• Title/Summary/Keyword: 시간과 움직임

Search Result 672, Processing Time 0.022 seconds

A Study of the Health Promoting Life Style in Rural Area (일부 농촌주민의 건강증진 생활양식 수행정도)

  • Jung, Young-Ok;Kim, Sang-Soon
    • Journal of agricultural medicine and community health
    • /
    • v.20 no.2
    • /
    • pp.133-148
    • /
    • 1995
  • This study was to identify the factors affecting the performance in health promoting lifestyle and measuring health promoting lifestyle. The subjects for this study were all adult in rural area, Kakbuk Nyun, Chung-do Gun, Kyungpook, Korea. The data were collected during the period from April 1 to April 30, 1995. The instruments used for this study were the health promoting lifestyle by Park(1995). The results of this study are as follows. Health condition felt by the subjects was worse in female group and was getting worse according as the age increase. According to health promoting life style implementation questionnaire, more than half of the subjects responded "never" in deep breathing 3 times a day item and non-smoking item; more than half of the subjects responded "yes" in 3 meal a day item, home-cooked meals item, never to omit breakfast item and frequent wearing of cotton underwear item. Health promoting life style implementation by health condition is higher in healthy group and frequency of consulting a specialist is higher in unhealthy group. Health promoting life style implementation by sex is higher in male group. Frequency, of consulting a specialist and non-excessive drinking are higher in female group. Health promoting life style implementation by age showed that the implementation of never omitting breakfast, keeping early hours and proper sleeping is higher in old age group ; that of enjoying hobby, pastime, cleaning as well as reading health books is higher in young age group. Health promoting life style implementation by religion showed that the implementation of deep breathing 3 times more a day, regular checking of blood pressure, never having non-healthful food and keeping right posture in sitting and standing is higher in religion group. Health promoting life style implementation by education is higher in highly-educated group ; the implementation of keeping early hours is higher in low-educated group. Health promoting life style implementation by marriage state showed that the implementation of deep breathing 3 times more a day, twenty minutes of brisk physical movement three or four times a week, enjoying his or her own time, relaxation to relieve from tension and pressure and equalized movement of each part of body is higher in unmarred group ; that of having elaborately cooked food, never omitting three meals a day and keeping early hours is higher in married group. Health promoting life style implementation by the number of family members showed that more-member-group has more plans and objectives for their future. Health promoting life style implementation by family type showed that the implementation of reading health books and articles, living with positive way of thinking and enjoying favorite hobby in pastime is higher in nuclear families ; that of having three meals a day never omitting breakfast is higher in large families.

  • PDF

System Development for Measuring Group Engagement in the Art Center (공연장에서 다중 몰입도 측정을 위한 시스템 개발)

