• Title/Summary/Keyword: 실내온도

Search Result 914, Processing Time 0.037 seconds

Design and Implementation of Automatic Fan On/Off for Energy Saving (에너지 절감을 위한 선풍기 자동 ON/OFF 기능의 설계 및 구현)

  • Jang, Junewoo;Park, Seongjin;Ko, Hyeon
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2018.10a
    • /
    • pp.5-8
    • /
    • 2018
  • Recently, global warming and tropical nights have caused the use of electric fans to explode. Under these circumstances, running the fan for long periods of time is not only a risk of explosion due to overloading the power but also a small amount of electricity and environmental pollution. Therefore, the research was conducted to develop devices that automatically turn fans on and off according to room temperature, reducing the risk of explosion as well as saving energy. This study suggested that electric fans turn on and off automatically and display temperature in mobile applications. The ability to turn on and off allows the fan to turn on itself if the indoor temperature rises above a certain level. Conversely, if the indoor temperature drops below a certain level, the fan should be turned off. Second, the temperature display function checks indoor temperature through mobile applications. The automatic on/off capabilities proposed in this study could contribute to reducing the risk of explosion and saving energy. However, if the indoor temperature rises above a certain temperature even though there is no one inside, the fan can be turned on. The expectation from this study is that the ability of fans to operate and turn off at appropriate temperatures can reduce the risk of explosion, electrical charges, and environmental pollution.

  • PDF

Comparison of Rooftop Surface Temperature and Indoor Temperature for the Evaluation of Cool Roof Performance according to the Rooftop Colors in Summer: Using Thermal Infrared Camera Mounted on UAV (옥상 색상에 따른 쿨루프 성능평가를 위한 여름철 옥상 표면 및 실내온도 비교 분석 : 무인항공기에 장착된 열적외선 카메라를 이용하여)

  • Lee, Ki Rim;Seong, Ji Hoon;Han, You Kyung;Lee, Won Hee
    • Journal of the Korean Society of Surveying, Geodesy, Photogrammetry and Cartography
    • /
    • v.37 no.1
    • /
    • pp.9-18
    • /
    • 2019
  • The intensity and the number of days of high temperature occurrence are also high and record heat occurred. In addition, the global warming phenomenon is intensifying globally, and especially in South Korea, the urban heat island phenomenon is also occurring due to rapid urbanization due to rapid industrial development. As the temperature of the city rises, it causes problems such as the comfort of the residential living and the cooling load. In this study, the cool roof performance is evaluated according to the roof color to reduce these problems. Unlike previous studies, UAV(Unmanned Aerial Vehicle) thermal infrared camera was used to obtain the surface temperature (white, grey, green, blue, brown, black) according to the rooftop color by remote sensing technique. As a result, the surface temperature of white color was $11{\sim}20^{\circ}C$ lower than other colors. Also air conditioning temperature of white color was $1.5{\sim}4.4^{\circ}C$ lower than other colors and the digital thermometer of white color was about $1.5{\sim}3.5^{\circ}C$ lower than other colors. It was confirmed that the white cool roof performance is the best, and the UAV and the thermal infrared camera can confirm the cool roof performa.

Study of Deterioration Improvement of Power Fuse (전력퓨즈의 열화현상 개선에 관한 연구)

  • Song, Jae-Ki;Kim, Hwan-Yong
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.15 no.6
    • /
    • pp.3827-3831
    • /
    • 2014
  • This paper aims to solve the problem deterioration of power fuses. The deterioration of a power fuse is a cause of failure misoperation by a normal current flowing reduplicatively to fuse the element. An extension survey of a load feature rerating power fuse examined the power fuse deterioration removal, the cause of the deterioration of the power fuse, the front-after, and the thermal variation of the inside transformer room electric power equipment. The transformer showed an average improvement of $6[^{\circ}C]$. The temperature of the electrical line showed $7{\sim}8[^{\circ}C]$ improvement. The static condenser and direct reactor was $2{\sim}3[^{\circ}C]$ high-state maintenance the temperature and equipment syntonization relationship. In the subject of study $0.5{\sim}1.0[^{\circ}C]$ stabilizing three phase power fuse temperature differential was. Suggestion in the transformer room environment power equipment between the cause temperature happen elimination to deterioration of power fuse and temperature rise control.

A Efficient Control of Wind Velocity Using Thermal Images and a Fuzzy Control Method (퍼지 제어 기법과 열 영상을 이용한 효율적인 풍속 제어)

  • Kim, Ji-hyun;Woo, Young Woon;Kim, Kwang-beak
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2009.05a
    • /
    • pp.391-395
    • /
    • 2009
  • 최근 한정된 자원으로 인한 에너지 수요가 증가하면서 에너지 절약 문제가 중요한 과제로 대두되었다. 본 논문에서는 효율적인 에너지 절약 문제를 해결하기 위한 방법으로 열 영상과 퍼지 제어 기법을 적용하여 실내 냉방 장치의 풍향과 풍속을 제어하는 방법을 제시한다. 본 논문에서는 실내 냉방 장치의 풍향과 풍속을 제어하기 위해 획득한 초기 열 영상을 색상 분포 영상으로 변환한다. 색상 분포 영상은 Red, Magenta, Yellow, Green, Sky, Blue의 온도 값을 가지는 RGB 값이며 각 색상은 $24.0^{\circ}C$에서 $27.0^{\circ}C$의 분포의 온도 값을 가진다. 본 논문에서는 색상 분포 영상을 좌에서 우로 5개의 계층 구간으로 분류하여 온도를 분석한다. 실내 공간의 색상 분포 영상을 분석하여 얻어진 각 계층 구간의 온도와 대기 중의 습도를 퍼지 소속 함수에 적용하여 구해진 결과 값을 비퍼지화 하고 최종적으로 풍향의 세기를 제어한다. 그리고 열 영상을 분석하여 풍향의 우선순위, 풍향의 지속시간을 결정한다. 제안된 방법을 $300{\times}400$ 크기의 열 영상을 대상으로 기존의 시스템과의 전력량 차이를 시뮬레이션 한 결과, 제안된 방법이 효과적인 것을 확인할 수 있었다.

