• Title/Summary/Keyword: 시험온도 조건

Search Result 1,074, Processing Time 0.035 seconds

Critical Temperature for Early Marginal Transplanting of Japonica Rice in Korea (우리나라 자포니카 벼 품종의 조기이앙 한계온도 분석)

  • Woonho Yang;Shingu Kang;Dae-Woo Lee;Mi-Jin Chae
    • KOREAN JOURNAL OF CROP SCIENCE
    • /
    • v.68 no.4
    • /
    • pp.246-261
    • /
    • 2023
  • We investigated critical temperature for early marginal transplanting (CT-EMT) of the contemporary japonica rice varieties in Korea through the field, pot seedling tray, and the phytotron experiments during 2020 to 2023. The lowest mean temperature for 10 days from transplanting (MT-10DFT) that resulted in earlier heading date was 12.4℃ and the highest MT-10DFT that did not show the earlier heading date was 12.0℃ in the field study when the MT-10DFT varied by changing transplanting date. The lowest MT-10DFT that induced the increased biomass but not the earlier heading date was 11.6℃ and the highest MT-10DFT that showed neither the increased biomass nor the earlier heading date was 11.4℃. Compared to the 10-day later transplanting, the dates of the first root development, initiation of the chlorophyll recovery, and the first tiller development were earlier when the MT-10DFT was 9.1℃ or higher, 10.5℃ or higher, and 11.6℃ or higher, respectively, in the pot seedling tray and field experiments. The earliness of the first tiller development was a practical index for the estimation of CT-EMT during the early growth stage of rice. The response of transplanted rice to temperature treatments with the diurnal change of 10℃ in the phytotron study was similar to that shown in the field study. The data shown for constant temperature without a diurnal change revealed that the extent of positive effects of high temperature at day-time was greater than the extent of negative effects of low temperature at night-time on the early growth of transplanted rice. It was concluded that the critical MT-10DFT for early marginal transplanting of japonica rice in the temperate environments was between 11.4 to 11.6℃ based on the plant growth and between 12.0 to 12.4℃ based on the plant development.

Developmantal Characteristics and Host Preference of Parasitic Natural Enemy, Binodoxys communis (Gahan) (Hymenoptera: Braconidae) (기생성 천적 쌍꼬리진디벌(Binodoxys communis Gahan)의 발육 특성 및 기주선호성)

  • Park, Bueyong;Lee, Sang-Guei;Kim, Gil-Hah
    • Korean journal of applied entomology
    • /
    • v.60 no.3
    • /
    • pp.277-286
    • /
    • 2021
  • The natural enemy was identified as a parasitic wasp, Binodoxys communis Gahan. B. communis taxonomically belongs to the family braconidae, subfamily aphidinae, and genera binodoxys. It develops normally at 17.5 to 32.5℃, and not at 35℃. Depending on the temperature, the longest development period of B. communis was 21.9 days at 17.5℃, and shortest was 6.46 days at 32.5℃. The effective accumulated temperature was 175.44 DD for females as well as males; however, the developmental threshold temperature was 10.87℃ and 10.74℃ for females and males, respectively. This parasitic wasp was found to prefer cotton aphids and soybean aphids as its prey.

Mechanical Properties According to Curing Conditions of Mortar Using CO2 Hardening Cement (CO2 반응경화 시멘트 활용 모르타르의 양생조건에 따른 역학적 특성)

  • Ji-Seok Seo;Sun-Gyu Tae;Jun Lee;Bong-Chun Lee
    • Journal of the Korean Recycled Construction Resources Institute
    • /
    • v.11 no.4
    • /
    • pp.307-315
    • /
    • 2023
  • In this study, mortar test specimens were produced by varying the mixing ratio of CO2 reaction hardening cement (CSC) and general cement (OPC), and the mechanical and carbonation characteristics were evaluated by controlling the primary curing temperature and secondary curing CO2 pressure. Under all curing conditions, it was observed that the higher the CSC ratio in the binder, the lower the mechanical properties. Specifically, a first curing temperature of 60 ℃ yielded higher mechanical properties compared to the case of 20 ℃, and a greater carbonation penetration depth was also observed. At a first curing temperature of 60 ℃, it was noted that the curing pressure and bending strength during the second CO2 curing were inversely proportional, while the compressive strength showed a proportional relationship. This phenomenon is believed to be due to excessive carbonation, which reduces mechanical properties, and the fact that flexural strength is more sensitive to these properties compared to compressive strength. However, based on the evaluation of the limited curing conditions, it is evident that future test conditions need to be expanded and reviewed more thoroughly.

