• Title/Summary/Keyword: 시스템 멀티 에어컨

Search Result 19, Processing Time 0.022 seconds

Evaluation of the operating reliability on the concurrent heating-cooling system air conditioner with high-head and long-line conditions (동시냉난방 시스템 에어컨의 고낙차 장배관 운전 신뢰성 평가)

  • Kim, Tae-An;Lee, Seung-Chan;Tae, Sang-Jin;Jung, Gyoo-Ha;Moon, Je-Myung;Kim, Youn-Jea
    • Proceedings of the SAREK Conference
    • /
    • 2008.06a
    • /
    • pp.609-614
    • /
    • 2008
  • The heating and cooling performance of system multi-air conditioner under high-head and long-line conditions are experimentally investigated. The maximum head and tube length were 110 m and 1000 m, respectively. The experimental system was composed of 4 outdoor units with module systems, and 13 indoor units which were joined with the mode change unit by single-tube circuit. Field tests without indoor and outdoor temperature control were performed in a general office building with 22 different working conditions. Experimental results were prepared on the p-h diagram. Also the oil level in the compressor was normally maintained at the safety zone for the system multi-air conditioner with high-head and long-line conditions.

  • PDF

Evaluation of the operating reliability on the concurrent heating-cooling system air conditioner for different refrigerant flow rates with high-head and long-line conditions (동시냉난방 시스템 에어컨의 냉매량 변화에 따른 고낙차 장배관 운전 신뢰성 평가)

  • Lee, Seung-Chan;Kim, Tae-An;Tae, Sang-Jin;Jung, Gyoo-Ha;Moon, Je-Myung;Kim, Youn-Jea
    • Proceedings of the SAREK Conference
    • /
    • 2008.11a
    • /
    • pp.304-309
    • /
    • 2008
  • The heating and cooling performances of system multi-air conditioner for various refrigerant flow rates with high-head and long-line conditions are experimentally investigated. The maximum head and tube length were 110 m and 1000 m, and the two different adjustments of refrigerant flow rates were +20 % and -20 %, respectively. The experimental system was composed of 4 outdoor units with module systems, and 13 indoor units which were joined with the mode change unit by single-tube circuit. Field tests without indoor and outdoor temperature control were performed in a general office building with two different refrigerant flow rates. Especially, the oil level in the compressor was normally maintained at the safety zone. Experimental results were prepared on the p-h diagram.

  • PDF

Effects of Accumulator Heat Exchangers on the Performance of a Refrigeration System (열교환기 내장형 어큐물레이터가 냉동시스템의 성능에 마치는 영향에 관한 연구)

  • Kang, Hoon;Choi, Kwang-Min;Park, Cha-Sik;Kim, Yong-Chan
    • Proceedings of the SAREK Conference
    • /
    • 2005.11a
    • /
    • pp.433-438
    • /
    • 2005
  • An AHX(Accumulator Heat eXchanger) consists of a commercial accumulator and an inner heat exchanger located inside of the accumulator. The AHX is used in multi air-conditioners to assure the liquid-phase refrigerant entering into the expansion device. This purpose is achieved by heat transfer between the refrigerant leaving the evaporator and the refrigerant leaving the condenser. In this study, the effects of AHX on the performance of a refrigeration system using H-22 were measured and the test results were analyzed. The operating characteristics of the refrigeration system with the installation of AHX were quite different from those without the installation of AHX. Therefore, it is required to find an optimum refrigerant charging amount and optimum operating conditions, when AHX is installed in the refrigeration system with an fixed area expansion device such as a capillary tube.

  • PDF

Performance Characteristics of Accumulator Heat Exchangers with Operating Conditions of a Refrigeration System (냉동시스템의 운전조건에 따른 열교환기 내장형 어큐뮬레이터의 성능 특성)

  • Kang, Hoon;Park, Cha-Sik;Jeon, Jong-Ug;Kim, Yong-Chan
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.18 no.12
    • /
    • pp.984-991
    • /
    • 2006
  • The applications of multi air-conditioners into multiplex and high-rise buildings have been increased by replacing central air-conditioning systems. The pipe length and altitude difference between the indoor and outdoor units can be increased based on installation conditions, which may increase the possibility of flash gas generation at the expansion device inlet. The flash gas generation causes rapid reduction of refrigerant flow rate passing through the expansion device, yielding lower system efficiency. Accumulator heat exchangers have been widely used in multi air-conditioners in order to minimize flash gas generation and obtain system reliability. However, the studies on the heat transfer characteristics and pressure drops of accumulator heat exchangers are very limited in open literature. In this study, the heat transfer rates and pressure drops of accumulator heat exchangers were measured with refrigerant flow rate and operating conditions by using R-22. The heat transfer rate increased with the increase of refrigerant flow rate, while subcooling decreased. The heat transfer rate enhanced with the reduction of inlet superheat and subcooling due to the increased temperature difference between the accumulator and inner heat exchanger.

