• Title/Summary/Keyword: 시공간에 대한 해석

Search Result 961, Processing Time 0.026 seconds

Tunneling-induced Building Damage Risk Assessment System (터널굴착에 따른 인접건물 손상위험도 평가시스템)

  • Park, Yong-Won;Yoon, Hyo-Seok
    • Journal of the Korean Geotechnical Society
    • /
    • v.18 no.3
    • /
    • pp.51-59
    • /
    • 2002
  • This paper deals with development of a damage risk assessment system for adjacent buildings to under-passing tunnel face considering 3D-ground movement. The system consists of building and ground information module, monitoring data module, settlement evaluation module, and building damage risk assessment module. The major modules, settlement evaluation module and building damage assessment module, are based on settlement estimation model suggested by Attewell et al (1982) and the building damage assessment method by Mair et al. (1996). After estimating 3D-ground movements due to tunneling with settlement evaluation module, damage assessment far buildings is performed using building damage risk assessment module. The developed system has two major functions; 1) calculation of 3D-settlement with ground loss ($V_{s}$)or maximum settlement ($w_{max}$) and inflection point (i) using various empirical formulae, monitoring data, numerical results, and so on; 2) assessment of damage risk for adjacent buildings of arbitrary section with position change of tunnel face. The field data given by Boscadin and Cording (1989) leer the case of two-storied masonry building near the Metro tunnel in Washington D.C. was simulated to verify the applicability of the developed system.

A Comparison Study between Top-down Load Test and Bi-directional Load Test Analysis Method in Rock-socketed Small Size Drilled Shaft (암반소켓된 소구경 현장타설말뚝의 정재하시험과 양방향재하시험 분석법 비교연구)

  • Song, Myungjun;Song, Younghun;Jung, Minhyung;Park, Youngho;Park, Jaehyun;Lee, Juhyung;Chung, Moonkyung
    • Journal of the Korean GEO-environmental Society
    • /
    • v.14 no.9
    • /
    • pp.5-12
    • /
    • 2013
  • In this study, each top-down load test and bi-directional load test has been performed on the 480mm diameter of two rock socketed drilled shafts, which are located next to each other, and the results have been compared. The result shows that the settlement from the equivalent load-settlement curve of bi-directional load test is smaller than one from top-down load test, because elastic is not considered in equivalent load-settlement curve of bi-directional load test. Therefore elastic shortening should be considered to obtain appropriate equivalent load-settlement curve. Three existing methods used to obtain equivalent load-settlement curve with consideration of elastic shortening has been compared with the result of top-down load test. The result shows that those existing methods are sufficiently applicable to the design. In addition, result of comparison between top-down load test and bi-directional load test shows that bi-directional load test was found to overestimate bearing capacity because it does not consider pile body failure.

Evaluation on the Compression Capacity of Transfer Slab Systems according to the Variation of Column Length (기둥의 길이변화에 따른 전이슬래브 시스템의 압축성능 평가)

  • Sim, Yeon-Ju;Choi, Chang-Sik
    • Journal of the Korea Concrete Institute
    • /
    • v.28 no.6
    • /
    • pp.695-702
    • /
    • 2016
  • This paper presents compression capacity of transfer system in pilotis subjected to axial load. Recently, transfer system is usually used in low floors of wall-typed apartments when members' sections are suddenly changed between upper walls and bottom columns. It can help transfer loads from the walls to the columns. Especially, a transfer girder system is usually used as one of transfer systems applied to a pilotis. However, the transfer girder system has low constructability and economics. Therefore, the other transfer system with transfer slab was suggested and has been studied. In this paper, to evaluate the compression capacity of transfer slab, tests were conducted on pilotis transfer slab systems subjected to axial load. First of all, two specimens were determined by FEM. The main parameter is length of the bottom columns. The lengh of the bottom columns were 40% and 50% of length of upper walls in the tranfer slab specimens. Results showed that the compression capacity of piloti transfer systems subjected to axial load was affected by length of bottom columns. The compression capacity is 52% higher than design strength for specimen with the bottom column's length of 40% of length of the upper wall and 46% for specimen with the bottom column's length of 50% of length of the upper wall.

Longitudinal Arching Characteristics Around the Face of a Soil-Tunnel with Crown and Face-Reinforcement (굴진면 천단 및 수평보강에 따른 굴진면 전후의 종방향 아칭 특성)

  • Kwon Oh-Yeob;Choi Yong-Ki;Lee Sang-Duk;Kim Young-Gun
    • Journal of the Korean Geotechnical Society
    • /
    • v.20 no.9
    • /
    • pp.133-144
    • /
    • 2004
  • Pre-reinforcement ahead of a tunnel face using long steel or FRP (Fiberglass Reinforced Plastic) pipes in NATM(New Austrian Tunnelling Method), known as the RPUM(Reinforced Protective Umbrella Method) or UAM (Umbrella Arch Method), is the promising method to sustain the stability of a shallow tunnel face and reduce the ground settlements. In addition, horizontal reinforcing of the face is recently emphasized to improve the stability of the face. However, the characteristics on longitudinal arching around the face have not yet been established quantitatively with the RPUM (crown-reinforcing) and/or the face horizontal reinforcing. In this study, therefore, the behavior of cohesionless soil around the face reinforced by the reinforcing member representing the RPUM and horizontal reinforcing is investigated through two-dimensional laboratory model tests. A series of tests were carried out on various conditions by changing lengths and angles of the reinforcing members. Based on the vertical pressure around the face, the characteristics of longitudinal arching have been found for the case of the non-reinforced and the reinforced.

