전통주택의 차음성능 평가에 관한 실험적 연구 (An Experimental Study on the Sound Insulation Performance of Korean Traditional Houses)

  • 김선우;이태강;김형렬;김항;최은석
    • 한국소음진동공학회논문집
    • /
    • 제16권2호
    • /
    • pp.141-148
    • /
    • 2006
  • Korean traditional houses have been evolved and developed in many years, adopting the natural environment to control exterior conditions. These control method are various Passive system of using natural materials, considering micro climate, building lay out, and these system are much natural and ecological to make the comfortable indoor climate than active systems of the present houses. This study aims to analyzed the acoustical characteristics of Korean traditional houses varied with lay out and floor plan to reflect the way of control for environmental condition. The reverberation time and level difference between rooms of the main living room and other main floored room, master room and kitchen are measured in each houses. As a result, the reverberation time of Korean traditional rooms are below 0.6 second, and the sound insulation performance of Korean traditional door are mostly very low grade with D-15. The level difference between rooms are low grade not to meet minimum class except between main living room and master room away from main living building. These above results show that our traditional house are much more emphasized seeking visual privacy of rooms than aural privacy.

전남 지방 전통주택의 음향특성에 관한 실험적 연구 (An Experimental Study on the Acoustic Characteristic of Korean Traditional Houses in Chonnam Province)

  • 이태강;김형렬;김항;최은석;김선우
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2005년도 추계학술대회논문집
    • /
    • pp.686-689
    • /
    • 2005
  • This study aims to analyzed the acoustics characteristics of Korean Traditional Houses in Chonnam Province varied with lay out and floor plane to reflect the way of control for environmental condition. These houses are surveyed the reverberation time and level difference between rooms of the main living room and other main floored room, master room and kitchen. As a result, the reverberation time of traditional rooms are below 0.6 second, and the sound insulation performance of Korean traditional door are mostly very low grade with D-15. The level difference between rooms are low grade not to meet minimum class except between main living room and master room away from main living building.

  • PDF

현장실험을 통한 학교교실의 벽체 차음성능 및 측로전달소음 조사 (Investigation of the sound insulation performance of walls and flanking noises in classrooms using field measurements)

  • 류다정;박찬재;한찬훈
    • 한국음향학회지
    • /
    • 제36권5호
    • /
    • pp.329-337
    • /
    • 2017
  • 미국과 영국에서는 교실의 적정한 음환경을 제공하기 위하여 잔향시간 및 배경소음에 대한 기준이 수립되어 있다. 또한 이를 실현하기 위한 건축계획방법 및 실내마감재 적용에 대한 가이드라인을 제시하고 있다. 그러나 대한민국의 경우 학교 교실의 배경소음 기준을 만족하기 위한 가이드라인이 부족할 뿐만 아니라 이에 기초가 되는 교실 벽체의 차음성능에 대한 실태조사가 부족한 실정이다. 본 연구에서는 학교 교실의 실내외 소음에 대한 차음성능을 조사하기 위하여 대한민국 청주시 소재 중학교 2개소의 외부벽체와 실간벽체의 구조를 조사하였다. 실내외 벽체의 차음성능 및 측로전달소음을 비교분석하기 위하여 투과손실, 가중 표준화 음압레벨차, 음향 감쇠 계수, 신호대잡음비 등을 측정하였다. 연구결과 실간벽체의 경우 건식벽으로 건립된 학교의 차음성능이 습식벽보다 높게 나타났으며, 특히 중고파수대역에서 높은 차음성능을 나타내었다. 외부벽체의 경우 각 학교 별로 차음성능을 비교하였을 때 단창을 이중으로 배치한 학교보다 복층유리를 사용한 학교의 성능이 더 높은 것으로 나타났다. 또한 측로전달소음의 경우 창문을 모두 개방하거나 복도 측 창문과 문을 연 경우 기준을 초과하는 것으로 나타나 내부 소음에 의해 학생이 음성전달에 방해를 받을 수 있음을 알 수 있었다.