• Title/Summary/Keyword: 시력교정

Search Result 178, Processing Time 0.022 seconds

The Sterilization Effectiveness for Bacterial Contamination by Cleaning Methods in the Glasses for Vision Correction (시력교정용 안경의 세척 법에 따른 오염 균의 제균 효과)

  • Back, Seung-Sun;Kim, Hyun-Kyung;Lee, Kyu-Byung;Lee, Hyun-Joo;Kim, Heung-Soo
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.18 no.2
    • /
    • pp.101-106
    • /
    • 2013
  • Purpose: This research was to evaluate the sterilization effectiveness for bacterial contamination by general cleaning method of glasses for vision correction. Methods: From 82 eyeglass wearers the number of bacteria before and after cleaning was counted to check the status of the eradication. Results: The results after ultrasonic cleaning by using the tap water did not showed change of bacterial species. Ultrasonic cleaning using the 70% rubbing alcohol showed cleaning of 46.2% of bacteria. Ultrasonic cleaning using the 70% rubbing alcohol after brushing with general detergent showed clearing of 85.7% of bacteria. Conclusions: When glasses were brushed with a detergent, opportunities infectious bacteria in glasses for vision correction were removed effectively. These results can be suggested as a guideline for management of clean glasses.

The Effects of the Relative Legibility of Optotypes on Corrected Visual Acuity (시표의 유형에 따른 상대가독성이 교정시력에 미치는 영향)

  • Ha, Na-Ri;Choi, Jang-Ho;Kim, Hyun Jung
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.20 no.2
    • /
    • pp.177-186
    • /
    • 2015
  • Purpose: The Purpose of this study is to investigate if the relative legibility of optotypes affects the corrected visual acuity in visual acuity test. Methods: After measuring the relative legibility of 'Landolt ring target', 'arabic number target', 'alphabet target' by showing as a single-letter-target in 24 subjects without specific ocular diseases and ocular surgery experience, the relative legibility of 0.8, 1.0, 1.25 row of vision according to type of target in 7 types of chart were compared. After then we compared by measuring the corrected visual acuity according to type of target by using binocular MPMVA test (#7A) in 60 myopic subjects. Results: In 3 types of target the worst relative legibility target was 'Landolt ring target' with legible distance of $98.97{\pm}4.57cm$ and the best relative legibility target was 'alphabet target' with legible distance of $108.42{\pm}3.46cm$. There was no difference of the relative legibility according to type of chart or visual acuity level in the row of vision if other conditions are the same. In 1.0 and 1.25 row of vision the difference of relative legibility according to type of target was shown the statistically significant difference between 'Landolt ring target' and 'alphabet target' as $-0.07{\pm}0.06$ (p=0.02) and $-0.06{\pm}0.06$ (p=0.04) respectively. In myopia the difference of corrected visual acuity according to type of target was statistically significant difference between 'Landolt ring target' and 'arabic number target' as $-0.04{\pm}0.02$ (p=0.02) and it was especially remarkable in the low myopia. Conclusions: Measuring visual acuity with different optotypes could cause the errors in best vision measurement value because there was difference of the relative legibility according to type of target even though visual acuity level is same in the row of vision.

Assessment of Visual satisfaction & Visual Function with Prescription Swimming goggles In-air and Underwater (도수 수경 착용시 실내와 수중에서의 시각적 만족도 및 시력 평가)