  • PDF

A study of method to refrain from the winding temperature rising of three-phase induction motor (고압전동기 권선온도 냉각설비 개선 사례 연구)

  • Choi, In-Seok;Hong, Jeong-Jo;Lee, Eun-Chun;Hong, Young-Jae;Hong, Hyun-Pyo
    • Proceedings of the KIEE Conference
    • /
    • 2015.07a
    • /
    • pp.831-832
    • /
    • 2015
  • K-water에서는 대청댐 하류의 용수를 취수하여 대청광역 계통에 1일 98만㎥을 공급할수 있는 현도취수장을 운영하고 있다. 취수장에는 고압전동기 10대가 운영되고 있으며, 장시간 연속운전 및 하절기 주위온도 상승 등으로 권선온도가 상승되어 설비의 안전성 문제가 제기되어 왔다. 취수펌프동 실내온도 및 고압전동기 권선온도 저감을 위해 펌프동 배기시스템 운영시간 변경 및 고압전동기 냉각 흡기덕트 설치 등의 개선 노력으로 권선온도 저감은 물론 에너지절감 및 기기의 수명연장 등 설비 운영의 안전성을 확보한 연구결과이다.

  • PDF

Experimental Analysis of Thermal Comfort for Ceiling and Floor Supply Air-conditioning Systems (냉방시 천장분출 및 바닥분출 공조방식에 따른 열환경 평가실험)

  • Cho, Yong;Kwon, Hurk-Seung;Kim, Sung-Hyun;Kim, Yong-Il
    • Proceedings of the Korean Society for Emotion and Sensibility Conference
    • /
    • 1998.11a
    • /
    • pp.133-139
    • /
    • 1998
  • 생활수준이 향상됨에 따라 인간의 감성을 생활환경에 적용하려는 연구가 진행되고 있다. 감성에 영향을 미치는 요인은 다양하나 이 중에서도 열환경은 인간에게 미치는 정도가 어떠한 요인보다도 큰 것으로 알려져 있다. 열환경이라 함은 온도, 습도, 기류, 복사열을 말하며 이 요소들은 인간의 감성과 밀접한 관련을 지닌다. 실내의 열환경은 공조방식에 따라 크게 달라지며 본 연구에서는 천장분출과 바닥분출 공조방식의 비교실험을 수행하여 실내의 열환경을 평가한다. 두 공조방식을 여름철 사무실 공간을 모사하는 열환경챔버에 적용하여 실내의 온도, 기류, 복사온도, PMV의 분포를 측정한다. 실험 결과 바닥분출 공조방식이 쾌적성과 에너지 절약면에서 우수함을 알 수 있었다.

  • PDF

A study on the room heating by solar assisted heat pump using the alternatives (대체냉매적용 태양열 열펌프시스템에 의한 난방성능분석(1))

  • 선경호;정현채
    • Proceedings of the Korea Society for Energy Engineering kosee Conference
    • /
    • 1995.05a
    • /
    • pp.94-99
    • /
    • 1995
  • 본 연구는 태양열 열펌프시스템에 의한 약 6평 규모의 실내의 난방방법으로서 간접 난방인 온수순환난방과 직접난방인 복사난방의 성능을 분석하였다. 태양열 열펌프의 최대의 열적성능을 나타낼 수 있도록 알루미늄 롤 본드형 태양열 집열기의 면적을 조절하였으며 집열효과를 극대화하기 위하여 온도감응 자동팽창밸브의 용량을 변화시켰다. 본 실험에서 적용된 태양열 열펌프 난방은 서울지방 봄 가을철의 외기온도에서 실내온도가 18~2$0^{\circ}C$로 유지되도록 설계제작되었다. 태양열 열펌프시스템에 적용된 작용유체는 온수순환 난방에는 R-12냉매. 그 대체냉매는 R-134a 및 혼합냉매, 복사난방에는 R-22냉매이었다.

  • PDF

Analysis of Thermal Comfort for Ceiling and Floor Supply Air-conditioning System (냉방시 천장분출 및 바닥분출 공조방식에 따른 열환경 평가)

  • 이기섭;김영일
    • Proceedings of the Korean Society for Emotion and Sensibility Conference
    • /
    • 1998.04a
    • /
    • pp.249-254
    • /
    • 1998
  • 생활수준이 향상됨에 따라 인간의 감성을 생활환경에 적용하려는 연구가 진행되고 있다. 감성에 영향을 미치는 요인은 다양하나 이 중에서도 열환경은 인간에게 미치는 정도가 어떠한 요인보다도 큰 것으로 알려져있다. 열환경이라 함은 온도, 습도, 기류, 복사열을 말하며 이 요소들은 인간의 감성과 밀접한 관련을 지닌다. 실내의 열환경은 공조방식에 따라 크게 달라지며 본 연구에서는 천장분출과 바닥분출 공조방식에 따른 실내의 열환경을 평가한다. 두 공조방식을 여름철 사무실 공간에 적용하여 실내의 온도, 기류, 복사온도, PMV의 분포를 수치해석적으로 계산한다. 해석 결과 바닥분출 공조방식이 쾌적성과 에너지 절약면에서 우수함을 알 수 있었다.

  • PDF