• Title/Summary/Keyword: 신호 향상

Search Result 3,627, Processing Time 0.033 seconds

Analysis of the ESD and DAP According to the Change of the Cine Imaging Condition of Coronary Angiography and Usefulness of SNR and CNR of the Images: Focusing on the Change of Tube Current (관상동맥 조영술(Coronary Angiography)의 씨네(cine) 촬영조건 변화에 따른 입사표면선량(ESD)과 흡수선량(DAP) 및 영상의 SNR·CNR 유용성 분석: 관전류 변화를 중점으로)

  • Seo, Young Hyun;Song, Jong Nam
    • Journal of the Korean Society of Radiology
    • /
    • v.13 no.3
    • /
    • pp.371-379
    • /
    • 2019
  • The purpose of this study was to investigate the effect of the change in the X-ray condition on the entrance surface dose (ESD) and dose area product (DAP) in the cine imaging of coronary angiography (CAG), and to analyze the usefulness of the condition change on the dose relation and image quality by measuring and analyzing the Signal to Noise Radio (SNR) and Contrast to Nois Ratio (CNR) of the angiographic images taken by the Image J program. Data were collected from 33 patients (24 males and 9 females) who underwent CAG at this hospital from November 2017 to March 2018. In terms of imaging condition and data acquisition, the ESD and DAP of group A with a high tube current of 397.2 mA and group B with a low tube current of 370.7 mA were retrospectively obtained for comparison and analysis. For the SNR and CNR measurement and analysis via Image J, the result values were derived by substituting the obtained data into the formula. The correlations among ESD and DAP according to the change in the imaging condition, SNR, and CNR were analyzed by using the SPSS statistical analysis software. The relationships of groups A and B, having a difference in the imaging condition, mA, with ESD ($A:483.5{\pm}60.1$; $B: 464.4{\pm}39.9$) and DAP ($A:84.3{\pm}10.7$; $B:81.5{\pm}7$) were not statistically significant (p>0.05). In the relationships with SNR and CNR based on Image J, the SNR ($5.451{\pm}0.529$) and CNR ($0.411{\pm}0.0432$) of the images obtained via the left coronary artery (LCA) imaging of group B showed differences of $0.475{\pm}0.096$ and $-0.048{\pm}0.0$, respectively, from the SNR ($4.976{\pm}0.433$) and CNR ($0.459{\pm}0.0431$) of the LCA of group A. However, the differences were not statistically significant (p<0.05). In the SNR and CNR obtained via the right coronary artery (RCA) imaging, the SNR ($4.731{\pm}0.773$) and CNR ($0.354{\pm}0.083$) of group A showed increased values of $1.491{\pm}0.405$ and $0.188{\pm}0.005$, respectively, from the SNR ($3.24{\pm}0.368$) and CNR ($0.166{\pm}0.033$) of group B. Among these, CNR was statistically significant (p<0.05). In the correlation analysis, statistically significant results were shown in SNR (LCA) and CNR (LCA); SNR (RCA) and CNR (RCA); ESD and DAP; ESD and sec; DAP and CNR (RCA); and DAP and sec (p<0.05). As a result of the analyses on the image quality evaluation and usefulness of the dose change, the SNR and CNR were increased in the RCA images of the CAG obtained by increasing the mA. Based on the result that CNR showed a statistically significant difference, it is believed that the contrast in the image quality can be further improved by increasing the mA in RCA imaging.

Evaluation of Reasonable $^{18}F$-FDG Injected Dose for Maintaining the Image Quality in 3D WB PET/CT (PET/CT 검사에서 영상의 질을 유지하기 위한 적정한 $^{18}F$-FDG 투여량의 평가)

