• Title/Summary/Keyword: 식립 위치

Search Result 158, Processing Time 0.03 seconds

The use of surgical guide stent for implant placement (임플란트 식립을 위한 수술 가이드의 사용)

  • Lee, Ji-Yeon;Yoon, Ji-Young;Oh, Namsik
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.52 no.4
    • /
    • pp.366-375
    • /
    • 2014
  • Surgical guide not only provide diagnosis and treatment plan, but even location and direction of implantation. Surgical guide could be divided into non-limited design, partially limited design, and completely limited design. Partially limited design is easily manufactured and inexpensive but less accuracy, compared to completely limited design. From this approach, partially limited design may be particularly effective in patients who present with a single missing tooth or partially edentulous teeth. Completely limited design is anatomically accuracy, esthetical and functional, optimized treatment for prosthetic and biomechanical perspective, and also minimizes discomfort for post-treatment. The purpose of this study is to review previous studies of various surgical guides and applying in clinic.

디지털 가이드 시스템과 사전 제작된 임플란트 상부보철물을 이용한 전치부의 임플란트 수복 : 증례보고

  • Choi, Yongkwan
    • Journal of the Korean Academy of Esthetic Dentistry
    • /
    • v.30 no.1
    • /
    • pp.24-32
    • /
    • 2021
  • Dental implant have been in use for a long time to restore at missing tooth. But, To place dental implant at good position very is difficult. Improperly positioned dental implants make some problems to have a good function of dental implant. so, To place dental implant at accurate position is the most important step throughout the whole process. Digital guided system of dental implant is very useful to have a accurate position of dental implant and it makes upper restoration more esthetic and funcional.

Anatomic study of the incisive canal in relation to midpalatal placement of mini-implant (정중구개부의 미니 임플랜트 식립과 관련된 절치관의 해부학적 연구)

  • Kim, Sung-Jin;Lim, Sung-Hoon
    • The korean journal of orthodontics
    • /
    • v.39 no.3
    • /
    • pp.146-158
    • /
    • 2009
  • Objective: The purpose of this study was to reveal the position of the incisive foramen in relation to the incisive papilla and cusp tips. Methods: Plaster models and CT images of 25 adult orthodontic patients were used to measure the width of the incisive canal and positions of the anterior and posterior borders of the incisive foramen in relation to the incisive papilla. Results: The palatal surface distance from the interdental papilla between the maxillary central incisors to the posterior border of the incisive foramen along the palatal surface was 1.7 fold of the distance from the interdental papilla between the central incisors to the posterior border of the incisive papilla. The distance between the posterior border of the incisive papilla and posterior border of the incisive foramen along the palatal surface was 6.15 ${\pm}$ 1.75 mm. The anteroposterior position of the posterior border of the incisive foramen was slightly anterior to the lingual cusp tips of the maxillary 1st premolars. The width of the incisive foramen was 4.03 ${\pm}$ 0.64 mm, therefore it is recommended to position the mini-implant more than 3 mm laterally when placing a mini-implant lateral to the incisive foramen, from the center. Conclusions: These results can be used as a reference in presuming the position of the incisive foramen when placing mini-implant in the anterior palate area.

Rehabilitation with implant-supported fixed dental prostheses using digital duplication technique on customized artificial tooth, interim denture and implant surgical template: A case report (디지털 복제로 만든 맞춤형 인공치로 제작한 임시의치와 임플란트 수술용 템플릿을 통한 임플란트 지지형 고정성 보철 수복 증례)

  • Jeong, Dae Gil;Oh, Kyung Chul;Shim, June Sung;Park, Ji-Man
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.57 no.4
    • /
    • pp.397-404
    • /
    • 2019
  • Bone and soft tissue conditions are important for successful implant treatment. But, the placement itself is also very important. Implants which is installed in the wrong position result in the biological, esthetical and mechanical problems. In order to place an implant in the correct position, the final restoration and diagnostic wax-up should be considered prior to the surgery. If the artificial teeth for the interim denture are directly transferred from the diagnostic wax-up, the operator can try the form of diagnostic wax-up in the mouth. If the surgical template is produced by duplicating the interim denture, the implant can be placed in the planned position. In this case, the polymethyl methacrylate (PMMA) artificial tooth was precisely milled by the digital duplication of diagnostic wax-up. And interim denture was fabricated by using these milled teeth. After the patient adapted for a sufficient period, the implant was placed at the planned position with surgical template produced by duplicating the interim denture. After confirming sufficient osseointegration, the final prostheses were made to reflect the shape of diagnostic wax-up. Through this procedure, the satisfactory functional and esthetic outcome could be acquired.

