• Title/Summary/Keyword: 시간반전성

Search Result 85, Processing Time 0.028 seconds

Understanding the Effects of the Dispersion and Reflection of Lamb Waves on a Time Reversal Process (램파의 분산성과 파 반사가 시간반전과정에 미치는 영향의 이해)

  • Park, Hyun-Woo;Kim, Sung-Bum;Sohn, Hoon
    • Journal of the Computational Structural Engineering Institute of Korea
    • /
    • v.22 no.1
    • /
    • pp.89-103
    • /
    • 2009
  • This study investigates the applicability of the time reversal concept in modem acoustics to the Lamb waves, which have been widely studied for defect detection in plate-like structures. According to conventional time reversal acoustics, an input signal can be reconstructed at an excitation point if an output signal recorded at another point is reversed in the time domain and emitted back to the original source point. However, the application of a time reversal process(TRP) to Lamb wave propagations is complicated due to velocity and amplitude dispersion characteristics of Lamb waves and reflections from the boundaries of a structure. In this study, theoretical investigations are presented to better understand the time reversibility of Lamb waves. In particular, the effects of within-mode dispersion, multimode dispersion, amplitude dispersion, and reflections from boundaries on the TRP are theoretically formulated. Simple numerical case studies are conducted to validate the theoretical findings of this study.

Simulating the Spatial Focusing of Time Reversal Lamb Waves Using Virtual Sensors (가상탐지자를 이용한 시간반전램파의 공간모임 모사)

  • Park, Hyun-Woo
    • Proceedings of the Computational Structural Engineering Institute Conference
    • /
    • 2011.04a
    • /
    • pp.295-298
    • /
    • 2011
  • 최근 3년간 판 구조물의 손상진단에서 시간반전램파 (Time reversal Lamb waves)의 가능성이 주목 받고 있다. 시간반전음향학(Time reversal acoustics)에 의하면 시간반전램파의 공간모임을 적절히 활용하면 판에 순간적으로 가해지거나 발생한 충격하중의 위치를 높은 공간해상도와 신호대 잡음비로 추정할 수 있다고 알려져 있다. 이 연구에서는 시간반전램파의 공간모임을 직사각형 평판에서 가상탐지자 모델을 이용하여 모사한다. 특히, 평판에서의 파 반사에 의해 발생하는 가상탐지자 효과에 의해 단일 부착형 압전소자만을 사용하더라도 시간반전 램파의 공간 모임 구현이 가능함을 보인다. 또한 제안된 방법의 결과를 유한 요소 해석결과와 비교하고 제안된 방법의 타당성을 보인다.

  • PDF

Variation of Asymmetric Hysteresis Loops with Annealing Temperature and Time (열처리 온도와 시간에 따른 비대칭 자기 이력 곡선의 변화)

  • 신경호;민성혜;이장로
    • Journal of the Korean Magnetics Society
    • /
    • v.5 no.4
    • /
    • pp.251-260
    • /
    • 1995
  • It has been reported that Co-based amorphous ferromagnetic alloys annealed in a small magnetic field develop a reproducible, asymmetric hysteresis loop. If the direction of the field during annealing is regarded as +, the magnetization reversal from - to + is smooth and reversible, with its slope determined by the demagnetizing field of the sample. This phenomenon is called the asymmetric magnetization reversal (AMR). The shape of the hyster-esis loop depends sensitively on the condition during the anneal and the alloy composition. Here, we report on the effect of the annealing temperature and time on AMR in a zero magnetostrictive ferromagnetic amorphous alloy. The AMR effect develops in a very short time at a reasonably high temperature, but is stabilized by annealing for a prolonged time.

  • PDF

Investigating the Spatial Focusing of Time Reversal Lamb Waves Using a Virtual Sensor Model on a Rectangular Plate (직사각형 판에서 가상탐지자 모델을 이용한 시간반전램파의 공간모임 규명)

  • Park, Hyun-Woo
    • Journal of the Computational Structural Engineering Institute of Korea
    • /
    • v.24 no.5
    • /
    • pp.553-567
    • /
    • 2011
  • During the last three years, the possibility of the time reversal Lamb waves has been paid attention to for structural health monitoring of a plate. This study proposes a numerical scheme which can simulate the spatial focusing of time reversal Lamb waves on a rectangular plate. In this scheme, a time reversal process is formulated in the frequency domain using active virtual sensors being equivalent to the mirror effects of an actual sensor due to wave reflection on the plate boundary. Forward and backward Lamb wave propagations are represented by scalar functions for simulating the spatial focusing of time reversal Lamb waves. The validity of the proposed scheme is demonstrated through the comparison to the results of finite element analysis in which the spatial focusing of time reversal Lamb waves is realized by wafer-type piezoelectric(PZT) transducers collocated on a rectangular plate.

