• 제목/요약/키워드: 승강기 산업

검색결과 53건 처리시간 0.025초

마이크로그리드 전력변환장치용 커패시터 고장 검출 기법 (Capacitor Failure Detection Technique for Microgrid Power Converter)

  • 이우현;송광철;안준재;박성미;박성준
    • 한국산업융합학회 논문집
    • /
    • 제26권6_2호
    • /
    • pp.1117-1125
    • /
    • 2023
  • The DC part of the DC microgrid power conversion system uses capacitors for buffers of charge and discharge energy for smoothing voltage and plays important roles such as high frequency component absorption, power balancing, and voltage ripple reduction. The capacitor uses an aluminum electrolytic capacitor, which has advantages of capacity, low price, and relatively fast charging/discharging characteristics. Aluminum electrolytic capacitors(AEC) have previous advantages, but over time, the capacity of the capacitors decreases due to deterioration and an increase in internal temperature, resulting in a decrease in use efficiency or an accident such as steam extraction due to electrolyte evaporation. It is necessary to take measures to prevent accidents because the failure diagnosis and detection of such capacitors are a very important part of the long-term operation, safety of use, and reliability of the power conversion system because the failure of the capacitor leads to not only a single problem but also a short circuit accident of the power conversion system.

ESS를 활용한 DC-Grid 안정성 기반 MG 운영 기법 (MG Operation Technique based on DC-Grid Stability using ESS)

  • 김종철;김춘성;박용운;박성미;박성준
    • 한국산업융합학회 논문집
    • /
    • 제26권6_3호
    • /
    • pp.1269-1278
    • /
    • 2023
  • This paper presents an operational technique that can secure the stability of DC-Grid centering on MG operated based on ESS in multiple MG where three DC-based microgrid(MG) are interconnected. MG1(PV 600kWp, ESS 1.5MWh) has an 830Vdc grid voltage, MG2(PV 300kWp, ESS 1.1MWh) and MG3(PV 100kWp, ESS 500kWh) are DC-based MG with a 750Vdc grid voltage, and MG1 and MG2, 3 are linked by separate DC/DC converters (BTB). In order to keep different grid voltages stable, the power transmission capacity between MG1 and two MG(MG2, MG3) connected with an independent BTB converter was adjusted to secure the overall stability of the system, and this was verified by confirming that the surplus capacity of ESS was maintained in actual operation.

딥러닝 모델을 활용한 승강기 결함 분류 (Elevator Fault Classification Using Deep Learning Model)

  • 정영진;장찬영;강성우
    • 대한안전경영과학회지
    • /
    • 제24권4호
    • /
    • pp.1-8
    • /
    • 2022
  • Elevators are the main means of transport in buildings. A malfunction of an elevator in operation may cause in convenience to users. Furthermore, fatal accidents, such as injuries and death, may occur to the passengers also. Therefore, it is important to prevent failure before accidents happen. In related studies, preventive measures are proposed through analyzing failures, and the lifespan of elevator components. However, these methods are limited to existing an elevator model and its surroundings, including operating conditions and installed environments. Vibration occurs when the elevator is operated. Experts have classified types of faults, which are symptoms for malfunctions (failures), via analyzing vibration. This study proposes an artificial intelligent model for classifying faults automatically with deep learning algorithms through elevator vibration data, hereby preventing failures before they occur. In this study, the vibration data of six elevators are collected. The proposed methodology in this paper removes "the measurement error data" with incorrect measurements and extracts operating sections from the input datasets for proceeding deep learning models. As a result of comparing the performance of training five deep learning models, the maximum performance indicates Accuracy 97% and F1 Score 97%, respectively. This paper presents an artificial intelligent model for detecting elevator fault automatically. The users' safety and convenience may increase by detecting fault prior to the fatal malfunctions. In addition, it is possible to reduce manpower and time by assisting experts who have previously classified faults.

노후시설 개보수와 삶의 질 향상에 관한 연구 (Study on Renovation of Old Facilities and Improvement of Quality of Life)

