• Title/Summary/Keyword: 신호 해석

Search Result 1,840, Processing Time 0.025 seconds

A Study on Error Compensation for Quadrature Modulator in Frequency Direct Conversion Method (주파수 직접변환방식의 직교변조부 에러보정에 관한 연구)

  • 백주기;이일규;방성일;진년강
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.9 no.4
    • /
    • pp.542-551
    • /
    • 1998
  • In this study, a method of error compensation for channel gain imbalance, phase imbalance and local oscillator leakage in the modulator of frequency direct conversion is suggested. The compensation of channel imbalance can be carried out by using the received power after transmitting test signal. By applying this method, the phase imbalance conversion with frequency can be easily compensated since this method is rarely affected by the transmission channel. It is confirmed that the algorithm proposed in this study(iteration coefficient=11) converges faster than conventional algorithm(iteration coefficient=43). From the numerical results, the DC-offset, channel gain, phase imbalance compensation coefficient and iteration number converges into($f_1$=0.0199999, $f_2$=-0.050001, $C_{22}$=0.9133, $C_{12}$=-0.0524, N=13) when the local oscillator leakage is not considered. However, it converges into($f_1$=-0.02, $f_2$=-2.2476, $C_{22}$=0.9133, $C_{12}$=-0.0524, N=16) when the local oscillator leakage is considered.

  • PDF

SAR Analysis on the Coaxial-Slot Antenna for Hyperthermia (Hyperthermia용 Coaxial-Slot 안테나의 SAR 분석)

  • Shin, Kook-Sun;Shin, Ho-Sub;Kim, Nam
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.13 no.7
    • /
    • pp.732-739
    • /
    • 2002
  • Performance of the applicator for hyperthermia is determined by both the degree of impedance matching and specific absorption rate(SAR) distribution in the surrounding tissue. In this paper, the coaxial-slot antenna using staircasing approximation in the FDTD is analyzed and the coaxial-slot antenna for the hyperthermia improving heating characteristics is designed. The SAR of the coaxial-slot antenna approximated to staircasing and square model is analyzed, and the SAR of staircasing model is compared with Saito's SAR measurement and square model. As a result, the SAR of proposed model exhibited agreement with the Saito's measurement of square model. Ig averaged SAR on the liver caused by proposed antenna in this paper is 195 W/kg, and is about 27.9 % higher than the Saito's antenna 152.5 W/kg, respectively.

Electrical Characteristics on MOS Structure with Irradiation of Radiation (방사선이 조사된 MOS구조에서의 전기적 특성)

  • 임규성;고석웅;정학기
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2001.10a
    • /
    • pp.644-647
    • /
    • 2001
  • The investigations were discussed on the radiation effects of the electrical properties to the p-type MOS capacitors, which were irradiated by cobalt-60 gamma ray sources. The characteristics of capacitance-bias voltage(C-V) and of dielectric dissipation tarter-bias voltage(D-V) on the capacitors were measured at 1 [MHz] frequency. The microscopic behaviors of spate charges in oxide and silicon-silicon dioxide(Si- $SiO_2$) interface were investigated from the experimental data. The C-V characteristics are statical and convenient for the evaluation of the steady state behavior of carriers and interface states characteristics. While, the distribution and magnitude of space charges in oxide can be found out accurately on the $V_{dp}$ in D-V curves. The density of interface states can be deduced with ease from the magnitude of D-peak at depletion state. Thus, it is also concluded that the D-V curves are more useful and easier than conventional C-V curves for analysis of the microscopic and dynamic behavior of carriers in oxide and Si- $SiO_2$interface.

