• Title/Summary/Keyword: 신뢰성지수

Search Result 73, Processing Time 0.03 seconds

Resistance Factor and Target Reliability Index Calculation of Static Design Methods for Driven Steel Pipe Pile in Gwangyang (광양지역에 적합한 항타강관말뚝의 목표신뢰성지수 및 저항계수 산정)

  • Kim, Hyeon-Tae;Kim, Daehyeon;Lim, Jae-Choon;Park, Kyung-Ho;Lee, Ik-Hyo
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.16 no.12
    • /
    • pp.8128-8139
    • /
    • 2015
  • Recently, the necessity of developing the load and resistance factor design(LRFD) for soft ground improvement method has been raised, since the limit state design is requested as international technical standard for the foundation of structures. In this study, to develop LRFD codes for foundation structures in Korea, target reliability index and resistance factor for static bearing capacity of driven steel pipe piles were calibrated in the framework of reliability theory. The 16 data(in Gwangyang) and the 57 data(Korea Institute of Construction Technology, 2008) sets of static load test and soil property tests conducted in the whole domestic area were collected along with available subsurface investigation results. The resistance bias factors were evaluated for the tow static design methods by comparing the representative measured bearing capacities with the expected design values. Reliability analysis was performed by two types of advanced methods : the First Order Reliability Method (FORM), and the Monte Carlo Simulation (MCS) method using resistance bias factor statistics. As a result, when target reliability indices of the driven pipe pile were selected as 2.0, 2.33, 2.5, resistance factor of two design methods for SPT N at pile tip less than 50 were evaluated as 0.611~0.684, 0.537~0.821 respectively, and STP N at pile tip more than 50 were evaluated as 0.545~0.608, 0.643~0.749 respectively. The result from this research will be useful for developing various foundations and soil structures under LRFD.

Study on the Agricultural Water Use Collection System for River Water Management (하천수 관리를 위한 농업용수 사용량 수집체계 구축 방안 연구)

  • Cho, Sang Uk;Baek, Jong Seok;Oh, Dong Heon;Kim, Chi Young;Sung, Ji Youn;Cha, Jun Ho
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2021.06a
    • /
    • pp.489-489
    • /
    • 2021
  • 생활·공업용수 목적의 하천수 사용량은 유량계 등 검증된 방법으로 사용량 계측 및 실적보고를 수행하고 있으나, 농업용수는 검증되지 않은 수문조작 등의 간접방법을 인정하고 있어 사용실적 자료의 신뢰도가 낮은 실정이다. 하천수의 효율적인 물 배분을 위해 농업용수 사용량 자료에 대한 신뢰도 확보 및 자료관리 기반 마련이 필요하다. 본 연구에서는 전국 수리권일제조사 자료를 이용하여 농업용수 사용시설에 대한 구분 및 정리를 통해 수집체계 구축 대상을 선정하고, 사용시설의 형태 및 규모에 따라 적정 계측기술 적용 방안 및 연차별 구축 계획을 통해 농업용수 사용량 자료를 관리할 수 있는 방안을 제시하였다. 조사된 전체 하천수 사용시설 중 제원정보 및 허가량이 유효한 14,575건 중 농업용수는 12,745건으로 개소수 대비 88.9%, 허가량 대비 81.3%(생활·농업·공업용수 대상)를 차지하고 있다. 이중 하천수 사용량 보고대상인 8,000 m3/일 이상의 1,696건에 대한 자료의 수집이 수행된다면, 전체 농업용수의 86.0%에 해당하는 사용량 자료를 확보할 수 있다. 수집체계 구축 대상 1,696건의 시설형태별(양수장, 취수보), 규모별(허가량 10만 m3/일 기준) 구분을 통해 취수보와 양수장의 최적 계측방법 선정 및 연차별 구축 계획을 수립하였다. 전국에 산재한 전체 농업용수 사용량 자료의 확보가 현실적으로 어렵기 때문에, 적정 개소수의 수집체계 구축 및 운영으로 전체 농업용수 사용량의 상당부분 자료를 확보할 수 있다면 실시간 하천수 관리 및 효율적인 물 배분을 위한 기반을 마련할 수 있을 것이라 기대한다.

  • PDF

Suggestion of an Evaluation Chart for Landslide Susceptibility using a Quantification Analysis based on Canonical Correlation (정준상관 기반의 수량화분석에 의한 산사태 취약성 평가기법 제안)

  • Chae, Byung-Gon;Seo, Yong-Seok
    • Economic and Environmental Geology
    • /
    • v.43 no.4
    • /
    • pp.381-391
    • /
    • 2010
  • Probabilistic prediction methods of landslides which have been developed in recent can be reliable with premise of detailed survey and analysis based on deep and special knowledge. However, landslide susceptibility should also be analyzed with some reliable and simple methods by various people such as government officials and engineering geologists who do not have deep statistical knowledge at the moment of hazards. Therefore, this study suggests an evaluation chart of landslide susceptibility with high reliability drawn by accurate statistical approaches, which the chart can be understood easily and utilized for both specialists and non-specialists. The evaluation chart was developed by a quantification method based on canonical correlation analysis using the data of geology, topography, and soil property of landslides in Korea. This study analyzed field data and laboratory test results and determined influential factors and rating values of each factor. The quantification analysis result shows that slope angle has the highest significance among the factors and elevation, permeability coefficient, porosity, lithology, and dry density are important in descending order. Based on the score assigned to each evaluation factor, an evaluation chart of landslide susceptibility was developed with rating values in each class of a factor. It is possible for an analyst to identify susceptibility degree of a landslide by checking each property of an evaluation factor and calculating sum of the rating values. This result can also be used to draw landslide susceptibility maps based on GIS techniques.

