소가 컴퓨터에 의해 개별적으로 제어될 수 있어야 하며 특수 조건에 따른 유연성이 뛰어나야 한다. 본 연구에서는 열환결 제시에 적합한 공조 시스템을 개발한다.

  • PDF

Effects of the Floor Pannel on Flows in a Vertical Laminar Flow Type Clean Room (수직 층류형 클린룸의 바닥 패널이 실내기류에 미치는 영향)

  • Kang, S.H.;Jeon, W.P.;Oh, M.D.
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.2 no.4
    • /
    • pp.303-315
    • /
    • 1990
  • Uniformity of velocity is quite important design points of a vertical laminar flow type clean room. In the present paper, flows in a room with a bottom pannel are numerically simulated by using a low-Reynolds number $k-{\epsilon}$ model, and a new flow model of the pannel are suggested. Resistance coefficient of the pannel and size of the exhaust channel show considerable effects on flow pattern and uniformity of flow on the bottom. Reflection coefficient also has important roles. A possibility to obtain the uniform and unidirectional flow is tested by adjusting the distribution of resistance coefficient of the pannel. Such a numerical simulation of the flow will be a good method to get optimun design parameters.

  • PDF