  • Ryu, Joon Mo;Choi, Il Young;Choi, Lee Kwon;Kim, Jae Kyeong
    • Journal of Intelligence and Information Systems
    • /
    • v.20 no.3
    • /
    • pp.45-58
    • /
    • 2014
  • The Korean Culture Contents spread out to Worldwide, because the Korean wave is sweeping in the world. The contents stand in the middle of the Korean wave that we are used it. Each country is ongoing to keep their Culture industry improve the national brand and High added value. Performing contents is important factor of arousal in the enterprise industry. To improve high arousal confidence of product and positive attitude by populace is one of important factor by advertiser. Culture contents is the same situation. If culture contents have trusted by everyone, they will give information their around to spread word-of-mouth. So, many researcher study to measure for person's arousal analysis by statistical survey, physiological response, body movement and facial expression. First, Statistical survey has a problem that it is not possible to measure each person's arousal real time and we cannot get good survey result after they watched contents. Second, physiological response should be checked with surround because experimenter sets sensors up their chair or space by each of them. Additionally it is difficult to handle provided amount of information with real time from their sensor. Third, body movement is easy to get their movement from camera but it difficult to set up experimental condition, to measure their body language and to get the meaning. Lastly, many researcher study facial expression. They measures facial expression, eye tracking and face posed. Most of previous studies about arousal and interest are mostly limited to reaction of just one person and they have problems with application multi audiences. They have a particular method, for example they need room light surround, but set limits only one person and special environment condition in the laboratory. Also, we need to measure arousal in the contents, but is difficult to define also it is not easy to collect reaction by audiences immediately. Many audience in the theater watch performance. We suggest the system to measure multi-audience's reaction with real-time during performance. We use difference image analysis method for multi-audience but it weaks a dark field. To overcome dark environment during recoding IR camera can get the photo from dark area. In addition we present Multi-Audience Engagement Index (MAEI) to calculate algorithm which sources from sound, audience' movement and eye tracking value. Algorithm calculates audience arousal from the mobile survey, sound value, audience' reaction and audience eye's tracking. It improves accuracy of Multi-Audience Engagement Index, we compare Multi-Audience Engagement Index with mobile survey. And then it send the result to reporting system and proposal an interested persons. Mobile surveys are easy, fast, and visitors' discomfort can be minimized. Also additional information can be provided mobile advantage. Mobile application to communicate with the database, real-time information on visitors' attitudes focused on the content stored. Database can provide different survey every time based on provided information. The example shown in the survey are as follows: Impressive scene, Satisfied, Touched, Interested, Didn't pay attention and so on. The suggested system is combine as 3 parts. The system consist of three parts, External Device, Server and Internal Device. External Device can record multi-Audience in the dark field with IR camera and sound signal. Also we use survey with mobile application and send the data to ERD Server DB. The Server part's contain contents' data, such as each scene's weights value, group audience weights index, camera control program, algorithm and calculate Multi-Audience Engagement Index. Internal Device presents Multi-Audience Engagement Index with Web UI, print and display field monitor. Our system is test-operated by the Mogencelab in the DMC display exhibition hall which is located in the Sangam Dong, Mapo Gu, Seoul. We have still gotten from visitor daily. If we find this system audience arousal factor with this will be very useful to create contents.

Real-time Body Surface Motion Tracking using the Couch Based Computer-controlled Motion Phantom (CBMP) and Ultrasonic Sensor: A Feasibility Study (CBMP (Couch Based Computer-Controlled Motion Phantom)와 초음파센서에 기반한 실시간 체표면 추적 시스템 개발: 타당성 연구)

  • Lee, Suk;Yang, Dae-Sik;Park, Young-Je;Shin, Dong-Ho;Huh, Hyun-Do;Lee, Sang-Hoon;Cho, Sam-Ju;Lim, Sang-Wook;Jang, Ji-Sun;Cho, Kwang-Hwan;Shin, Hun-Joo;Kim, Chul-Yong
    • Progress in Medical Physics
    • /
    • v.18 no.1
    • /
    • pp.27-34
    • /
    • 2007
  • Respiration sating radiotherapy technique developed In consideration of the movement of body surface and Internal organs during respiration, is categorized into the method of analyzing the respiratory volume for data processing and that of keeping track of fiducial landmark or dermatologic markers based on radiography. However, since these methods require high-priced equipments for treatment and are used for the specific radiotherapy. Therefore, we should develop new essential method whilst ruling out the possible problems. This study alms to obtain body surface motion by using the couch based computer-controlled motion phantom (CBMP) and US sensor, and to develop respiration gating techniques that can adjust patients' beds by using opposite values of the data obtained. The CBMP made to measure body surface motion is composed of a BS II microprocessor, sensor, host computer and stopping motor etc. And the program to control and operate It was developed. After the CBMP was adjusted by entering random movement data, and the phantom movements were acquired using the sensors, the two data were compared and analyzed. And then, after the movements by respiration were acquired by using a rabbit, the real-time respiration gating techniques were drawn by operating the phantom with the opposite values of the data. The result of analysing the acquisition-correction delay time for the data value shows that the data value coincided within 1% and that the acquistition-correction delay time was obtained real-time $(2.34{\times}10^{-4}sec)$. And the movement was the maximum movement was 6 mm In Z direction, In which the respiratory cycle was 2.9 seconds. This study successfully confirms the clinical application possibility of respiration gating techniques by using a CBWP and sensor.

