• Title/Summary/Keyword: 시자각

Search Result 187, Processing Time 0.025 seconds

Subjective Visuoperception to Vertical Yoked Prisms (수직동향프리즘의 자각적 시감각에 관한 연구)

  • Kim, Jae-Do;Kim, Dae-Hyun;Lee, Ik-Han;Kim, Bong-Whan;Kim, Young-Hoon
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.13 no.1
    • /
    • pp.95-99
    • /
    • 2008
  • Purpose: Even refractive error is perfectly corrected by glasses power, the glasses wearer can feel imbalance and uncomfortable by prism effects. The purpose of this study was to investigate subjective imbalance to vertical yoked prism in visually normal subjects. Methods: Visually normal 37 subjects (aged 20 to 31 y) were fully corrected by soft contact lens and worn vertical yoked prism, base up and base down 1, 2, 4, 6, 8 prism diopter(pd) at random order. A rating scale questionnaire was administered to assess quantitatively subjective imbalance to the yoked prism. The near phoria tests were done using Howell-Kim phoria card at 40 cm distance. Results: For the subjective response of imbalance, base up yoked prism was higher than base down yoked prism (t-test: t=4.67, p=0.00) in over 2 prism diopters. The frequency of subjects who feel imbalance by base up vertical yoked prism is higher for near esophoric group than for exophoric group. Conclusions: To reduce subjective imbalance caused by glasses such as dizzy, it needs to make the minimum prism effect, and base down yoked prism is more effective than base up yoked prism in prism effects.

  • PDF

A Comparative Analysis between the Real Body Size and Self-Conceptual Body Size (여대생의 실제계측체형과 자각적 인지체형의 비교분석)

  • Koo, Mi-Ji
    • The Journal of Natural Sciences
    • /
    • v.10 no.1
    • /
    • pp.133-140
    • /
    • 1998
  • The purpose of this study was to analyze the differences between the real body size that had measured and self-conceptual body size. For this, measurements and survey were practiced to 85 subjects who were divided by three groups as the degree of fatness. Followings were the findings of this research: 1)Self-conceptual body size items that were related with clothing size spec expressed the same results with the real body size. 2)Self-conceptual body size items that were not offered the practical information for bo요 size such as height, fatness and length of leg were related with the ideal image that was preferred by subjects.

  • PDF

Clinical Consideration of Visual Fatigue on 3D Images (3D 영상 시청에 대한 시각적 피로도의 임상적 고찰)

  • Kim, Jung-Ho;Son, Jeong-Sik;Park, Sung-Jin;Kwon, Soon-Chul
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.38C no.11
    • /
    • pp.990-999
    • /
    • 2013
  • Previous studies based on the theoretical evidence and based on the empirical data have been constantly revealing related factors affecting visual fatigue in viewing 3D images. however, the measurement data coupled with the factors that affect the viewers to feel fatigue is insufficient. this study research that the viewers feel the visual functional data is based on subjective fatigue such as IPD, AC/A ratio, and the degree of phoria and the effects on variance in these data, is to examine the correlation between these data. based on the average score of subjective fatigue which is $6.00{\pm}3.88$, total fatigue points from 0 up to 6 is classified as a group not appealing for the fatigue and from 7 up to 16, they were classified as the fatigue appealing group. the results showed no difference in satisfaction of the images by each subjective fatigue, IPD and far phoria. AC/A ratio was higher from the fatigue not appealing group, near phoria was higher from the fatigue appealing group. after watching 3D images, the fatigue not appealing group showed a tendency of higher increase of exophoria. correlations appeared in this experiment showed that AC/A ratio and near phoria are closely related to level of subjective fatigue which feel when watching 3D images. when watching 3D images based on two data appear to be able to predict the fatigue, even during content production fatigue reduce the data dimensions to be used as the main basis is expected.

Changes in Subjective Discomfort, Blinking Rate, Lens Centration and the Light Transmittance of Lens Induced by Exceeding Use of Daily Disposable Circle Contact Lenses in Dry Eyes (일회용 써클소프트렌즈의 일일 초과착용 시 유발되는 건성안의 자각적 불편감, 순목횟수, 중심안정 및 렌즈 광투과율의 변화)