Esthetic implant restoration in the maxillary anterior missing area with palatal defect of the alveolar bone: a case report (구개부 치조골 결손을 보이는 상악 전치 상실부의 임플란트 심미보철수복: 증례보고)

  • Oh, Jae-Ho;Kang, Min-Gu;Lee, Jeong-Jin;Kim, Kyoung-A;Seo, Jae-Min
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.33 no.4
    • /
    • pp.291-298
    • /
    • 2017
  • It is challenging to produce esthetic implant restoration in the narrow anterior maxilla region where insufficient volume of alveolar bone could limit the angle and position of implant fixture, if preceding bone augmentation is not considered. Ideal angle and position of implant fixture placement should be established to reproduce harmonious emergence profile with marginal gingiva of implant prosthesis, bone augmentation considered to be preceded before implant placement occasionally. In this case, preceding bone augmentation has been operated before esthetic implant prosthesis in narrow anterior maxilla region. Preceded excessive bone augmentation in buccal area allowed proper angulation of implantation, which compensates unfavorable implant position. Provisional restorations were corrected during sufficient period to make harmonious level of marginal gingiva and interdental papilla. The definite restoration was fabricated using zirconia core based glass ceramic. Functionally and esthetically satisfactory results were obtained.

Flapless implant surgery on atrophied alveolar ridge in a patient with growth disorder (성장 장애를 가진 부분 무치악 환자에서 위축된 골에 무피판 임플란트 수술 증례)

  • Lee, Du-Hyeong
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.30 no.2
    • /
    • pp.170-175
    • /
    • 2014
  • The growth disorder influences craniofacial development and early loss of permanent teeth. This case reports the importance of computerized tomography (CT) and surgical guide to identify horizontal bone loss, adjacent teeth and to guide drills when placing implants in a short stature patient. The patient has idiopathic short stature and the 3rd grade of intellectual disability. To recover posterior mandibular teeth, implant treatment was planned. CT images showed that the adjacent teeth were located markedly to the buccal side. A CT-based surgical guide was fabricated and implants was placed using flapless surgery. Bone dehiscence and fenestration may happen when the surgical guide was fabricated just based on adjacent clinical crowns. Thus, it is essential to analysis bone and teeth and to make surgical guide through CT, especially in atrophied bone on grow disorder patients. Furthermore, systematic researches are recommended to elucidate the relationship between growth disorder and tooth malposition.

The effects of local factors on the survival of dental implants: A 19 year retrospective study (임플란트의 생존율에 영향을 미치는 국소적 인자에 대한 19년간의 후향적 연구)

  • Kim, Sung-Hoi;Kim, Sun-Jai;Lee, Keun-Woo;Han, Dong-Hoo
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.48 no.1
    • /
    • pp.28-40
    • /
    • 2010
  • Purpose: The aim of this retrospective study was to provide long-term data about the correlation between multifactorial local factors and the survival of implants. Material and methods: During 19 years (1991 to 2009), 2796 implants were placed in 879 patients. From dental charts and radiographs, the following data were collected: patient's age at implant placement, gender, implant system, surface, length, diameter, location of implant placement, bone quality, primary stability, type of prosthesis. The correlations between these data and implant survival were analyzed. Statistical analysis was performed using Kaplan-Meier survival analysis, Chi-square test, odds ratio. Results: 1. Among the 2796 implants, 150 implants failed that resulted in a cumulative survival rate of 94.64%. The cumulative survival rate of smooth surface implants (91.76%) was lower than rough surface implants (96.02%). 2. Anatomic location, implant surface, diameter of smooth surface implant, primary stability, type of prosthesis, patient's age and gender were significantly associated with implant survival (P < .05). 3. No significant difference in implant survival was found in relation to the following factors: implant length, bone quality, diameter of rough surface implants and type of rough surface according to implant manufacturer (P < .05). Conclusions: Local factors such as anatomic location, implant surface, diameter of smooth surface implant, primary stability and type of prosthesis have a significant effect on implant survival.

Deviations of Implant Position between Pre- and Post-operation in Computer-guided Template-based Implant Placement (Computer-guided template를 이용한 임플란트 식립에서 술 전과 술 후 사이의 임플란트 위치에 따른 변위량 검사)

  • Kim, Won;Kim, Seung-Mi;Kim, Hyo-Jung;Song, Eun-Young;Lee, Si-Ho;Oh, Nam-Sik
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.27 no.2
    • /
    • pp.175-184
    • /
    • 2011
  • With a development of implant restoration technique, there are increasing use of computer-guided system for edentulous patients. It was carried out simulated operation based on CT information about patient's bone quantity, quality and anatomical landmark. However, there are some difference between the programmed implant and post-operative implant about it's position. If the deviation was severe, it could happen a failure of 'passive fit' and not suited for path of implant restoration. The aim of this presentation is to evaluate about a degree of deviations between programmed implant and post-operative implant. Five patients treated by 'NobelGuide' system (Nobel Biocare AB, G$\ddot{o}$teborg, Sweden) in Department of Prosthodontics, Inha University were included in this study. The patients were performed CT radiograph taking and intra-oral impression taking at pre-operation. Based on CT images and study model, surgical stent was produced by NobelBiocareTM. To fabricated a pre-operative study model, after connected lab analog to surgical template, accomplished a pre-operative model using type 4 dental stone. At final impression, a post-operative study model was fabricated in the conventional procedures. Each study model was performed CT radiograph taking. Based on CT images, each implant was simulated in three dimensional position using $Procera^{(R)}$ software (Procera Software Clinical Design Premium, version 1.5; Nobel Biocare AB). In 3D simulated model, length and angulation between each implant of both pre- and post-operative implants were measured and recorded about linear and angular deviation between pre-and post-operative implants. A total of 24 implants were included in this study and 58 inter-implant sites between each implant were measured about linear and angular deviations. In the linear deviation a mean deviation of 0.41 mm (range 0~1.7 mm) was reported. In the angular deviation, a mean deviation was $1.99^{\circ}$ (range $0^{\circ}{\sim}6.7^{\circ}$). It appears that the both linear and angular mean deviation value were well acceptable to application of computer-guided implant system.

