• Title/Summary/Keyword: 식수공급시설

Search Result 22, Processing Time 0.032 seconds

Analysis of Local Resident'S Perception on 'Rainwater for Drinking' Project in Developing Countries : Focusing on Vietnam Case Studies (개발도상국의 빗물식수화시설 사업에 대한 지역주민의 인식 분석 : 베트남 사례를 중심으로)

  • Lee, Minju;Han, Mooyoung
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.39 no.1
    • /
    • pp.1-8
    • /
    • 2017
  • Drinking water deficiency is prevalent in developing countries due to contamination of surface and ground water, difficulties of water treatment, and lack of water infrastructures. 'Rainwater For Drinking (RFD)' projects are emerging as one of the effective solutions globally since RFD systems provide safe drinking water from rainwater. In RFD projects, perception of local residents toward RFD project is essential as local residents must manage their RFD systems on their own after the project finishes. This research performed survey and interview to 209 local residents, who use RFD systems, and analyzed their general perception, expected effects and feared factors toward RFD projects. Through the research, it was shown that the most of the local residents have positive perception towards RFD projects' effectiveness (41.9%) and are willing to participate (58.9%). The top three expected effect factors of the RFD projects were 'supply of safe water source', 'vitalization of local community', and 'expansion of RFD system'. The top three feared factors were 'quality of rainwater', 'technical factors of RFD system', and 'maintenance of RFD system'. The research findings indicate that development of simple water quality measuring device and education of the local residents about RFD system is necessary for better maintenance of the RFD system after the project finishes.

수질관리를 위한 채수에 대하여

  • Hulsman, A.D.
    • 수도
    • /
    • s.42
    • /
    • pp.26-30
    • /
    • 1988
  • 식수공급시설 및 설비에 있어서의 수질변화를 측정하는데 필요한 시료의 수는 공급시설 및 설비의 분포상태에 좌우된다. 또한 수리적 상황 (hydraulic circumstances)의 변동에 따라 특정 항목 값이 달라지는 지역에 특별히 주의할 필요가 있다. 유통과정에서의 수질변화를 알아내기 위해서는, 통상적으로 사용하고 있는 수도물에 대해 분석을 하여야 하며, 수중의 용해 중금속에 대해서는 표준화된 방법으로 측정하여야 한다. 네덜란드는 급수전에서의 수질에 대한 수질지침이 없으므로 이를 추가적으로 확보할 필요가 있다. 상수의 생산에서 소비에 이르기까지의 기간은 시간적 제약을 받는 것이므로 소비자들은 가정내 상수시설물을 사용하는데에 있어서 이 지침을 따르는 것이 좋다.

  • PDF

Research on Standards for Emergency Water Supply (비상급수시설 급수소요량 기준 개선 연구)

  • Lee, Joon-Hak
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2021.06a
    • /
    • pp.471-471
    • /
    • 2021
  • 비상급수시설은 상수도 공급이 중단될 경우에 국민들에게 최소한의 음용수와 생활용수를 안정적으로 공급하기 위한 시설이다. 2018년 기준으로 상수도 보급을 통한 국내 1인 1일 급수량은 평균 348리터로 나타났지만, 국내 민방위 비상급수시설의 급수소요량은 성인 기준 1명당 25리터를 기준으로 하고 있다. 이것은 식수 9리터와 생활용수 16리터를 포함한 값이다. 그러나 왜 식수 기준을 9리터로 했는지, 생활용수 16리터로 쓸 수 있는 물 사용의 범위가 어디까지인지에 대한 구체적인 내용은 명확하지 않은 실태이다. 본 연구는 국내 민방위 비상급수시설의 급수소요량 기준을 검토하기 위한 것으로 UN, WHO, 유럽, 미국 등의 비상급수와 관련되 음용수 및 생활용수 기준을 수집하고 이를 비교 검토하였다. 그 결과 국내 민방위 비상급수시설의 급수소요량 기준이 선진국보다 적게 산정되어 있음을 알 수 있었으며, 포로수용소의 지속가능 급수지원 기준량보다도 낮은 것을 알 수 있었다. 본 연구에서는 문헌조사를 토대로 음용수, 요리, 세면, 세탁 등을 포함하여 지속가능한 적정 급수소요량 기준을 최소 50리터 이상으로 제안하였다. 한국의 경제력과 국민들의 복지를 고려할 때, 향후 민방위 비상급수시설의 급수소요량 기준을 현재보다 상향 조정하는 것이 타당함을 알 수 있었다.

