• Title/Summary/Keyword: 시험기관

Search Result 1,138, Processing Time 0.028 seconds

A Machine-to-machine based Intelligent Walking Assistance System for Visually Impaired Person (시각장애인을 위한 M2M 기반의 지능형 보행보조시스템)

  • Kang, Chang-Soon;Jo, Hwa-Seop;Kim, Byung-Hee
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.36 no.3B
    • /
    • pp.287-296
    • /
    • 2011
  • The white stick mainly used for visually impaired person has difficulty in providing location information and effective countermeasures for emergency situations encountered during walking as well as detecting floating obstacles on the ground. In this paper, we propose a machine-to-machine based intelligent walking assistance system for safe and convenient walking of the visually impaired. The proposed system consists of a walking assistance stick used by the visually impaired and a server supporting multiple stick users in remote places through mobile communication networks. The stick equipped with ultrasonic sensors, GPS(global positioning system) receiver and vibrator not only detects floating obstacles, but also offers stick users with present location identification utilizing a text-to-voice conversion technology. Besides providing geographic information, the server notifies the emergency locations of users to guardian and aid agency, and it provides log information during walking such as the place, time and the number of accidents. Test results with a developed prototype system have shown that the system properly performs the functions and satisfies overall system performance.

Attack and Defense Plan, Attack Scenarios on Voice of Internet Protocol (인터넷전화의 공격 시나리오 및 공격과 방어 방안)

  • Chun, Woo-Sung;Park, Dea-Woo;Chang, Young-Hyun
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2011.10a
    • /
    • pp.245-248
    • /
    • 2011
  • Voice over Internet protocol(VoIP) is call's contents using the existing internet. Thus, in common with the Internet service has the same vulnerability. In addition, unlike traditional PSTN remotely without physical access to hack through the eavesdropping is possible. Cyber terrorism by anti-state groups take place when the agency's computer network and telephone system at the same time work is likely to get upset. In this paper is penetration testing for security threats(Call interception, eavesdropping, misuse of services) set out in the NIS in the VoIP. In addition, scenario writing and penetration testing, hacking through the Voice over Internet protocol at the examination center will study discovered vulnerabilities. Vulnerability discovered in Voice over Internet protocol presents an attack and defense plan.

  • PDF

Development of FPGA Based HIL Simulator for PMS Performance Verification of Natural Liquefied Gas Carriers (액화천연가스운반선의 PMS 성능 검증을 위한 FPGA 기반 HIL 시뮬레이터 개발)

  • Lee, Kwangkook
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.22 no.7
    • /
    • pp.949-955
    • /
    • 2018
  • Hardware-in-the-loop (HIL) simulation is a technique that can be employed for developing and testing complex real-time embedded systems. HIL simulation provides an effective platform for verifying power management system (PMS) performance of liquefied natural gas carriers, which are high value-added vessels such as offshore plants. However, HIL tests conducted by research institutes, including domestic shipyards, can be protracted. To address the said issue, this study proposes a field programmable gate array (FPGA) based PMS-HIL simulator that comprises a power supply, consumer, control console, and main switchboard. The proposed HIL simulation platform incorporated actual equipment data while conducting load sharing PMS tests. The proposed system was verified through symmetric, asymmetric, and fixed load sharing tests. The proposed system can thus potentially replace the standard factory acceptance tests. Furthermore, the proposed simulator can be helpful in developing additional systems for vessel automation and autonomous operation, including the development of energy management systems.

Growth Stages of Maize (Zea mays, L.) (옥수수의 형태적 변화와 생장 발육 단계)

  • 박병훈;양종성;강정훈
    • KOREAN JOURNAL OF CROP SCIENCE
    • /
    • v.26 no.2
    • /
    • pp.185-191
    • /
    • 1981
  • The purpose of this paper is to define and describe a series of growth stages for maize. cv. MTC-l (early) and Suweon No. 19 (late) that are easily identifiable by both professional agronomists and farmers. Plants were grown at a density of 60cm row with plant spacing of 15cm at six different seeding times in 1980. Leaf development indices with ten grades (LDI) were identified and defined in accordance with the development of a leaf blade. Leaf appearance rate (LAR) was ca. 3 days and it was not influenced by the variety or seeding time. The elongation of the first internode above the ground level began in a month after emergence and it corresponded to the 8th or 9th leaf stage. Internodes elongated in regular sequence of node position. The morphological change of silks related closely with the development of kernel. The duration of generative development was not influenced by varieties and seeding time but that of vegetative growth was influenced. A new scheme for the maize which was made by the developed leaves, visible nodes above ground level, morphological change of silks and development of kernel was proposed.

  • PDF

The Analysis of On-line Contents Application for Effective Operating Extra-Curriculum in ACHS (방송고 특별활동의 효과적인 운영을 위한 콘텐츠 적용 분석)

  • Chung, Jong-In;Jeong, Young-Sik;Kim, Mee-Yong
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.10 no.8
    • /
    • pp.2078-2087
    • /
    • 2009
  • The Air and Correspondence High School (ACHS) has played a key role as an organization of lifelong learning since 1974. However, extra-curriculum in ACHS has not been operated successfully due to lacks of educational supports and on-line contents. So we surveyed demands of the ACHS teachers and students for successful operation of extra-curriculum, found four subjects that students preferred in the developing activity area which is one of extra-curricular activities, and experimentally developed four on-line contents for extra-curriculum. And we also applied the developed on-line contents to the students of Chongju H.S. After the application, another survey and interview were carried out to measure learner's satisfaction, find out problems of learning with on-line contents and suggest the ways of improving extra-curriculum learning system.