  • PDF

Measurement of High Electric Field Using Linear Electric-Optic Effect of Crystalline SiO$_2$ (SiO$_2$의 전기 광학 효과를 이용한 고전계 측정)

  • 김요희;이대영
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.17 no.2
    • /
    • pp.142-152
    • /
    • 1992
  • This paper presentes a new method to measure high electric field (or high voltage) by using crystalline SiO2 which has very high half wave voltage. There are many difficulties in measuring high electric field using other crystals which have generally low half wave voltage.By applying Stokes parameter and Mueller matrix. We derive optical modulation equation in the sensor which is composed of a polarizer, and Mueller matrix, we derive optical modulation equation in the sensor which is composed of a polarizer, a Pokels material, and an analyzer, We theoretically analyzed electro-optic effect, and calculated the phase retardation and half wave volt age of the birefringent material. The designed optical valtage sensor has very excellent linearity up to 20KV without divided volt-age. The maximum error was measured within 3%. Before annealing of Sio2 crystal, the maximum variation of the output voltage is 7.5% with varying temperature from \ulcorner20˚c to 60˚c. But, after annealing of SiO2 crystal, the output voltage variation is improved within 1%error.

  • PDF

Design and Performance Analysis of a Decision-feedback Coherent Code Tracking Loop for WCDMA Systems (WCDMA 시스템을 위한 판정궤환 동기식 동기추적 회로의 설계 및 성능분석)

  • 박형래;양연실;김영선;김창주
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.29 no.4A
    • /
    • pp.429-438
    • /
    • 2004
  • In this paper, a decision-feedback coherent code tracking loop is designed for WCDMA systems and its performance is analyzed in terms of jitter variance considering the effect of phase and symbol estimation errors for both AWGN and fading environments. An analytical closed-form formula for jitter variance is Int derived for AWGN environments as a function of a pulse-shaping filter, timing offset, signal-to-interference ratio, and loop bandwidth while involving the phase estimation error and bit error rate, and the upper bound of jitter variance is derived for fading environments. Finally a second-order coherent code tracking loop is designed with the DPCH frame format #13 of the WCDHA forward link selected as a target system, and its performance is evaluated by the closed-form formula and compared with the simulation results for both AWGN and Rayleigh fading environments.

Implementation of the Equalization Circuits for High Bandwidth Visible Light Communications Using Phosphorescent White LED (인광성 백색 LED의 가시광 통신 변조 대역폭 향상을 위한 등화기 구현)

  • Sohn, Kyung-Rak
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.39 no.4
    • /
    • pp.473-477
    • /
    • 2015
  • In this paper, a commercial phosphorescent white light-emitting diode (WLED) visible light communication (VLC) system with an equalization circuit to achieve the high modulation bandwidth was designed and demonstrated. An analytical method to examine the performance of the equalizer was carried out using a general circuit-simulator, PSpice. The equalization circuit was composed of two passive filters with resisters and a capacitor and an active filter with an op-amp. Utilizing our post-equalization technology, the ~3.5 MHz bandwidth of phosphor WLED could be extended to ~25 MHz without using an optical blue-filter. In this VLC system with a single round-type WLED and a single PIN photo-diode, ASK data transmission up to 35 Mbps at a 1m free space distance was obtained. The resulting bit-error-rate was $7.6{\times}10^{-4}$, which is less than the forward error correction (FEC) limit of $3.8{\times}10^{-3}$.

The Influence of MR Gradient Acoustic Noise on fMRI (MR 경사 자계 소음이 뇌기능 영상에 미치는 영향)

  • S. C. Chung
    • Investigative Magnetic Resonance Imaging
    • /
    • v.2 no.1
    • /
    • pp.50-57
    • /
    • 1998
  • MR acoustic sound or noise due to gradient pulsings has been one of the problems in MRI, both in patient scanning as well as in many areas of psychiatric and neuroscience research, such as brain fMRI. Especially in brain fMRI, sound noise is one of the serious noise sources which obscures the small signals obtainable from the subtle changes occurring in oxygenation status in the cortex and blood capillaries. Therfore, we have studied the effects of acoustic or sound noise arising in fMR imaging of the auditory, motor and visual cortices. The results show that the acoustical noise effects on motor and visual responses are opposite. That is, for the motor activity, it shows an increased total motor activation while for the visual stimulation, corresponding(visual) cortical activity has diminished substantially when the subject is exposed to a loud acoustic sound. Although the current observations are preliminary and require more experimental confirmation, it appears that the observed acoustic-noise effects on brain functions, such as in the motor and visual cortices, are new observations and could have significant consequences in data observation and interpretation in future fMRI studies.

