• Title/Summary/Keyword: 승객대피

Search Result 49, Processing Time 0.027 seconds

Time-Space Variability Analysis for the Weekly Passenger Flow of the Seoul Subway System: Based on Dynamic Visualization Methods (서울 대도시권 지하철 통행흐름의 요일 간 변이성 분석: 동적 시각화방법을 토대로)

  • Lee, Keumsook;Kim, Ho Sung;Park, Jong Soo
    • Journal of the Economic Geographical Society of Korea
    • /
    • v.20 no.2
    • /
    • pp.158-172
    • /
    • 2017
  • This study analyzes the time-space variability for the weekly passenger flow of the Seoul Subway system based on the dynamic visualization methods. For the purpose, we utilize one-week T-card transaction databases. By applying data mining algorithms, we extract passenger data for edge flows, on/off passengers at each subway station per minute interval time. It is practically intractable to analyze such spatio-temporal passenger flows by general statistical techniques. We employ dynamic visualization methods to analyze intuitively and to grasp effectively characteristics of the diurnal passenger flows on the Seoul Metropolitan Subway system during one week. As the result, we found that substantial differences exist on the spatio-temporal distribution patterns among days as well as between weekdays and weekend. We also investigates the time-space variability among eight major centers, and we found wide differences in their spatio-temporal distribution patterns.

A Study on Smoke Extract Vents in a Subway with Screen door by Evacuation Performance Evaluation through RSET vs. ASET based on Computer Simulations (스크린도어가 설치된 지하철 승강장의 대피안전성 평가를 통한 제연환기구의 방재성능 개선방안 연구)

  • Park, Hyung-Joo;Lee, Young-Jae;Shin, Dong-Cheol;Baek, Dong-Ho
    • Journal of the Korean Society for Railway
    • /
    • v.10 no.5
    • /
    • pp.511-519
    • /
    • 2007
  • This study provides comprehensive design improvements covering technical issues concerning life safety matter In case of fire train stoppage in the middle of a tunnel. Recently Government announced that most of subway platforms will have screen doors in 3 years. Therefore, many fire safety engineers considered that they may contribute on life safety on train stoppage in tunnel. Especially The screen door can protect platform from smoke along tunnel ceiling when fire train stopped in tunnel. The study showed that platform ventilation ducts and the a tunnel ventilation chimney in the middle of tunnel in exiting subway tunnel could not guarantee life safety ability in terms of RSET vs. ASET comparison. Furthermore during evacuation process many peoples may be threatened from the smoke spread from the origin of fire. Although only additional vertical route can be installed in tunnels In order to decrease RSET, it will costs high or no spaces remains in outside on the road. The study suggested that increase of ASET can be best solution without additional escape route, therefore alternative design methods suggested on the base of simulation results. Finally the study shows alternative methods can give good result in terms of evacuation performance evaluation. The evacuation performance evaluation helps the decision-maker to determine the preferred alternatives or upgrades to existing tunnel infrastructure and other measure to meet safety objectives. Finally, the study details the effectiveness of measures the can be taken to reduce the risk of incidents in subway tunnels.

Experimental Investigation about Optimum Smoke Extraction System for Underground Station (축소 모형 실험을 통한 정거장내 적정 배연방식에 관한 연구)

  • Lee, Ho-Keun;Kim, Myoung-Woo;Lee, Phill-Young;Kim, Nam-Suk
    • Journal of the Korean Society of Hazard Mitigation
    • /
    • v.8 no.4
    • /
    • pp.53-59
    • /
    • 2008
  • If fire is occurred in the subway, the train must be moved to the closest station and make passengers get off the train. As a matter of fact, the Fire of Dae-gu Subway was coped with this way. But, the fire smoke extraction system of real subway stations have not designed to deal with fire of trains yet. Therefore, we have to establish a plan of station railroad for preventing from unexpected damage when the fired train comes to the station. The purpose of this study is to establish the effective smoke extraction measure that is to prevent stations from damage by the scale-down experiment.