Design of Uni-directional Optical Communication Structure Satisfying Defense-In-Depth Characteristics against Cyber Attack (사이버공격에 대비한 심층방호 특성을 만족하는 단방향 광통신 구조 설계)

  • Jeong, Kwang Il;Lee, Joon Ku;Park, Geun Ok
    • KIPS Transactions on Computer and Communication Systems
    • /
    • v.2 no.12
    • /
    • pp.561-568
    • /
    • 2013
  • Instrumentation and control system in nuclear power plant performs protecting, controling and monitoring safety operation of Nuclear Power Plant. As cyber attack to the control equipment of instrumentation and control system can cause reactor shutdown and radiation release, it is required to design the instrumentation and control system considering cyber security in accordance with regulatory guides and industrial standards. In this paper, we proposed a design method of uni-directional communication structure which is required in the design of defense-in-depth model according to regulatory guides and industrial standards and we implemented a communication board with the proposed method. This communication board was tested in various test environments and test items and we concluded it can provide uni-directional communication structure required to design of defense-in-depth model against cyber attack by analyzing the results. The proposed method and implemented communication board were applied in the design of SMART (system-integrated modular advanced reactor) I&C (instrumentation and control) systems.

Analysis of Dynamic Characteristics and Performance of Solenoid Valve for Pressurization Propellant Tank (추진제탱크 가압용 솔레노이드밸브의 작동특성 분석 및 해석)

  • Jang, Jesun;Kim, Byunghun;Han, Sangyeop
    • Journal of the Korean Society of Propulsion Engineers
    • /
    • v.17 no.2
    • /
    • pp.128-134
    • /
    • 2013
  • A 2-way solenoid valve regulates to maintain the pressure of ullage volume of propellant tanks when the command is given by control system for the liquid-propellant feeding system of space launch vehicle. The simulation model of solenoid valve for pressurization is designed with AMESim to verify the designs and evaluate the dynamic characteristics and pneumatic behaviors of valve. To improve the accuracy of the model, numerical flow analysis by using FLUNET code. The simulation results of their operating durations of valve by AMESim analysis are matched up with the results of experiments and validate valve model. Using the model, we analyze performance of valve; opening/closing pressure, operating time on various design factors of basic valve and control valve; geometrical size of valve seat, ratio of basic valve and sealing area.

Analysis of Boundary Layer in Solid Rocket Nozzle and Numerical Analysis of Thermal Response of Carbon/Phenolic using Finite Difference Method (고체 로켓 노즐의 경계층 해석과 유한차분법을 이용한 탄소/페놀릭의 열반응 해석 연구)

  • Seo, Sang Kyu;Hahm, Hee Cheol;Kang, Yoon Goo
    • Journal of the Korean Society of Propulsion Engineers
    • /
    • v.22 no.1
    • /
    • pp.36-44
    • /
    • 2018
  • The thermal response of carbon/phenolic used in a solid rocket nozzle liner was analyzed. In this paper, the numerical analysis of the thermal response of carbon/phenolic consists of (1) the integration equation of the boundary layer to obtain the convective heat transfer coefficient of the combustion gas on the rocket nozzle wall and (2) 1-D finite difference method for heat conduction of carbon/phenolic to calculate the ablation, char, and temperature. The calculated result was compared with the result of a blast-tube-type test motor. It is found that the calculated result shows good agreement with the thermal response of the test motor, except at the vicinity of the throat insert.

Measurement of Performance of High Speed Underwater Vehicle with Solid Rocket Motor(II) (로켓추진을 이용한 고속 수중운동체의 수중 주행성능 측정 결과(II))

  • Yoon, Hyun-Gull;Lee, Hoy-Nam;Cha, Jung-Min;Lim, Seol;Suh, Suhk-Hoon
    • Journal of the Korean Society of Propulsion Engineers
    • /
    • v.22 no.4
    • /
    • pp.12-17
    • /
    • 2018
  • A natural cavitation-type high-speed underwater vehicle with solid rocket motor is tested, and its speed and running distance are measured. The outputs from pressure sensors on the surface of the vehicle reveal a pressure-time history reflecting the development of supercavitation. Underwater cameras installed on the wall of the test pool record the entire process from the onset of supercavitation to its full development. CNU-SuperCT, based on two-dimensional inviscid theoretical analysis, is used to simulate test results. Considering CNU-SuperCT does not include the control fins of the vehicle, simulation results agree with test results very well. Additionally, pictures from underwater cameras support the test results.

Reviewing of Operating Stability about Pulse Detonation Engine's Ignition Circuit to the Type of Power Sources (점화 신호 종류에 따른 PDE 점화회로의 작동 안정성 연구)

  • Kim, Jungmin;Han, Hyung-Seok;Oh, Sejong;Choi, Jeong-Yeol
    • Journal of the Korean Society of Propulsion Engineers
    • /
    • v.22 no.6
    • /
    • pp.11-18
    • /
    • 2018
  • A pulse detonation engine (PDE) requires high operating frequency greater than 100 Hz to get meaning thrust as a propulsion devise. Thus a PDE needs an ignition circuit operating precisely at high operating frequencies. In this paper AC(alternating current) and DC(direct current) types of ignition circuits were designed and compared. Each circuit was tested at operating frequencies from 16.66 to 100.00 Hz by measuring the input signal of each circuit and the voltage change in the primary coil of the transformer. Results show that the DC power circuit can attain a maximum error rate of 5.15% at higher operating frequencies, whereas the AC power circuit displays a negligible agreement with the operating signal at frequencies greater than 33.33 Hz. Therefore it is confirmed that DC-powered ignition circuit is preferable for the PDE operating at high frequencies.