  • Moon, A-Reum;Lee, Hyuk;Kwak, In-Suk;Choi, Sung-Wook;Suk, Jae-Dong
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.15 no.2
    • /
    • pp.36-40
    • /
    • 2011
  • Purpose: $^{18}F$-FDG injected dose to the patient is quite different between the recommended dose from manufacturer and the actual dose applied to each of hospitals. injection of inappropriate $^{18}F$-FDG dose may not only increase the exposed dose to patients but also reduce the image quality. we thus evaluated the proper $^{18}F$-FDG injected dose to decrease the exposed dose to patients considering the image quality. Materials And Methods: NEMA Nu2-1994 phantom was filled with $^{18}F$-FDG increasing hot cylinder radioactivity concentration to 1, 3, 5, 7, 9 MBq/kg based on the ratio of 4:1 between the hot cylinder and background activity. after completing the transmission scan using ct, emission scan was acquired in 3D mode for 2 minutes 30 seconds/bed. ROI was set up on hot cylinder and background radioactivity region. after measuring $SUV_{max}$ those regions, then analyzed SNR at the points. clinical experiment has been conducted the object of patients who have came to smc from november 2009 to august 2010, 97 patients without having a hepatic lesions were selected. ROI was set up in the liver and thigh area. after measuring $SUV_{max}$, the image quality was compared following the injected dose. Results: in phantom study, as the injected radioactivity concentration per unit mass was 1, 3, 5, 7, 9 MBq/kg, $SUV_{max}$ was 23.1, 24.1, 24.3, 22.8, 23.6 and SNR was shown 0.48, 0.54, 0.56, 0.55, 0.55. according to increment of the injected dose, $SUV_{max}$ and SNR was increased under 5 MBq/kg but they were decreased over 7 MBq/kg. in case of clinical experiment, as increased the injected radioactivity concentration per unit mass was 4.72, 5.34, 6.16, 7.41, 8.68 MBq/kg, $SUV_{max}$ was 2.68, 2.67, 2.26, 1.88, 1.95 and SNR was shown 0.52, 0.53, 0.46, 0.46, 0.44. if the injected dose exceeds 5 MBq/kg, showed a decrease pattern as phantom study. Conclusion: increasing $^{18}F$-FDG injected dose considered patient's body weight improve image quality within a certain range. if it exceeds the range, it can be reduced image quality due to random and scatter coincidences. this study indicates that the optimal injected dose was 5 MBq/kg per unit mass the injected radioactivity concentration in 3d wb pet/ct.

  • PDF

Making Aids of Magnetic Resonacnce Image Susing 3D Printing Technology (3D 프린트를 활용한 자기공명영상검사 보조기구 제작)

  • Choi, Woo jeon;Ye, Soo young;Kim, Dong hyun
    • Journal of the Korean Society of Radiology
    • /
    • v.10 no.6
    • /
    • pp.403-409
    • /
    • 2016
  • MRI scan is a useful method in the diagnosis of musculoskeletal excellent contrast of the organization. Depending on the patient's musculoskeletal examinations state the type of aids provided the aid is used there is also challenging as well as the costs do not vary. This study was produced by the use of 3D printing technology, an MRI aids. Aids in the production process, then through 3D modeling and then convert stl files using (3D MAX.2014, Fusion360) slicing programs (Cubicreater 2.1ver., Cura 15.4ver) converted to G-code printed on the FDM scheme (Cubicon Style, output was MICRO MAKE). Output is, but in the FDM to evaluate the SNR on the MRI images were compared to the test is the case before use, and then to produce a Water Phantom case of a PLA, ABS, a TPU thickness 3mm, using aids before, It was evaluated in a clinical image after qualitatively. Obtaining an image of SNR Warter Phantom appeared to have been evaluated as T1 NON $123.778{\pm}28.492$, PLA $123.522{\pm}28.373$, ABS $124.461{\pm}25.716$, TPU $124.843{\pm}27.272$. T2 NON $127.421{\pm}26.949$, was rated as PLA $124.501{\pm}27.768$, ABS $128.663{\pm}26.549$, TPU $130.171{\pm}25.998$. The results did not show statistically significant differences. The use of assistive devices before and after images Clinical evaluation method palliative $3.20{\pm}0.88$, $3.95{\pm}0.76$ after using the aids used to aid improved the quality of the image. Production of the auxiliary mechanism using a future 3D printing is expected are thought to be used clinically, it can be an aid making safe and comfortable than the inspection of the patient is an alternative to improve the problems of the aids used in the conventional do.