  • Park, Mijung;Kang, Shin Young;Chang, Jung Iee;Han, Arum;Kim, So Ra
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.19 no.2
    • /
    • pp.153-162
    • /
    • 2014
  • Purpose: This study was assessed to investigate the change of subjective and/or objective symptoms and the light transmittance of lens caused by the use longer than recommended wearing time of daily disposable circle contact lenses (circle lens) in dry eyes. Methods: Three daily disposable circle lenses made of etafilcon A, hilafilcon B, and nelfilcon A were applied on 30 dry eyes with smaller tear volume than normal eyes in their twenties free from any eye diseases by when subjects complained any kind of discomfort. On the first and the last days of lens wearing, subjective discomfort, blinking rate, lens centration on corneal surface and visible light transmittance of lens were recorded at every case and compared. Results: The circle lens wearers complained subjective discomfort and quit the lens wearing when they wore the circle lens longer than 10 hours even though there were some difference according to the lens materials of daily disposable circle lens. However, around 20% of dry eyes could wear the circle lens made of non-ionic materials longer than 40 hours. Dry eyes showed most sensitive feeling of subjective discomfort against the circle lens made of etafilcon A among three different lens materials. On the last day of lens wearing, the representative subjective discomforts were irritation, stiffness, dryness and tiredness. When the subjects wore circle lens more than the recommended time, blinking rate was significantly increased about 20~30% regardless of lens materials when it compared with the values right after lens wearing. On the last day of lens wearing, the vertical direction of lens centration was shifted to pupil center however, its distribution in horizontal direction was wide compared with the distribution right after lens wearing. Especially, the centration of etafilcon A lens was unstable. Furthermore, the visible light transmittance of 3 different circle lenses in dry eyes has significantly been reduced around 15% averaged. Conclusions: From these results, it was known that the increase of dryness and stiffness caused by overusage of daily disposable circle lens induced excess irritation and decreased visible light transmittance and caused significant more blinking, which provoked lens decentration. It was also revealed that dry eyes showed sensitive reaction subjectively and objectively against the overusage of circle lens made of high water content/ionic lens material even there were some difference of the degree depending on the individual and the lens material. Thus, this research can be suggested as the basic reference for the education about some unexpected problems and the side effect caused by the wearing of circle lens in dry eyes.

A Research on the Health a Condition by T.H.I. at Security Guards and Dept. Security Guard College Students (T.H.I.에 의한 민간 경호경비원과 경호학과 대학생의 건강상태 조사연구)

  • Kim, Jin-Hwan
    • Korean Security Journal
    • /
    • no.12
    • /
    • pp.73-87
    • /
    • 2006
  • This research is for examining the effect on personal health and differences between men and women by health care program in security guards and students, who are specializing security in college, appealing consciousness state physically and mentally. The following results are attained by conducting a questionnaire survey(T.H.I) of 358 men engaged in security guard services and 220 students specializing security (The data analysis is operated by Analysis of Variance(ANOVA) to make a comparative study of health care program, sex distinction and security careers. The implication of the study are as follows. 1. Generally students show less average rate than security guards in appealing the consciousness state especially in Mental Irritability, Irregular Life, Depression, Respiratory, Eyes and Skin, Aggressiveness. 2. In comparing men with women of consciousness state after the step of health care program, men show lower average rate than women except Life Scale and Respiratory. 3. In differences of consciousness state by security career, the more respondents have careers, the less the average rate of Mental Irritability and Depresaion is. But in Life Scale, the result is reverse.

  • PDF

Musculoskeletal Symptoms and Its Related Factors among Male Workers in a Nonferrous Manufacturing Industry (비철금속제조업 생산직 남성 근로자들의 근골격계 자각증상과 관련요인)

  • Jeong, Yeon-Ok;Cho, Young-Chae
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.13 no.8
    • /
    • pp.3552-3560
    • /
    • 2012
  • This study was conducted to find out the complaint rate of musculo-skeletal disorder and its related factors from male manufacturing workers at a nonferrous manufacturing industry. As for the research subjects, 302 workers selected from a nonferrous manufacturer located in Daejeon City, and as for the collection of data, a standardized anonymous questionnaire survey were conducted from May 1, 2011 to June 30, 2011. As a results, the complaint rate of musculo-skeletal disorders by each body part, the symptom of shoulders was 42.7%, the highest rate, followed by the waist, 36.8%, the neck and the hand/wrist/finger, 30.5% respectively, the leg and foot, 30.1% and arm/elbow, 20.9%. The complaint rate of musculo-skeletal disorder for the sociodemographic characteristics was significantly high as survey participants' age and BMI were low and in the group having low subjective health condition. The complaint rate of musculo-skeletal disorder for the health-related behavior characteristics was significantly high in the group having been absent from work due for diseases, in the group having received outpatient services, in the group having been hospitalized for treatment, in the group not having a regular exercise and in the group having insufficient sleeping hours. Finally, the complaint rate of musculo-skeletal disorder for the job-related characteristics was significantly high in the group suffering from the physical burden of their work, in the group working while bending at the waist and in the group carrying out repetitive tasks.