Study on the Characteristics of Far Infrared Ray Drying for Rough Rice(III) - Performance test of far infrared ray dryer - (벼의 원적외선 건조특성에 관한 연구(III) 원적외선 건조기 성능시험)

  • 김유호;조영길;조광환;이선호;김영민;한충수;금동혁;한종규
    • Proceedings of the Korean Society for Agricultural Machinery Conference
    • /
    • 2003.07a
    • /
    • pp.213-219
    • /
    • 2003
  • 본 연구에서는 새로운 개념의 건조방법을 연구하여 곡물건조의 변화를 도모하고자 원적외선ㆍ열풍 복합열을 이용한 곡물건조기를 개발하게 되었다. 그 결과를 요약하면 다음과 같다. 가. 방사체길이가 1,680mm일 때 보다 1,470mm일 때가 방사체 표면온도가 높게 나타났고, 안정적인 것으로 나타났다. 열풍온도를 5$0^{\circ}C$로 설정했을 때 방사체의 표면온도분포는 280-29$0^{\circ}C$을 유지하였고, 6$0^{\circ}C$일 때는 30$0^{\circ}C$ 부근에서 유지되는 것을 확인할 수 있었다. 두 조건 모두에서 온도편차는 크게 나타나지 않았으므로 균일 건조가 이루어지는 것을 의미하며, 곡물의 품질저하에 영향을 미치지 않는 것으로 판단된다. 나. 열풍온도 5$0^{\circ}C$, 조사거리 125mm, 방사체 길이 1,470mm에서 방사체 길이방향으로 위치에 따라서 온도편차를 측정했을 때 버너를 기점으로 해서 근거리에서부터 원거리까지 균등 분할하여 5점의 온도를 측정하여 그 변화곡선을 분석한 결과 위치 3에서 온도가 높았고, 계속해서 위치 4, 5, 2, 1순으로 나타났다. 버너의 근거리에서보다 원거리에서 온도가 높게 나타난 것은 원적외선방사체를 통과하는 열풍이 빠져나가도록 되어있는 열풍유동관이 버너 원거리에 위치하고 있어 버너에 불꽃이 점화되면서 열풍이 방사체 끝쪽으로 유동되기 때문이다. 다. 건조실 수직면 길이방향의 온도는 열풍공기가 열풍실에서 유입되는 하단부이 온도가 높게 나타났고, 버너쪽과 송풍기쪽의 온도차는 나타나지 않아 온도분포의 좌우 대칭이 잘 되어 균일 건조가 되는 것으로 판단된다 이러한 현상은 건조실의 수평면에 대해서도 같은 현상이 나타났다. 라. 바닥면에서 상부로 올라갈수록 낮은 온도분포를 나타내고 있는 것은 상부에는 외부공기가 유입되면서 온도가 떨어지는 반면 하부에는 외부공기 유입이 적기 때문으로 사료된다. 또한 열풍실의 길이방향 위치별 온도 분포에서도 같은 현상으로 나타났고, 버너쪽과 송풍기쪽의 온도편차는 나타나지 않아 균일 건조를 기대할 수 있다. 마. 열풍온도를 45$^{\circ}C$로 설정하고 조사거리와 방사체 길이를 각각 119, 1,470mm로 하여 벼의 건조성능시험을 열풍건조기(대비구)와 비교시험 결과 시험구에서 건감률, 건조소요에너지가 각각 0.58%(w.b.), 470kcal/kg - water로 대비구보다 각각 건감율은 23% 높았고, 건조소요에너지는 2%의 절감되었다. 바. 건조기에서 발생되는 소음은 버너쪽 근처에서는 대비구 94.12㏈의 87%에 불과하였으나, 거리가 멀어질수록 차이는 크지 않았다. 이것은 버너에서 멀어질수록 외부적인 요인이 소음에 영향을 미쳤기 때문인 것으로 생각된다. 사. 시작기와 대비구간의 경제성에서 시작기의 구입가격이 20% 비싸기 때문에 시간당 고정비가 높았으나, 건조성능이 우수하여 건조비용이 69,350원/톤으로 대비구보다 14% 절감되는 것으로 나타났다.