Shielding Design Optimization of the HANARO Cold Neutron Triple-Axis Spectrometer and Radiation Dose Measurement (냉중성자 삼축분광장치의 차폐능 최적화 설계 및 선량 측정)

  • Ryu, Ji Myung;Hong, Kwang Pyo;Park, J.M. Sungil;Choi, Young Hyeon;Lee, Kye Hong
    • Journal of Radiation Protection and Research
    • /
    • v.39 no.1
    • /
    • pp.21-29
    • /
    • 2014
  • A new cold neutron triple-axis spectrometer (Cold-TAS) was recently constructed at the 30 MWth research reactor, HANARO. The spectrometer, which is composed of neutron optical components and radiation shield, required a redesign of the segmented monochromator shield due to the lack of adequate support of its weight. To shed some weight, lowering the height of the segmented shield was suggested while adding more radiation shield to the top cover of the monochromator chamber. To investigate the radiological effect of such change, we performed MCNPX simulations of a few different configurations of the Cold-TAS monochromator shield and obtained neutron and photon intensities at 5 reference points just outside the shield. Reducing the 35% of the height of the segmented shield and locating lead 10 cm from the bottom of the top cover made of polyethylene was shown to perform just as well as the original configuration as radiation shield excepting gamma flux at two points. Using gamma map by MCNPX, it was checked that is distribution of gamma. Increased flux had direction to the top and it had longer distance from top of segmented shield. However, because of reducing the 35% of the height, height of dissipated gamma was lower than original geometry. Reducing the 35% of the height of the segmented shield and locating lead 10cm from the bottom of the top cover was selected. After changing geometry, radiation dose was measured by TLD for confirming tester's safety at any condition. Neutron(0.21 ${\mu}Svhr^{-1}$) and gamma(3.69 ${\mu}Svhr^{-1}$) radiation dose were satisfied standard(6.25 ${\mu}Svhr^{-1}$).

The Simulation for the Organization of Fishing Vessel Control System in Fishing Ground (어장에 있어서의 어선관제시스템 구축을 위한 모의실험)

  • 배문기;신형일
    • Journal of the Korean Society of Fisheries and Ocean Technology
    • /
    • v.36 no.3
    • /
    • pp.175-185
    • /
    • 2000
  • This paper described on a basic study to organize fishing vessel control system in order to control efficiently fishing vessel in Korean offshore. It was digitalized ARPA image on the fishing processing of a fleet of purse seiner in conducting fishing operation at Cheju offshore in Korea as a digital camera and then simulated by used VTMS. Futhermore, it was investigated on the application of FVTMS which can control efficiently fishing vessels in fishing ground. The results obtained were as follows ; (1) It was taken 16 minutes and 35 minutes to casting and hauling net in fishing processing respectively. The length of rope pulled by scout boat was 200m, tactical diameter in casting net was 340.8m, turning speed was 6kts as well. (2) The processing of casting and hauling net was moved to SW, NE as results of simulation when the current direction and speed set into NE, 2kts and SW, 2kts respectively. Such as these results suggest that can predict to control the fishing vessel previously with information of fishing ground, fishery and ship's maneuvering, etc. (3) The control range of VTMS radar used in simulation was about 16 miles. Although converting from a radar of the control vessel to another one, it was continuously acquired for the vector and the target data. The optimum control position could be determined by measuring and analyzing to distance and direction between the control vessel and the fleet of fishing vessel. (4) The FVTMS(fishing vessel traffic management services) model was suggested that fishing vessels received fishing conditions and safety navigation information can operate safely and efficiently.

  • PDF

Performance Analysis of Slave-Side Arbitration Schemes for the Multi-Layer AHB BusMatrix (ML-AHB 버스 매트릭스를 위한 슬레이브 중심 중재 방식의 성능 분석)

  • Hwang, Soo-Yun;Park, Hyeong-Jun;Jhang, Kyoung-Son
    • Journal of KIISE:Computer Systems and Theory
    • /
    • v.34 no.5_6
    • /
    • pp.257-266
    • /
    • 2007
  • In On-Chip bus, the arbitration scheme is one of the critical factors that decide the overall system performance. The arbitration scheme used in traditional shared bus is the master-side arbitration based on the request and grant signals between multiple masters and single arbiter. In the case of the master-side arbitration, only one master and one slave can transfer the data at a time. Therefore the throughput of total bus system and the utilization of resources are decreased in the master-side arbitration. However in the slave-side arbitration, there is an arbiter at each slave port and the master just starts a transaction and waits for the slave response to proceed to the next transfer. Thus, the unit of arbitration can be a transaction or a transfer. Besides the throughput of total bus system and the utilization of resources are increased since the multiple masters can simultaneously perform transfers with independent slaves. In this paper, we implement and analyze the arbitration schemes for the Multi-Layer AHB BusMatrix based on the slave-side arbitration. We implement the slave-side arbitration schemes based on fixed priority, round robin and dynamic priority and accomplish the performance simulation to compare and analyze the performance of each arbitration scheme according to the characteristics of the master and slave. With the performance simulation, we observed that when there are few masters on critical path in a bus system, the arbitration scheme based on dynamic priority shows the maximum performance and in other cases, the arbitration scheme based on round robin shows the highest performance. In addition, the arbitration scheme with transaction based multiplexing shows higher performance than the same arbitration scheme with single transfer based switching in an application with frequent accesses to the long latency devices or memories such as SDRAM. The improvements of the arbitration scheme with transaction based multiplexing are 26%, 42% and 51%, respectively when the latency times of SDRAM are 1, 2 and 3 clock cycles.

