• Title/Summary/Keyword: 실내바닥의 안전성

Search Result 6, Processing Time 0.023 seconds

A Study on Accidents Occurred in Primary Schools and on the Experimental Test of the Safety of Building Floors (초등학교의 시설물 관련 안전사고 실태분석 및 실내바닥의 거주안전성에 관한 실험적 연구)

  • Choi, Soo-Kyung;Park, Chan-Joo;Kim, Soo-Gil
    • Journal of the Korean Institute of Educational Facilities
    • /
    • v.17 no.3
    • /
    • pp.21-32
    • /
    • 2010
  • The purpose of this study is to examine the improvement of the slipperiness of building floors and to test the safety in accidental collision in the primary schools. To perform this purpose effectively, the actual 20,202 cases of accident on the year 2000-2009 which had been dealt by Seoul School Safety and Insurance Association were analysed in several aspects. And to test the current slipperiness and hardness of building floors, 3 primary schools whose construction year differed were examined. This study found that among the indoor accidents of 2,646 cases on the year 2000-2002, 70.7% accidents of them were caused by slipperiness. It was also found that the building floors of the primary schools could not be safe from the result of examining the slipperiness and hardness of the building floors. As the result of this study, it showed that the desirable efficient criterion of slipperiness would be more than C.S.R 0.4, and that of safety in accidental collision would be less than Gs 100G for the safety of primary school students.

Factors Related to Housing Safety and Improved End-of-Life Care for Elderly People (노인의 라이프케어 증진을 위한 주거안전 영향 요인도출)

  • Kim, Ju-Hong;Oh, Myung-Hwa
    • Journal of Korea Entertainment Industry Association
    • /
    • v.13 no.6
    • /
    • pp.341-351
    • /
    • 2019
  • This study examines factors related to the safety of housing for elderly people. Because of the diverse problems that may occur due to aging, elderly residents may have special needs related to housing. To identify relevant factors, first, focus group interviews were conducted with six individuals aged 65 or older. Then, a Delphi survey was conducted on experts; this survey consisted of a questionnaire on factors related to the safety of housing for elderly people. Issues to address in the questionnaire were identified in the focus group interviews and also through an examination of literature published domestically and overseas. In the Delphi survey, opinions were collected from the experts; these opinions were then revised, collated, and analyzed. The factors identified in these steps were verified using a content validity index. As a result, a total of seven primary factors - outdoor environment, entrance, indoor environment, living room, bedroom, kitchen, bathroom, and restroom - and 23 sub-factors related to elderly people's housing safety were identified. The most frequently mentioned factors were indoor and outdoor stairs, safe flooring materials, and indoor thresholds. It is essential to identify the factors that most affect the safety of elderly people in their residences.

A Study on the Fire Drill Behavior Characteristics in Rehabilitation Center for Visually Impaired Persons (시각장애인 복지관의 화재 피난행태 특성분석 연구)

  • Lee, Jeong-Soo;Kwon, Heung-Soon;Kim, Eung Sik
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.16 no.8
    • /
    • pp.5646-5653
    • /
    • 2015
  • This study focused on the architectural, interior and management guidelines in rehabilitation center for visually impaired persons. For these purposes, we reviewed the movement behaviors and the characteristics of fire drill in rehabilitation center for visually impaired persons. The results are as follows. : First, the liner circulation paths and interior landmarks are recommended, and dwelling units and program rooms should be located in ground floor for barrier free evacuation. Second, It is important to establish continuous handrail, variations of paving patterns and materials, good color definition, tactile informations and directional sound. Third, it is necessary to serve more specified architectural, interior, and management guidelines according to impaired prototypes.