  • PDF

Fundamentals of Ecotoxicity Evaluation Methods using Domestic Aquatic Organisms in Korea : (I) Fish (국내 생물종을 이용한 생태독성평가 기반연구 : (I) 어류)

  • Nam, Sun-Hwa;Yang, Chang-Yong;An, Youn-Joo;Lee, Jae-Kwan
    • Korean Journal of Ecology and Environment
    • /
    • v.40 no.2
    • /
    • pp.173-183
    • /
    • 2007
  • The Ministry of Environment plans to introduce the Whole Effluent Toxicity (WET) system in Korea. The WET test is well established in developed countries with recognizing of the limitations of physicochemical analysis method and potential risk of chemicals in water medium. Therefore, it is essential to build the ecotoxicity infrastructure for the induction of WET test. In this study, we extensively collected the domestic and foreign toxicity test methods which employ native test species to Korea. And we suggested that the domestic ecotoxicity test methods with domestic test species in Korea through extracting the range of test conditions. Five domestic fish species selected were Carassiu auratus (Crucian carp), Cyprinus carpio(Common carp), Gasterosteus aculeatus (Three spine stickleback), Misgurnus anguillicaudatus (Oriental weather fish) and Oryzias latipes (Japanese medaka), The toxicity test methods with native test species to Korea were collected from the standard methods (OECD, U.S. EPA, ASTM), government reports, SCI papers and domestic papers. We collected the 32 test methods, and suggested the suitable aquatic toxicity test methods for fish. It is expected that this study could prove a useful information to establish the ecotoxicity test methods with domestic aquatic organisms in Korea henceforth.

A Study on Shear Characteristics of a Rock Discontinuity under Various Thermal, Hydraulic and Mechanical Conditions (다양한 열-수리-역학적 조건 하에서 불연속면 전단 거동 특성에 관한 실험적 연구)

  • Kim, Taehyun;Jeon, Seokwon
    • Tunnel and Underground Space
    • /
    • v.26 no.2
    • /
    • pp.68-86
    • /
    • 2016
  • Understanding the frictional properties of rock discontinuities is crucial to ensure the stability of underground structures. In particular, the frictional behavior at depth depends on the complex interaction among mechanical, hydraulic, thermal and chemical characteristics and their coupled effects. In this study, a series of shear tests were carried out in a triaxial compression chamber to investigate the shearing behavior of saw-cut granite surface and rough shear surface of synthetic rocks. The test results were analyzed using Coulomb's shear strength criterion. The frictional behavior of saw-cut granite surface showed little variation at different confining, water pressures and temperature conditions, however in case of synthetic rocks, the frictional behavior showed different trend depending on normal stress level. In addition, the variation of stiffness and dilation at different testing conditions were analyzed, and the stiffness and dilation showed little variation at different water pressures and temperature conditions.

Fuel-Rich Combustion Characteristic of a Combined Gas Generator (혼합식 가스발생기의 연료과농 연소특성)

  • Lee, Dongeun;Lee, Changjin
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.43 no.7
    • /
    • pp.593-600
    • /
    • 2015
  • In this study, a combined hybrid rocket system is newly introduced which has characteristics of both gas generators and afterburner type hybrid rockets. In particular, a combined gas generator utilizing solid fuel and liquid/gas oxidizer was designed as a primary combustor of the system. Combustion tests were carried out with various equivalence ratio affected by parameters such as fuel length, oxidizer flow rate, fuel port diameter and fuel type. In general, fuel-rich gas generator produces low combustion gas temperature to meet the temperature requirement and the target temperature was transiently set less than 1600 K. Since it was found that controlling parameters showed limited effects on the change of equivalence ratio, mixture of $O_2$ and $N_2$ as an oxidizer was additionally introduced. As a result, a combined gas generator successfully produced combustion gas temperature of less than 1600 K Future studies will carry out more combustion tests to attain fuel-rich combustion gas temperature less than 1200 K, which was a temperature requirement of a gas generator system in the previous studies.