  • PDF

Evaluation of Set-up Accuracy for Frame-based and Frameless Lung Stereotactic Body Radiation Therapy (폐암 정위체부방사선치료 시 고정기구(frame) 사용 유무에 따른 셋업 정확성 평가)

  • Ji, Yunseo;Chang, Kyung Hwan;Cho, Byungchul;Kwak, Jungwon;Song, Si Yeol;Choi, Eun Kyung;Lee, Sang-wook
    • Progress in Medical Physics
    • /
    • v.26 no.4
    • /
    • pp.286-293
    • /
    • 2015
  • The purpose of this study was to evaluate the set up accuracy using stereotactic body frame and frameless immobilizer for lung stereotactic body radiation therapy (SBRT). For total 40 lung cancer patients treated by SBRT, 20 patients using stereotactic body frame and other 20 patients using frameless immobilizer were separately enrolled in each group. The setup errors of each group depending on the immobilization methods were compared and analyzed. All patients received the dose of 48~60 Gy for 4 or 5 fractions. Before each treatment, a patient was first localized to the treatment isocenter using room lasers, and further aligned with a series of image guidance procedures; orthogonal kV radiographs, cone-beam CT, orthogonal fluoroscopy. The couch shifts during these procedures were recorded and analyzed for systematic and random errors of each group. Student t-test was performed to evaluate significant difference depending on the immobilization methods. The setup reproducibility was further analyzed using F-test with the random errors excluding the systematic setup errors. In addition, the ITV-PTV margin for each group was calculated. The setup errors for SBF were $0.05{\pm}0.25cm$ in vertical direction, $0.20{\pm}0.38cm$ in longitudinal direction, and $0.02{\pm}0.30cm$ in lateral direction, respectively. However the setup errors for frameless immobilizer showed a significant increase of $-0.24{\pm}0.25cm$ in vertical direction while similar results of $0.06{\pm}0.34cm$, $-0.02{\pm}0.25cm$ in longitudinal and lateral directions. ITV-PTV margins for SBF were 0.67 cm (vertical), 0.99 cm (longitudinal), and 0.83 cm (lateral), respectively. On the other hand, ITV-PTV margins for Frameless immobilizer were 0.75 cm (vertical), 0.96 cm (longitudinal), and 0.72 cm (lateral), indicating less than 1 mm difference for all directions. In conclusion, stereotactic body frame improves reproducibility of patient setup, resulted in 0.1~0.2 cm in both vertical and longitudinal directions. However the improvements are not substantial in clinic considering the effort and time consumption required for SBF setup.

Development of Movement Analysis Program and its Feasibility Test in Streotactic Body Radiation Threrapy (복부부위의 체부정위방사선치료시 호흡에 의한 움직임분석 프로그램 개발 및 유용성 평가)

