• Title/Summary/Keyword: 시편

Search Result 4,684, Processing Time 0.026 seconds

A Study on the Warpage in Injection Molded Part for Various Part Designs and Non Reinforced Resins (비 보강 수지의 종류와 사출성형품의 설계에 따른 휨의 연구)

  • Lee, M.;Kim, J.H.;Park, S.R.;Lyu, M.Y.
    • Elastomers and Composites
    • /
    • v.44 no.4
    • /
    • pp.373-377
    • /
    • 2009
  • Most of the plastics products are being manufactured by injection molding. Warpage in injection molded affects the product dimension and it causes assembling problem. In this study, warpages in the injection molded part been studied. Specimens are rectangular flat shapes with and without ribs. Amorphous polymers (PC and ABS) and crystalline polymers (PP and PA66) were used for material. Flat shape with ribs showed higher warpage than flat shape without ribs by 6 to 9%. The specimens with ribs that are located parallel to the flow direction has higher warpage than specimens with ribs that are located perpendicular to the flow direction by 25 to 39%. Crystalline polymers have higher warpage than amorphous polymers by 23 to 67%. Warpage decreases as packing time increases and it increases as injection temperature increases.

A Study on Solidification and Wear Character of Multi-alloyed White Cast Iron

  • Yu, Sung-Kon;Matsubara, Yasuhiro
    • Journal of Korea Foundry Society
    • /
    • v.20 no.4
    • /
    • pp.260-268
    • /
    • 2000
  • 응고 및 마모거동을 연구하기 위하여 Cr, V, Mo 및 W의 조성이 다른 3종류의 백주철을 주조하였다. 고주파유도용해로에서 장입시켜 1873K까지 승온시켜 장입원료들을 모두 용해시킨 후 1823K에서 Y블럭주형에 주입하였다. 얻어진 3종류의 백주철조성은 다음과 같다: Fe-3%C-10%Cr-5%Mo-5%W(합금1), Fe-3%C-10%V-5%Mo-5%W(합금2) 및 Fe-3%C-17%Cr-3%V(합금 3)응고과정을 추적하기 위하여 각 시편으로부터 50g을 채취한 후 알루미나도가니에 넣고 실리콘카바이드로를 사용하여 1723K의 알콘분위기하에서 재용해를 시켰다. 용금을 10K/분의 속도로 냉각시키면서 열분석을 행하였으며 도중 몇 차례 소입 실험을 병행하였다.합금1의 경우 초정오스테나이트, (오스테나이트+$M_7C_3$)공정, (오스테나이트+$M_6C$)공정, 합금2의 경우 초정 MC, 초정오스테나이트, (오스테나이트+MC)공정 , (오스테나이트+$M_2C$)공정, 합금3의 경우 초정 $M7C_3$와 (오스테나이트+$M_7C_3$)공정으로 구성되어 있었다. 주방상태, 균질화열처러상태, 공냉상태, 템퍼링상태에서 내마모시험을 행하였다. 먼저 주방상태시 편을 진공분위기하에서 1223K에서 5시간동안 균질화열처리를 행한후 로냉을 시켰다. 다시 이 시편을 1323K에서 2시간 유지후 강제공냉을 시켰으며 강제공냉된 시편을 573K에서 3시간동안 템퍼링처리를 하였다. 내마모시험은 120 mesh마모지에 10N의 하중을 가하여 실시하였다. 각 사이클마다 무게감소를 측정하였으며 8번 반복실험을 하였다. 마모량은 균질화열처리시편, 주방상태시편, 템퍼링시편, 공냉시편의 순으로 감소하였다. 합금2가 마모량이 가장 적었으며 합금3이 가장 많았다. 합금2의 마모량이 가장 적은 이유는 조직이 초정 MC, 공정 MC 및 공정 M2C로 구성되어 있기 때문으로 사료된다.주방상태에서 기지조직은 퍼얼라이트이었으나 열처리를 통하여 마르텐사이트, 템퍼드마르텐사이트, 잔류오스테나이트로 변태하였다. 이상의 결과를 종합해 보면 MC가 내마모성에 가장 기여하는 조직으로 판단되어진다.