Ultimate Longitudinal Strength Analysis of Ship′s Hull Girder by Idealized Structural Unit Method (이상화(理想化) 구조요소법(構造要素法)에 의한 선체구조(船體構造)의 최종종강도(最終縱强度) 해석(解析))

  • Jeom-K. Paik
    • Journal of the Society of Naval Architects of Korea
    • /
    • v.28 no.1
    • /
    • pp.139-149
    • /
    • 1991
  • In this paper, an efficient method for the ultimate longitudinal strength analysis of the double skin hull girder is presented by using idealized structural unit method. Idealized plate element subjected to biaxial load is developed taking account of initial deflection and welding residual stress. Interaction effect between local and global buckling in the whole structure is also taken into consideration. The reserve strength factor and reliability index for the example 40K double skin product oil carrier are evacuated against the ultimate longitudinal strength. It is concluded that the prudent method seems to be useful in the sense that the computing time required is very short while giving the reasonable solution.

  • PDF

Establishment of Ultrasonic Measurement Method for Stone Cultural Heritage Considering Water Content and Anisotropy (함수율과 이방성을 고려한 석조문화유산의 초음파 측정방법 설정)

  • Jo, Young Hoon;Lee, Chan Hee
    • Journal of Conservation Science
    • /
    • v.30 no.4
    • /
    • pp.467-480
    • /
    • 2014
  • This study was focused on measurement methods for stone cultural heritages by analyzing Ultrasonic (P-wave) velocity variations according to the water content and anisotropy of rocks. As a result of analyzing of rock properties, the water content and saturation degree were rapidly changed at the beginning of drying and then showed exponential curve which their rates of change gradually decreased. However, P-wave velocity and its rate of change maintained constant values after natural drying of 10 hours. Therefore, the ultrasonic measurement for stone cultural heritages should be performed after natural drying of 10 hours considering the weather and moisture conditions. In addition, the highest values of anisotropy coefficient exhibited in granite and limestone, and indirect method was insensitive to anisotropy compared to direct method. However, all rocks remained anisotropy by indirect method. Accordingly, ultrasonic measurement considering various directions is required. The research results will contribute to customized non-destructive testing and precise diagnosis for lithological characteristics of stone cultural heritage.

A Study on electrical and mechanical reliability assessment of Sn-3.5Ag solder joint (Sn-3.5Ag BGA 솔더 조인트의 전기적, 기계적 신뢰성에 관한 연구)

  • Sung, Ji-Yoon;Lee, Jong-Gun;Yun, Jae-Hyeon;Jung, Seung-Boo
    • Proceedings of the KWS Conference
    • /
    • 2009.11a
    • /
    • pp.80-80
    • /
    • 2009
  • 패키징 구조의 발전이 점차 중요한 문제로 대두되어, 칩의 집적 기술의 발전에 따라 실장기술에서도 고속화, 소형화, 미세피치화, 고정밀화, 고밀도화가 요구되고있다. 최근 선진국을 중심으로 전자 전기기기 및 부품의 실장기술에서도 환경 친화적인 기술을 요구함에 따라, 저에너지 공정 및 무연 실장 기술에 대한 연구가 활발하게 진행되고 있다. 기존의 SOP(Small Out-line Package), QFP(Quad Flat Package) 등은 소형화, 다핀화, 고속화, 실장성에 한계가 있기 때문에, SMT(Surface Mount Technology) 형식으로 된 BGA(Ball Grid Array)가 휴대형 전화를 비롯한 기타 전자 부품 실장에 널리 사용되고 있다. BGA ball shear 법은 BGA 모듈의 생산 및 취급 중에 발생할지도 모르는 기판에 수평으로 작용하는 기계적인 전단력에 BGA solder ball이 견딜 수 있는 정도를 측정하기 위해 사용되는 시험법이다. 전단 시험에 의한 전단 강도의 측정 외에 전기전도도 측정, 파면 관찰, 이동거리(displacement), 유한요소 해석법 등을 병행하여 시험법의 신뢰성 향상에 대한 연구가 이루어지고 있다. 본 실험에서는 지름이 $500{\mu}m$인 Sn-3.5Ag 솔더볼을 이용하여 세라믹 기판을 접합하여 BGA 패키지를 완성하였다. 상부 기판에 솔더볼을 정렬시켜 리플로우 방법으로 접합 한 후 솔더볼이 접합된 상부 기판과 하부 기판을 접합 하여 시편을 제작하였다. 접합된 시편들은 $150^{\circ}C$에서 0~800시간 열처리를 실시하였고, 열처리를 하면서 각각 $3{\times}10^2A/cm^2,\;5{\times}10^3A/cm^2$의 전류를 인가하였다. 시편들을 전단 시험기를 이용하여 솔더볼의 기계적 특성 평가를 하였으며, 계면 반응을 관찰하였다.