A Study on the Thermal Crack Control of the In-Ground LNG Storage Tank as Super Massive Structures (지하식 LNG 저장탱크 구조물의 온도균열 제어에 관한 연구)

  • Kwon, Yeong-Ho
    • Journal of the Korea Concrete Institute
    • /
    • v.23 no.6
    • /
    • pp.773-780
    • /
    • 2011
  • In this study, thermal stress analysis are carried out considering material properties, curing condition, ambient temperature, and casting date of the mass concrete placed in bottom slab and side wall of the in-ground type LNG tank as a super massive structure. Also, based on the numerical results, cracking possibility is predicted and counter measures to prevent the cracking are proposed. For the tasks, two optimum mix proportions were selected. From the results of the thermal stress analysis, the through crack index of 1.2 was satisfied for separately caste concrete lots except for the bottom slab caste in 2 separate sequences. For the double caste bottom slab, it is necessary introduce counter measures such as pre-cooling prior to the site construction. Also, another crack preventive measure is to lower the initial casting temperature by $25^{\circ}C$ or less to satisfy 1.2 through crack index criterion. In the $1^{st}$ and $2^{nd}$ caste bottom slab, the surface crack index was over 1.2. Therefore, the surface cracks can be controlled by implementing the curing conditions proposed in this study. Since the side wall's surface crack index was over 1.0, it is safe to assume that the counter preventive measures can control width and number of cracks.

Prediction of Long-term Viscoelastic Performance of PET Film Using RH-DMA (RH-DMA를 적용한 PET 필름의 장기 점탄성 성능 예측)

  • Choi, Sun Ho;Yoon, Sung Ho
    • Composites Research
    • /
    • v.32 no.6
    • /
    • pp.382-387
    • /
    • 2019
  • A single frequency strain mode test, a stress relaxation mode test, and a creep test using RH-DMA were performed to investigate the effects of relative humidity and temperature on the viscous properties of PET film. The relative humidity was 10%, 30%, 50%, 70%, and 90%. The temperature was considered to be 30~95℃ for single frequency strain mode tests, 30℃ and 70℃ for stress relaxation mode test, and 5~95℃ for creep test. According to the results, higher relative humidity results in lower storage modulus and loss modulus, but the maximum value of the loss modulus is not significantly affected by changes in relative humidity and is almost constant. Relaxation modulus decreases rapidly at the beginning and becomes constant, and as the temperature increases, it is susceptible to changes in relative humidity. Strain recovery also increases rapidly at the beginning and is susceptible to changes in relative humidity as the temperature increases. In addition, as the temperature increases, the degree of increase in creep compliance increases, and as the temperature rises above the glass transfer temperature, the degree of increase becomes very large. The master curve determined by the time-temperature superposition provides the information to predict the long-term performance under operating conditions such as relative humidity and temperature.

Effect of Confining Pressure, Temperature, and Porosity on Permeability of Daejeon Granite: Experimental Study (대전 화강암의 투수계수에 미치는 구속압, 온도, 공극률의 영향: 실험적 연구)

  • Donggil Lee;Seokwon Jeon
    • Tunnel and Underground Space
    • /
    • v.34 no.1
    • /
    • pp.71-87
    • /
    • 2024
  • In deep geological disposal of high-level radioactive waste, the surrounding rock at the immediate vicinity of the deposition hole may experience localized changes in permeability due to in-situ stress at depth, swelling pressure from resaturated bentonite buffer, and the heat generated from the decay of radioactive isotopes. In this study, experimental data on changes in permeability of granite, a promising candidate rock type in South Korea, were obtained by applying various confining pressures and temperature conditions expected in the actual disposal environment. By conducting the permeability test on KURT granite specimens under three or more hydrostatic pressure conditions, the relation in which the permeability decreases exponentially as the confining pressure increases was derived. The temperature-induced changes in permeability were found to be negligible at temperatures below the expected maximum of 90℃. In addition, by establishing a relation in which the initial permeability is proportional to the power of the initial porosity, it was possible to estimate permeability value for granite with a specific porosity under a certain confining pressure.