  • PDF

Size Effects on the Compressive Strength of Composite Plates with an Open Hole (홀을 갖는 복합재 적층판의 압축강도에 대한 크기 효과에 관한 연구)

  • ;;;C. Soutis
    • Journal of the Korean Society of Propulsion Engineers
    • /
    • v.5 no.1
    • /
    • pp.42-48
    • /
    • 2001
  • Over two decades, many researchers have performed studies on strength size effects in composite laminates under tensile and flexural loads. It is well known that there is a tendency for the strength of fibre-reinforced composites to decrease with increasing specimen size. Under compressive load, however, little work has been done on the effect of specimen size to failure strength. This is due to the fact that compressive testing of composite is very difficult. In this paper, the effect of the test specimen size on the compressive strength of composites containing open hole was considered using T300/924C, $>[45/-45/0/90]_{3S}$. For sizing test specimens, the in-plane scaling method is used i.e., the change of two- dimensional specimen area in specimen width and gauge length. The results clearly show that there is a hole size effect in the finite width plates. In addition, the specimens which have the same a/W(hole diameter/specimen width) exhibit a tendency of size effect. In contrast, test results of the unnotched specimens did not show a clear strength size effect.

  • PDF

Stress Distribution Study along Shear Test Specimen Shape for Bonding Strength Verification between Glass and Metal (금속-유리 간 접착강도 검증을 위한 전단시험 시편형상에 따른 응력분포 연구)

  • Kim, Hye-Sung
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.50 no.7
    • /
    • pp.455-463
    • /
    • 2022
  • As the need for R&D for high reliability cameras, such as satellite cameras, increases, the reliability of the bonding strength properties between an opto-mechanical structure and an optical component has been secured through specimen tests. However, the widely used specimen shape is not suitable for the application of glass and glass-ceramic material, which is fragile, making it difficult to obtain accurate bonding properties due to stress concentration in glass parts before reaching the bonding strength limit. In this study, the stress distribution characteristics in the shear test condition for various specimen shapes were studied analytically, based on the test results of the glass material's own fracture. Through this, the shape characteristics capable of relieving the stress concentration of the glass part were derived, and the range of the bonding shear strength verifiable by the specimen test was improved.

A Study on the Manufacturing Processability of Automatic Winding Device for Manufacturing Strand Specimens (스트랜드 시편 제작 장치의 제작 공정성 연구)

  • Cha, Jae Ho;Jang, Jeong Keun;Lee, Bo Mi;Yoon, Sung Ho
    • Composites Research
    • /
    • v.33 no.5
    • /
    • pp.315-320
    • /
    • 2020
  • In this study, when strand specimens were manufactured using an automatic winding device to obtain uniform strand specimens, analysis and test were conducted to investigate the effect of thermal expansion of the mandrel on strand specimens. Also, necessity of changing materials and mandrel configuration was checked. According to the results, strand specimen received unintended tension that was created by thermal expansion of the mandrel and this unintended tension depended on the curing temperature and position of specimens. Tensile test was conducted to check that initial tension affected on the performance of carbon fiber tow prepreg. All other conditions were fixed and only the initial tension was controlled at 40 N, 60 N, and 80 N. From the results of analysis and test, neither additional tension and tension deviation due to the thermal expansion of the mandrel and the initial tension difference had a significant effect on tensile test results, because carbon fiber had sufficiently high strength compared with tension. Therefore, it was confirmed that the change of the mandrel material and configuration of the automatic winding device was unnecessary.

A Study on Temperature Characteristics of Various Depth using Infrared Thermography (적외선 열화상기법을 이용한 균열 깊이에 따른 온도특성에 관한 연구)

  • Jung, Ju-Yeong;Yoon, Hyuk-Jin;Cho, Hyun-Woo;Yang, Hui-Seung
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.19 no.3
    • /
    • pp.83-89
    • /
    • 2018
  • The thermal characteristics of concrete specimens were analyzed using cement paste specimens with artificial cracks. In order to understand the temperature characteristics of the specimen depending on the crack depth, the specimen was heated and the minimum temperatures of the specimens at which cracks appear were investigated according to the crack depth. It was confirmed that the surface temperature distribution of the specimen varies depending on whether the specimen is cracked or not, because of the single and multiple reflections of the incident energy. Furthermore, as the temperature distribution of the specimen reaches a steady state, the temperature data tends to decrease with the crack depth. Through the observation of the normalized temperatures, it was found that the temperature of the specimens obtained from this experiment reached a steady state after 10 minutes. At this time, the standard deviation of the normalized temperature is around 0.01 or less, and the temperature decreases linearly with increasing crack depth. This result is considered to be closely related to the area where multiple reflections occur in the cracked region. If the correlation between the crack region and the incident energy is analyzed for various specimens, it can be applied to the diffuse reflection of the light.

