Study on the Necessity of T.A.B for Ventilation and Safety facilities of Road Tunnel (도로터널 환기 및 방재시설 T.A.B의 필요성에 관한 연구)

  • Yeo, In-Chul;Kang, Byung-Ho
    • Proceedings of the SAREK Conference
    • /
    • 2005.11a
    • /
    • pp.75-81
    • /
    • 2005
  • The Necessity of TAB for the facilities of Ventilation and Safety system in a road tunnel is studied. TAB is to test, adjust and balance a system. The study is to investigate the advantage which results from carrying out TAB, with the measurement of temperature, velocity and pressure. The method of measurement of these factors and TAB procedure are a]so explained.

  • PDF

기획특집 - T.A.B. 수행절차 및 수행 계획

  • An, Jeong-Ho
    • 월간 기계설비
    • /
    • s.232
    • /
    • pp.50-70
    • /
    • 2009
  • T.A.B란 공기조화설비에 대한 종합시험조정으로 시험, 조정 및 균형(Testing, Adjusting & Balancing)이라는 뜻이다. 이는 설계 목적에 부합되도록 모든 빌딩의 환경시스템을 검토하고, 조정하는 과정이다. 따라서 T.A.B기술은 공기 및 물이라는 유체의 흐름과 온 습도에 관련된 분야이기 때문에 시각적으로 그 성과를 알아보기 힘들고, T.A.B를 적용한 후 결과치를 정밀 분석해 판단할 수 있으며 T.A.B기술을 적용하지 않은 건물과 간접비교하는 방법으로 그 효과를 쉽게 알 수 있다. T.A.B기술을 적용할 경우 시공 중인 건물에 설계도서가 완료되기 전, 또는 장비의 구매발주 전에 T.A.B측면에서 모든 기술 도서를 면밀히 검토하게 된다. 그 중 일부에서 발견되는 문제점들 즉, 적정치 못한 용량 선정, 시스템 구성상 미비점, 불필요한 장비 선정, 누락 사항을 발견할 수 있다. 따라서 T.A.B 기술을 적용할 경우 향상된 품질의 시공이 가능해 준공 후 빈번히 대두되는 하자 문제가 현격히 줄게 되며 또한 운전경비 절감, 쾌적한 실내환경 조성, 장비수명 연장 등 효율적인 운전관리 효과를 얻을 수 있다. 우리나라 공기조화설비기술은 꾸준한 발전을 이루었고, 최근에는 도입 초기단계시 전혀 고려되지 않던 공조공간의 쾌적성 및 소음 방지 대책 등의 문제가 주요사항으로 부각되고 있다. 이에 따라 공조설비에 T.A.B실행의 표준화 정착과정에 있으며, 국내 학계 및 연구기관에서 공조설비에 대한 연구 및 T.A.B용역업체의 기술축적 등 T.A.B분야 발전을 위해 노력하고 있다. 본지는 T.A.B의 수행절차 및 수행계획, TAB 수행업체 등에 대해 알아본다.

  • PDF

The study on relation between ocular function and accommodative facility (시기능과 조절 용이성과의 관계 연구)

  • Park, Hyun-Ju
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.10 no.4
    • /
    • pp.375-380
    • /
    • 2005
  • To assess convergence and accommodation at a short distance, 92 selected subjects without any ocular diseases by apperatuses of visual chart(Shinnippon CT30) and phoropter(Shinnippon VT 10) at a short distance(40 cm) were tested upon MEM retinoscopy(Welch Allyn, USA). BELL retinoscopy(Welch Allyn, USA), binocular accommodative facility (${\pm}2.00$ D flipper. Bernell Co., USA), vergence facility(prism flipper, Bernell Co., USA). There were such test results as MEM retinoscopy(R/L)($+1.05{\pm}0.87/1.02{\pm}0.80$ D). BELL retinoscopy ($17.89{\pm}12.12/17.94{\pm}11.72cm$), binocular accommodative facility (R/G)($7.69{\pm}6.48cpm$). binocular accommodative facility(polaroid)($11.76{\pm}5.22cpm$), monocular accommodative facility(R/L) ($13.9{\pm}6.27/13.8{\pm}5.96cpm$), vergence facility($13.5{\pm}6.40cpm$).