Partial Drainage Characteristics of Clayey Silt with Low Plasticity from the West Coast (서해안 저소성 점토질 실트 지반의 부분배수 특성)

  • Kim, Seok-Jo;Lee, Sang-Duk;Kim, Ju-Hyun
    • Journal of the Korean Geotechnical Society
    • /
    • v.32 no.9
    • /
    • pp.17-27
    • /
    • 2016
  • Parial drainage characteristics of clayey silt with low plasticity from the west coast (Incheon and Hwaseong) was analyzed using CPTU based existing correlation equations and compulsory replacement method. Generally, the estimated $OCRs={\kappa}{\cdot}((q_t-{\sigma}_{vo})/{\sigma}^{\prime}_{vo})$ using Powell and Quartman(1988) were higher than those obtained by the oeodometer tests. These trends were noticeable for the layers containing a lot of silty and sand soils. The assessment of partial drainage conditions was performed through Schnaid et al. (2004)'s equation; it is based on plotting the normalized cone resistance, $Q_t$ versus the pore pressure parameter, $B_q$ in combination with the strength incremental ratio, $s_u/{\sigma}^{\prime}_{vo}$ to the CPTU data. It is evident that more than half of the data fall in the range where $B_q$ < 0.3, corresponding to the domain in which the partial drainage prevails when testing normally consolidated soils at a standard rate of penetration (2 cm/s). To estimate the replacement depth of clayey silt with low plasticity, back analysis was carried out to evaluate the internal friction angle based on where the design depths are equal to the checked depths using bearing capacity equation. The internal friction angels obtained from the back analysis tended to increase as the plasticity index decreases, which is ranged approximately from ${\varphi}^{\prime}=2^{\circ}$ to ${\varphi}^{\prime}=7^{\circ}$.

Parameter Analysis for Design of Pretension Girder Bridge for Urban Maglev Transit (도시형 자기부상열차 프리텐션 거더교의 설계변수 분석)

  • Lee, Jae-Ho;Kim, Do-Hak;Kim, Seung-Hyun;Kim, Sung-Il
    • Journal of the Korean Society for Railway
    • /
    • v.19 no.4
    • /
    • pp.515-525
    • /
    • 2016
  • Parameter analysis of a pretension girder bridge for urban maglev transit was performed to identify the main design parameters and their effect. Girder deflection at mid-span is the most important design criteria of urban maglev transit. Therefore, concrete compressive strength, girder height, girder length, and unbonded tendon length were selected as the design parameters that relate to girder deflection. In addition, tendon layout and unbonded tendon ratios were also considered as design parameters to control the top stress of the pretension girder section at the support. The analysis results show that both the girder height and length are dominant design parameters governing girder deflection, more important than compressive strength and unbounded tendon length. And, sensitivity analysis makes this study suggest design weight value. In terms of stress, a tendon layout that can satisfy the unbounded tendon rule requires an additional tendon or rebar at the upper section to control the tensile stress on top of the section. Therefore, to improve feasibility and constructability in the future, an enhanced unbonded tendon rule considering the load characteristics of the urban maglev system should be studied.

Development of Impact Factor Response Spectrum with Tri-Axle Moving Loads and Investigation of Response Factor of Middle-Small Size-RC Slab Aged Bridges (3축 이동하중을 고려한 충격계수 응답스펙트럼 개발 및 중소규모 RC 슬래브 노후교량 응답계수 분석)

  • Kim, Taehyeon;Hong, Sanghyun;Park, Kyung-Hoon;Roh, Hwasung
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.23 no.2
    • /
    • pp.67-74
    • /
    • 2019
  • In this paper the response factor is investigated for middle and small size-RC slab aged bridges. The response factor consists of static and dynamic response factors and is a main parameter in the frequency based-bridge load carrying capacity prediction model. Static and dynamic response factors are determined based on the frequency variation and the impact factor variation respectively between current and previous (or design) states of bridges. Here, the impact factor variation is figured out using the impact factor response spectrum which provides the impact factor according to the natural frequency of bridges. In this study, four actual RC slab bridges aged over 30 years after construction are considered and their span length is 12m. The dynamic loading test in field using a dump truck and eigenvalue analysis with FE models are conducted to identify the current and previous (or design) state-natural frequencies of the bridges, respectively. For more realistic considerations in the moving loading situation, the impact factor response spectrum is developed based on tri-axle moving loads representing the dump truck load distribution and various supporting conditions such as simply supported and both ends fixed conditions. From the results, the response factor is widely ranged from 0.21to 0.91, showing that the static response factor contributes significantly on the results while the dynamic response factor has a small effect on the result. Compared to the results obtained from the impact factor response spectrum based on the single axle-simply supported condition, the maximum percentage difference of the response factors is below 3.2% only.