Development and Feasibility Study for Phase Contrast MR Angiography at Low Tesla Open-MRI System (저자장 자기공명영상 시스템에서의 위상대조도 혈관조영기법의 개발과 그 유용성에 대한 연구)

  • Lee, Dong-Hoon;Hong, Cheol-Pyo;Lee, Man-Woo;Han, Bong-Soo
    • Progress in Medical Physics
    • /
    • v.23 no.3
    • /
    • pp.177-187
    • /
    • 2012
  • Magnetic resonance angiography (MRA) techniques are widely used in diagnosis of vascular disorders such as hemadostenosis and aneurism. Especially, phase contrast (PC) MRA technique, which is a typical non contrast-enhanced MRA technique, provides not only the anatomy of blood vessels but also flow velocity. In this study, we developed the 2- and 3-dimensional PC MRA pulse sequences for a low magnetic field MRI system. Vessel images were acquired using 2D and 3D PC MRA and the velocities of the blood flow were measured in the superior sagittal sinus, straight sinus and the confluence of the two. The 2D PC MRA provided the good quality of vascular images for large vessels but the poor quality for small ones. Although 3D PC MRA gave more improved visualization of small vessels than 2D PC MRA, the image quality was not enough to be used for diagnosis of the small vessels due to the low SNR and field homogeneity of the low field MRI system. The measured blood velocities were $25.46{\pm}0.73cm/sec$, $24.02{\pm}0.34cm/sec$ and $26.15{\pm}1.50cm/sec$ in the superior sagittal sinus, straight sinus and the confluence of the two, respectively, which showed good agreement with the previous experimental values. Thus, the developed PC MRA technique for low field MRI system is expected to provide the useful velocity information to diagnose the large brain vessels.

Biodistribution of Iodine-131-Iodomisonidazole and Imaging of Tumor Hypoxia in Mice bearing CT-26 Adenocarcinoma (CT-26 선암을 접종한 마우스에서 Iodine-131-Iodomisonidazole의 생체분포 및 종양저산소증의 영상화)

  • Kim, Hye-Won;Kim, Chang-Guhn;Yoon, Kwon-Ha;Kim, Hyun-Jeong;Juhng Seon-Kwan;Roh, Byung-Suk;Yang, David J.;Kim, E.Edmund;Lee, Hyun-Chul
    • The Korean Journal of Nuclear Medicine
    • /
    • v.33 no.3
    • /
    • pp.289-297
    • /
    • 1999
  • Purpose: Misonidazole is a radiosensitizer that binds in hypoxic cells. The purpose of this study was to find out the feasibility of I-131-Iodomisonidazole (IMISO) for imaging of tumor hypoxia. Materials and Methods: Tosyl precursor was dissolved in acetonitrile and I-131-NaI was added to synthesize IMISO. Balb/c mice inoculated with CT-26 adenocarcinoma were injected with IMISO. Mice were sacrificed at 1, 2, 4, 24 hr and % of injected dose per gram of tissue (%ID/g) was determined. For scintigraphy and MRI, mouse bearing CT-26 adenocarcinoma was administered with IMISO and imaging was performed 4 hr after. Then, mouse body was fixed and microtomized slice was placed on radiographic film for autoradiography Results: %ID/g of tumor was 1.64 (1h), 0.98 (2h), 0.85 (4h) and 0.20 (24h), respectively. At 24h, %ID/g of tumor was higher than that of all other tissues except thyroid. Tumor to muscle ratio increased with time and tumor to blood ratio also increased with time and reached 1.53 at 24 hr. On autoradiogram, tumor was well visualized as an increased activity in central hypoxic area of the tumor which corresponds to the area of high signal intensity on T2-weighted MR image. On scintigraphy, tumor uptake was visualized. Conclusion: This results suggest that IMISO may have a potential for tumor hypoxia imaging in mouse model. However, further study is needed to improve it's localization in tumor tissue and to achieve acceptable images of tumor hypoxia.