  • PDF

Laboratory Assessment of Geotextile Tube for Dewatering High Water Content Material (고함수비물질의 탈수에 대한 지오텍스타일 튜브의 실험적 평가)

  • Mo, Xinghua;Kim Tae-Hyung;Moo-Young. Horace K
    • Journal of the Korean Geotechnical Society
    • /
    • v.18 no.5
    • /
    • pp.261-269
    • /
    • 2002
  • The objectives of this paper are to study the use of geotextile tribes for dewatering high water content sludges and sediments and to evaluate their feasibility and affecting fsctors. To accomplish these objectives, pressure filtration tests were conducted on woven geotextile (Geotex$\circledR$ 46T and 1212T) fir high water content materials with a modified experimental apparatus. Test results indicate that 1) the filter cake formed on the inside of the geotextile tube is the major contributor to the retention of fine particles, but also causes a decrease in permeability, 2) controlling the formation of the filter cake and thus achieving a balance between soil retention and permeability is vital to a successful project, and 3) geotextiles, sludge properties, and filtration pressures have some effects on the dewatering efficiency and dewatering rate.

Clinical Estimation of Corrected State with Change in Vertex Distance (정점간거리 변화에 따른 교정상태의 임상 평가)

  • Kim, Jung-Hee;Lee, Hak-Jun
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.15 no.1
    • /
    • pp.25-30
    • /
    • 2010
  • Purpose: This study was conducted to estimate the changes of corrected diopter and corrected visual acuity with the change in vertex distance. Also we aimed to provide basic data for refraction test. Methods: Using the trial lens, we measured the corrected diopter and corrected visual acuity after performing binocular balance test. We measured the changes of corrected diopter and corrected visual acuity in change of vertex distance. We analyzed statistical significance and relations between vertex distance and corrected diopter and corrected visual acuity. Results: There was no difference in corrected diopter with the change of vertex distance within -1.00D, but the corrected diopter increased with it over - 1.25D. In particular, the change of diopter was largest when the vertex distance increased 15 mm. At over 11.00D, there was large changes of diopter with the changes of vertex distance at 5 mm, 10 mm and 15 mm. On correlation analysis between the vertex distance and the corrected diopter, there was strong correlation (r=0.999 at 5 mm increase of vertex distance, r=0.982 at 10 mm increase and r=0.957 at 15 mm increase) and also there was significant (p<0.01). At the change of visual acuity in increased of vertex distance, the range of a decrease in visual acuity was large when the changes of vertex distance was largest. On correlation analysis between the vertex distance and the corrected visual acuity, there was strong correlation (r=0.969 at 5 mm increase of vertex distance, r=0.985 at 10 mm increase and r=0.994 at 15 mm increase) and also there was significant (p<0.01). Conclusions: The vertex distance was very important at the refraction test and at wearing spectacle. On correlation analysis between the vertex distance and the corrected diopter, and the corrected visual acuity, there was strong correlation and statistically significant. Therefore, the vertex distance should be kept at the refraction using trial lens, and the best fitting was made not to slipping forward, and so we suggested regular refitting of spectacle and the managing method of spectacle were educated to the spectacle wearers.

Effect of Probiotics on Risk Factors for Human Disease: A Review (인간 질병의 위험 요인에 대한 Probiotics의 효과: 총설)

  • Chon, Jung-Whan;Kim, Dong-Hyeon;Kim, Hyun-Sook;Kim, Hong-Seok;Hwang, Dae-Geun;Song, Kwang-Young;Yim, Jin-Hyuk;Choi, Dasom;Lim, Jong-Soo;Seo, Kun-Ho
    • Journal of Dairy Science and Biotechnology
    • /
    • v.32 no.1
    • /
    • pp.17-29
    • /
    • 2014
  • GRAS probiotics can be used to modulate intestinal microbiota and to alleviate various gastrointestinal disorders. In several recent studies, researchers have explored the potential expansion and usability of probiotics to reduce the risk factors associated with diseases, including obesity, hypercholesterolemia, arterial hypertension, hyperhomocysteinemia, and oxidative stress. In this review, our aim was to clarify the mechanism underlying interactions between hosts (animal or human) and probiotics and the beneficial effects of probiotics on human health.

  • PDF