  • Chu, Byoung-Sun
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.18 no.4
    • /
    • pp.357-363
    • /
    • 2013
  • Purpose: To investigate the visual function with prescription swimming goggles. Methods: 15 university students (mean age: $22{\pm}1.54$ years) participated, with a mean distance refractive error of RE: S-1.67 D/C-0.40 D, LE: S-1.70D/C-0.37 D. Inclusion criteria were no ocular pathology, able to wear soft contact lenses to correct their refractive error to emmetropia and able to swim. Participants were fitted with contact lenses to correct all ametropia. Subjective evaluation for satisfaction of visual acuity, asthenopia and balance were also measured using a questionnaire while wearing swimming goggles with cylinder (C+1.50 D, Ax $90^{\circ}$) compared with plano sphere outside the swimming pool area. Visual acuity was assessed using the same ETDRS chart. The prescription swimming goggles powers were assessed in random order and ranged in power from S+3.00 D to S-3.00 D in 0.50 D steps. Results: Subjective evaluation was significantly worse for the swimming goggles with cylinder than for the plano powered goggles for all 3 questions, visual acuity, asthenopia and balance. Visual acuity were significantly affected by the different power of the swimming goggles (p<0.05), but there was no significant difference between the in-air in-clinic and underwater in-swimming pool measures (p=0.173). However, visual acuity measured in the clinic was significantly better than underwater for some swimming goggle powers (+3.00, +1.00, +0.50, 0, -1.00 and -2.00 D). Conclusions: Wearing swimming goggles underwater may degrade the visual acuity compared to within air but as the difference is less than 1 line of Snellen acuity, and it is unlikely to result in significant real-life effects. Having an incorrect cylinder correction was found to be detrimental resulting in lower score of satisfaction. Considering slippery floor of swimming pool area, it can be a potential risk factor. Therefore, it is important to correct any refractive error in addition to astigmatism for swimming goggle.

Clinical results of wavefront guided laser in situ keratomileusis (파면 유도 맞춤 굴절교정각막수술의 임상 결과)

  • 이경섭;최철명;유용성;김진국;고동섭;권혁제;김현수
    • Proceedings of the Optical Society of Korea Conference
    • /
    • 2003.02a
    • /
    • pp.126-127
    • /
    • 2003
  • 눈의 시력을 진단하는 도구로는 시력표, 검영기, 빔프로젝터, 자동굴절력측정기 등이 있다. 파면분석기(wavefront aberrometer)를 이용하면 눈의 굴절력 및 난시도수 외에도 광학적 고위수차(higher order aberration)를 표현하는 파면수차함수를 산출할 수 있기 때문에, 눈의 결상 능력을 정확하고 정밀하게 진단할 수 있는 가능성을 가지고 있다. 따라서 파면분석기는 현재까지 사용되고 있던 시력 또는 굴절력 계측기들의 다음 세대를 이어갈 것으로 전망하고 있다. (중략)

  • PDF

The Effect of Long-Term Orthokeratology in Different Age Groups (장기간 굴절교정렌즈 착용자에서 연령군 별 굴절교정효과 비교)

  • Mun, Mi-Young;Lee, Koon-Ja
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.13 no.4
    • /
    • pp.65-73
    • /
    • 2008
  • Purpose: The purpose of this study is to investigate the effect of age in the response to long-term overnight orthokeratology (OK) lens wearing. Methods: Among volunteers, ninety-five healthy subjects who had no eye diseases and could wear OK contact lens at least for 8 hours every day were divided into three groups children, youngsters and young adults. Unaided logMAR visual acuity, refractive error, apical corneal radius, corneal asphericity and central corneal thickness were measured with different period; before and after one day, one week, two weeks, one month, three months and six months of OK lens wear. Paired student t-test, ANOVA analysis and Pearson correlation were used with a critical p value of 0.05 for statistical analysis. Results: All groups showed statistically significant (p<0.001) improvement in unaided visual acuity, a trend for flattening in the apical corneal radius, decrease in central corneal thickness and less prolate after OK lens wear. The child group showed significantly rapid change (p<0.001) in visual acuity, and apical corneal radius showed that they reached the targeted refractive change earlier compared with youngster and adult groups. The visual effect of OK lens was significantly related with the change in central corneal thickness after long-term OK lens wear, especially in child and youngster group, and central corneal thickness were highly correlated with the targeted refractive change. Conclusions: Visual acuity change is statistically correlated with the central corneal thickness change, which is highly correlated with targeted refractive change in the long-term orthokeratology and younger lens wearers showed a rapid response to OK lens wear, suggesting a reduced epithelial response with increasing age. The results found this study extends our understanding and development in the long-term orthokeratology.