  • PDF

Status and Improvement Method of Water supply Facilities at Islands of the southwest sea area (서남권 도서지역의 상수원 현황과 문제점 및 개선방안)

  • Park, S.H;Jo, K.S;Lee, H.B;Nam, T.K;Kim, J.S
    • Proceedings of KOSOMES biannual meeting
    • /
    • 2005.05a
    • /
    • pp.175-177
    • /
    • 2005
  • 본 연구는 도서지방에 식수를 안정적으로 공급하기 위하여 도서별 특성에 적합한 최적의 상수원 방안을 마련하는데 목적이 있다. 특히 도서지역은 지형적인 특정상 상수원 확보를 위한 저수지 건설의 적지가 드물고 이상 가뭄과 환경오염으로 물 부족 현상이 심화되고 있으므로 도서지방의 안정적인 식수 공급 방안 수립은 시급한 실정이다.

  • PDF

웃음 꽃피우는 협회: KAHP 해외 속으로(2) -수단 정수시설 완공식 주협흡충 퇴치사업 성공을 위하여

  • Jeong, Hu-Geun
    • 건강소식
    • /
    • v.35 no.3
    • /
    • pp.40-41
    • /
    • 2011
  • 한국건강관리협회는 외교통상부와 한국국제협력단(KOICA)으로부터 '국제빈곤퇴치기여금'을 지원받아 2009년 8월부터 201년 6월까지 2년간 정부 무상원조지원사업으로 수단 화이트나일주(州) 알자발라인 지역의 주혈흡충퇴치사업을 실시하고 있다. 이번 국제빈곤퇴치기여금으로 지원한 식수공급 정수시설은 수단 지역의 날씨와 백나일강의 주변 환경을 고려한 것으로, 물을 취수하는 취수장이 강폭과 깊이, 건기와 우기 등에 영향을 받지 않고 안정적이고 깨끗한 물을 취수 정수하여 공급할 수 있는 화이트나일에서 최고의 시설이다.

  • PDF

생생 아이디어 - 마을상수도 무동력 소독장치

  • 한국상하수도협회
    • 한국상하수도협회지
    • /
    • s.29
    • /
    • pp.24-25
    • /
    • 2010
  • 마을상수도는 상수도가 공급되지 않는 농어촌지역 주민들의 편의를 위하여 제공하는 수도의 형태로, 현재 2만3천여 개의 간이급수시설이 설치 운영되고 있다. 농어촌지역 주민들의 유일한 식수 및 생활용수원으로 사용되기 때문에 관리와 운영에 문제가 발생하면 해당지역 주민들의 건강이나 생활에 직접적인 영향을 미치게 된다. 따라서 마을상수도의 안전성 확보는 농어촌지역 주민들의 건강한 삶을 유지하기 위해 반드시 이루어져야 하는 중요한 사안이다.

  • PDF

Assessment of Food Service Management at Childcare Facilities According to the Number of People Eating Meals (식수인원에 따른 보육시설 급식소 위생관리 수준 평가)

  • Dong Soo Kim;Hyuk Sung Kwon;Pyeong Won Kim;Ja Yeong Lee;Sang Gu Kim;Sang Yun Lee
    • Journal of Food Hygiene and Safety
    • /
    • v.39 no.1
    • /
    • pp.26-34
    • /
    • 2024
  • In this study, the food service management levels of cafeterias in childcare facilities were investigated based on the number of meal recipients and the working status of the kitchen staff. The study included 199 childcare facilities nationwide that received food supplies from the food ingredients distribution company, Pulmuone Foodmerce, from 2021 to 2022. The assessment was conducted using 61 inspection items. The analysis revealed that, as the number of meal recipients and kitchen staff members decreased, the documentation of inspection results was less likely to be conducted (P<0.05). Facilities with fewer meal recipients showed less adequate health status checks for kitchen staff, and those with fewer kitchen staff showed insufficient compliance with hygienic clothing (P<0.05). Additionally, facilities with fewer meal recipients showed a higher frequency of lapses in checking the expiration dates of stored ingredients (P<0.05), requiring increased management attention. They also exhibited the absence of internal temperature measurement records during heating processes (P<0.05). Furthermore, facilities with fewer meal recipients demonstrated inadequate maintenance of kitchen facilities (P<0.05). Significantly higher adenosine triphosphate (ATP) levels were detected on the hands and cutting boards of the kitchen staff in facilities with fewer meal recipients and fewer kitchen staff (P>0.05). Overall, facilities with fewer meal recipients exhibited insufficient infrastructure management for kitchen operations and inadequate hygiene management. These results are expected to provide foundational data for the selection of national support programs for childcare facilities in the future.