Numerical Study on Aerodynamic Performance of Counter-rotating Propeller in Hover Using Actuator Method (Actuator 기법을 이용한 제자리 비행하는 동축 반전 프로펠러 공력 성능에 관한 수치적 연구)

  • Kim, Dahye;Park, Youngmin;Oh, Sejong;Park, Donghun
    • Journal of Aerospace System Engineering
    • /
    • v.15 no.3
    • /
    • pp.30-44
    • /
    • 2021
  • Experimental investigation of counter-rotating propellers is subject to multiple time and cost constraint because of additional design parameters unlike single propeller. Also, a lot of computing time and resources are required for numerical analysis due to consideration of the interference between the upper and lower propellers. In the present study, numerical simulations were conducted to investigate the hover performance of counter-rotating propellers by using actuator method which is considered to be time-efficient. The accuracy of the present numerical methods was validated by comparing the ANSYS Fluent which is commercial CFD code. The axial spacing and rotational speed were selected as the analysis variables, and the aerodynamic performance was obtained under various conditions. Based on the obtained results, the Figure of Merit (FM) of single propeller and counter-rotating propellers and a prediction factor which enables prediction of counter-rotating propeller performance using a single propeller were derived to evaluate availability of the actuator method.

The Effect of Anticholinergic Agents on Postoperative Sore Throat in Patients Undergoing Endoscopic Sinus Surgery (내시경적 부비동 수술 시 항콜린성제제 사용이 수술 후 인후통 발생에 미치는 영향)

  • Lee, Joo-Young;Lee, Deok-Hee
    • Journal of Yeungnam Medical Science
    • /
    • v.24 no.2
    • /
    • pp.305-310
    • /
    • 2007
  • Background : After sinus surgery, airway dryness is made worse because patients breathe by mouth. Anticholinergic agents have antisialogogue effects. The airway dryness that occurs after surgery is severe and can increase the incidence of postoperative sore throat. Materials and Methods : One-hundered patients who were scheduled for endoscopic sinus surgery(ESS) were divided into four groups. Each group was premedicated with glycopyrrolate or had no premedication and reversed with glycopyrrolate or atropine. After the surgery the patients were asked about a sore throat and hoarseness postoperatively after 1h, 6h, 12h, 24h, and 48hours, respectively. Results : The incidence of postoperative sore throat and hoarseness was not significantly different among the four groups at any time. Conclusion : The severity of complications after ESS was low and subsided within 24 hours. Therefore, the use of anticholinergic agents does not need to be limited.

  • PDF

Investigating the Spatial Focusing Performance of Time Reversal Lamb Waves on a Plate through the Finite Element Method (유한요소법을 통한 판에서 시간반전 램파의 공간집속성능 규명)

  • Choi, Jeong-Hee;Lee, Hae-Sung;Park, Hyun-Woo
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.21 no.12
    • /
    • pp.1120-1131
    • /
    • 2011
  • Researches using time reversal acoustics(TRA) for impact localization have been paid attention to recently. Dispersion characteristics of Lamb waves, which restrict the utility of classical nondestructive evaluation based on time-of-flight information, can be compensated through the application of TRA to Lamb waves on a plate. This study investigates the spatial focusing performance of time reversal Lamb waves on a plate using finite element analysis. In particular, the virtual sensor effect caused by multiple wave reflections at the boundaries of a plate is shown to enable the spatial focusing of Lamb waves though a very small number of surface-bonded piezoelectric(PZT) sensors are available. The time window size of forward response signals, are normalized with respect to the number of virtual active sensors. Then their effects on the spatial focusing performance of Lamb waves are investigated.

