• Title/Summary/Keyword: 승강기

Search Result 265, Processing Time 0.028 seconds

Measures and Cause Analysis of Electrical Disturbance for Elevator Equipment of the Apartment House (공동주택 승강기 설비의 전기적 장해 원인 분석 및 대책에 관한 연구)

  • Kim, Gi-Hyun;Bae, Suk-Myong;Park, Chee-Hyun;Choi, Myeong-Il
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.21 no.3
    • /
    • pp.88-95
    • /
    • 2007
  • Domestic elevator accidents which are related to human life such as death are occurring steadily. This research measured and analyzed for the quality of power source which has possibility to be associated with fault and malfunction of elevator equipment although it is not direct cause examination. In conclusion, we acquired the result that there is possibility that the quality of power source(Sag, Interruption, Harmonic, Electromagnetism emission waveform, Static electricity etc) has an effect on movement of elevator through examination of three elevator facility models and suggested measures for it. Accordingly, this research result will be used as data to suggest establishment of elevator examination regulations and KS regulations for domestic elevator industry and the least safety of household using elevator.

A study on the characteristics and actual conditions of operation noise and vibration of rope elevators in high-rise apartments (고층아파트 로프식 승강기의 운행 소음 및 진동 특성과 실태에 관한 연구)

  • Kang, Min-Woo;Oh, Yang-Ki
    • The Journal of the Acoustical Society of Korea
    • /
    • v.40 no.1
    • /
    • pp.84-91
    • /
    • 2021
  • An Elevator is a very important equipment in high-rise apartments. The noise generated by an elevator is causing inconvenience to residents. However, there are no laws and regulations on elevator noise, and moreover it is not clear how to measure and evaluate elevator noise. For these problems, the first priority should be given to grasping the characteristics of noise and vibration generated during elevator operation. In this study, noise and vibration generated when operating a rope-type elevator in a high-rise apartment are divided according to the number of floors and the type of room, and the noise and vibration are simultaneously measured to understand the characteristics of noise and vibration. The correlation coefficient according to the experimental conditions was determined. As a result, it was found that elevator noise was mainly composed of components in the 125 Hz to 500 Hz band, and the correlation with vibration in the 125 Hz to 500 Hz band was also significant. For the top layer, it was confirmed that the correlation coefficient was very high at 0.8 level.

A Design and Implementation of the Lift Safety Inspection System using Android Smart Phone (안드로이드기반 스마트폰을 이용한 승강기 안전진단 시스템 설계 및 구현)

  • Choi, Sung-Hyun;Kim, Jong-Soo;Kim, Tai-Suk
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.16 no.1
    • /
    • pp.113-118
    • /
    • 2012
  • This thesis suggests how to design and implement an Android smart phone application which can perform self check or safety inspection of lifts effectively. The safety checks of lifts go in the way that inspectors check the lifts' conditions generally and record manually following a form at the moment. This thesis analyses lift maintenance industry and introduces how to design a system to proceed effective self check using a smart phone with Android OS. By using a smart phone to check lifts, we can have advantages to improve the quality of self check and maintain careers establishing information database about safety items.

The Comparative Study on Safety Factors at Elevator Management System Operation (승강기 관리시스템 운영 시 안전요소에 관한 비교연구)

  • Park, Joo-Bong;Shin, Seung-Jung
    • The Journal of the Institute of Internet, Broadcasting and Communication
    • /
    • v.14 no.6
    • /
    • pp.159-162
    • /
    • 2014
  • Recently, from 2008 to 2012, there are many of elevator safety patents from patent office survey. In this paper, we analyzed the elevator safety patent from 2009 to 2013, found out safety factor is safety control, emergency stop equipment and door opening equipment. Through reliability statistics, we defined the most important things for safety elevator factor is this three things, studied the reason about many patents. Finally, we propose the Kinect Scada elevator system for prevention safety accident.

A Design and Implementation of the Integrated Framework linked Manufacturer-Specifications of the Elevators based on Android System (안드로이드 시스템 기반 승강기 제조사별 통합 연동 프레임워크 설계 및 구현)

  • Kim, Woon-Yong;Park, Seok-Gyu
    • Journal of Advanced Navigation Technology
    • /
    • v.17 no.6
    • /
    • pp.785-791
    • /
    • 2013
  • Recently, Elevator industry is pursuing new challenges to the model of the IT convergence. The core of the convergence technologies may be the effective control and maintenance of the machine. However, because current elevator management model provides each specific model for his elevator, the management models have a variety of heterogeneous configuration so that it makes management companies to manage the elevators with many overhead. In this paper, we propose the integration framework for the various elevator models. We use proposed system based on the Android framework that is rapidly expanding technology in the embedded environment, and we propose design approach for the integration of variety of lift devices so that it provide a more efficient and stable service environment. In this way, we could integrate various device models of an elevator for the management and maintenance effectively and quickly.

The Implementation of a Lift Emergency Video Call System based on WebRTC using OpenAPI

  • Woon-Yong Kim
    • Journal of the Korea Society of Computer and Information
    • /
    • v.28 no.10
    • /
    • pp.155-161
    • /
    • 2023
  • In this paper, we present a WebRTC-based emergency video call system structure that builds a service system in a constant monitoring environment to increase the usability and stability of elevator emergency call devices. The proposed system provides a smooth call environment between the emergency call system in the elevator and maintenance managers in case of an emergency, performs rapid response processing to elevator emergency calls through monitoring of the target elevator, and handles any emergency calls that may occur in the physical space of the elevator. The purpose is to build an environment that can implement low-latency, real-time video call services of voice and video by overcoming the physical constraints required for video calls. To this end, we have established a service environment based on OpenAPI, which is currently used in various fields and its performance has been proven, and provides video calls and emergency situation dissemination through rapid messaging by providing low-latency call quality. The presented system structure will be able to provide a basis for expanding various functions and constructing a reliable service environment and intelligent model for the elevator system through combination with the elevator control panel and various devices.