  • PDF

Development and application of integrated indicators for assessing the water resources performance of multi-purpose and water supply dams (댐 용수공급능력 안정성 평가를 위한 통합지표 개발 및 적용)

  • Sung, Jiyoung;Kang, Boosik;Kim, Bomi;Noh, Seongjin
    • Journal of Korea Water Resources Association
    • /
    • v.55 no.9
    • /
    • pp.687-700
    • /
    • 2022
  • For comprehensively assessment the water resources performance of multi-purpose dams and water supply dams in South Korea, a methodology was proposed to utilize the durational reliability along with the integrated auxiliary indicators including resiliency, dimensionless vulnerability, water resource efficiency, specific inflow, and specific water supply. In addition, for the purpose of sustainable dam operation in the future, a plan to grade the water resources performance was presented to periodically evaluate the performance and determine the priority of each dam's structural or non-structural planning according to the evaluation results. As major results, in the case of Sumjingang Dam, the durational reliability was 99.0%, but the integrated auxiliary index was the lowest of 44 points, which was 5th grade. This means that despite the current high reliability, hydrological changes due to future climate change or regional change of water demand-supply balance can have significant impacts on the water resources performances. In contrast, the Chungju Dam with a durational reliability of 93.0%, which is below the average among all multi-purpose dams, shows the 76 points of the integrated auxiliary index, which is 3rd highest following the Soyanggang Dam and the Namgang Dam. Nevertheless, due to the size of the basin, the specific inflow is sufficiently high as 185%, so the actual performance could be evaluated relatively high. The water supply dams designed for a single purpose tend to be evaluated relatively high because they have a high proportion of industrial and municipal water supply and have enough room for the supply capacity.

TFN model application for hourly flood prediction of small river (소규모 하천의 시간단위 홍수예측을 위한 TFN 모형 적용성 검토)

  • Sung, Ji Youn;Heo, Jun-Haeng
    • Journal of Korea Water Resources Association
    • /
    • v.51 no.2
    • /
    • pp.165-174
    • /
    • 2018
  • The model using time series data can be considered as a flood forecasting model of a small river due to its efficiency for model development and the advantage of rapid simulation for securing predicted time when reliable data are obtained. Transfer Function Noise (TFN) model has been applied hourly flood forecast in Italy, and UK since 1970s, while it has mainly been used for long-term simulations in daily or monthly basis in Korea. Recently, accumulating hydrological data with good quality have made it possible to simulate hourly flood prediction. The purpose of this study is to assess the TFN model applicability that can reflect exogenous variables by combining dynamic system and error term to reduce prediction error for tributary rivers. TFN model with hourly data had better results than result from Storage Function Model (SFM), according to the flood events. And it is expected to expand to similar sized streams in the future.

A Performance Evaluation of Governmental Funding Projects for IT Small and Medium-Sized Enterprises and Venture Business Using DEA/AR-I (DEA/AR-I을 활용한 IT 중소.벤처기업 정부자금지원정책 성과평가)

  • Park, Sung-Min;Kim, Heon
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.32 no.12B
    • /
    • pp.815-825
    • /
    • 2007
  • It is necessary to establish a systematic framework where the performance of governmental funding projects can be evaluated just-in-time as well as objectively regarding IT small and medium-sized enterprises and venture business. In this study, a framework is proposed for the performance evaluation using Data Envelopment Analysis (DEA) and a case study is illustrated with an empirical dataset. Especially, in order to enhance the reliability of optimal solutions, a DEA/AR-I revised model is developed by adding Acceptance Region (AR) Type I constraints into the DEA basic model. Based on the procedure and the models, it is considered that an 'efficiency score' can be calculated as a guideline for conducting successive performance evaluation processes fast. As for major governmental funding projects with respect to 'IT SMERP 2010 Plan', performance evaluations are discussed concerning between projects as well as between corporate entities within each project.

Analysis of Soil Resistance on Laterally Loaded Piles Considering Soil Continuity (지반의 연속성을 고려한 말뚝의 수평지반저항력 산정)

  • Kim, Young-Ho;Jeong, Sang-Seom
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.30 no.4C
    • /
    • pp.175-183
    • /
    • 2010
  • The load distribution and deflection of large diameter piles are investigated by lateral load transfer method (p-y curve). The emphasis is on the effect of the soil continuity in a laterally loaded pile using 3D finite element analysis. A framework for determining a p-y curve is calculated based on the surrounding soil stress. The parametric studies that take into account the soil continuity are also presented in this paper. Through comparisons with results of field load tests, it is found that the prediction by the present approach is in good agreement with the general trend observed by in situ measurements and thus, represents a significant improvement in the prediction of a laterally loaded pile behavior. Therefore, a present study considering the soil continuity would be more economical pile design.