• Title/Summary/Keyword: 시스템 성능계수

Search Result 1,032, Processing Time 0.028 seconds

A study for a Performance analysis of Hybrid heat pump Air conditioning system (복합열원형 히트펌프 냉난방 시스템의 성능분석에 관한 연구)

  • Lim, Hyun-Mook;Park, Hee-Moon;Cho, Soo;Sung, Uk-Joo;Park, Jin-Hoon;Park, Tae-Jin
    • Proceedings of the SAREK Conference
    • /
    • 2009.06a
    • /
    • pp.1373-1378
    • /
    • 2009
  • This study is aiming comparison and analization between efficiency of hybride air conditioning system which uses low temperature water under dam and air and EHP(Electric Heat Pump). The experimental was carried out with air cooling tests for EHP system having 80HP and composition heat pump system. P-i diagram of both systems and COP was used to derive schemetic and calcuations. As results of the tests, hybride system has 1.4 time higher efficiency coefficient.

  • PDF

Study on the Performance Characteristics of Hybrid Solar Heating System during Spring Season (봄철 태양열 하이브리드 시스템의 성능특성 연구)

  • Pyo, Jong-Hyun;Kim, Won-Seok;Cho, Hong-Hyun;Park, Cha-Sik
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.22 no.5
    • /
    • pp.296-303
    • /
    • 2010
  • An experimental study was carried out to investigate performance characteristics of the hybrid solar system during spring season. The system operating condition, each load, and heat pump performance were analyzed with the cloud cover. As a results, the collector heat, solar fraction, and hot water load were decreased with a rise of the cloud. The heating load was considerably effected by the ambient temperature regardless of the cloud cover. Besides, the temperature of hot water increased with the solar radiation. The COP of the heat pump was significantly influenced by the ambient temperature, that was 2.09~2.46 for gray day and 1.94~2.71 for fair day, respectively.

이젝터가 부착된 냉동시스템의 성능실험

  • 이원희;김윤조;김민수
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.13 no.10
    • /
    • pp.993-1001
    • /
    • 2001
  • Experimental investigation on the performance of dual-evaporator refrigeration system with an ejector has been carried out. In this study, a hydrofluorocarbon (HFC) refrigerant R134a is chosen as a working fluid. The condenser and two-evaporators are made as concentric double pipes with counter-flow type heat exchangers. Experiments were performed by changing the inlet and outlet temperatures of secondary fluids entering condenser, high-pressure evaporator and low-pressure evaporator at test conditions keeping a constant compressor speed. When the external conditions (inlet temperatures of secondary fluid entering condenser and one evaporator) are fixed, results show that coefficient of performance (COP) increases as the inlet temperature of the other evaporator rises. It is also shown that the COP decreases as the mass flaw rate ratio of suction fluid to motive fluid increases. The COP of dual-evaporator refrigeration system with an ejector is superior to that of a single-evaporator vapor compression system by 3 to 6%.

  • PDF

Influence of the Secondary Fluid Flow Rate on the Performance of a GSHP System (지중 순환수 유량 변화에 따른 지열원 히트펌프 시스템의 성능 특성 연구)

  • Lee, Jun-Yub;Chung, Jin-Taek;Woo, Jung-Son;Choi, Jong-Min
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.22 no.10
    • /
    • pp.649-656
    • /
    • 2010
  • The aim of this study is to investigate the influence of the secondary fluid flow rate through GLHX on a GSHP system with vertical single U-tube type GLHXs. The COP of a GSHP system with large flow rate was lower than it with small flow rate due to large power consumption of ground loop circulating pump. It is suggested that the heat pump unit with high COP and low flow rate through the GLHX have to be selected in order to enhance the performance of the system and reduce the length of GLHX.

Self-noise Cancellation in the Passive Sonar System (수동 소나 시스템에서 자체 잡음 제거)

  • 박상택
    • Proceedings of the Acoustical Society of Korea Conference
    • /
    • 1991.06a
    • /
    • pp.117-121
    • /
    • 1991
  • 본 논문은 견인선(tow-ship)에서 발생하는 자체 잡음을 제거하여 수중 신호처리 시스템에서 표적 탐지(target detection)와 표적 식별(target identification) 등의 성능 향상을 위하여 표적 방향으로 형성된 빔의 출력을 원시 입력신호(primary input)로 사용하고 견인선 방향으로 형성된 빔의 출력을 참고 입력신호(reference input)로 사용한 적응 잡음 제거기(adaptive noise canceller)에 대해 연구하였다. 잡음 제거를 위해 사용되는 계수들은 LMS(Least Mean Square) 알고리듬을 이용하여 조정하였다. 컴퓨터 시뮬레이션을 통하여 TDL(Tapped-Delay Line) 구조와 LAT(LATtice) 구조를 갖는 적응 잡음 제거기 성능을 여러 가지 환경에서 비교, 관찰하였다. 두 알고리듬을 사용할 경우, 자체 잡음이 어떠한 형태로 나타나더라도 제거시킬 수 있음을 보여 주었으나 고유값 분포율(eigenvalue spread ratio)이 큰 경우에는 LMS-LAT가 LMS-TDL보다 수렴 속도뿐만 아니라 성능면에서도 우수함을 보였다.

  • PDF

Performance Analysis of a Refrigeration System with Parallel Control of Evaporation Pressure (증발압력 병렬제어 냉동시스템의 성능해석)

  • Lee, Jong-Suk
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.32 no.8
    • /
    • pp.567-573
    • /
    • 2008
  • The conventional refrigeration system is composed of a compressor, condenser, receiver, expansion valve or capillary tube, and an evaporator. The refrigeration system used in this study has additional expansion valve and evaporator along with an evaporation pressure regulator(EPR) at the exit side of the evaporator. The two evaporators can be operated at different temperatures according to the opening of the EPR. The experimental results obtained using the refrigeration system with parallel control of evaporation pressure are presented and the performance analysis of the refrigeration system with two evaporators is conducted.