Design and Manufacture of Improved Obstacle-Overcoming type Indoor Moving and Lifting Electric Wheelchair (향상된 장애물 극복형 실내 이·승강 전동휠체어의 설계 및 제작)

  • Kim, Young-Pil;Ham, Hun-Ju;Hong, Sung-Hee;Ko, Seok-Cheol
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.21 no.11
    • /
    • pp.851-860
    • /
    • 2020
  • With an increase in the aging population and a rising social interest in health and welfare, studies to improve healthcare in the elderly are being actively conducted. This study attempted to improve the current design and manufacture of elevating electric wheelchairs to enhance user safety and convenience. Seat design based on the user's body shape, convenience while boarding or alighting, caster turning radius and, safety and stability features that prevent shaking when the user gets up or sits down were improved. A driving experiment was conducted to evaluate the operation of the indoor electric wheelchair designed and manufactured with these additional functionalities. During the test, the performance parameters evaluated were continuous driving time, turning radius, maximum lifting and lowering load, maximum lifting height, noise level, minimum distance sensing by the driving auxiliary sensor, ability to interact with server and app programs, and the duty cycle maximum error rate. The test confirmed that this improved electric wheelchair successfully met target parameters. In a future study, we will evaluate this improved electric wheelchair from a user's perspective for its usability parameters, such as satisfaction, convenience and stability.

Gas Explosion Hazard Analysis in Domestic (가정집에서 가스폭발 위험성 분석)

  • Jo Young-Do;Kim Ji-Yun;Kim Sang-sub
    • Journal of the Korean Institute of Gas
    • /
    • v.5 no.2 s.14
    • /
    • pp.36-42
    • /
    • 2001
  • A leak of fuel gas in partially confined area creates a flammable atmosphere and give rise to an explosion, which is one of the most common accident in domestic. Observations from accident in domestic suggest that some explosions are caused by a quantify of fuel significantly less than lower explosion limit(LEL) amount required to fill the room, which is attributed to inhomogeneous mixing of leaked gas. The minimum amount of leaked gas for explosion is highly dependent on the mixing degree in the area. For lighter gas, such as methane, a high concentration tends to build up in the space from ceiling of room. But heavy gas, such as propane, a high concentration tends to build up in the space from bottom of room. This paper presents a method for analysing the explosion hazard in a room with very small amount of leaked gas. Based on explosion limit concentration, the gaussian distribution model is used to estimate the minimum amount of leak which yields a specified explosion pressure. The results demonstrate that catastrophic structural damage can be achieved with a volume of fuel gas which is less than 0.5 percent of the total enclosed volume in domestic. The method will help analyzing hazard to develop new safe device as well as investigating accident.

  • PDF

Radon concentration measurement at general house in Pusan area (부산지역 일반주택에서의 라돈농도측정)

  • Im, In-Cheol
    • Journal of radiological science and technology
    • /
    • v.27 no.2
    • /
    • pp.29-33
    • /
    • 2004
  • Until early 1980s we have lived without thinking that radon ruins our health. But, scientists knew truth that radon radioactive danger is bedeviling on indoor that we live for a long time. Specially, interest about effect that get in danger and injury for Radon and human body is inactive in our country. Recently, with awareness for Radon contamination, We inform about importance and danger of Radon in some station of the Seoul subway, indoor air of school facilities and We had interest with measure and manages. Usually, Radon gas emitted in base of building enters into indoor through building floor split windage back among radon or indoor air of radon daughter nucleus contamination is increased. Therefore, indoor radon concentration rises as there are a lot of windages between number pipe of top and bottom and base that enter crack from estrangement of the done building floor, underground to indoor. Thus, Radon enters into indoor through architecture resources water as well as, kitchen natural gas for choice etc., but more than about 85% from earth's crust emit. Danger and injury of health by Radon and Radon daughter nucleus that is indicated for cause of lung cancer incerases content of uranium of soil rises specially from inside pit of High area and a mine, cave, hermetical space with house. Safe sub-officer of radon concentration can not know and danger always exists large or small during. So, Important thing reduces danger of lung cancer by lowering concentration of Radon within house and building. Therefore, is thought that need general house Radon concentration measurement, measured Radon concentration monthly using Sintillator radon monitor. Study finding appeared high all underground market 1 year than the ground, and the winter appeared high than the summer. Specially, month that pass over 4pCi in house that United States Environmental Protection Agency advises appeared in underground, and appeared and know Radon exposure gravity by 4 months during 12 months. Therefore, Thinking that establishment and regulation of norm and preparation of reduction countermeasure about Radon are pressing feels, and inform result that measure Radon concentration.

  • PDF