Synchronization of the Train PIS using the reference clock and development of a subtitle authoring tool (레퍼런스 클럭을 이용한 객차 PI 시스템 동기화 및 자막 편집기 개발)

  • Kim, Jung-Hoon;Jang, Dong-Wook;Han, Kwang-Rok
    • Journal of the Korea Society of Computer and Information
    • /
    • v.12 no.4
    • /
    • pp.1-10
    • /
    • 2007
  • This paper describes the development of a network-based passenger information system(PIS) which provides the convenience of the passenger of the train and heightens the effect of the subtitle service, the advertising and the shelter guidance broadcasting against the urgent event. The existing system uses VGA signal distributor in order to broadcast information with image and subtitle and voice guidance. In this paper we improve the existing system by applying the UDP and TCP/IP protocol and use a reference clock to solve a data loss and synchronization problem which occurs in this case. We also developed an XML-based subtitle authoring tool which can edit and play the subtitles with various 3D to improve the automatic guidance broadcasting and advertisement effect according to the operation schedule of the train. The system performance was evaluated through a simulation.

  • PDF

A study on safety evaluation by changing smoke ventilation mode in subway tunnels (지하철터널 환기변환모드에 따른 안전성 평가에 관한 연구)

  • Rie, Dong-Ho
    • Journal of Korean Tunnelling and Underground Space Association
    • /
    • v.5 no.4
    • /
    • pp.389-400
    • /
    • 2003
  • In order to recommend the mechanical smoke exhaust operation mode, Subway Environmental Simulation (SES) is used to predict the airflow of the inlet and outlet tunnel for the subway station. Fire Dynamic Simulation (FDS) is used the SES's velocity boundary conditions to clarity the smoke exhaust effectiveness by the variations with mechnical ventilation system. We compared each 6 types of smoke exhaust systems for the result of smoke density and temperature distributions for 1.5m height from the subway station base in order to clarify the safety evaluation for the heat and smoke exhaust on subway fire.

  • PDF

A Conceptual Study on Disaster Detection and Response System (재난전조 감지 및 재난대응 시스템에 관한 개념연구)

  • Park, Mi-yun;Koo, Won-yong;Park, Wan-soon;Kwon, Se-gon
    • Journal of Korean Society of Disaster and Security
    • /
    • v.7 no.2
    • /
    • pp.35-41
    • /
    • 2014
  • If a disaster occurs in the underground like subway, disaster response system should minimize the casualties. It must quickly guide passengers to a safe evacuation route. But sometimes the system does not work properly. And then they need distributed disaster response system which make decision autonomously. We perform conceptual research about distributed autonomous decision-making disaster detection and response system and disaster detection method.

A study on the rescue design of passengers for railway tunnel fire accidents by using simulation program (터널 화재발생시 시뮬레이션 프로그램을 통한 승객대피계획)

  • Kwon, Soon-Sub;Lee, Jong-Sun;Lee, Kwan-Ho;Kwon, Woo-Sung
    • Proceedings of the KSR Conference
    • /
    • 2007.05a
    • /
    • pp.1770-1773
    • /
    • 2007
  • Fire accident in tunnel is one of the most critical railway accidents, together with overturning of train by derailment and train crash. Tunnel structures contribute to minimize the cost and time of transport, but in case of railway fire accident occurring bring serious damages of human life caused by narrowness of shelter, poisonous smoke and high temperature raised at the inside of tunnel. For that reason, at the beginning of plan of tunnel, the optimum design for rescue of passengers is needed. For the detail and most suitable design for rescue of passengers, many tunnel designer substituted simulation program for mock examination by its high cost and effort. In this study, simulation program techniques, such as Fluent and Simulex, are applied for verifying the rescue design of passengers reduced the risk when fire accident occurred at tunnel utilizing of case study for planned railway tunnels shows 1,245m length in Iksan-Sili area.