  • Shin, Eun-Hyuk;Han, Young-Yih;Kim, Jin-Sung;Park, Hee-Chul;Shin, Jung-Suk;Ju, Sang-Gyu;Lee, Ji-Hea;Ahn, Jong-Ho;Lee, Jai-Ki;Choi, Doo-Ho
    • Progress in Medical Physics
    • /
    • v.22 no.3
    • /
    • pp.107-116
    • /
    • 2011
  • Respiratory gated radiation therapy and stereotactic body radiation therapy require identical tumor motions during each treatment with the motion detected in treatment planning CT. Therefore, this study developed a tumor motion monitoring and analysis system during the treatments employing RPM data, gated setup OBI images and a data analysis software. A respiratory training and guiding program which improves the regularity of breathing was used to patients. The breathing signal was obtained by RPM and the recorded data in the 4D console was read after treatment. The setup OBI images obtained gated at 0% and 50% of breathing phases were used to detect the tumor motion range in crenio-caudal direction. By matching the RPM data recorded at the OBI imaging time, a factor which converts the RPM motion to the tumor motion was computed. RPM data was entered to the institute developed data analysis software and the maximum, minimum, average of the breathing motion as well as the standard deviation of motion amplitude and period was computed. The computed result is exported in an excel file. The conversion factor was applied to the analyzed data to estimate the tumor motion. The accuracy of the developed method was tested by using a moving phantom, and the efficacy was evaluated for 10 stereotactic body radiation therapy patients. For the sine wave motion of the phantom with 4 sec of period and 2 cm of peak-to-peak amplitude, the measurement was slightly larger (4.052 sec) and the amplitude was smaller (1.952 cm). For patient treatment, one patient was evaluated not to qualified to SBRT due to the usability of the breathing, and in one patient case, the treatment was changed to respiratory gated treatment due the larger motion range of the tumor than treatment planed motion. The developed method and data analysis program was useful to estimate the tumor motion during treatment.

Prediction of Target Motion Using Neural Network for 4-dimensional Radiation Therapy (신경회로망을 이용한 4차원 방사선치료에서의 조사 표적 움직임 예측)

  • Lee, Sang-Kyung;Kim, Yong-Nam;Park, Kyung-Ran;Jeong, Kyeong-Keun;Lee, Chang-Geol;Lee, Ik-Jae;Seong, Jin-Sil;Choi, Won-Hoon;Chung, Yoon-Sun;Park, Sung-Ho
    • Progress in Medical Physics
    • /
    • v.20 no.3
    • /
    • pp.132-138
    • /
    • 2009
  • Studies on target motion in 4-dimensional radiotherapy are being world-widely conducted to enhance treatment record and protection of normal organs. Prediction of tumor motion might be very useful and/or essential for especially free-breathing system during radiation delivery such as respiratory gating system and tumor tracking system. Neural network is powerful to express a time series with nonlinearity because its prediction algorithm is not governed by statistic formula but finds a rule of data expression. This study intended to assess applicability of neural network method to predict tumor motion in 4-dimensional radiotherapy. Scaled Conjugate Gradient algorithm was employed as a learning algorithm. Considering reparation data for 10 patients, prediction by the neural network algorithms was compared with the measurement by the real-time position management (RPM) system. The results showed that the neural network algorithm has the excellent accuracy of maximum absolute error smaller than 3 mm, except for the cases in which the maximum amplitude of respiration is over the range of respiration used in the learning process of neural network. It indicates the insufficient learning of the neural network for extrapolation. The problem could be solved by acquiring a full range of respiration before learning procedure. Further works are programmed to verify a feasibility of practical application for 4-dimensional treatment system, including prediction performance according to various system latency and irregular patterns of respiration.

  • PDF

Semiological Implication of Dance Images in TV Advertisement (TV광고에 나타난 무용이미지의 기호학적 의미에 관한 연구)