  • 조태관
    • 한국재난정보학회:학술대회논문집
    • /
    • 한국재난정보학회 2022년 정기학술대회 논문집
    • /
    • pp.223-224
    • /
    • 2022
  • 노후주거시설의 개보수의 필요성이 대두 되고 있으나 관련법규의 제약에 의해 내 외부 미관수선 정도에 그치고 있는 것이 현실이다. 그래 조금 나은 동선과 공간으로 수선시 법을 위반하여 불법 건축물로 낙인되어 지는 것이다. 경제적인 여유가 없는 노령층등 사회적 약자가 거주하는 공간은 더욱 더 열약하여 화장실, 주방, 수평이동 통로, 승강기등의 편의시설과 붕괴, 침하, 화재, 폭발, 오염등의 안전을 위협하는 위험요소의 제거등이 당장 필요하여도 미봉에 그치는 경우가 다반사이다. 또 이러한 노후 건물의 개보수는 신, 개축 보다 어렵고 비용도 많이 들면서 그 효과도 미미한 것이 사실이나 당장 신, 개축하기에는 관련 법규에 저촉되거나 주변 여건에 부합하지 않아 실시 할 수 없는 경우가 많아 이를 개선하고 합리적인 롤 모델을 만들고 필요하다면 관련법령도 정비할 필요가 있는 것이다. 노후되지 않아도 현시점에서 생활의 불편함을 느껴 개선할 필요가 있는 경우도 관련 법규의 유연함이 필요할 것이다. 본 연구는 이러한 노후 주거 시설 및 현실 여건에 맞지않는 주거 시설을 보다 쉽고 합리적으로 개 보수할 수 있는 여건이 조성되도록 관련 건축법령의 개선, 또 경제적 여유가 없는 저소득층의 개보수여건을 개선할 수 있는 정부지원방안, 이러한 노후 주거시설의 개보수가 부동산 시장에 어떠한 영향을 초래할 수 있는지를 기존 연구들과 비교하여 합리적인 방안을 도출하고저 함.

  • PDF

비상 발전기를 이용한 유도전동기의 소프트 기동 시스템 (Soft Start System of Induction Motor using Emergency Generator)

  • 황보찬;고재하;이정환;박성미;박성준
    • 한국산업융합학회 논문집
    • /
    • 제25권3호
    • /
    • pp.433-441
    • /
    • 2022
  • In general, in an emergency generator system for an electric facility including an induction motor load, an emergency power generation facility larger than the facility load capacity is built due to the initial starting current of the induction motor. In order to reduce this economic burden, various methods to reduce the inrush current of induction motors are applied to suppress the additional expansion of generators due to the reduction of power generation facilities and the increase in electrical facilities. Among these methods, when a system with a built-in soft start function of an induction motor using an inverter is built, it is the best way to reduce the inrush current of the induction motor to less than the rated current. However, in this case, the installation cost of the inverter to drive the induction motor increases. This paper proposes a soft start method of an induction motor by expanding the frequency and voltage control operation area of an emergency generator. In addition, proposed a speed calculation method based on power factor information, which is essential information for stable soft start of an induction motor, and a method for generating a speed command value of the governor for starting with maximum torque.

배터리 파라미터 측정을 이용한 충전종지전압 예측기법 (Prediction Method of End of Charge Voltage using Battery Parameter Measurement)

  • 김호용;왕이페이;박성미;박성준;손경종
    • 한국산업융합학회 논문집
    • /
    • 제25권3호
    • /
    • pp.387-396
    • /
    • 2022
  • Recently, e-Mobility, which is a personal mobility device such as an electric bicycle or an electric scooter, is rapidly emerging. However, since E-Mobility has various voltage systems due to the characteristics of its products, it is essential for companies that operate them to use multiple dedicated chargers. A universal charger capable of charging batteries of various voltage systems with one charger is required to reduce the cost of purchasing and managing multiple dedicated chargers. For this, information on the EOC(End of Charge) is essential. In order to know the EOC, it is necessary to detect the internal impedance of the battery. However, the internal impedance of the battery changes according to various conditions such as SOH(State Of Health), SOC(State Of Charge), and ambient temperature. By observing the change in these parameters, the state of the battery can be diagnosed and the EOC can be predicted. In this paper, we propose an algorithm to analyze the battery's internal impedance and to predict the EOC, in order to acquire information on the EOC of the battery, which is an essential requirement of a universal charger.

새로운 DFT 비교기를 이용한 자동 다전원 동기절체 스위치에 관한 연구 (A Study on Automatic Multi-Power Synchronous Transfer Switch using New DFT Comparator)

  • 곽아림;박성미;손경종;박성준;김종철
    • 한국산업융합학회 논문집
    • /
    • 제25권3호
    • /
    • pp.423-431
    • /
    • 2022
  • The UPS(Uninterruptible Power Supply) system operates in the battery charging mode when the grid is normal, and in the UPS mode, which is the battery discharge mode when a grid error occurs. Since the UPS must supply the same voltage as the grid to the load within 4 [ms] in case of a grid error, the switching time and power recovery time should be short when controlling the output voltage and current of the UPS, and the power failure detection time is also important. The power outage detection algorithm using DFT(Discrete Fourier Transform) proposed in this paper compares the grid voltage waveform with the voltage waveform including the 9th harmonic generated through DFT using Schmitt trigger to detect power outage faster than the existing power outage monitoring algorithm. There are advantages. Therefore, it is possible to supply instant and stable power when switching modes in the UPS system. The multi-power-applied UPS system proposed in this paper uses DFT, which is faster than the conventional blackout monitoring algorithm in detecting power failure, to provide stable power to the load in a shorter time than the existing power outage monitoring algorithm when a system error occurs. The detection method was applied. The changeover time of mode switching was set to less than 4 [ms], which is 1/4 of the system cycle, in accordance with KSC 4310 regulation, which was established by the Industrial Standards Council on the regulation of uninterruptible power supply. A 10 [kW] UPS system in which commercial voltage, vehicle generator, and auxiliary diesel generator can be connected to each of the proposed transfer devices was constructed and the feasibility was verified by conducting an experiment.