  • PDF

The Study for PAGA Coverage Requirements and Analysis Procedure (선박 및 해양플랜트 PAGA Coverage Rule Study 및 해석 사례)

  • Lee, Sung-Ju;Park, Hyung-Sik;Park, No-Jun;Kwun, Hyuk;Suh, Yong-Suk;Seo, Jong-Soo
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2014.10a
    • /
    • pp.20-22
    • /
    • 2014
  • 선박, 해양플랜트에 적용되는 PAGA System 는 선내 모든 선원 및 승객에 대하여 정보전달 기능뿐 아니라 위급 상황 발생시 신속한 상황 전달 및 대피를 위한 안전상의 이유로서 매우 중요시 되고 있다. PAGA 의 핵심이 되는 Audio Coverage 의 경우, 초기 설계단계에서 해석을 통해 스피커 배치가 이루어지는데, 본 논문에서는 이러한 PAGA Audio Coverage 관련 요구조건과 합리적인 적용방안, 해석 및 평가 방안에 대하여 사례를 통해 소개하고자 한다.

  • PDF

Case Study on the detailed standard setting and Application for QRA in Honam high speed railway tunnel (호남고속철도터널의 정량적 위험도 분석(QRA)을 위한 세부기준수립 및 적용사례)

  • Kim, Seon-Hong;Moon, Yeon-Oh;Seok, Jin-Ho;Kim, Ki-Lim;Kim, Chan-Dong;Yoo, Ho-Sik
    • Proceedings of the Korean Society for Rock Mechanics Conference
    • /
    • 2008.10a
    • /
    • pp.249-260
    • /
    • 2008
  • Although the accident rate is lower than the road tunnel, fire in railway tunnel can bring large damage of human life. In the high speed railway tunnel, the possibility of the railway-disaster (fire) is growing in consideration of the speedy railway and the tunnel length. For that reason, MLTM (Ministry of Land, Transport and Maritime Affairs) published "Rules about the Safety Standard of Railroad (2005.10.27)" and "The Detailed Safety Standard of Railroad (2006.9.22)". According to those, QRA(Quantitative Risk Analysis) technique is recommended to be applied to railway tunnel design which is longer than 1km for assuring the safety function and estimating the risk. However, it is difficult to perform the disaster prevention design due to lack of the detailed standards about event scenario, fire intensity, incidence rate of accidents etc. Therefore, This paper introduces the case of tunnel design for disaster prevention of the Honam high speed railway including the detailed standards of QRA and reasonable safety facilities.

  • PDF

A study on the optimal ventilation and smoke exhaust systems in case of fire in subway stations installed with PSD (PSD가 설치된 지하철 역사 내 화재 시 최적 배연시스템 연구)

  • Kim, Hyo-Gyu;Yoo, Ji-Oh;Kim, Doo-Young
    • Journal of Korean Tunnelling and Underground Space Association
    • /
    • v.20 no.2
    • /
    • pp.527-539
    • /
    • 2018
  • The subway used by many passengers is required to maintain a safe and comfortable environment and PSD (Platform Screen Door) must be installed in the platform after reinforcing the standard in 2003. In the previous research, in case of subway fire to control it, it is necessary to design the optimal ventilation and smoke exhaust system according to equipment capacity of the smoke exhaust system. Therefore, in this study, based on the results of previous research, three-dimensional numerical analysis was performed for the CO gas and smoke flow by the subway ventilation system in case of platform fire. As a result of this study, it was found that in case of emergency, if only the upper-level smoke exhaust system is activated, the risk of evacuation is high due to CO gas (653.8 ppm) and smoke concentration ($768.4mg/m^3$). And when all the smoke exhaust systems are activated and only the fire side PSD is opened, CO gas (36.0 ppm) and smoke concentration ($26.2mg/m^3$) are detected and the propagation range of smoke flow was reduced. When all the smoke exhaust systems are activated and only the fire side PSD is closed, it was analyzed as the most effective ventilation mode in the evacuation environment due to the absence of smoke-recirculation.