승강기 제어반 교체로 전력소모 $50\%$ 절감

  • 에너지절약전문기업협회
    • The Magazine for Energy Service Companies
    • /
    • s.3
    • /
    • pp.28-29
    • /
    • 2000
  • 만약 건물마다 엘리베이터가 없다면 우리 생활은 어떻게 될까? 고층건물을 걸어서 오르내려야 하는 불편함과 시간낭비, 그밖에도 생활의 제약을 많이 겪어야 할 것이다. 이처럼 우리에게 편리함을 주는 문명의 이기지만 안전관리를 소홀히 할 경우에는 소중한 생명을 위협하는 무기로 돌변한다. 이번 호 ''ESCO피플''에 초대한 최종성씨는 12년동안 성모병원의 승강기 관리담당자로서 병원내 승강기를 안전하고 편리하면서도 전력 손실을 줄일 수 있도록 효율적으로 관리하는데 노력해왔다.

  • PDF

승강기용 구명호흡장치의 개발을 위한 실험적 연구

  • Jeong, Hwa-Jin;Gwak, Ji-Hyeon;Gu, Jae-Hyeon;Baek, Jong-Tae
    • Proceedings of the Korea Institute of Fire Science and Engineering Conference
    • /
    • 2013.04a
    • /
    • pp.9-10
    • /
    • 2013
  • 최근 산업의 고도화에 따른 건물의 고층화로 하나 또는 그 이상의 승강기를 보유한 건물들이 증가하고 있다. 이러한 건물에서 화재와 같은 긴급한 재난 발생 시 피난계단을 이용하여 탈출해야 한다는 상식에도 불구하고 본능적으로 승강기를 이용하여 대피하려는 경향이 뚜렷하다. 화재상황에서 승강기 이용 시 독성의 연기 유입으로 피난 활동이 어려우며, 전원 차단으로 정지 시 연기에 질식사할 확률이 급증한다. 따라서 승강기 내부로의 고립이나 승강기를 이용한 피난활동 시 연기로부터 안전한 호흡장치의 개발을 위한 연구를 진행하고자 한다.

  • PDF

TTA와 함께한 ICT표준자문서비스 - 엠투엠테크, IoT 표준으로 국내 승강기 시장 지킨다

  • TTA 표준화본부 표준확산부
    • TTA Journal
    • /
    • s.168
    • /
    • pp.100-103
    • /
    • 2016
  • (주)엠투엠테크는 승강기 산업분야에서 IoT 기반 스마트 디바이스를 개발 중인 스타트업 기업이다. 특히, 윈격진단, 포렌식 기능 등 확장된 관제서비스가 가능한 스마트 디바이스 개발에 주력하고 있다. 하나의 디바이스가 다양한 제조사의 승강기에 적용되려면 승강기의 주요 부품, 디바이스, 관제 센터 간의 표준화된 통신 체계가 필요하며, 기존 승강기의 안전을 담보할 수 있는 시스템 유지 관리 체계가 구축되어야 한다. 미래에는 전체 스마트 디바이스로의 연결을 더욱 확대하여 궁극적으로 스마트 빌딩, 도시로의 적용 역시 가능하게 할 단계적 진화 모델의 고려가 필요한 것도 물론이다. (주)엠투엠테크가 TIA의 중소 중견기업을 위만 표준 자문서비스를 신정만 것은 이 때문이었다. (주)엠투엠테크는 TTA 표준 자문전문가들과 함께 국제 표준을 기반으로 한 IoT 프로토콜을 적용해 제품을 업그레이드할 수 있는 시스템 아키텍처를 설계할 수 있었다.

  • PDF

An Analysis of Harmonics on Inverter Elevator System (인버터 승강기 시스템의 고조파 실태 분석)

  • 김정태;이기홍;홍규장
    • The Proceedings of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.8 no.5
    • /
    • pp.41-48
    • /
    • 1994
  • 국내에서 제작된 인버터 승강시 시스템의 고조파 발생량을 분석하고 타 전기설비에 미치는 영향을 알아보기 위하여 고층 아파트와 빌딩에 설치된 인버터 승강기를 대상으로 고조파 전압·전류를 측정하였다. 그 결과 인버터 승강기 시스템의 총고조파 전압 왜형율은 작게 나타났으나, 총고조파 전류 왜형율은 상당히 큰 것으로 밝혀졌다. 공동주택의 전기설비에 미치는 영향으로는, 역률 개선용 콘덴서에는 큰 문제가 되지 않으나 비상 발전기를 고려하여 인버터 승강기 시스템의 고조파 발생량을 줄일 필요가 있는 것으로 나타났다. 또한, 비상발전기의 허용 %등가역상전류와 본 연구의 실측값을 고려하여 인버터 승강기 시스템의 고조파 전류 규제값을 총고조파 전류 왜형율 40% 이하가 되도록 권장값을 제안하였다.

  • PDF