  • PDF

A Study on the Accuracy of the Loran-C Fix of Korean Chain in Pusan Area (부산지역에서의 Loran-C 한국체인의 측위정도에 관한 연구)

  • 박주삼
    • Journal of the Korean Society of Fisheries and Ocean Technology
    • /
    • v.32 no.4
    • /
    • pp.372-380
    • /
    • 1996
  • The operation of Far East Chain(GRI 5970) of Loran - C system had been stopped on June, 1995, but that of Korean Chain(GRI 9930) of Loran - C system which was jointed with North West Pacific Chain(GRI 8930) and Russia Chain(GRI 7950) by international cooperation, was started on January 1996. In this paper, in order to study the accuracy of Loran - C fix of Korean Chain, the authors examined and analyzed the data of the reciever of Loran - C(LC -90, Furuno) and GPS(AccNav Sport super (TM), Eagle) measured automatically and continually for 2 seconds at interval of 5 minutes from November 22, 1992, to January 20, 1996 at the fixed position of National Fisheries University of Pusan, The results obtained were as follows ; 1)The mean time differences of M-W, M-X, and M-Y pair measured in the base observed position were 12333.09${\mu}$s, 28338.44${\mu}$s, and 42806.01${\mu}$s respectively and the mean standard deviations of that were 0.0121${\mu}$s, 0.0290${\mu}$s, and 0.0327${\mu}$s respectively. The daily and monthly variance forms of time difference at each pair appeared in a similar reappearance. 2)The mean standard deviations of the latitude and longitude by Loran - C were 9.1m and 17.4m in W.X pair, 11.5m and 13.7m in W.Y pair, and 8.1m and 29.3m in X.Y pair respectively, and then the probable radiuses within 95% of each pair were 39.2m, 35.7m, and 60.8m, respectively. Therefore, It is to be desired that W.Y par is selected to improve the accuracy in Pusan area. 3)The mean standard deviations of the latitude and longitude by GPS were 15.4m and 15.0m and the probable radius within 95% was 43.4m. 4)The position errors for GPS and each pair of Loran - C were 16.0m to the South in GPS and 265.2m to the East in W.X pair of Loran - C, 279.5m to the North in W.Y pair of that, and 224.3m to the North-West in X.Y pair of that, so GPS is about 250m higher than Loran - C in accuracy.

  • PDF

Swell Effect Correction for the High-resolution Marine Seismic Data (고해상 해저 탄성파 탐사자료에 대한 너울영향 보정)

  • Lee, Ho-Young;Koo, Nam-Hyung;Kim, Wonsik;Kim, Byoung-Yeop;Cheong, Snons;Kim, Young-Jun
    • Geophysics and Geophysical Exploration
    • /
    • v.16 no.4
    • /
    • pp.240-249
    • /
    • 2013
  • The seismic data quality of marine geological and engineering survey deteriorates because of the sea swell. We often conduct a marine survey when the swell height is about 1 ~ 2 m. The swell effect correction is required to enhance the horizontal continuity of seismic data and satisfy the resolution less than 1 m. We applied the swell correction to the 8 channel high-resolution airgun seismic data and 3.5 kHz subbottom profiler (SBP) data. The correct sea bottom detection is important for the swell correction. To detect the sea bottom, we used maximum amplitude of seismic signal around the expected sea bottom, and picked the first increasing point larger than threshold value related with the maximum amplitude. To find sea bottom easily in the case of the low quality data, we transformed the input data to envelope data or the cross-correlated data using the sea bottom wavelet. We averaged the picked sea bottom depths and calculated the correction values. The maximum correction of the airgun data was about 0.8 m and the maximum correction of two kinds of 3.5 kHz SBP data was 0.5 m and 2.0 m respectively. We enhanced the continuity of the subsurface layer and produced the high quality seismic section using the proper methods of swell correction.