  • Park, Ayoung
    • Trans-
    • /
    • v.1
    • /
    • pp.21-44
    • /
    • 2016
  • Advertisement is composed with symbol and sign with messages trying to express. Especially, ad with dancer introduces goods or meaning of contents with the motion of dance. In this, contents of dance or motion of dancer contains symbol and sign, understanding how ad and dance are expressed meanings with which symbol and the symbolic meaning of dance or dancer on ad. To that end, this study is for analyzing expressed symbol with dance corresponds with the aim of ad and finding the way or attitude of how normal people accept dance by reevaluating symbolic meaning of dance itself. In this study, advertisement producer and director's related data is secured for understanding direction and intention of producer, and previous study related with the study purpose, image, and effect are analyzed for understanding image of dance as a physical sign on TV advertisement. With data from www.TVCF.co.kr. TV advertisement analysis is conducted only with four ads in 2008(Nam Kwang Eng. & Const Co., Lotte Dept. Store(premium sale/gift card), Hyundai Motor Company Santa Fe -Pilobolus) and one ad in 2011(PNS The zone Sash Italy Arena di Verona when dance was used for advertisement with the highest frequency per year. Also, based on considered important factors from repeatedly watching each advertisement, scenes where movement or motion of dancer and screen word is greatly changed are analyzed as a priority. Image analysis of dance is conducted with structure studies based on physical image(line, costume, expression) and dan image(type motion, qualitative feature, mood of dance). As a result, the symbolic dance image appeared in TV advertisement can be discussed as follows. First, symbol and sign of dance on advertisement corresponds with material objects of advertisement. For instance, on the TV advertisement where Lee Youngwoo appeared, his motion as a signifer means challenge for the future of Nam Kwang Eng. & Const Co., with fast turn, jump, assemble turning jump, and sliding. Second, physical image of dancer depending on intention of sender corresponds in general, but there are somewhat differences in image of dance. This makes people to unconsciously recognize symbolic image of dance on TV ad while they watch it at the same time. Especially, when it comes to advertisement, it exposes frequently with broadcasting of organized programs from a broadcaster, living long-time memory. It can be differ based on idea and character of each of receiver. Advertisement is a medium making people naturally adopt cultural art for ordinary people in their lives. Broadcasting public art from TV advertisement widely exposes pure art to people, which was only avaliable for minority, sublimating it as an art of public culture.

  • PDF

A Study on the Efficiency of Hand-Knee Position in GB Stone Ultrasonography (담낭결석 초음파검사에서 Hand-Knee position의 효율성에 관한 연구)

  • Park, Soung-Ock;Do, Yun-Su
    • Journal of radiological science and technology
    • /
    • v.29 no.4
    • /
    • pp.267-274
    • /
    • 2006
  • The evaluation of GB stones with ultrasound has proved to be useful procedure in patient with symptoms of cholelithiasis. GB is evaluated for size, wall thickness, presence of internal reflections within the lumen and posterior acoustic shadowing or enhancement in Ultrsonography. The patient position should be shifted during procedure to demonstrate further the presence of stone within the GB. Patient scanned at the Rt. subcostal region in supine, right lateral, Lt. down decubitus, and upright sitting position. So GB stone should shift to dependent area of GB. Often, GB is not markedly distended in the presence of cholethiasis, and so the diagnosis becomes more difficult. One of the more difficult areas for detection of a GB stones are embeded in the cystic duct region. And since the GB is adjacent to the duodenum and hepatic flexure, its may be difficult to visualizing a GB stone. When patient study position changes frome supine to other position, stones displaced the site. But if its are polyps, not changes the site whatever patient positions. It is very important to what make different GB stones or polyps. We have studied about mobility of GB stones according to the patients position(supine, Lt. down decubitus, $30^{\circ} LAO. sitting and hand-knee). So we have a result, stones wherever localized within the GB, changed 100% its position in the hand-knee position and the others appeared at least 90%. In this study, when a large stones are located through fundus-body and body-neck, does not changing the stones position in spite of varied patient's positions. But hand-knee positions can identified GB stones, because its make changed the position of stons from posterior wall to anterior wall within the GB. We recommend the hand-knee position for differentiation GB stones from polyps.

  • PDF

The Effects of Weighted Vest During Task-Oriented Training on Gross Motor Performance and Balance Abilities of Children With Spastic Diplegia : A Randomized Clinical Trial Study (경직형 양마비 아동의 과제지향훈련 시 무게조끼 적용이 대동작 수행력과 균형 능력에 미치는 영향: 무작위배정 위약비교 연구)