전치부 임플란트의 심미적 수복

  • Lee, Seo-Yeong;Ryu, Jae-Jun
    • Journal of the Korean Academy of Esthetic Dentistry
    • /
    • v.18 no.1
    • /
    • pp.27-32
    • /
    • 2009
  • 오늘날 단일치 임플란트의 식립은 현재 시행되고 있는 가장 일반적인 임플란트 술식 중 하나이며, 상악 전치부는 이중 가장 흔하게 시행되는 식립 부위 중하나이다. 그럼에도 불구하고 상악 전치부 단일 상실치에 대한 치료 계획은 구강 내 다른 어떤 부위보다 복잡하며 고도로 심미성을 요구하는 부위로서 아무리 경험이 많고 기술이 뛰어난 치과의사라 할지라도 시술할 때마다 큰 도전으로 여겨지는 경우가 대부분일 것이다. 상악 전치부에서 임플란트 보철의 심미적 성공을 이루기 위해서는 모든 구성 요소 하나하나에서 심미적 결과를 이룩하여야 하고 이 결과들이 완벽하게 조화를 이루게 하여야 하며 이는 결코 쉬운 일이 아닐 것이다. 시술 시 교과서의 그림처럼, 모형에 식립해 본 것처럼 쉽게 되지 않는 것은 물론 구강 내 환경이 모형과 다를 리 만무한 것이 당연한 첫 번째 이유이며 뿐만 아니라 환자 대부분의 경우 모형처럼 완벽한 경 연조직이 갖추어진 상태에서 치아만 상실된 경우는 거의 찾아볼 수 없기 때문인 이유도 크다. 즉, 원하는 위치에 식립을 하고 장기간의 심미적 유지를 위해서는 경 연조직에 대한 처치가 필수적인 경우가 대부분이라는 이야기이다. 이를 간과하고 식립한 경우 추후 심각한 bone의 resorption, 그에 따르는 gingiva의 끔찍한 recession, 용납할 수 없는 비심미적 보철물의 제작은 불을 보듯 뻔한 결과가 될 것이다. 따라서 상악 전치부 식립 치료계획 시 치과의사는 성공적 결과에 영향을 미칠 수 있는 모든 요소에 촉각을 곤두세우고 이들의 완벽한 처치에 최선을 다 해야할 것이다.

  • PDF

A Study on Titanium Miniscrew as Orthodontic Anchorage : An experimental investigation in dogs (성견에서 교정적 고정원으로서의 티타늄 미니스크류에 대한 연구)

  • Yoon, Byung-Soo;Choi, Byung-Ho;Lee, Won-You;Kim, Kyoung-Nam;Shim, Hyung-Bo;Park, Jin-Hyung
    • The korean journal of orthodontics
    • /
    • v.31 no.5 s.88
    • /
    • pp.517-523
    • /
    • 2001
  • Titanium miniscrews we being used increasingly as an anchorage for tooth movement, because they ate easy to place and to remove, increase the number of sites available, give minimum strain to patients regarding surgical procedures, and offer uneventful healing alter removal. The use of titanium miniscrews as an orthodontic anchorage has been reported in clinical case reports, but clinicians have experienced screw loosening when using such screws.' To our knowledge, there are no published reports evaluating the stability of miniscrews. Information about the length of miniscrews used in relation to the location is of some importance, as stability will vary depending on bone duality The purpose of this study was to evaluate a variety of Lengths of miniscrews (dimeter: 2mm) which were inserted in maxilla or mandible and to demonstrate in a dog model which miniscrew provides fundamental stability in the jaws. 10 mm long miniscrews in the maxilla and 8mm long: miniscrews in the mandible showed no clinical mobility and retained their position throughout an 8 weeks force (200g) application. The mucosal condition around the screws was healthy in cases in which miniserews were inserted in the alveolar bone between the roots and the head of the screws emerged into the attached gingiva. When the force application was terminated, radiographic analysis revealed neither rent resorption not periodontal pathology around the miniscrews that remained stable during the entire treatment period. This study suggests that if titanium miniscrews with adequate length are properly used depending on the location, they provide sufficient stability for orthodontic anchorage.

  • PDF