Application Methods of Smart Water Grid to Small Municipalities in Nepal (네팔 소도시 내 스마트워터그리드의 적용 방안)

  • Jang, Dong Woo;Choi, Gye Woon;Park, Hyo Seon
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2019.05a
    • /
    • pp.2-2
    • /
    • 2019
  • 네팔의 경우 상하수도를 비롯한 기본적인 위생시설이 크게 미비하며 수도인 카트만두조차 수십 년 된 노후관로가 상수관으로 이용되고 있다. 또한, 하수처리 시설이 사실상 전무하며, 지하수를 주요 수원으로 활용하는 대다수 지역은 식수의 오염에 따른 수인성 전염병에 취약한 실정이다. 따라서 네팔에서는 깨끗한 물과 안정적인 수도공급, 하수처리 시설의 확보가 무엇보다 중요한 과제이며, 이에 스마트워터그리드 기술의 도입을 통한 수질개선, 안정적인 수도공급방안이 요구되고 있다. 본 연구에서는 국내에서 개발된 스마트워터그리드 기술을 네팔 소도시에 적용하기 위한 방법론을 제안하였다. 네팔 소도시의 수자원 및 상수도 시설을 답사하여 문제점을 파악하고, 시설 및 운영현황을 분석하였다. 현장조사 자료를 기반으로 스마트워터그리드 기술의 적용 방향과 단기 및 중장기 계획을 제시하였다. 또한, 네팔 소도시 중 하나인 Beni시를 시범지역으로 하여 과거 30년 동안 월 강수량 기반의 가뭄지수를 분석하고, EPANET을 통하여 상수관망해석을 실시였다. 연구 결과, 가뭄의 발생횟수가 점차 빈번해지는 것으로 나타났으며, 상수관망 해석 시 대부분의 수요절점 내 수압이 설계기준보다 낮은 것으로 모의되었고, 향후 관 노후화를 고려한 절점 수압의 확보와 수질개선 방안이 제시될 필요가 있는 것으로 나타났다.

  • PDF

Development of an Algorithm for Intellectual Control System of Desalination Plants (해수담수화시설의 지능적 운영을 위한 알고리즘 개발)

  • Park, Hyunki;Lee, Dongseop;Han, Kukheon;Kim, Jaeho
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2016.05a
    • /
    • pp.522-522
    • /
    • 2016
  • 우리나라의 488개 유인도 중 강수량 부족 혹은 지하수의 수질문제 등으로 상습적 식수난을 겪고 있는 도서지역은 237개에 이르고 있다. 이들 도서지역은 생활용수를 우물, 간이상수도, 운반급수 등에 의존하고 있지만 이중 47%의 도서는 간이급수시설이 전무한 실정이다. 2015년에는 인천시 옹진군의 소청도, 대청도에 장기간 지속된 가뭄으로 식수원이 고갈되어 3일에 1시간으로 급수를 제한하였고 이로 인해 식수난 문제 외 관광산업의 소득저하 등의 문제가 발생되어 원활한 물공급문제가 해결되지 않으면 도서지역의 위기는 심각할 것으로 우려된다. 도서지역의 기본권인 먹는 물 문제를 해결하기 위해 정부 및 지자체에서는 소규모 유인도서에 해수담수화시설을 설치하여 유지관리 및 운영을 위한 인력을 배치하고 수동으로 조작하거나 단순 자동운전에 의해 운영 및 관리되고 있는 실정이다. 본 연구에서는 해수담수화시설의 안정적이고 효율적인 운영을 위해 지능적 수운영 알고리즘을 개발하였다. 제어시스템, 감시시스템, 계측시스템 등의 ICT 기술과 연계하여 수요를 정확히 예측하고, 실시간 전력비용과 저류량, 사용량 등을 통합적으로 고려하였으며 적시정량을 생산하여 저장 및 공급하며, 목표수질과 수량을 원활하고 안정적으로 공급할 수 있도록 제어 및 감시를 통한 지능적 수운영을 목적으로 연구하였다. 데이터의 수집과 전송, 분석, 제어, 감시 활동이 유기적으로 결합되어 용수의 생산과 분배, 공급활동을 자동화함으로 운영상의 리스크를 줄여주며, 필요시 통합운영센터에서의 의사결정을 지원할 수 있도록 개발하였다. 향후, 해수담수화시설뿐이 아닌 일반 상수도 수운영에 있어서의 취수, 도수, 정수, 배수지관리, 송수, 관망관리까지 자동화된 시스템을 개발하여 지능적 운영관리가 가능하도록 알고리즘 모델 및 프로그램을 제시하고자 한다.

  • PDF