  • Kwon, Hae-Yeon
    • The Journal of Korean Academy of Sensory Integration
    • /
    • v.15 no.2
    • /
    • pp.46-65
    • /
    • 2017
  • Objective : The purpose of this research is to find clinical effects of application of weighted vest during task-oriented training focused on gross motor performance and balance abilities of children with spastic diplegia. Methods : 34 subjects were divided by simple random sampling into two groups; experimental group (male : 9, female : 8, average age : 8.12) and placebo group (male : 9, female : 9, average age : 7.53). Both two groups underwent to 40 minute intervention, twice a week for 12 weeks. The intervention was task-oriented training focused on facilitating closed kinematic chain and multi-joint functional movement pattern. During the training, the experimental group received loaded-resistance weighted vest and placebo group also received weighted vest but without loaded-resistance. Participants in both groups underwent 8 to 10 reps of the task-oriented training and there were 3 minutes break time between tasks. There were pre-test of gross motor performance and balance abilities, and two times of post-tests were performed upon 6 weeks and 12 weeks after the intervention completed. And in final, an additional follow-up test was performed 12 weeks after the evaluation was finished in order to find any difference between the two groups over time. Results : There was significant difference in Gross Motor Performance Measure (GMPM) between two groups. It is found that average score of the experimental group increased more than the placebo group after 6 weeks and 12 weeks intervention (p<.05). There was significant difference in Pediatric Berg's Balance Scale (PBS) between two groups. It is found that average score of the experimental group increased more than the placebo group after 6 weeks and 12 weeks intervention (p<.05). Conclusion : Based on the results in this study, it is proposed that application of weighted vest into task-oriented training to facilitating closed kinematic chain and multi-joint movement can improve gross motor performance and balance abilities of children with cerebral palsy.

Comparison of Doses of Single Scan PBS and Layered Rescanning PBS Using Moving Phantom in Proton Therapy (양성자 치료에서 Moving Phantom을 이용한 Single Scan PBS와 Layered Rescanning PBS의 선량비교)

  • Kim, Kyeong Tae;Kim, Seon Yeong;Kim, Dae Woong;Kim, Jae Won;Park, Ji Yeon;Jeon, Sang Min
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.31 no.1
    • /
    • pp.43-49
    • /
    • 2019
  • Purpose : We apply the Layered Rescanning PBS designed to complement the Pencil Beam Scanning(PBS), which is vulnerable to moving organs with the Moving Phantom, and compare the homogeneity with the single scan PBS. Methods and materials: Matrix X (IBA, Belgium) and Moving Phantom (standard imaging, USA) were used. A dose of 200 cGy was measured in the AP direction on a hypothetical tumor $10{\times}10{\times}5cm$. The plan type was planned as 4 kinds of sinlge scan PBS, rescan number 4, 8, 12 times. Were measured three times for each types. During the measurement, the respiratory cycle of the Moving Phantom was generally set to 4 seconds per cycle, and the movement radius in the S-I direction was set to 2 cm. In addition, beam on time was measured. Results : The mean values of $D_{max}$ in the PTV were $246.47{\pm}18.8cGy$, $223.43{\pm}8.92cGy$, and $222.47{\pm}7.7cGy$, $213.9{\pm}6.11cGy$ and the mean values of $D_{min}$ were $165.53{\pm}4.32cGy$, $173.13{\pm}11.94cGy$, $184.13{\pm}8.04cGy$, $182.67{\pm}4.38cGy$ and the mean values of $D_{mean}$ $192.77{\pm}6.98cGy$, $196.7{\pm}4.01cGy$, $198.17{\pm}4.96cGy$, $195.77{\pm}3.15cGy$ respectively. As the number of rescanning increased, the Homogeneity Index converged to 1. The beam on time was measured as 2:15, 3:15, 4:30, 5:37 on average. In the measurement process, in the low dose layer of the MU, the problem was found that it was not rescanned as many times as the set number of rescan. Conclusions : In the treatment of tumors with long-term movements, the application of layered rescanning PBS showed a more uniform dose distribution than single scan PBS. And as the number of rescan increase, the distribution of homogeneity is uniform. Compared with single scan plan and 12 rescan plan, HI value was improved by 0.32. Further studies are expected to be applicable to patients who can not be treated with respiratory synchronous radiation therapy.