Effects of Accumulator Heat Exchanger on the Performance of a Refrigeration System (열교환기 내장형 어큐뮬레이터가 냉동시스템의 성능에 미치는 영향에 관한 연구)

  • Kang Hoon;Choi Kwang-Min;Park Cha-Sik;Kim Yong-Chan
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.18 no.5
    • /
    • pp.418-425
    • /
    • 2006
  • An AHX (Accumulator Heat exchanger) consists of a commercial accumulator and an inner heat exchanger located inside of the accumulator. The AHX is used in multi air-conditioners to assure that liquid-phase refrigerant enters into the expansion device. This purpose is achieved by heat transfer between the refrigerant leaving the evaporator and the refrigerant leaving the condenser. In this study, the effects of AHX on the performance of a refrigeration system using R-22 were measured and the test results were analyzed. The operating characteristics of the refrigeration system with the AHX are considerably different from those without the AHX. Therefore, it is required to determine optimum refrigerant charge and optimum operating conditions when the AHX is used in the refrigeration system having a constant flow-area expansion device such as capillary tube.

A Indoor Management System using Raspberry Pi (라즈베리 파이를 이용한 실내관리 시스템)

  • Jeong, Soo;Lee, Jong Jin;Jung, Won Ki
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.17 no.9
    • /
    • pp.745-752
    • /
    • 2016
  • In the era of the Internet of Things, where all physical objects are connected to the Internet, we suggest a remote control system using a Raspberry Pi single-board computer with ZigBee, which can turn an indoor light-emitting diode (LED) and a multiple-tap on and off, and with a smart phone can control the brightness of the LED as well as an electronic door lock. By connecting an infrared (IR) transmitter module to the Raspberry Pi, we can control home appliances, such as an air conditioner, and we can also monitor indoor images, indoor temperatures, and illumination by using a smart phone app. We developed a method of finding out IR transmission codes required for remote-controllable appliances with an AVR micro-controller. We suggest a method to remotely open and shut an office door by novating the door lock. The brightness level of an LED (between 0 and 10) can be controlled through a PWM signal generated by an ATmega88 microcontroller. A mutiple-tap is controlled using an ATmega32, a photo-coupler, and a TRIAC. The signals for measured temperature and illumination are converted from analog to digital by using the ATtiny44A microcontroller transmitting to a Raspberry Pi through SPI communication. Then, we connect a camera to the CSI head of the Raspberry Pi. We can turn on the smart multiple-tap for a certain period of time, or we can schedule the multi-tap to turn on at a specific time. To reduce standby power, people usually pull out a power code from multiple-taps or turn off a switch. Our method helps people do the same thing with a smart phone, if they are away from home.

Economic Analysis and Comparison between Hybrid and Central Air Conditioning System (혼합공조와 중앙공조 시스템의 경제성 분석 및 비교)

  • Lee, Yoon-Jong;Kim, Chan-Jung;Moon, Je-Myung;Kim, Cheol-Woo;Seo, Hyeong-Joon;Kim, Gyoung-Rok;Shin, Haeng-Cho;Hong, Hi-Ki
    • Proceedings of the SAREK Conference
    • /
    • 2007.11a
    • /
    • pp.334-339
    • /
    • 2007
  • This paper is concerned with economic analysis and comparison between hybrid and central air conditioning system by TRNSYS simulation and Life Cycle Cost(LCC) analysis. Hybrid air conditioning system that is using VAV for interior zone and system air-conditioner for perimeter zone is installed in building A. Central air conditioning system is composed of VAV and convector. The simulation was carried out in mode temperature level control using TRNSYS 16. From the result of simulation and LCC analysis, hybrid air conditioning system was better than central air conditioning system in initial cost and energy consumption.