Subjective Symptoms according to Fitting Test in Soft Contact Lens Wearers (소프트콘택트렌즈 착용자의 피팅 상태 확인 유무에 따른 자각적 증상)

  • Kim, Jung-Hee;An, Youngju
    • The Korean Journal of Vision Science
    • /
    • v.20 no.4
    • /
    • pp.431-442
    • /
    • 2018
  • Purpose : The purpose of this study was to investigate subjective symptoms according to the wearing, purchase and fitting status of soft contact lens wearers, and consumer perception of base curve. Methods : A survey was conducted for those who visited optical shops and lens shops in Seoul from June to August 2018. A total of 98 answer sheets they submitted were used for the analysis. The chi-square test and Fisher's exact test were used to compare subjective symptoms (dryness, glare, uncomfortable fitting, and decreased vision) according to whether fitting condition is screened (case history and push-up test, ect relevant to wearing sensation), and the odds ratio (OR) was obtained by the logistic regression analysis. Results : When the contact lenses were purchased, the rate of which the visual acuity test was performed was 86.6% at optical shop and 64.7% at lens shop. When purchasing contact lens and the contact lens was not tested for fitting, they more experienced dryness (OR 4.41, 95% CI 1.25-15.62) and uncomfortable fitting (OR 2.68, 95% CI 1.08-6.64) than testing for fitting. In addition, it was investigated that 87.8% of contact lens wearers did not know about the term base curve, 92.9% did not listen to an explanation related to the base curve when purchasing contact lenses, and 96.9% did not experience with base curve test. Conclusion : It would be thought that satisfaction of the contact lens fitting of existing consumers should be improved by changing a proper base curve by confirming the fitting condition when prescribing soft contact lens.

The Clinical Study on the Constitutional symptomatic pattern of Soyangin and Taeumin inpatients in stroke (중풍입원환자(中風入院患者)의 소양인(少陽人)·태음인(太陰人) 체질병증유형(體質病證類型)에 관한 임상적(臨床的) 고찰(考察))

  • Lee, Jun-hee;Koh, Byung-hee;Song, Il-byung
    • Journal of Sasang Constitutional Medicine
    • /
    • v.12 no.1
    • /
    • pp.120-135
    • /
    • 2000
  • Objective ; The purpose of this study is to find out the constitutional symptomatic pattern of Soyangin and Taeumin through investigation of difference between two groups in stroke. Method ; 70 inpatients(Soyangin 31, Taeumin 39) in stroke, admitted into Kyung-Hee Oriental Hospital from 1. July. 1999 to 20. Sept. 1999, were investigated through questionnare which consists of 16 parts 155 questions, and the problems which have significant difference between Soyangin and Taeumin group were analyzed statistically. Result 1. The analysis of general characteristic difference between Soyangin and Taeumin group (1) The number of Soyangin patients is 31, Taeumin 39 and the number of Male patients 43, Female 27. (2) The mean weight of Taeumin group is heavier than that of Soyangin group and the degree of obesity of Taeumin group higher. (3) The number of patients who have smoking history is more at Soyangin group. (4) In neurological problem, dizziness is more complained of in Soyangin group. 2. The analysis about the result of Questionnare (1) In problems related with 'Sleeping', the time of going to bed and getting up and the duration of sleeping are more irregular in Taeumin group. (2) In problems related with 'Defecation', the shape of stool is more variable in Taeumin group. (3) In problems related with 'Urination', Soyangin group have more complaint. (4) In problems related with 'The condition of digestion', Taeumin group have a good appetite and more compalint in lower abdominal region, but on the contrary Soyangin group lose appetite and have more complaint in upper abdominal region. (5) In problems related with 'Head and Face', Soyangin group have more complaint. (6) In problems related with 'Eye, Ear and Nose', Soyangin group have more complaint at eye and ear. (7) In promlems related with 'Chest region', Soyangin group easily feel choked up and Taeumin group heart throbs. (8) In problems related with 'Skin', Taeumin group easily feel change of color tone at skin and Soyangin group dry.