Power performance Testing of Small Wind Turbine Generator System (소형 풍력발전시스템의 출력성능검사)

  • Kim, Hyeon-Ki;Kim, Byeong-Min;Yoo, Neung-Soo
    • Journal of Industrial Technology
    • /
    • v.31 no.A
    • /
    • pp.123-128
    • /
    • 2011
  • In this study, procedures, a power performance testing system of Wind Turbine System Research Center of Kangwon National University is introduced. Test prodedures and results are presented on a stand-alone vertical-axis 200W wind turbine manufactured by Geum-Poong Energy Inc.. Power performance test is performed according to IEC standard. The test results are compared with the power performance standard. Also, the effects of normalization and disturbed sectors are considered.

  • PDF

Performance of Closed-loop Transmit Antenna Diversity System with Sub-optimal Beam-forming and Fading Corrrelation (준 최적 빔 형성과 페이딩 상관을 갖는 송신 안테나 다이버시티 시스템의 성능)

  • Kim, Nam-Soo
    • Journal of the Institute of Electronics Engineers of Korea TC
    • /
    • v.41 no.8
    • /
    • pp.1-7
    • /
    • 2004
  • The effect of the sub-optimal beam-forming and the fading channel correlation on the closed loop transmit antenna diversity(CTD) system is investigated in frequency flat Rayleigh fading channels. The fast channel fading prevents the perfect channel estimation at a mobile station, hence the imperfect weight is applied to the antenna branch of transmitter. The weight causes sub-optimalbeam-forming and aggravates the performance of CTD system. The fading correlation or a wireless channel also is one of the factors decreasing the diversity gain. A bit error rate expression for the CTD system is analytically derived as a function of the channel estimation error, the channel correlation coefficient the feedback delay, and fading index. It is shown that the channel estimation error gives more severe effect to the system performance than the channel correlation.

Seismic Performance Evaluation of Flat Column Dry Wall System and Wall Slab System Structures (무량복합 및 벽식 구조시스템의 내진성능평가)

  • Kang, Hyungoo;Lee, Minhee;Kim, Jinkoo
    • Journal of the Computational Structural Engineering Institute of Korea
    • /
    • v.25 no.3
    • /
    • pp.259-266
    • /
    • 2012
  • In this paper the seismic performance of a flat plate wall system structure was evaluated based on the ATC-63 approach, and the results were compared with those of a wall slab structure having the same size. As analysis model structures, a twelve story flat plate wall structure and a wall slab structure were designed based on the KBC-2009, and their seismic performances and collapse behaviors were evaluated by nonlinear static and incremental dynamic analyses(IDA). It was observed that the flat plate wall structure was designed with smaller amount of reinforced concrete, and showed slightly larger displacement response compared with those of the wall slab structure. The collapse margin ratios of the two structures obtained from the incremental dynamic analyses satisfied the limit states specified in the ATC-63, and the structures turned out to have enough capacity to resist the design level seismic load.

Controller design for SWATHS (쌍동선을 위한 제어기의 구성)

  • 박찬식;이장규;박성희
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 1986.10a
    • /
    • pp.503-505
    • /
    • 1986
  • 주어진 제어대상 모델에 대하여 제어기를 구성하여 실제로 적용하는 경우 모델의 불일치, 모델링에서 고려하지 않은 외란(disturbance), 측정잡음등에 의하여 성능이 설계시와 달라진다. 실제적용에서도 성능을 계속 유지하기 위하여 제어기는 안정성, 계수변화(parameter variation)에 대한 강인성(robustness), 외란상쇄(disturbance rejection) 및 측정잡음에 둔감함등의 특성을 가져야 한다. 귀환(feedback)을 사용하여 제어기를 구성하는 경우 위의 모든 조건을 만족 시킬 수 없으므로 제어목적에 따라 적당한 조건을 선정하여 중요한 특성을 주로 갖게 한다. 본 논문에서는 쌍동선(small waterplane area twin hull ship-SWATHS)에 대하여 PID, LQ, LQG 제어기를 구성하여 안정성, 계수 변화에 대한 강인성, 외란 상쇄 및 측정잡음의 영향을 비교하였다. 쌍동선의 경우 다른 단동선(mono hull ship)에 비하여 접수면(waterplane)이 적으므로 무게증변을 흡수할 수 있는 복원력이 약하여 적은 외력에도 상하동요(heave)와 종동요(pitch)가 심하게 일어난다. 이러한 동요를 줄이는 것이 쌍동선의 제어목적이다. 본 연구에서는 먼저 선형화된 수직축 운동방정식을 이용하여 선체운동의 모델을 구했으며 중첩의 원리(super-position theorem)에 의하여 주파수 응답의 합으로 파도입력을 모델링 하였으며 제어를 위하여 필요한 측정치는 IMU(Inertial Measurement Unit)에서 제공된다고 가정하였다. 쌍동선의 동요의 원인은 파도, 바람, 조류 등이 있으나 파도에 의한 영향이 가장 크므로 본 논문에서는 파도에 의한 영향만을 고려하였다. 파도는 쌍동선에 외란으로 작용하며 측정할 수 없는 양이므로 PID, LQ 제어에서는 제어모델에 포함되지 않지만 LQG 제어에서는 제어모델에 포함된다. LQG 제어의 경우 제어모델에 파도를 백색잡음으로 가정하고 제어기를 구성한 것 (LQG1)과 2차의 쉐이핑필터(shaping filter)를 사용하여 구성한 것(LQG2)으로 나누었다.

  • PDF