  • PDF

Corneal Asphericity and Optical Performance after Myopic Laser Refractive Surgery (굴절교정수술을 받은 근시안의 각막 비구면도와 광학적 특성 평가)

  • Kim, Jeong-Mee;Lee, A-Young;Lee, Koon-Ja
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.18 no.2
    • /
    • pp.179-186
    • /
    • 2013
  • Purpose: To compare corneal asphericity, visual acuity (VA), and ocular and corneal higher-order aberrations (HOAs) between myopic refractive surgery and emmetropia groups. Methods: Twenty three subjects ($23.0{\pm}2.5$ years) who underwent myopic refractive surgery and twenty emmetropia ($21.0{\pm}206$ years) were enrolled. The subjects'criteria were best unaided monocular VA of 20/20 or better in both two groups. High and low contrast log MAR visual acuities were measured under photopic and mesopic conditions. Corneal and ocular HOAs were measured using Wavefront Analyzer (KR-1W, Topcon) for 4 mm and 6 mm pupils. Corneal asphericity was taken by topography in KR-1W. Results: There was no significant difference in VA between two groups under either photopic or mesopic conditions. In ocular aberrations, there were significant differences in total HOAs, fourthorder and spherical aberration (SA) for a 6 mm between two groups (p=0.045, p<0.001, and p<0.001, respectively). In corneal aberrations, there was a significant difference in SA for 4 mm (p=0.001) and 6 mm (p<0.001) pupils between two groups and there were statistically significant differences in total HOAs (p<0.001) and fourth-order aberrations (p<0.001) between two groups for a 6 mm pupil. There was a significant correlation in emmetropia between Q-value and SA in ocular aberrations for 4 mm and 6 mm pupils (r=0.442, p=0.004, and r=0.519, p<0.001) and in corneal aberrations for 4 mm and 6 mm pupils (r=0.358, p=0.023, and r=0.646, p<0.001). No significant correlations were found between Q-value and SA in refractive surgery group. Conclusions: VA in myopic refractive surgery is better than or similar to emmetropia. Nevertheless, the more increasing pupil size is, the more increasing aberrations are. Thus, it could have an influence on the quality of vision at night.

Effects of Induced Dioptric Blur on Visual Acuity and Contrast Sensitivity (유발된 광학적 흐림이 시력과 대비감도에 미치는 영향)

  • Kim, Chang-Jin;Choi, Eun Jung
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.19 no.2
    • /
    • pp.261-270
    • /
    • 2014
  • Purpose: To study the effect of an artificially induced dioptric blur on acuity and contrast sensitivity using the $Optec^{(R)}$ 6500. Methods: Healthy 31 subjects aged $22.90{\pm}1.92$ (male 16, female 15) who were recruited from university students with 6/6 (20/20) or better corrected visual acuity and normal binocularity. They were measured objective and subjective refraction for full correction and dioptric blur using 0.00 ~ +3.00 D (+0.50 D steps) trial lenses and trial frame. They were measured binocularly visual acuity and contrast sensitivity with the $Optec^{(R)}$ 6500 (Stereo Optical Co., Inc., Chicago, Illinois, USA) under day conditions (photopic condition, $85cd/m^2$). Results: The higher dioptric blur, the less distance visual acuity and decrease rate of visual acuity. The higher dioptric blur, the less contrast sensitivity at all frequencies, and the peak of contrast sensitivity was shifted from middle frequency (6 cpd) to low frequency (1.5 cpd). When the visual acuity was best visual acuity to 0.77, there was the peak point at 6 cpd which was normal contrast sensitivity peak point. Conclusions: If the low refractive error is uncorrected or the refractive error is inappropriate, the contrast sensitivity is decreased and the peak point of contrast sensitivity frequency is shifted abnormally though small uncorrected refractive error. So it will be considered that regular eye test and decision of refractive error correction is important.