Investigating the spatial focusing performance of time reversal Lamb waves on a plate with respect to input source location and the number of sensors (입력소스의 위치와 센서개수에 따른 평판에서의 시간반전램파의 공간집속성능 규명)

  • Seo, dae jae;Park, huyn woo
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2014.04a
    • /
    • pp.722-725
    • /
    • 2014
  • The spatial focusing of time reversal Lamb waves on a plate has attracted considerable attention for identifying the location of an input source. This study investigates the spatial focusing performance on a plate with respect to the number of piezoelectric (PZT) sensors for varying locations of input sources. In particular, a small number of PZT sensors produce spatial focusing through the virtual sensor effect due to reflection of Lamb waves at plate edges. The spatial focusing performance with respect to the number of PZT sensors is quantified in terms of signal to noise ratio through numerical simulation and its implication is discussed.

  • PDF

Structural Damage Detection by Using the Time-Reversal Process of Lamb Waves and the Imaging Method (Lamb파의 시간-반전과정 및 이미지기법을 이용한 손상탐지)

  • Jun, Yong-Ju;Lee, U-Sik
    • Journal of the Korean Society for Railway
    • /
    • v.14 no.4
    • /
    • pp.320-326
    • /
    • 2011
  • This paper proposes a baseline-free SHM technique in which the time-reversal process of Lamb waves and the imaging method are used. The proposed SHM technique has three distinct features when compared with the authors' previously proposed one: (1) It use the reconstructed signal for damage diagnosis, without need to extract the damage signal as the difference between reconstructed signal and initial input signal; (2) It use the imaging method based on the time-offlight information from the reconstructed signal, instead of using a pattern comparison method; (3) In order to make the damage image more clear, the modified mathematical definition of damage image in a pixel is used. The proposed SHM technique is evaluated through the damage detection experiment for an aluminum plate with damage at different locations.

The Molecular Weight Dependance of Paramagnetic Gd-chelates on T1 and T2 Relaxation Times (상자성 복합체의 분자량에 따른 T1 및 T2 자기이완시간에 관한 연구)

  • Kim In-Sung;Lee Young-Ju;Kim Ju-Hyun;Sujit Dutta;Kim Suk-Kyung;Kim Tae-Jeong;Kang Duk-Sik;Chang Yong-Min
    • Progress in Medical Physics
    • /
    • v.17 no.2
    • /
    • pp.61-66
    • /
    • 2006
  • To evaluate the T1, T2 magnetic relaxation properties of water molecule according to molecular weight of paramagnetic complex. 4-aminomethyicyclohexane carboxylic acid (0.63 g, 4 mmol) was mixed with the suspension solution of DMF (15 ml) and DTPA-bis-anhydride (0.71 g, 2 mmol) to synthesize the ligand. The ligand was then mixed with $Gd_2O_3$ (0.18 g, 0.5 mmol) to synthesize Gd-chelate. For the measurement of magnetic relaxivity of paramagnetic compounds, the compounds were diluted to 1 mM and then the relaxation times were measured at 1.57 (64 MHz). Inversion-recovery pulse sequence was employed for T1 relaxation measurement and CPMG (Carr-Purcell-Meiboon-Gill) pulse sequence was employed for T2 relaxation measurement. In case of inversion recovery sequence, total 35 images with different inversion time(T1)s ranging from 50 msec to 1,750 msec. To estimate the relaxation times, the signal intensity of each sample was measured using region of Interest (ROI) and then fitted by non-linear least square method to yield T1, T2 relaxation times and also R1 and R2. Compared to T1=($205.1{\pm}2.57$) msec and T2=($209.4{\pm}4.28$) msec of Omniscan (Gadodiamide), which is commercially available paramagnetic MR agent, T1 and T2 values of new paramagnetic complexes were reduced along with their molecular weight. That is, T1 value was ranged from $(96.35{\pm}2.04)\;to\;(79.38{\pm}1.55)$ msec and T2 value was ranged from $(91.02{\pm}2.08)\;to\;(76.66{\pm}1.84)$ msec. Among new paramagnetic complexes, there is a tendency that the R1 and R2 increase as the molecular weight is increases. As molecular weight of paramagnetic complex increases, T1 and T2 relaxation times reduce and thus the increase of relaxivity (R1 and R2) Is proportional to molecular weight.

  • PDF