  • PDF

Study on the Compared between u-Learning and e-Learning based SCORM (SCORM 기반 u-Learning과 e-Learning 비교연구)

  • Choi, Sung;Ryu, Gab-Sang
    • Proceedings of the Korea Society of Information Technology Applications Conference
    • /
    • 2006.06a
    • /
    • pp.495-505
    • /
    • 2006
  • IT기술기반 교육시스템은 인터넷 등장 이전에도 가능성을 인정받아 지속적으로 개발되어 온 분야이며, 교육공학과의 연계로 지식 전날의 이론체계로 각광을 받고 있다. 사이버교유도 인터넷이전부터 다양한 통신방법을 응용하여 개발되었고, 최근 인터넷을 통하여 사이버 교육시스템은 완벽한 기술기반을 갖추게 되였다. 그러나 IT기술의 급격한 변화로 사이버교육시스템은 계속하여 신기술 변화에 적용해야만 한다. 현재 정보통신기술의 변화는 방송 통신망의 융합, 브로드 밴드 네트워킹, 스마트 디바이스의 다양화, 멀티미디어 기술의 고도화로 요약된다. 이 기술의 종합한 작용으로 유비쿼터스 사회의 기반으로 진화되고 있다. 그래서 e-Learning 분야도 기존 인터넷기반 시스템과는 달리 차세대 온라인교육시스템으로 친화되고 있다. IT융합가술 기반의 온라인 교육시스템은 각종 국제표준단체에서 표준안이 제시되고 있다. e-Learning 시스템이란 선기술 기반을 반영한 표준기술을 사용하는 온라인교육시스템을 포괄하는 개념이다. 본 연구에서는 e-Learning 시스템과 유비쿼터스 기술을 반영한 e-Learning을 비교하였다. 그리고 u-Learning 시스템의 기술정립과 EOD(Education On Demand) 시스템에 대하여 연구하였다. 1. u-Learning 정의 정보산업분야를 비롯한 문화, 교육 등 모든 분야에서 유비퀴터스라는 수식어가 붙어 다니고 있다. e- Learning 교육 업계에 따르면 10년 후에는 유비쿼터스는 대중화가 될 것이며, 부가가치 규모는 100조 원에 이를 것으로 추정된다. 그래서 교육산업도 주변 환경이 아날로그 방식에서 IT 기반에 의한 디지털 환경으로 변화되고 있다. 또한 e러닝, T러닝, m러닝, u러닝 등의 용어가 생성되고 있다.키지에어컨에서 사용되고 있는 밀폐형 압축기에 대해서 그림 2에서 나타내고 있는 냉방능력 10tons(120,000Btu/h) 이하를 중심으로 상기의 최근 기술 동향을 간략하게 소개하고자 한다.질표준의 지표성분으로 간주되는 진세노사이드의 절대함량과 그 성분조성 차이에 따른 임상효과의 차별성이 있는지에 대한 검토와, 특히 최근 실험적으로 밝혀지고 있는 사포닌 성분의 장내 세균에 의한 생물전환체의 인체 실험을 통한 효과 검정이 필요하다. 나아가서는 적정 복용량의 설정과 이와 관련되는 생체내 동태 및 생체이용율(bioavilability)에 관한 정보가 거의 없으므로 이것도 금후 검토해야 할 과제로 사료된다. 인삼은 전통약물로서 오랜 역사성과 그동안의 연구결과에 의한 과학성을 가지고 있으므로 건강유지와 병의 예방 및 회복촉진을 위한 보조요법제 또는 기능성 식품으로써의 유용성이 있는 것으로 판단된다. 앞으로 인삼의 활용성 증대를 위해서는 보다 과학적인 임상평가에 의한 안전성 및 유효성 입증과 제품의 엄격한 품질관리의 필요성이 더욱 강조되어야 할 것이다.xyl radical 생성 억제 효과를 보여 주었다. 본 실험을 통하여 BHT 를 제외하고 전반적으로 세포 수준에서의 oxidative stress 에 대한 억제 효과를 확인해 볼 수 있었으며 특히 수용성 항산화제들에서 두드러진 효과를 보여 주었다. 제공하여 내수기반 확충에도 노력해야 할 것 이다.있었다., 인삼이 성장될 때 부분적인 영양상태의 불충분이나 기후 등에 따른 영향을 받을 수 있기 때문에 앞으로 이에 대한 많은 연구가 이루어져야할 것으로 판단된다.태에도 불구하고 [-wh]의미의 겹의문사는 병렬적 관계의 합성어가 아니라 내부구조를 지니지 않은 단순한 단어(minimal $X^{0}$<

  • PDF