E-Highway를 위한 팬터그래프의 가공선 위치정보 취득에 관한 연구 (A Study on Acquisition of Overhead Line Location Information of Pantograph for E-Highway)

  • 송광철;안준재;레동부;박성미;박성준
    • 한국산업융합학회 논문집
    • /
    • 제26권5호
    • /
    • pp.915-923
    • /
    • 2023
  • As environmental regulations on carbon emissions are strengthened worldwide, the existing internal combustion engine-centered automobile industry is being reformed. In particular, large buses and large cargo trucks are pointed out as one of the main causes of environmental destruction due to excessive carbon emissions. The E-Highway power collection system, which has recently been proposed as a solution, uses the vehicle's battery as a backup power source or regenerative braking, depending on whether the pan head of the pentograph installed in the vehicle is in contact with the overhead line. It is used to store the excess energy generated. However, wear through contact due to continuous contact reduces the current collection effect and causes failure. In this paper, by using the current difference, the horizontal position information of the panhead in contact with the overhead line is acquired, thereby reducing the abrasion of the conductor and the panhead Make it possible to follow the overhead line. The position estimation method proposed in this paper simply configures a device that can detect the position of the overhead line of the pantograph by the difference in resistance. It is economical and has the advantage of reducing the volume. The characteristics of the pantograph estimating the location of overhead lines were analyzed using the difference between the two currents of the current collector, the feasibility of the positioning estimation system was verified through simulations and experiments.

Two-Level 전압 인가에 의한 전자접촉기 구동 전력 저감 (Reduce Power of Magnetic Contactor using the Two-Level Apply Voltage)

  • 이강열;나혜영;박성미;박성준;손경종
    • 한국산업융합학회 논문집
    • /
    • 제26권5호
    • /
    • pp.925-936
    • /
    • 2023
  • Currently, due to the rapid increase in power demand and the increase in capacity of power converters, the capacity of electromagnetic contactors is also increasing, and the burden on SMPS for the power that can drive them is increasing. Although the initial starting operation current of an electromagnetic contactor is significantly larger than the holding current for maintaining contact, most electromagnetic contactors apply the same voltage as the initial starting operation. An electromagnetic contactor must continuously apply a holding current to maintain the contact point, and the larger the capacity, the larger the current must be applied. This paper proposes a two-level magnetic contactor drive that allows setting the initial starting operation current to fully attach the contact point of the magnetic contactor and the holding current to maintain subsequent operation. In addition, a low-cost drive topology of analog and digital methods was proposed for various field applications, and an algorithm based on the ripple of the excitation current was proposed to determine whether the magnetic contactor was opened or closed without using a separate contact point. The feasibility of the proposed method was proven through Psim simulation experiments.

엑티브 셀 밸런싱을 위한 새로운 전력 피드백 방식의 플라이백 토폴로지에 관한 연구 (Study on the Fly-back Topology of New Power Feed-back Method for Active Cell Balancing )

  • 강성용;송명진;박성미;박성준;고재하
    • 한국산업융합학회 논문집
    • /
    • 제26권6_2호
    • /
    • pp.1083-1095
    • /
    • 2023
  • Recently, the demand for low-voltage, high-capacity ESS is rapidly increasing due to the revitalization of the e-mobility industry, which is mainly powered by electricity. In addition, the demand for portable power banks is rapidly increasing due to the revitalization of leisure industries such as camping and fishing. The ESS with this structure consists of a small number of series cells and many parallel cells, resulting in a system with a large rated current. Therefore, the number of power devices for cell balancing configured in series is small, but a balancing device with a large current capacity is required. Construction of a constant temperature device in such a low-voltage, high-current ESS is difficult due to economic issues. The demand for an active balancing system that can solve the passive balancing heating problem is rapidly increasing. In this paper, propose a power feedback fly-back topology that can solve the balancing heating problem. The characteristic of the proposed topology is that a series-connected voltage sharing voltage is used as the input of the flyback converter, and the converter output is connected to one transformer. In this structure, the converter output for cell voltage balancing shares magnetic flux through one high-frequency transformer, so the cell voltage connected to the converter automatically converges to the same voltage.