  • PDF

Prevalence Rate of Lead Related Subjective Symptoms in Lead Workers (연취급 근로자의 연폭로 수준에 따른 주관적 자각증상 호소율)

  • Jeong, Du-Shin;Kim, Hwa-Sung;Ahn, Kyu-Dong;Lee, Byung-Kook
    • Journal of Preventive Medicine and Public Health
    • /
    • v.26 no.2 s.42
    • /
    • pp.251-267
    • /
    • 1993
  • The relationship between lead related subject symptoms and lead exposure indices was studied in 435 male lead workers in thirteen lead using industries. 212 male office workers who were not exposed to lead occupationally were also studied as a control group. Fourteen lead related symptoms were selected. They were further subdivied into 4 sub-symptom groups such as 1) gastrointestinal, 2) neuromuscular and joint 3) constitutional, and 4) psychological symptoms. Symptom questionnaires were provided to the workers and filled up by themselves and reconfirmed by interviewer(doctor). The test used fer the evaluation of lead exposure were blood lead(PbB), zinc protoporphyrin in whole blood(ZPP), hemoglobin(Hb), hematocrit (Hct), delta-aminolevulinic acid in urine(DALA). The results obtained were as follows; 1. The higher prevalence rate in the sub-group of neuromuscular and joint symptoms was observed in occupationally lead exposed subjects than non-exposed subjects. Among the sub-groups, the most frequent symptom was 'numbness of finger, hands or feet', and the prevalence of the symptom of 'arthralgia', 'weakness of fingers, hands or feet' and 'myalgia' were higher in order. 2. While the symptom which showed the biggest difference of prevalence rate among the 14 symptoms between exposed and non-exposed subjects was 'numbness of fingers, hands or feet', the symptom which showed the highest prevalence rate was 'feeling tired generally' in exposed and non-exposed subjects, but no statistical difference of symptom prevalence were observed. 3. In total study population, PbB and ZPP had dose-response relationship with 4 symtoms of neuromuscular and joint symptoms ('numbness of finger, hands or feet', 'arthralgia', 'weakness of fingers, hands or feet' and 'myalgia') and one symptom of gastrointestinal group('intermittent pains in lower abdomen'). 4. In lead exposed workers, only neuromuscular and joint symptoms group showed dose-response relationship with PbB and ZPP, 5. In lead exposed workers, the prevalance rate of overall symptoms of lead workers with age below 39 years was higher than that of lead workers with age above 40. While neuromuscular and joint symptoms group had a dose-response relationship with PbB in former group, it had a dose-response relationship with ZPP in latter group. 6. Age adjusted odds ratios of symptoms of non-exposed with exposed and odds ratios of low exposed with high exposed workers showed the dose-response relationship of lead exposure with neuromuscular and joint symptoms group('numbness of fingers, hands or feet', 'arthralgia', 'weakness of fingers, hands or feet' and 'myalgia') and gastrointestinal symptoms group('intermittent pains in lower abdoman').

  • PDF

Changes in Subjective Symptom, Tear Film Stabilization and Blinking Rates when Wearing RGP Lenses with Different Polishing Conditions for Certain Period of Time (연마상태가 다른 RGP렌즈의 일정기간 착용 시 렌즈착용자의 자각적 증상, 눈물막 안정 및 순목횟수 변화)

  • Park, Mijung;Kim, Hyo Gyum;Bae, Jun Seob;Park, Jung Ju;Kim, So Ra
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.19 no.1
    • /
    • pp.31-42
    • /
    • 2014
  • Purpose: The present study was conducted to investigate the effect of the physical properties of RGP lens induced by lens polishing on the actual wearer's subjective comfort, the tear film break-up time and the blinking rate as a follow-up study that revealed the relationship between the lens physical properties during lens manufacturing and lens wearer's factors. Methods: RGP lenses made from the three different polishing conditions (25, 50 and 100 seconds) were applied on 28 eyes of 17 subjects, aged 20 to 29 years, without any known disease and surgical history in the eyes. While the subjects were asked to wear the RGP lenses longer than a week, the questionnaire for the comfortability was administered everyday. Subjective and objective tear break-up time and blinking rate of the wearers were further measured. Results: The wearer's subjective comfortability showed some difference in the type of discomfort and satisfaction score according to the polishing status when wearing RGP lenses made from different polishing conditions longer than a week, and a bigger difference in satisfaction score induced by polishing condition was especially shown in experienced RGP lens wearer rather than un-experienced wearer. In the case of RGP lens wearer compared with the ones without the wearing experience, as the wearing time increased subjective and objective tear break-up time were increased and the blinking rate was decreased. However, subjective and objective tear break-up time were tended to decrease with even longer wearing time when wearing the RGP lens made from the polishment for 100 seconds. Conclusions: These results confirmed that the optimization of physical properties of the lens may not give the same effect on the wearer's subjective and objective symptoms and other factors when actual wearing. From the results, it can suggest that the success rate of RGP lens wear may be changed by physiological factors such as the stabilization of wearer's tear film, comfortability and lens wearing experience when wearing RGP lens based on 'The manufacturing standard for soft contact lens/hard contact lens' provided by Korea Food and Drug Administration.