Effects of Temperature on Hardness of Rubber Materials with Different Curing System (가교시스템이 다른 고무재료의 경도에 대한 온도의 영향)

  • Jin, Hyun-Ho;Hong, Chang-Kook;Cho, Dong-Lyun;Kaang, Shin-Young
    • Elastomers and Composites
    • /
    • v.43 no.4
    • /
    • pp.213-220
    • /
    • 2008
  • In this study, the effects of curing system on the hardness of rubber materials at various temperature were investigated. NR and SBR were compounded with various sulfur or peroxide content, in order to obtain various crosslink densities. The changes of hardness and crosslink density were measured as a function of temperature and the relationship was examined. The thermal stresses were also measured in order to investigate the effect of entropy as a function of temperature. The hardness of NR and SBR compounds increased with increasing temperature above room temperature, and the measured thermal stress increased as temperature increased. However, the crosslink densities were not changed by temperature change.

Development of Composite Sr Ferrite EM Wave Absorbers for GHz Frequency (GHz 대역용 복합형 Sr 페라이트 전파 흡수체의 개발)

  • Kim, Dong-Il;Moon, Sang-Hyun;Shin, Sung-Jae;Song, Jae-Man;Kim, Ki-Man
    • Journal of Navigation and Port Research
    • /
    • v.28 no.6
    • /
    • pp.503-507
    • /
    • 2004
  • We prepared EM wave absorbers by using recycled Sr ferrite for GHz frequency, and investigated the effects of carbon additions and preparation temperatures on their EM wave absorption properties. A Sr ferrite EM wave absorber with the ratio of Sr ferrite: silicon rubber: carbon = 80 : 13.6: 6.4 wt% prepared at 7$0^{\circ}C$ showed -24 dB at 9.4 GHz and -23 dB at 5.5 GHz for 2 mm and 3 mm thickness, respectively.

A Study on the Dose Analysis of Pottery Shards by Thermoluminescence Dating Method (TL 연대측정법을 이용한 토기 시편의 선량 분석)

  • Shin, Hyun-Sang
    • Analytical Science and Technology
    • /
    • v.12 no.6
    • /
    • pp.558-564
    • /
    • 1999
  • A method for measuring archaeological dose of Packjae pottery shards using thermoluminescence dosimetry(TLD) has been studied. TL measurement has been achieved using quartz crystals in the size range of 90 to $125{\mu}m$ diameter extracted from the pottery shards. The stable temperature region of the TL glow curve which is devoid of anomalous fading components was identified by the plateau test and found to exist from 265 to $300^{\circ}C$. The archaeological dose of the pottery shards was estimated to be 7.43 Gy using the dose calibration curves obtained from sequential irradiation of $^{137}Cs$ gamma source to the samples and TL measurement of natural samples.

  • PDF

Study on the Coercive Field Strenght Noise Depends on The Magnetic Field Annealing Effect of Amorphous Ribbon (비정질 리본의 자기장중 열처리에 의한 보자력 노이즈의 변화에 관한 연구)

  • 최근화;손대락
    • Journal of the Korean Magnetics Society
    • /
    • v.4 no.2
    • /
    • pp.150-153
    • /
    • 1994
  • Magnetic field annealing method has been used to obtain proper hysteresis loop shapes which are useful to a device using amorphous ribbon. In this study, two pairs of Helmhotz coils were used to apply longitudinal and transverse magnetic field during annealing. For the measurement of coercive field strength noise which depends on magnetic field annealing, Co-based amorphous alloy ribbon $VITROVAC^{\circledR}$ 6030 was used. For the sample which was annealed under dc transverse and dc longitudinal magnetic field, coercive field strength noise was nearly independent of magnetizing frequency ranging from 1 to 100 kHz, but dc transverse and ac longitudinal magnetic fields annealed samples show that the coercive field strength noise decreased in power of magnetizing frequency. When magnetic domain nucleation occurred, the coercive field strength noise increased remarkably and decreased in power of magnetizing frequency.

  • PDF