Availability of Astigmatism Expectation by Jin's and Beam Project Chart (진용한 시력표와 투영식 시력표에서 난시량 예측의 용이성)

  • Kim, Sang-Moon;Kang, Hye-Sook;Shim, Hyun-Seog
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.17 no.1
    • /
    • pp.53-58
    • /
    • 2012
  • Purpose: The purpose of this study was to predict the amount of astigmatism through logMAR visual acuity by Jin's chart at best vision spherical power and to compare availability of astigmatism expectation by Jin's and beam project chart. Methods: LogMAR and decimal visual acuity were measured for 150 college students and visual acuity and compared the amount of astigmatism under full correction. Results: Jin's chart was showed marked differences at least more than 0.25 D intervals per line than beam project chart. Correlation with the amount of astigmatism was higher the logMAR visual acuity r = 0.8578 than decimal visual acuity r = -0.7199. Conclusions: LogMAR visual acuity at best vision spherical power was able to predict to amount of astigmatism and Jin's chart was easier than beam project chart to predict difference of each lines.

Visual acuity of age related changes during 5 years (연령별 시력 변화에 관한 연구)

  • Kim, Chang Sik;Lee, Hak Jun
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.5 no.2
    • /
    • pp.55-58
    • /
    • 2000
  • Spectacle diopter of age related changes during 5 years examined 360 eyes(male 79, women 81) who visited optical shop every year. Increasing refractive error of Myopia obviously appeared in young generation which term was elementary school, and then middle and high school. In this study, we concluded that term of correction spectacles should be 4 months in elementary school, 6 months in middle school, and every year in high school.

  • PDF

Changes in KVA Resulting from Correction Condition of Refractive Error (굴절이상 교정상태에 따른 동적시력 변화)

  • Shim, Hyun-Suk;Kim, Sang-Hyun;Kang, Hye-Sook
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.18 no.2
    • /
    • pp.165-171
    • /
    • 2013
  • Purpose: This study are to analyze and to compare between pupillary size, reaction time, refractive error, corrected vision, dominant eye, static visual angle (SVA) and kinetic visual acuity (KVA) of male and female college students, to measure KVA of them in full correction and to identify changes of KVA by +0.50 D and -0.50 D spherical power addition respectively in full correction condition. Methods: KVA, SVA, pupillary size, reaction time, refractive error, corrected vision and dominant eye of 40 male and 40 female optical science students were measured by utilizing KOWA AS-4A, reaction time measurement program, subjective refractometer, and objective refractometer, and KVAs were measured when +0.50 D/-0.50 D were added in both eyes respectively. Results: Binocular KVA of whole subjects was $0.45{\pm}0.22$, and in monocular KVAs were $0.36{\pm}0.19$ for right eye and $0.34{\pm}0.19$ for left eye, and binocular KVA was significantly higher than monocular KVA. It appeared that the better SVA was, the better KVA was in significant way, and in terms of refractive error the less myopia amount was, the better KVA was, but it was not significant statistically. The lower astigmatism was, the slightly and significantly higher KVA was when dividing between equal or less than -1.00 D astigmatism group and over -1.00 D astigmatism group. In resulting from correction condition of refractive error KVAs were $0.45{\pm}0.22$ for full correction, $0.26{\pm}0.15$ for +0.50 D addition, $0.48{\pm}0.22$ for -0.50 D addition which indicates that KVA in over myopia correction was significantly the highest and followed by full correction and under correction. Similar findings were revealed in both male and female, and KVA of male was better than female in comparing between male and female. There was no significantly different KVA between dominant eye and non-dominant eye. Conclusions: Accordingly, it is concluded that KVA is related with far distance SVA, astigmatism amount, and refractive error amount except a dominant eye. Through this research, it was found that prescription for enhancing KVA is to make full correction or to overcorrect slightly myopia.