  • PDF

Azimuth Accuracy Test of Phase Comparison Direction Finding Method Using F-16 Fighter Scale-down Model (F-16 전투기 축소모델을 사용한 위상비교 방향 탐지 기법의 방위각 정확도 시험)

  • Lim, Joong-Soo;Chae, Gyoo-Soo;Kim, Young-Ho;Kim, Kichul
    • Journal of Convergence for Information Technology
    • /
    • v.7 no.5
    • /
    • pp.83-88
    • /
    • 2017
  • This paper describes the azimuth accuracy test of phase comparison direction finding method using F-16 fighter scale-down model. When the antennas are placed on the bottom of a fighter, reflection signals caused by an aircraft structure arises and an azimuth error occurs. In this research, the F-16 fighter scale-down model was made to 5:1, and five antennas were placed on the bottom of the model, then the radio waves of emitters were received by the antennas in the $0-360^{\circ}$ azimuth angles. The accuracy test was performed by numerically analyzing the phases of the radio waves received by the five antennas. The azimuth error of the phase comparison direction finding with scale-down model was measured to be less than $0.5^{\circ}$ when the signal noise ratio was larger then 0dB, and it could be very useful for the design of the phase comparison direction finding method of the fighter.

Modulation Instability in Dispersion and Gain Managed Fibers (이득과 분산을 조절한 광섬유의 변조 불안정성 분석)

  • Choi, Byung-Hoon;Kim, Sang-In
    • Korean Journal of Optics and Photonics
    • /
    • v.18 no.2
    • /
    • pp.93-99
    • /
    • 2007
  • We investigated analytically and numerically the occurrence of modulation instability in fibers with periodic changes both in dispersion and gain. Previously, it has been known that the modulation instability is suppressed in dispersion managed solitons where dispersion is managed in such a way that the local dispersion alternates between the normal and the anomalous regimes. In this work, we enhanced the advantage of the dispersion management scheme by additionally introducing proper gain/loss profiles in fibers. The gain/loss profile is given by $\Gamma(z)=0.5/D(z)*(dD/dz)$, where D(z) represents the dispersion profile. The fundamental gain spectra of the modulation instability in the dispersion and gain managed fibers have been derived analytically and confirmed by numerical calculation. Our investigation reveals that in the dispersion and gain fibers the modulation instabilities are always much more suppressed compared to the case with only dispersion managed. In practical dispersion management schemes, dispersion profiles show discontinuity. and thus. the corresponding gain/loss profiles tend to be finite. In these cases, the gain/loss profiles were approximated by lumped gains/losses of finite values. Our numerical calculations confirm that this approximation also works well.

Modeling of a linear GMR Isolator Utilizing Spin Valves (스핀밸브를 이용한 선형 GMR 아이솔레이터의 모델링)

  • Park, S.;Jo, S.
    • Journal of the Korean Magnetics Society
    • /
    • v.14 no.6
    • /
    • pp.232-235
    • /
    • 2004
  • Linear GMR isolator which is profitable for transmitting analog signal was modeled and the output voltage and current in relation to the input current were investigated. GMR isolator modeling was divided into two parts, namely magnetic and electric parts. The flow chart of the modeling was drawn in which the MR curve of the spin valves were incorporated to obtain the electrical voltage output. For magnetic modeling, 3-dimensional model of planar coil was analyzed by FEM method to obtain the magnetic field strength corresponding to the input current. Coil efficiency of the planar coil having magnetic core layer was shown to have about 1.5 times larger than that of the coil without the magnetic core layer. The feedback coil current(output current) corresponding to the input coil current was calculated to be within ${\pm}$0.25 mA of the linear fitting function of I$\_$out/= I$\_$in/-5 mA. Also, the response time and output waveforms were obtained when the coil current was a rectangular waveform. The rise time and fall time was 6 ${\mu}\textrm{s}$, respectively when the slew rate of the op-amp was 0.3 V/${\mu}\textrm{s}$.