Evaluation of Shallow Foundation Behavior on Basalt Rock Layers With Clinker and Sediment Layers Reinforced Using Cement Grouting (현무암층 사이에 존재하는 클링커층과 퇴적층의 시멘트 그라우팅 보강에 따른 얕은 기초 거동 평가)

  • Lee, Kicheol;Shin, Hyunkang;Jung, Hyuksang;Kim, Donghoon;Ryu, Yongsun;Kim, Dongwook
    • Journal of the Korean Geosynthetics Society
    • /
    • v.18 no.3
    • /
    • pp.33-44
    • /
    • 2019
  • Clinker layer is a stratum structure distributed in volcanic area such as Jeju Island. The clinker layers were formed in between the repetitive action of eruption and solidification of lava flows. Since the clinker layer contains a large amount of voids accompanied by the lava gas ejection process, there is a possibility of inducing overall stability of the ground due to the low stiffness and strength of the clinker layer. Therefore, in this study, site investigation was carried out at both ends of the 00 bridge where the clinker layers exist. And, based on the ground survey results, the behavior of shallow foundations was analyzed numerically. In addition, the improved shallow foundation behavior in grouting substitution using the chemical injection method of the clinker layer was compared with the shallow foundation behavior in the ground, and the grouting substitution efficiency of each layer was analyzed. As a result, the bearing capacity, the replacement efficiency and elastic settlement were different according to the presence or absence of the sediment layer. This is because the sediment layer has a lower stiffness and density than the clinker layer.

A Study on the Creation of Digital Self-portrait with Intertextuality (상호텍스트성을 활용한 디지털 자화상 창작)

  • Lim, Sooyeon
    • The Journal of the Convergence on Culture Technology
    • /
    • v.8 no.1
    • /
    • pp.427-434
    • /
    • 2022
  • The purpose of this study is to create a self-portrait that provides an immersive experience that immerses the viewer into the problem of self-awareness. We propose a method to implement an interactive self-portrait by using audio and image information obtained from viewers. The viewer's voice information is converted into text and visualized. In this case, the viewer's face image is used as pixel information composing the text. Text is the result of a mixture of one's own emotions, imaginations, and intentions based on personal experiences and memories. People have different interpretations of certain texts in different ways.The proposed digital self-portrait not only reproduces the viewer's self-consciousness in the inner aspect by utilizing the intertextuality of the text, but also expands the meanings inherent in the text. Intertextuality in a broad sense refers to the totality of all knowledge that occurs between text and text, and between subject and subject. Therefore, the self-portrait expressed in text expands and derives various relationships between the viewer and the text, the viewer and the viewer, and the text and the text. In addition, this study shows that the proposed self-portrait can confirm the formativeness of text and re-create spatial and temporality in the external aspect. This dynamic self-portrait reflects the interests of viewers in real time, and has the characteristic of being updated and created.

Appropriateness Evaluation of Train Vibration Evaluation Method Considering Vibration Levels of Retaining Wall Adjacent to Railway Tunnels (철도터널과 인접한 흙막이 가시설의 진동 수준을 고려한 열차진동 평가방법의 적정성 평가)

  • Donghee Woo;Yeongjin Lee;Yongjae Song;Kangil Lee
    • Journal of the Korean GEO-environmental Society
    • /
    • v.24 no.10
    • /
    • pp.5-13
    • /
    • 2023
  • With the recent increase in development projects centered on urban areas, the construction of building structures is increasing in areas adjacent to the urban railway operation section. In this case, since ground vibration is generated by the train in operation and affects the adjacent structure, the building structure needs appropriate vibration reduction against train vibration generated at the adjacent location from the desing phase. However, the vibration levels calculated vary depending on the train vibration evaluation method, which means that the implementation of vibration reduction may vary depending on the train vibration evaluation method. Therefore, this study calculated the vibration level according to ground conditions, tunnel depth and separation distance between vibration sources and adjacent structures using numerical analysis and train vibration evaluation methods, and compared them to designning phase. And the appropriate separation distance between the tunnel and the adjacent structure was evaluated by comparing the vibration level with the allowable standards. As a result of the study, the Ungar and Bender evaluation method is evaluated as the most appropriate among the train vibration evaluation methods, and the appropriate separation distance between the tunnel and the adjacent structure is evaluated to be more than 4.5D.